995 resultados para laser cut, light excluding venetians


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method of preparation of the Si nanoparticles (NPs) incorporated in tellurite TeO2-WO3-Bi2O3 (TWB) thin films is proposed. This mew method applies RF magnetron sputtering technique at room temperature. The incorporation of Si NP was confirmed by transmission electron microscopy (TEM); isolated Si NPs with diameters of around 6 nm are observed. Energy dispersive X-ray spectroscopy (EDS) was performed during TEM analysis in order to confirm the presence of Si NP and also the other elements of the thin film. The thin films are explored with respect to the photoinduced changes of the reflectivity within the 400-65 nm spectra range using a 10 ns pulsed Nd:YAG with power densities varying up to 400 MW/cm2 and beam diameter within the 3-5 mm range. The observed processes are analyzed within a framework of trapping level conceptions for the Si NP. The possible application of the discovered materials as optical sensitive sensors is proposed. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study evaluated the effectiveness and the sensitivity of in-office tooth bleaching with the use of a hybrid photo-activation system composed by LEDs and lasers. 40 patients, both genders, aged 18 through 25 years, were randomly distributed into two treatment groups: group I, 35% hydrogen peroxide, with a total bleaching time of 135 min divided into three sessions, and group II, 35% hydrogen peroxide and photo-thermal catalysis by an LED-laser system (300 mW cm-2), for a total bleaching time of 72 min divided into three sessions. The treatment efficiency was measured by reflectance spectroscopy and sensitivity by a visual analog scale (VAS). The final luminosity value (ΔL), color variation (ΔE) and sensitivity (S) resulting from the treatments were analyzed by the generalized estimating equations method (GEEs), and Bonferroni post hoc multiple comparisons at 5% significance. The two groups presented similar colors (ΔE) and luminosities (ΔL) after treatment. Group I presented a greater sensitivity index (37.6 ± 5.9%) compared to group II (11.1 ± 3.3%), statistically significant at p < 0.05. The use of LED-laser hybrid light, as a catalyst of the bleaching agents, showed a significant decrease of provoked tooth sensitivity and a treatment time reduced by 53%, with the same aesthetic results as without a light source. © 2013 Astro Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the bleaching efficacy of 35% hydrogen peroxide and 15% hydrogen peroxide with nitrogen-doped titanium dioxide catalysed by an LED-laser hybrid light. We studied 70 patients randomized to two groups. Tooth shade and pulpal sensitivity were registered. Group 1: 15% hydrogen peroxide with nitrogen-doped titanium dioxide. Group 2: 35% hydrogen peroxide. Both groups were activated by an LED-laser light. No significant differences were seen in shade change immediately, one week or one month after treatment (p > 0.05). Differences were seen in pulpal sensitivity (p < 0.05). The use of an LED-laser hybrid light to activate 15% hydrogen peroxide gel with N_TiO2 permits decreasing the peroxide concentration with similar aesthetic results and less pulpal sensitivity than using 35% hydrogen peroxide for bleaching teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FEA simulation of thermal metal cutting is central to interactive design and manufacturing. It is therefore relevant to assess the applicability of FEA open software to simulate 2D heat transfer in metal sheet laser cuts. Application of open source code (e.g. FreeFem++, FEniCS, MOOSE) makes possible additional scenarios (e.g. parallel, CUDA, etc.), with lower costs. However, a precise assessment is required on the scenarios in which open software can be a sound alternative to a commercial one. This article contributes in this regard, by presenting a comparison of the aforementioned freeware FEM software for the simulation of heat transfer in thin (i.e. 2D) sheets, subject to a gliding laser point source. We use the commercial ABAQUS software as the reference to compare such open software. A convective linear thin sheet heat transfer model, with and without material removal is used. This article does not intend a full design of computer experiments. Our partial assessment shows that the thin sheet approximation turns to be adequate in terms of the relative error for linear alumina sheets. Under mesh resolutions better than 10e−5 m , the open and reference software temperature differ in at most 1 % of the temperature prediction. Ongoing work includes adaptive re-meshing, nonlinearities, sheet stress analysis and Mach (also called ‘relativistic’) effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Hirsutism occurs in 5% to 10% of women of reproductive age when there is