587 resultados para knife coulter


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large fat globules that can be present in UHT milk due to inadequate homogenisation cause a cream layer to form that limits the shelf life of UHT milk. Four different particle size measurement techniques were used to measure the size of fat globules in poorly homogenised UHT milk processed in a UHT pilot plant. The thickness of the cream layer that formed during storage was negatively correlated with homogenisation pressure. It was positively correlated with the mass mean diameter and the percentage volume of particles between 1.5 and 2 mu m diameter, as determined by laser light scattering using the Malvern Mastersizer. Also, the thickness of the cream layer was positively correlated with the volume mode diameter and the percentage volume of particles between 1.5 and 2 mu m diameter, as determined by electrical impedance using the Coulter Counter. The cream layer thickness did not correlate significantly with the Coulter Counter measurements of volume mean diameter, or volume percentages of particles between 2 and 5 mu m or 5 and 10 mu m diameter. Spectroturbidimetry (Emulsion Quality Analyser) and light microscopy analyses were found to be unsuitable for assessing the size of the fat particles. This study suggests that the fat globule size distribution as determined by the electrical impedance method (Coulter Counter) is the most useful for determining the efficiency of homogenisation and therefore for predicting the stability of the fat emulsion in UHT milk during storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the safety-efficacy of Gamma Knife surgery (GKS) as a second treatment for classical trigeminal neuralgia (CTN), and the influence of prior microvascular decompression (MVD). Methods: Between July 1992 and November 2010, 737 patients have been operated with GKRS for ITN and prospectively evaluated in Timone University Hospital in Marseille, France. Among these, 54 patients had a previous history of MVD. Radiosurgery using a Gamma Knife (model B or C or Perfexion) was performed on the basis of on both MR and CT targeting. A single 4 mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.6 mm (range 3.9-11.9) anteriorly to the emergence of the nerve (retrogasserian target). A median maximum dose of 85 Gy (range 70-90) was delivered. Here, the 45 patients with previous MVD and a follow-up longer than one year are evaluated (the patients with megadolichobasilar artery compression and multiple sclerosis were excluded). Results: The median age in this series was 56.75 years (range 28.09-82.39). The median follow-up period was 39.48 months (range 14.10-144.65). All the patients had a past history of surgery, with at least one previous failed MVD, but also radiofrequency lesion (RFL) in 16 patients (35.6%), balloon microcompression in 7 (15.6%) and glycerol rhizotomy in 1 (2.2%). Thirty-five patients (77.8%) were initially pain free after GKS within a median time of 14 days (range 0, 180). Patients from this group had less probability of being pain free compared to our global population of essential trigeminal neuralgia without previous MVD history (p=0.010, hazard ratio of 0.64). Their probability of remaining pain free at 3, 5, 7 and 10 years was 66.5%, 59.1%, 59.1% and 44.3%, respectively. Twelve patients (34.3%) initially pain free experienced a recurrence with a median delay of 31.21 months (range 3.40-89.93). The hypoesthesia actuarial rate at 1 year was 9.1% and remained stable till 12 years with a median delay of onset of 8 months (range 8-8). Conclusions: Retrogasserian GKS proofed to be safe and effective on the long-term basis even after failed previous MVD. Even if the initial result of pain free was only 77.8%, the toxicity was low with only 9.1% hypoesthesia. No patient reported a bothersome hypoesthesia. The probability of maintaining pain relief in the long-term was of 44.3% at 10 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object The purpose of this study was to establish the safety and efficacy of repeat Gamma Knife surgery (GKS) for recurrent trigeminal neuralgia (TN). Methods Using the prospective database of TN patients treated with GKS in Timone University Hospital (Marseille, France), data were analyzed for 737 patients undergoing GKS for TN Type 1 from July 1992 to November 2010. Among the 497 patients with initial pain cessation, 34.4% (157/456 with ≥ 1-year follow-up) experienced at least 1 recurrence. Thirteen patients (1.8%) were considered for a second GKS, proposed only if the patients had good and prolonged initial pain cessation after the first GKS, with no other treatment alternative at the moment of recurrence. As for the first GKS, a single 4-mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.6 mm (range 4-14 mm) anterior to the emergence of the nerve (retrogasserian target). A median maximum dose of 90 Gy (range 70-90 Gy) was delivered. Data for 9 patients with at least 1-year followup were analyzed. A systematic review of literature was also performed, and results are compared with those of the Marseille study. Results The median time to retreatment in the Marseille study was 72 months (range 12-125 