954 resultados para laser terminal level lifetime


Relevância:

100.00% 100.00%

Publicador:

Resumo:

介绍了目前测量掺钕材料激光终态能级寿命的三种方法,通过对三种测量方法比较,采用间接法测量激光终态能级寿命相对简单易行。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neutron irradiated high resistivity (4-6 kOMEGA-cm) silicon detectors in the neutron fluence (PHI(n)) range of 5 X 10(11) n/cm2 to 1 X 10(14) n/cm2 have been studied using a laser deep level transient spectroscopy (L-DLTS). It has been found that the A-center (oxygen-vacancy, E(c) = 0.17 eV) concentration increases with neutron fluence, reaching a maximum at PHI(n) almost-equal-to 5 X 10(12) n/cm2 before decreasing with PHI(n). A broad peak has been found between 200 K and 300 K, which is the result of the overlap of three single levels: the V-V- (E(c) = 0.38 eV), the E-center (P-V, E(c) = 0.44 eV), and a level at E(c) = 0.56 eV that is probably V-V0. At low neutron fluences (PHI(n) < 5 X 10(12) n/cm2), this broad peak is dominated by V-V- and the E-centers. However, as the fluence increases (PHI(n) greater-than-or-equal-to 5 X 10(12) n/cm2), the peak becomes dominated by the level of E(c) = 0.56 eV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lifetime of a plasma channel produced by self-guiding intense femtosecond laser pulses in air is largely prolonged by adding a high voltage electrical field in the plasma and by introducing a series of femtosecond laser pulses. An optimal lifetime value is realized through adjusting the delay among these laser pulses. The lifetime of a plasma channel is greatly enhanced to 350 ns by using four sequential intense 100fs( FWHM) laser pulses with an external electrical field of about 350kV/m, which proves the feasibility of prolonging the lifetime of plasma by adding an external electrical field and employing multiple laser pulses. (c) 2006 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a laser induced sensitized fluorescence spectrometry for measuring the spontaneous emission branching ratios o?the transitions from the ten levels 5f36d7s7p-7M7, 5f36d7s7p-7L6, 5f37s27p-5K6, 5f26d27s2 - 5L7, 5f46d7s - 7L6, (17,070cm-1)-5L6, 5f26d27s2-5K6, 6d7s7p-7L5, 5f36d7s7p-7K5 and 5f26d27s2-5I5 to the ground state of atomic uranium (UI) for the first time. Their relative oscillator strengths have been measured by means of hollow cathode discharge (HCD) emission spectrometry. The radiative...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dentin hipersensitivity (DH) is a relatively common clinical condition, especially in periodontal patients after treatment. In this study it was evaluated 28 teeth who presented dentin hypersensitivity. The teeth were subjected to clinical and radiographic exams and were divided into groups following the treatment and the time of examination after application proposed: GI: PO 3% (Potassium Oxalate-group control)/Baseline; GII: PO 3%/3 days after first session; GIII: PO 3%/6 days; GIV: PO 3%/30 days; GV: PO 3%/60 days; GVI: PO 3%/90 days; GVII: Laser (Low-level diode laser with 110 mW/cm(2))/Baseline; GVIII: Laser/7 days after first session; GIX: Laser/14 days; GX: Laser/30 days; GXI: Laser/60 days; and GXII: Laser/90 days. The groups I-VI, the teeth were subjected to 3 applications (GI-GIII) of desensitizing agent at regular intervals of seven days. The Groups VII-XI, each tooth was subjected to three applications (GVII GIX) in three different points (mesial, meddle and distal surfaces) with an interval of 72 h. The time of application in each point was of 33 s and the patients from both groups were followed up to 90 days. The nonparametric test Friedman (alpha = 0.05) was applied and the test of Mann Whitney (alpha = 0.05) was used to compare the time of examination between groups. The application of Laser was effective 6 days after first session and to PO was 30 days. It was observed that both treatments were effective for the reduction of dentin hypersensitivity, however the laser presented better effectiveness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of low-level laser therapy (LLLT) on odontoblast-like MDPC-23 cells exposed to carbamide peroxide (CP 0.01 %-2.21 μg/mL of H2O2). The cells were seeded in sterile 24-well plates for 72 h. Eight groups were established according to the exposure or not to the bleaching agents and the laser energy doses tested (0, 4, 10, and 15 J/cm2). After exposing the cells to 0.01 % CP for 1 h, this bleaching solution was replaced by fresh culture medium. The cells were then irradiated (three sections) with a near-infrared diode laser (InGaAsP-780 ± 3 nm, 40 mW), with intervals of 24 h. The 0.01 % CP solution caused statistically significant reductions in cell metabolism and alkaline phosphate (ALP) activity when compared with those of the groups not exposed to the bleaching agent. The LLLT did not modulate cell metabolism; however, the dose of 4 J/cm2 increased the ALP activity. It was concluded that 0.01 % CP reduces the MDPC-23 cell metabolism and ALP activity. The LLLT in the parameters tested did not influence the cell metabolism of the cultured cells; nevertheless, the laser dose of 4 J/cm2 increases the ALP activity in groups both with and without exposure to the bleaching agent. © 2013 Springer-Verlag London.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the influence of bone marrow aspirate (BMA), low-level laser therapy (LLLT) and their combination on bone healing in surgically created critical-size defects (CSDs) in rat calvaria. 