excessive terminal hair growth in androgen-sensitive areas (male pattern). It is a distressing disorder with a major impact on quality of life. The most common cause is polycystic ovary syndrome. There are many treatment options, but it is not clear which are most effective. OBJECTIVES To assess the effects of interventions (except laser and light-based therapies alone) for hirsutism. SEARCH METHODS We searched the Cochrane Skin Group Specialised Register, CENTRAL (2014, Issue 6), MEDLINE (from 1946), EMBASE (from 1974), and five trials registers, and checked reference lists of included studies for additional trials. The last search was in June 2014. SELECTION CRITERIA Randomised controlled trials (RCTs) in hirsute women with polycystic ovary syndrome, idiopathic hirsutism, or idiopathic hyperandrogenism. DATA COLLECTION AND ANALYSIS Two independent authors carried out study selection, data extraction, 'Risk of bias' assessment, and analyses. MAIN RESULTS We included 157 studies (sample size 30 to 80) comprising 10,550 women (mean age 25 years). The majority of studies (123/157) were 'high', 30 'unclear', and four 'low' risk of bias. Lack of blinding was the most frequent source of bias. Treatment duration was six to 12 months. Forty-eight studies provided no usable or retrievable data, i.e. lack of separate data for hirsute women, conference proceedings, and losses to follow-up above 40%.Primary outcomes, 'participant-reported improvement of hirsutism' and 'change in health-related quality of life', were addressed in few studies, and adverse events in only half. In most comparisons there was insufficient evidence to determine if the number of reported adverse events differed. These included known adverse events: gastrointestinal discomfort, breast tenderness, reduced libido, dry skin (flutamide and finasteride); irregular bleeding (spironolactone); nausea, diarrhoea, bloating (metformin); hot flushes, decreased libido, vaginal dryness, headaches (gonadotropin-releasing hormone (GnRH) analogues)).Clinician's evaluation of hirsutism and change in androgen levels were addressed in most comparisons, change in body mass index (BMI) and improvement of other clinical signs of hyperandrogenism in one-third of studies.The quality of evidence was moderate to very low for most outcomes.There was low quality evidence for the effect of two oral contraceptive pills (OCPs) (ethinyl estradiol + cyproterone acetate versus ethinyl estradiol + desogestrel) on change from baseline of Ferriman-Gallwey scores. The mean difference (MD) was -1.84 (95% confidence interval (CI) -3.86 to 0.18).There was very low quality evidence that flutamide 250 mg, twice daily, reduced Ferriman-Gallwey scores more effectively than placebo (MD -7.60, 95% CI -10.53 to -4.67 and MD -7.20, 95% CI -10.15 to -4.25). Participants' evaluations in one study with 20 participants confirmed these results (risk ratio (RR) 17.00, 95% CI 1.11 to 259.87).Spironolactone 100 mg daily was more effective than placebo in reducing Ferriman-Gallwey scores (MD -7.69, 95% CI -10.12 to -5.26) (low quality evidence). It showed similar effectiveness to flutamide in two studies (MD -1.90, 95% CI -5.01 to 1.21 and MD 0.49, 95% CI -1.99 to 2.97) (very low quality evidence), as well as to finasteride in two studies (MD 1.49, 95% CI -0.58 to 3.56 and MD 0.40, 95% CI -1.18 to 1.98) (low quality evidence).Although there was very low quality evidence of a difference in reduction of Ferriman-Gallwey scores for finasteride 5 mg to 7.5 mg daily versus placebo (MD -5.73, 95% CI -6.87 to -4.58), it was unlikely it was clinically meaningful. These results were reinforced by participants' assessments (RR 2.06, 95% CI 0.99 to 4.29 and RR 11.00, 95% CI 0.69 to 175.86). However, finasteride showed inconsistent results in comparisons with other treatments, and no firm conclusions could be reached.Metformin demonstrated no benefit over placebo in reduction of Ferriman-Gallwey scores (MD 0.05, 95% CI -1.02 to 1.12), but the quality of evidence was low. Results regarding the effectiveness of GnRH analogues were inconsistent, varying from minimal to important improvements.We were unable to pool data for OCPs with cyproterone acetate 20 mg to 100 mg due to clinical and methodological heterogeneity between studies. However, addition of cyproterone acetate to OCPs provided greater reductions in Ferriman-Gallwey scores.Two studies, comparing finasteride 5 mg and spironolactone 100 mg, did not show differences in participant assessments and reduction of Ferriman-Gallwey scores (low quality evidence). Ferriman-Gallwey scores from three studies comparing flutamide versus metformin could not be pooled (I² = 62%). One study comparing flutamide 250 mg twice daily with metformin 850 mg twice daily for 12 months, which reached a higher cumulative dosage than two other studies evaluating this