994 resultados para laser interferometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variation in temperature and concentration plays a crucial role in predicting the final microstructure during solidification of a binary alloy. Most of the experimental techniques used to measure concentration and temperature are intrusive in nature and affect the flow field. In this paper, the main focus is laid on in-situ, non-intrusive, transient measurement of concentration and temperature during the solidification of a binary mixture of aqueous ammonium chloride solution (a metal-analog system) in a top cooled cavity using laser based Mach-Zehnder Interferometric technique. It was found from the interferogram, that the angular deviation of fringe pattern and the total number of fringes exhibit significant sensitivity to refractive index and hence are functions of the local temperature and concentration of the NH4Cl solution inside the cavity. Using the fringe characteristics, calibration curves were established for the range of temperature and concentration levels expected during the solidification process. In the actual solidification experiment, two hypoeutectic solutions (5% and 15% NH4Cl) were chosen. The calibration curves were used to determine the temperature and concentration of the solution inside the cavity during solidification of 5% and 15% NH4Cl solution at different instants of time. The measurement was carried out at a fixed point in the cavity, and the concentration variation with time was recorded as the solid-liquid interface approached the measurement point. The measurement exhibited distinct zones of concentration distribution caused by solute rejection and Rayleigh Benard convection. Further studies involving flow visualization with laser scattering confirmed the Rayleigh Benard convection. Computational modeling was also performed, which corroborated the experimental findings. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Sources and effects of astrophysical gravitational radiation are explained briefly to motivate discussion of the Caltech 40 meter antenna, which employs laser interferometry to monitor proper distances between inertial test masses. Practical considerations in construction of the apparatus are described. Redesign of test mass systems has resulted in a reduction of noise from internal mass vibrations by up to two orders of magnitude at some frequencies. A laser frequency stabilization system was developed which corrects the frequency of an argon ion laser to a residual fluctuation level bounded by the spectral density √s_v(f) ≤ 60µHz/√Hz, at fluctuation frequencies near 1.2 kHz. These and other improvements have contributed to reducing the spectral density of equivalent gravitational wave strain noise to √s_h(f)≈10^(-19)/√ Hz at these frequencies.

Finally, observations made with the antenna in February and March of 1987 are described. Kilohertz-band gravitational waves produced by the remnant of the recent supernova are shown to be theoretically unlikely at the strength required for confident detection in this antenna (then operating at poorer sensitivity than that quoted above). A search for periodic waves in the recorded data, comprising Fourier analysis of four 105-second samples of the antenna strain signal, was used to place new upper limits on periodic gravitational radiation at frequencies between 305 Hz and 5 kHz. In particular, continuous waves of any polarization are ruled out above strain amplitudes of 1.2 x 10^(-18) R.M.S. for waves emanating from the direction of the supernova, and 6.2 x 10^(-19) R.M.S. for waves emanating from the galactic center, between 1.5 and 4 kilohertz. Between 305 Hz and 5kHz no strains greater than 1.2 x 10^(-17) R.M.S. were detected from either direction. Limitations of the analysis and potential improvements are discussed, as are prospects for future searches.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study of the strength of a material is relevant to a variety of applications including automobile collisions, armor penetration and inertial confinement fusion. Although dynamic behavior of materials at high pressures and strain-rates has been studied extensively using plate impact experiments, the results provide measurements in one direction only. Material behavior that is dependent on strength is unaccounted for. The research in this study proposes two novel configurations to mitigate this problem.

The first configuration introduced is the oblique wedge experiment, which is comprised of a driver material, an angled target of interest and a backing material used to measure in-situ velocities. Upon impact, a shock wave is generated in the driver material. As the shock encounters the angled target, it is reflected back into the driver and transmitted into the target. Due to the angle of obliquity of the incident wave, a transverse wave is generated that allows the target to be subjected to shear while being compressed by the initial longitudinal shock such that the material does not slip. Using numerical simulations, this study shows that a variety of oblique wedge configurations can be used to study the shear response of materials and this can be extended to strength measurement as well. Experiments were performed on an oblique wedge setup with a copper impactor, polymethylmethacrylate driver, aluminum 6061-t6 target, and a lithium fluoride window. Particle velocities were measured using laser interferometry and results agree well with the simulations.