40 rats were divided into four groups: C (control), BMA, LLLT and BMA/LLLT. A 5 mm diameter CSD was created in the calvarium of each animal. In Group C, the defect was filled by blood clot only. In Group BMA, the defect was filled with BMA. In groups LLLT and BMA/LLLT, the defect received laser irradiation (InGaAlP laser), was filled with blood clot or BMA respectively, and irradiated again. Animals were euthanized 30 days postoperatively. Histomorphometric and immunohistochemical analyses were performed. Newly formed bone area (NFBA) was calculated as percentage of the total area of the original defect. Proliferating cell nuclear antigen (PCNA), runt-related transcription factor 2 (Runx2) and osteocalcin (OCN) immunohistochemical staining were performed. PCNA-positive, Runx2-positive and OCN-positive cells were quantified. Data were statistically analyzed. Group BMA/LLLT had significantly greater NFBA than groups C, BMA or LLLT. Group BMA presented significantly greater NFBA than control, while group LLLT did not. Group BMA/LLLT presented a significantly higher number of PCNA-positive and OCN-positive cells than any of the other groups. Groups BMA/LLLT and BMA showed a significantly lower number of Runx2-positive cells than groups C or LLLT. The combination of BMA/LLLT yielded significantly greater bone formation in surgically created CSD in rat calvaria when compared to control, or either treatment alone. © 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The objective of this study was to apply low-level laser therapy (LLLT) to accelerate the recovery process of a child patient with Bell's palsy (BP). Design: This was a prospective study. Subject: The subject was a three-year-old boy with a sudden onset of facial asymmetry due to an unknown cause. Materials and methods: The low-level laser source used was a gallium aluminum arsenide semiconductor diode laser device (660nm and 780 nm). No steroids or other medications were given to the child. The laser beam with a 0.04-cm2 spot area, and an aperture with approximately 1-mm diameter, was applied in a continuous emission mode in direct contact with the facial area. The duration of a laser session was between 15 and 30 minutes, depending on the chosen points and the area being treated. Light was applied 10 seconds per point on a maximum number of 80 points, when the entire affected (right) side of the face was irradiated, based on the small laser beam spot size. According to the acupuncture literature, this treatment could also be carried out using 10-20 Chinese acupuncture points, located unilaterally on the face. In this case study, more points were used because the entire affected side of the face (a large area) was irradiated instead of using acupuncture points. Outcome measures: The House-Brackmann grading system was used to monitor the evolution of facial nerve motor function. Photographs were taken after every session, always using the same camera and the same magnitude. The three-year-old boy recovered completely from BP after 11 sessions of LLLT. There were 4 sessions a week for the first 2 weeks, and the total treatment time was 3 weeks. Results: The result of this study was the improvement of facial movement and facial symmetry, with complete reestablishment to normality. Conclusions: LLLT may be an alternative to speed up facial normality in pediatric BP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Of all laser-based processes, laser machining has received little attention compared with others such as cutting, welding, heat treatment and cleaning. The reasons for this are unclear, although much can be gained from the development of an effcient laser machining process capable of processing diffcult materials such as high-performance steels and aerospace alloys. Existing laser machining processes selectively remove material by melt shearing and evaporation. Removing material by melting and evaporation leads to very low wall plug effciencies, and the process has difficulty competing with conventional mechanical removal methods. Adopting a laser machining solution for some materials offers the best prospects of effcient manufacturing operations. This paper presents a new laser machining process that relies on melt shear removal provided by a vertical high-speed gas vortex. Experimental and theoretical studies of a simple machining geometry have identifed a stable vortex regime that can be used to remove laser-generated melt effectively. The resultant combination of laser and vortex is employed in machining trials on 43A carbon steel. Results have shown that laser slot machining can be performed in a stable regime at speeds up to 150mm/min with slot depths of 4mm at an incident CO2 laser power level of 600 W. Slot forming mechanisms and process variables are discussed for the case of steel. Methods of bulk machining through multislot machining strategies are also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Absorption spectra of formaldehyde molecule in the gas phase have been recorded using photoacoustic (PA) technique with pulsed dye laser at various power levels. The spectral profiles at higher power levels are found to be different from that obtained at lower laser powers. Two photon absorption (TPA) is found to be responsible for the photoacoustic signal at higher laser power while the absorption at lower laser power level is attributed to one photon absorption (OPA) process. Probable assignments for the different transitions are given in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the effectiveness of the clinical use of the gallium-aluminum-arsenium (GaAlAs) laser at the maximum and minimum energies recommended by the manufacturer for the treatment of dentine hypersensitivity. Background Data: Dentine hypersensitivity (DH) is a response to a stimulus that would not usually cause pain in a healthy tooth. It is characterized by sharp pain of short duration from the denuded dentin. Its etiology is unknown. The dentin only begins to show sensitivity when exposed to the buccal environment. This exposure can result after removal of the enamel and/or dental cement, or after root denudation. Different treatments are proposed for this disorder. Materials and Methods: In this study, 25 patients, with a total number of 106 cases of DH, were treated with GaAlAs low-level laser therapy (LLLT). 