comparison, showed flutamide to be more effective (MD -6.30, 95% CI -9.83 to -2.77) (very low quality evidence). Data showing reductions in Ferriman-Gallwey scores could not be pooled for four studies comparing finasteride with flutamide as the results were inconsistent (I² = 67%).Studies examining effects of hypocaloric diets reported reductions in BMI, but which did not result in reductions in Ferriman-Gallwey scores. Although certain cosmetic measures are commonly used, we did not identify any relevant RCTs. AUTHORS' CONCLUSIONS Treatments may need to incorporate pharmacological therapies, cosmetic procedures, and psychological support. For mild hirsutism there is evidence of limited quality that OCPs are effective. Flutamide 250 mg twice daily and spironolactone 100 mg daily appeared to be effective and safe, albeit the evidence was low to very low quality. Finasteride 5 mg daily showed inconsistent results in different comparisons, therefore no firm conclusions can be made. As the side effects of antiandrogens and finasteride are well known, these should be accounted for in any clinical decision-making. There was low quality evidence that metformin was ineffective for hirsutism and although GnRH analogues showed inconsistent results in reducing hirsutism they do have significant side effects.Further research should consist of well-designed, rigorously reported, head-to-head trials examining OCPs combined with antiandrogens or 5α-reductase inhibitor against OCP monotherapy, as well as the different antiandrogens and 5α-reductase inhibitors against each other. Outcomes should be based on standardised scales of participants' assessment of treatment efficacy, with a greater emphasis on change in quality of life as a result of treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This in vitro study aimed to determine whether the micro-hardness of a composite resin is modified by the light units or by the thickness of the increment. Composite resin disks were divided into 15 groups (n = 5), according to the factors under study: composite resin thickness (0 mm, 1 mm, 2 mm , 3 mm and 4 mm) and light units. The light activation was performed with halogen light (HL) (40 s, 500 mW/cm(2)), argon ion laser (AL) (30 s, 600 mW/cm(2)) or light-emitting diode (LED) (30 s, 400 mW/cm(2)). Vickers micro-hardness tests were performed after 1 week and were carried out on the top surface (0 mm-control) and at different depths of the samples. Analysis of variance (ANOVA) and Tukey tests (P a parts per thousand currency signaEuro parts per thousand 0.05) revealed no statistically significant difference among the light units for the groups of 0 mm and 1 mm thickness. At 2 mm depth, the AL was not statistically different from the HL, but the latter showed higher micro-hardness values than the LED. In groups with 3 mm and 4 mm thickness, the HL also showed higher micro-hardness values than the groups activated by the AL and the LED. Only the HL presented satisfactory polymerization with 3 mm of thickness. With a 4 mm increment no light unit was able to promote satisfactory polymerization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal characterizations of high power light emitting diodes (LEDs) and laser diodes (LDs) are one of the most critical issues to achieve optimal performance such as center wavelength, spectrum, power efficiency, and reliability. Unique electrical/optical/thermal characterizations are proposed to analyze the complex thermal issues of high power LEDs and LDs. First, an advanced inverse approach, based on the transient junction temperature behavior, is proposed and implemented to quantify the resistance of the die-attach thermal interface (DTI) in high power LEDs. A hybrid analytical/numerical model is utilized to determine an approximate transient junction temperature behavior, which is governed predominantly by the resistance of the DTI. Then, an accurate value of the resistance of the DTI is determined inversely from the experimental data over the predetermined transient time domain using numerical modeling. Secondly, the effect of junction temperature on heat dissipation of high power LEDs is investigated. The theoretical aspect of junction temperature dependency of two major parameters – the forward voltage and the radiant flux – on heat dissipation is reviewed. Actual measurements of the heat dissipation over a wide range of junction temperatures are followed to quantify the effect of the parameters using commercially available LEDs. An empirical model of heat dissipation is proposed for applications in practice. Finally, a hybrid experimental/numerical method is proposed to predict the junction temperature distribution of a high power LD bar. A commercial water-cooled LD bar is used to present the proposed method. A unique experimental setup is developed and implemented to measure the average junction temperatures of the LD bar. After measuring the heat dissipation of the LD bar, the effective heat transfer coefficient of the cooling system is determined inversely. The characterized properties are used to predict the junction temperature distribution over the LD bar under high operating currents. The results are presented in conjunction with the wall-plug efficiency and the center wavelength shift.