The second novel configuration is the y-cut quartz sandwich design, which uses the anisotropic properties of y-cut quartz to generate a shear wave that is transmitted into a thin sample. By using an anvil material to back the thin sample, particle velocities measured at the rear surface of the backing plate can be implemented to calculate the shear stress in the material and subsequently the strength. Numerical simulations were conducted to show that this configuration has the ability to measure the strength for a variety of materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Naturally occurring ices lie on both interstellar dust grains and on celestial objects, such as those in the outer Solar system. These ices are continuously subjected to irradiation by ions from the solar wind and/or cosmic rays, which modify their surfaces. As a result, new molecular species may form which can be sputtered off into space or planetary atmospheres. We determined the experimental values of sputtering yields for irradiation of oxygen ice at 10 K by singly (He+, C+, N+, O+ and Ar+) and doubly (C2 +, N2 + and O2 +) charged ions with 4 keV kinetic energy. In these laboratory experiments, oxygen ice was deposited and irradiated by ions in an ultra high vacuum chamber at low temperature to simulate the environment of space. The number of molecules removed by sputtering was observed by measurement of the ice thickness using laser interferometry. Preliminary mass spectra were taken of sputtered species and of molecules formed in the ice by temperature programmed desorption (TPD). We find that the experimental sputtering yields increase approximately linearly with the projectile ion mass (or momentum squared) for all ions studied. No difference was found between the sputtering yields for singly and doubly charged ions of the same atom within the experimental uncertainty, as expected for a process dominated by momentum transfer. The experimental sputter yields are in good agreement with values calculated using a theoretical model except in the case of oxygen ions. Preliminary studies have shown molecular oxygen as the dominant species sputtered and TPD measurements indicate ozone formation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Importance: This article provides, to our knowledge, the first longitudinal population-based data on refractive error (RE) in Chinese persons.

Objective: To study cohort effects and changes associated with aging in REs among Chinese adults.

Design, Setting, and Participants: A 2-year, longitudinal population-based cohort study was conducted in southern China. Participants, identified using cluster random sampling, included residents of Yuexiu District, Guangzhou, China, aged 35 years or older who had undergone no previous eye surgery.

Methods: Participants underwent noncycloplegic automated refraction and keratometry in December 2008 and December 2010; in a random 50% sample of the participants, anterior segment ocular coherence tomography measurement of lens thickness, as well as measurement of axial length and anterior chamber depth by partial coherence laser interferometry, were performed.

Main Outcomes and Measures: Two-year change in spherical equivalent refraction (RE), lens thickness, axial length, and anterior chamber depth in the right eye.

Results: A total of 745 individuals underwent biometric testing in both 2008 and 2010 (2008 mean [SD] age, 52.2 [11.5] years; 53.7% women). Mean RE showed a 2-year hyperopic shift from −0.44 (2.21) to −0.31 (2.26) diopters (D) (difference, +0.13; 95% CI, 0.11 to 0.16). A consistent 2-year hyperopic shift of 0.09 to 0.22 D was observed among participants aged 35 to 64 years when stratifying by decade, suggesting that a substantial change in RE with aging may occur during this 30-year period. Cross-sectionally, RE increased only in the cohort younger than 50 years (0.11 D/y; 95% CI, 0.06 to 0.16). In the cross-sectional data, axial length decreased at −0.06 mm/y (95% CI, −0.09 to −0.04), although the 2-year change in axial length was positive and thus could not explain the cross-sectional difference. These latter results suggest a cohort effect, with greater myopia developing among younger persons.