65% of the teeth were premolars; 14% were incisors and molars; 6.6% were canines. The teeth were irradiated with 3 and 5 J/cm 2 for up to six sessions, with an interval of 72 h between each application, and they were evaluated initially, after each application, and at 15 and 60 days follow-up post-treatment. Results: The treatment was effective in 86.53% and 88.88% of the irradiated teeth, respectively, with the minimum and maximum energy recommended by the manufacturer. There was a statistically significant difference between DH and after a follow-up of 60 days for both groups. The difference among the energy maximum and minimum was not significant. Conclusion: The GaAlAs low-level laser was effective in reducing initial DH. A significant difference was found between initial values of hypersensitivity and after 60 days follow-up post-treatment. No significant difference was found between minimum (3 J/cm 2) and maximum (5 J/cm 2) applied energy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O laser de baixa intensidade (LBI) tem demonstrado efeitos bioestimulatórios na movimentação ortodôntica, acelerando a resposta celular e, reduzindo o tempo de tratamento. Entretanto, o uso do LBI seria mais efetivo com maior potência, menor tempo (única irradiação), ou a junção da menor potência e tempo em aplicação fracionada? Este estudo visou quantificar a movimentação de molares de 64 ratos e suas alterações histológicas, submetidos a uma força ortodôntica, liberada por meio de uma mola fechada de níquel-titânio (Niti/25gf), calibrada em 20gf. Os animais foram divididos em quatro grupos (cada grupo com 16 ratos), de acordo com os seguintes protocolos de irradiação do laser GaAlAs(780nm): grupo controle , submetidos à movimentação ortodôntica mas sem aplicação do LBI ; grupo total 1 (P=60mW/DE=15J/cm²/Et=6J/t=100seg), com a movimentação ortodôntica associada à única aplicação do LBI laser (P=60mW/DE=15J/cm²/Et=6J/t=100seg) no dia zero. Grupo total 2 em que o LBI foi aplicado no dia 0, segundo o protocolo P=20mW/DE=15J/cm²/E=6J/t=300seg;,; e Grupo fracionado em que o LBI foi aplicado nos dias 0, 3 e 7, empregando-se o protocolo (P=20mW/DE=5J/cm²/E=2J/t=100seg). Os sacrifício dos ratos foi realizado em quatro momentos (dias 1,4,8 e 15), sendo que 4 ratos de cada grupo foi sacrificado em cada um dos dias. A quantidade de movimentação ortodôntica foi mensurada in loco por meio de paquímetro digital, antes da instalação das molas e, imediatamente após o sacrifício dos animais. Para o exame histológico, as maxilas foram removidas, preparadas e coradas pelo sistema H/E. Os resultados foram avaliados pela Análise de Variância, seguida do teste Tukey (p<0,05). O grupo fracionado apresentou maior movimentação dentária frente aos demais nos dias 4 e 8, sendo que os grupos total 1 e 2 demonstraram maior movimentação dentária que o controle somente no dia 8. Não houve diferença estatisticamente significante entre os grupos total 1 e 2 em todo o período avaliado. Este estudo concluiu que, o laser de baixa intensidade acelerou a movimentação dentária, salientando-se o efeito da aplicação fracionada em relação às aplicações únicas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Individual carbon nanotubes being substantially smaller than the wavelength of light, are not much responsive to optical manipulation. Here we demonstrate how decorating single-walled carbon nanotubes with palladium particles makes optical trapping and manipulation easier. Palladium decorated nanotubes (Pd/SWNTs) have higher effective dielectric constant and are trapped at much lower laser power level with greater ease. In addition, we report the transportation of Pd/SWNTs using an asymmetric line trap. Using this method carbon nanotubes can be transported in any desired direction with high transportation speed. (c) 2006 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Noise measurements from 140°K to 350°K ambient temperature and between 10kHz and 22MHz performed on a double injection silicon diode as a function of operating point indicate that the high frequency noise depends linearly on the ambient temperature T and on the differential conductance g measured at the same frequency. The noise is represented quantitatively by〈i^2〉 = α•4kTgΔf. A new interpretation demands Nyquist noise with α ≡ 1 in these devices at high frequencies. This is in accord with an equivalent circuit derived for the double injection process. The effects of diode geometry on the static I-V characteristic as well as on the ac properties are illustrated. Investigation of the temperature dependence of double injection yields measurements of the temperature variation of the common high-level lifetime τ(τ ∝ T^2), the hole conductivity mobility µ_p (µ_p ∝ T^(-2.18)) and the electron conductivity mobility µ_n(µ_n ∝ T^(-1.75)).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fabrication of very-small-aperture lasers is demonstrated, and their performance is analyzed. Because of strong optical feedback caused by a gold film on the front facet of the laser, its behavior changes: The threshold current decreases, the density of light inside the laser diode and the redshift effect of the spectra are enhanced, and the laser diode's lifetime is shorter than that of common laser diodes with large driving current. (c) 2005 Optical Society of America