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we propose the development of a stereo SLS system for underwater inspection operations. We demonstrate how to perform a SLS calibration both in dry and underwater environments using two different methods. The proposed methodology is able to achieve quite accurate results, lower than 1 mm in dry environments. We also display a 3D underwater scan of a known object size, a sea scallop, where the system is able to perform a scan with a global error lower than 2% of the object size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena oli karakterisoida kuluttajapakkauskartonkien laserleikattavuutta. Kirjallisuusosassa perehdyttiin asiaa käsittelevään kirjallisuuteen ja tutkimuksiin ja kokeellisessa osassa käsiteltiin kuitumateriaalien laserleikkausta erilaisin leikkausparametrein. Leikattujen näytteiden leikkausrailosta otetuista mikroskooppikuvista määritettiin leikkausrailon uraleveys, purseen ja mustumisen määrä. Työssä tutkitut materiaalit olivat koivu- ja mäntysellu, CTMP, päällystämätön ja päällystetty sellukartonki sekä päällystämätön CTMP-runkoinen nestepakkauskartonki. Työssä havaittiin, että tutkitut kuitumateriaalit soveltuivat erinomaisesti laserleikkaukseen. Leikattujen kuitumateriaalinäytteiden leikkausrailo oli hyvälaatuinen eli leikkausrailo oli kapea, täydellisesti näytteen lävitse, tasainen reunoiltaan, väriltään vaalea ( ei hiiltynyt ) ja ei sisältänyt railon reunassa pystyssä olevia katkenneita kuituja ( pursetta ). Työssä todettiin myös, että kuitumateriaaleja laserleikatessa leikkausnopeus ja laserteho riippuivat lineaarisesti toisistaan. Leikkausnopeuden kasvaessa tarvittiin enemmän lasertehoa hyvälaatuisen leikkausrailon saavuttamiseksi. Tällöin leikkausuran leveys pysyi lähes vakiona. Lisäksi huomattiin, että optimisijainti polttopisteelle olisi 0.1-0.4 mm materiaalin pinnan yläpuolella, vaikka kirjallisuudesta löydettiin suosituksia sijoittaa polttopiste materiaalin pinnan alapuolelle. Näillä polttopisteen sijainnin arvoilla saavutettiin suurimmat leikkausnopeudet ja kapeimmat urat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser cutting implementation possibilities into paper making machine was studied as the main objective of the work. Laser cutting technology application was considered as a replacement tool for conventional cutting methods used in paper making machines for longitudinal cutting such as edge trimming at different paper making process and tambour roll slitting. Laser cutting of paper was tested in 70’s for the first time. Since then, laser cutting and processing has been applied for paper materials with different level of success in industry. Laser cutting can be employed for longitudinal cutting of paper web in machine direction. The most common conventional cutting methods include water jet cutting and rotating slitting blades applied in paper making machines. Cutting with CO2 laser fulfils basic requirements for cutting quality, applicability to material and cutting speeds in all locations where longitudinal cutting is needed. Literature review provided description of advantages, disadvantages and challenges of laser technology when it was applied for cutting of paper material with particular attention to cutting of moving paper web. Based on studied laser cutting capabilities and problem definition of conventional cutting technologies, preliminary selection of the most promising application area was carried out. Laser cutting (trimming) of paper web edges in wet end was estimated to be the most promising area where it can be implemented. This assumption was made on the basis of rate of web breaks occurrence. It was found that up to 64 % of total number of web breaks occurred in wet end, particularly in location of so called open draws where paper web was transferred unsupported by wire or felt. Distribution of web breaks in machine cross direction revealed that defects of paper web edge was the main reason of tearing initiation and consequent web break. The assumption was made that laser cutting was capable of improvement of laser cut edge tensile strength due to high cutting quality and sealing effect of the edge after laser cutting. Studies of laser ablation of cellulose supported this claim. Linear energy needed for cutting was calculated with regard to paper web properties in intended laser cutting location. Calculated linear cutting energy was verified with