months) and in the literature it was 17 months (range 3-146 months). In the Marseille study, the median follow-up period was 33.9 months (range 12-96 months), and 8 of 9 patients (88.9%) had initial pain cessation with a median of 6.5 days (range 1-180 days). The actuarial rate for new hypesthesia was 33.3% at 6 months and 50% at 1 year, which remained stable for 7 years. The actuarial probabilities of maintaining pain relief without medication at 6 months and 1 year were 100% and 75%, respectively, and remained stable for 7 years. The systematic review analyzed 20 peer-reviewed studies reporting outcomes for repeat GKS for recurrent TN, with a total of 626 patients. Both the selection of the cases for retreatment and the way of reporting outcomes vary widely among studies, with a median rate for initial pain cessation of 88% (range 60%-100%) and for new hypesthesia of 33% (range 11%-80%). Conclusions Results from the Marseille study raise the question of surgical alternatives after failed GKS for TN. The rates of initial pain cessation and recurrence seem comparable to, or even better than, those of the first GKS, according to different studies, but toxicity is much higher, both in the Marseille study and in the published data. Neither the Marseille study data nor literature data answer the 3 cardinal questions regarding repeat radiosurgery in recurrent TN: which patients to retreat, which target is optimal, and which dose to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of reviewThis review provides information and an update on stereotactic radiosurgery (SRS) equipment, with a focus on intracranial lesions and brain neoplasms.Recent findingsGamma Knife radiosurgery represents the gold standard for intracranial radiosurgery, using a dedicated equipment, and has recently evolved with a newly designed technology, Leksell Gamma Knife Perfexion. Linear accelerator-based radiosurgery is more recent, and originally based on existing systems, either adapted or dedicated to radiosurgery. Equipment incorporating specific technologies, such as the robotic CyberKnife system, has been developed. Novel concepts in radiation therapy delivery techniques, such as intensity-modulated radiotherapy, were also developed; their integration with computed tomography imaging and helical delivery has led to the TomoTherapy system. Recent data on the management of intracranial tumors with radiosurgery illustrate the trend toward a larger use and acceptance of this therapeutic modality.SummarySRS has become an important alternative treatment for a variety of lesions. Each radiosurgery system has its advantages and limitations. The 'perfect' and ubiquitous system does not exist. The choice of a radiosurgery system may vary with the strategy and needs of specific radiosurgery programs. No center can afford to acquire every technology, and strategic choices have to be made. Institutions with large neurosurgery and radiation oncology programs usually have more than one system, allowing optimization of the management of patients with a choice of open neurosurgery, radiosurgery, and radiotherapy. Given its minimally invasive nature and increasing clinical acceptance, SRS will continue to progress and offer new advances as a therapeutic tool in neurosurgery and radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes targeting of the ventro-intermediate nucleus of the thalamus (e.g. Vim) for tremor. We currently perform an indirect targeting, as the Vim is not visible on current 3Tesla MRI acquisitions. Our objective was to enhance anatomic imaging (aiming at refining the precision of anatomic target selection by direct visualisation) in patients treated for tremor with Vim GKS, by using high field 7T MRI. MATERIALS AND METHODSH: Five young healthy subjects were scanned on 3 (T1-w and diffusion tensor imaging) and 7T (high-resolution susceptibility weighted images (SWI)) MRI in Lausanne. All images were further integrated for the first time into the Gamma Plan Software(®) (Elekta Instruments, AB, Sweden) and co-registered (with T1 was a reference). A simulation of targeting of the Vim was done using various methods on the 3T images. Furthermore, a correlation with the position of the found target with the 7T SWI was performed. The atlas of Morel et al. (Zurich, CH) was used to confirm the findings on a detailed analysis inside/outside the Gamma Plan. RESULTS: The use of SWI provided us with a superior resolution and an improved image contrast within the basal ganglia. This allowed visualization and direct delineation of some subgroups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed on 3T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim-target area was created on the basis of the obtained images. CONCLUSION: This is the first report of the integration of SWI high field MRI into the LGP, aiming at the improvement of targeting validation of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g. quadrilatere of Guyot, histological atlases) seems to show a very good anatomical matching. Further studies are needed to validate this technique, both by improving the accuracy of the targeting of the Vim (potentially also other thalamic nuclei) and to perform clinical assessment.