Conclusions and Relevance: This first Chinese population-based longitudinal study of RE provides evidence for both important longitudinal aging changes and cohort effects, most notably greater myopia prevalence among younger persons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A significant part of film production by the coating industry is based on wet bench processes, where better understanding of their temporal dynamics could facilitate control and optimization. In this work, in situ laser interferometry is applied to study properties of flowing liquids and quantitatively monitor the dip coating batch process. Two oil standards Newtonian, non-volatile, with constant refractive indices and distinct flow properties - were measured under several withdrawing speeds. The dynamics of film physical thickness then depends on time as t(-1/2), and flow characterization becomes possible with high precision (linear slope uncertainty of +/-0.04%). Resulting kinematic viscosities for OP60 and OP400 are 1,17 +/- 0,03. St and 9,9 +/- 0,2 St, respectively. These results agree with nominal values, as provided by the manufacturer. For more complex films (a multi-component sol-gel Zirconyl Chloride aqueous solution) with a varying refractive index, through a direct polarimetric measurement, allowing also determination of the temporal evolution of physical thickness (uncertainty of +/- 0,007 microns) is also determined during dip coating.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diamonds are known for both their beauty and their durability. Jefferson National Lab in Newport News, VA has found a way to utilize the diamond's strength to view the beauty of the inside of the atomic nucleus with the hopes of finding exotic forms of matter. By firing very fast electrons at a diamond sheet no thicker than a human hair, high energy particles of light known as photons are produced with a high degree of polarization that can illuminate the constituents of the nucleus known as quarks. The University of Connecticut Nuclear Physics group has responsibility for crafting these extremely thin, high quality diamond wafers. These wafers must be cut from larger stones that are about the size of a human finger, and then carefully machined down to the final thickness. The thinning of these diamonds is extremely challenging, as the diamond's greatest strength also becomes its greatest weakness. The Connecticut Nuclear Physics group has developed a novel technique to assist industrial partners in assessing the quality of the final machining steps, using a technique based on laser interferometry. The images of the diamond surface produced by the interferometer encode the thickness and shape of the diamond surface in a complex way that requires detailed analysis to extract. We have developed a novel software application to analyze these images based on the method of simulated annealing. Being able to image the surface of these diamonds without requiring costly X-ray diffraction measurements allows rapid feedback to the industrial partners as they refine their thinning techniques. Thus, by utilizing a material found to be beautiful by many, the beauty of nature can be brought more clearly into view.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electromechanical response of piezoelectrically-actuated AlN micromachined bridge resonators has been characterized using laser interferometry and electrical admittance measurements. We compare the response of microbridges with different dimensions and buckling (induced by the initial residual stress of the layers). The resonance frequencies are in good agreement with numerical simulations of the electromechanical behavior of the structures. We show that it is possible to perform a rough tuning of the resonance frequencies by allowing a determined amount of builtin stress in the microbridge during its fabrication. Once the resonator is made, a DC bias added to the AC excitation signal allows to fine-tune the frequency. Our microbridges yield a tuning factor of around 88 Hz/V for a 500 ?m-long microbridge.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The tectorial membrane has long been postulated as playing a role in the exquisite sensitivity of the cochlea. In particular, it has been proposed that the tectorial membrane provides a second resonant system, in addition to that of the basilar membrane, which contributes to the amplification of the motion of the cochlear partition. Until now, technical difficulties had prevented vibration measurements of the tectorial membrane and, therefore, precluded direct evidence of a mechanical resonance. In the study reported here, the vibration of the tectorial membrane was measured in two orthogonal directions by using a novel method of combining laser interferometry with a photodiode technique. It is shown experimentally that the motion of the tectorial membrane is resonant at a frequency of 0.5 octave (oct) below the resonant frequency of the basilar membrane and polarized parallel to the reticular lamina. It is concluded that the resonant motion of the tectorial membrane is due to a parallel resonance between the mass of the tectorial membrane and the compliance of the stereocilia of the outer hair cells. Moreover, in combination with the contractile force of outer hair cells, it is proposed that inertial motion of the tectorial membrane provides the necessary conditions to allow positive feedback of mechanical energy into the cochlear partition, thereby amplifying and tuning the cochlear response.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The most promising concept for low frequency (millihertz to hertz) gravitational wave observatories are laser interferometric detectors in space. It is usually assumed that the noise floor for such a detector is dominated by optical shot noise in the signal readout. For this to be true, a careful balance of mission parameters is crucial to keep all other parasitic disturbances below shot noise. We developed a web application that uses over 30 input parameters and considers many important technical noise sources and noise suppression techniques to derive a realistic position noise budget. It optimizes free parameters automatically and generates a detailed report on all individual noise contributions. Thus one can easily explore the entire parameter space and design a realistic gravitational wave observatory. In this document we describe the different parameters, present all underlying calculations, and compare the final observatory's sensitivity with astrophysical sources of gravitational waves. We use as an example parameters currently assumed to be likely applied to a space mission proposed to be launched in 2034 by the European Space Agency. The web application itself is publicly available on the Internet at http://spacegravity.org/designer. Future versions of the web application will incorporate the frequency dependence of different noise sources and include a more detailed model of the observatory's residual acceleration noise.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Poster presented at the 24th Annual Meeting of the Portuguese Dental Association, 12-14 November 2015 Meo Arena, Lisboa, Portugal.