series of laser cutting. Practically obtained laser energy needed for cutting deviated from calculated values. This could be explained by difference in heat transfer via radiation in laser cutting and different absorption characteristics of dry and moist paper material. Laser cut samples (both dry and moist (dry matter content about 25-40%)) were tested for strength properties. It was shown that tensile strength and strain break of laser cut samples are similar to corresponding values of non-laser cut samples. Chosen method, however, did not address tensile strength of laser cut edge in particular. Thus, the assumption of improving strength properties with laser cutting was not fully proved. Laser cutting effect on possible pollution of mill broke (recycling of trimmed edge) was carried out. Laser cut samples (both dry and moist) were tested on the content of dirt particles. The tests revealed that accumulation of dust particles on the surface of moist samples can take place. This has to be taken into account to prevent contamination of pulp suspension when trim waste is recycled. Material loss due to evaporation during laser cutting and amount of solid residues after cutting were evaluated. Edge trimming with laser would result in 0.25 kg/h of solid residues and 2.5 kg/h of lost material due to evaporation. Schemes of laser cutting implementation and needed laser equipment were discussed. Generally, laser cutting system would require two laser sources (one laser source for each cutting zone), set of beam transfer and focusing optics and cutting heads. In order to increase reliability of system, it was suggested that each laser source would have double capacity. That would allow to perform cutting employing one laser source working at full capacity for both cutting zones. Laser technology is in required level at the moment and do not require additional development. Moreover, capacity of speed increase is high due to availability high power laser sources what can support the tendency of speed increase of paper making machines. Laser cutting system would require special roll to maintain cutting. The scheme of such roll was proposed as well as roll integration into paper making machine. Laser cutting can be done in location of central roll in press section, before so-called open draw where many web breaks occur, where it has potential to improve runability of a paper making machine. Economic performance of laser cutting was done as comparison of laser cutting system and water jet cutting working in the same conditions. It was revealed that laser cutting would still be about two times more expensive compared to water jet cutting. This is mainly due to high investment cost of laser equipment and poor energy efficiency of CO2 lasers. Another factor is that laser cutting causes material loss due to evaporation whereas water jet cutting almost does not cause material loss. Despite difficulties of laser cutting implementation in paper making machine, its implementation can be beneficial. The crucial role in that is possibility to improve cut edge strength properties and consequently reduce number of web breaks. Capacity of laser cutting to maintain cutting speeds which exceed current speeds of paper making machines what is another argument to consider laser cutting technology in design of new high speed paper making machines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physical parameters of different types of lenses were measured through digital speckle pattern interferometry (DSPI) using a multimode diode laser as light source. When such lasers emit two or more longitudinal modes simultaneously the speckle image of an object appears covered of contour fringes. By performing the quantitative fringe evaluation the radii of curvature as well as the refractive indexes of the lenses were determined. The fringe quantitative evaluation was carried out through the four- and the eight-stepping techniques and the branch-cut method was employed for phase unwrapping. With all these parameters the focal length was calculated. This whole-field multi-wavelength method does enable the characterization of spherical and aspherical lenses and of positive and negative ones as well. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Decision making is one of the most important factors for growth and future, both from a business, as in people's life and attitudes in the simplest of everyday day. This work aims to assist decision making in buying a laser cut machine, a manufacturer of auto parts and wheels, and later this technique can be considered to acquisition of other equipment. In this case was used the AHP to aid the decision by multiple criteria. First we analyzed the most important criteria of the current machine for the application of the method and were later made the application and sensitivity analysis