989 resultados para joint motion sense
Resumo:
Changes in the position of the head and neck have been shown to introduce a systematic deviation in the end-point error of an upper limb pointing task. Although previous authors have attributed this to alteration of perceived target location, no studies have explored the effect of changes in head and neck position on the perception of limb position. This study investigated whether changes in head and neck position affect a specific component of movement performance, that is, the accuracy of joint position sense (JPS) at the elbow. Elbow JPS was tested with the neck in four positions: neutral, flexion, rotation and combined flexion/rotation. A target angle was presented passively with the neck in neutral, after a rest period; this angle was reproduced actively with the head and neck in one of the test positions. The potential effects of distraction from head movement were controlled for by performing a movement control in which the head and neck were in neutral for the presentation and reproduction of the target angle, but moved into flexion during the rest period. The absolute and variable joint position errors (JPE) were greater when the target angle was reproduced with the neck in the flexion, rotation, and combined flexion/rotation than when the head and neck were in neutral. This study suggests that the reduced accuracy previously seen in pointing tasks with changes in head position may be partly because of errors in the interpretation of arm position.
Resumo:
Background: It has been shown that perception of elbow joint position is affected by changes in head and neck position. Further, people with whiplash-associated disorders (WAD) present with deficits in upper limb coordination and movement. Objectives: This study is aimed to determine whether the effect of changes in head position on elbow joint position error (JPE) is more pronounced in people with WAD, and to determine whether this is related to the participant's pain and anxiety levels. Methods: Nine people with chronic and disabling WAD and 11 healthy people participated in this experiment. The ability to reproduce a position at the elbow joint was assessed after changes in the position of the head and neck to 30 degrees, and with the head in the midline. Pain was monitored in WAD participants. Results: Absolute elbow JPE with the head in neutral was not different between WAD and control participants (P = 0.5). Changes in the head and neck position increased absolute elbow JPE in the WAD group (P < 0.05), but did not affect elbow JPE in the control group (P = 0.4). There was a connection between pain during testing and the effect of changes in head position on elbow JPE (P < 0.05). Discussion: Elbow JPE is affected by movement of the head and neck, with smaller angles of neck rotation in people with WAD than in healthy individuals. This observation may explain deficits in upper limb coordination in people with WAD, which may be due to the presence of pain or reduced range of motion in this population.
Resumo:
Knee joint-position sensitivity has been shown to decline with increasing age, with much of the research reported in the literature investigating this age effect in non-weight-bearing (NWB) conditions. However, little data is available in the more functional position of weight-bearing conditions. The objective of this study was to identify the influence of age on the accuracy and nature of knee joint-position sense (JPS) in both full weight-bearing (FWB) and partial weight-bearing (PWB) conditions and to determine the effect of lower-extremity dominance on knee JPS. Sixty healthy subjects from three age groups (young: 20-35 years old, middle-aged: 40-55 years, and older: 60-75 years) were assessed. Tests were conducted on both the right and left legs to examine the ability of subjects to correctly reproduce knee angles in an active criterion-active repositioning paradigm. Knee angles were measured in degrees using an electromagnetic tracking device, Polhemus 3Space Fastrak, that detected positions of sensors placed on the test limb. Errors in FWB knee joint repositioning did not increase with age, but significant age-related increases in knee joint-repositioning error were found in PWB. It was found that elderly subjects tended to overshoot the criterion angle more often than subjects from the young and middle-aged groups. Subjects in all three age groups performed better in FWB than in PWB. Differences between the stance-dominant (STD) and skill-dominant (SKD) legs did not reach significance. Results demonstrated that for, normal pain-free individuals, there is no age-related decline in knee JPS in FWB, although an age effect does exist in PWB. This outcome challenges the current view that a generalised decline in knee joint proprioception occurs with age. In addition, lower-limb dominance is not a factor in acuity of knee JPS.
Resumo:
Superseded by TM 8-640, Jan. 1968.
Resumo:
Purpose. The ability to sense the position of limb segments is a highly specialised proprioceptive function important for control of movement. Abnormal knee proprioception has been found in association with several musculoskeletal pathologies but whether nociceptive Stimulation can produce these proprioceptive changes is unclear. This study evaluated the effect of experimentally induced knee pain on knee joint position sense (JPS) in healthy individuals. Study design. Repeated measures, within-subject design. Methods. Knee JPS was tested in 16 individuals with no history of knee pathology under three experimental conditions: baseline control, a distraction task and knee pain induced by injection of hypertonic saline into the infrapatellar fat pad. Knee JPS was measured using active ipsilateral limb matching responses at 20degrees and 60degrees flexion whilst non-weightbearing (NWB) and 20degrees flexion single leg stance. During the tasks, the subjective perception of distraction and severity of pain were measured using 11-point numerical rating scales. Results. Knee JPS was not altered by acute knee pain in any of the positions tested. The distraction task resulted in poorer concentration, greater JPS absolute errors at 20degrees NWB, and greater variability in errors during the WB tests. There were no significant correlations between levels of pain and changes in JPS errors. Changes in JPS with pain and distraction were inversely related to baseline knee JPS variable error in all test positions (r = -0.56 to -0.91) but less related to baseline absolute error. Conclusion. Knee JPS is reduced by an attention-demanding task but not by experimentally induced pain. (C) 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
Context: Clinicians use exercises in rehabilitation to enhance sensorimotor-function, however evidence supporting their use is scarce. Objective: To evaluate acute effects of handheld-vibration on joint position sense (JPS). Design: A repeated-measure, randomized, counter-balanced 3-condition design. Setting: Sports Medicine and Science Research Laboratory. Patients or Other Participants: 31 healthy college-aged volunteers (16-males, 15-females; age=23+3y, mass=76+14kg, height=173+8cm). Interventions: We measured elbow JPS and monitored training using the Flock-of-Birds system (Ascension Technology, Burlington, VT) and MotionMonitor software (Innsport, Chicago, IL), accurate to 0.5°. For each condition (15,5,0Hz vibration), subjects completed three 15-s bouts holding a 2.55kg Mini-VibraFlex dumbbell (Orthometric, New York, NY), and used software-generated audio/visual biofeedback to locate the target. Participants performed separate pre- and post-test JPS measures for each condition. For JPS testing, subjects held a non-vibrating dumbbell, identified the target (90°flexion) using biofeedback, and relaxed 3-5s. We removed feedback and subjects recreated the target and pressed a trigger. We used SPSS 14.0 (SPSS Inc., Chicago, IL) to perform separate ANOVAs (p<0.05) for each protocol and calculated effect sizes using standard-mean differences. Main Outcome Measures: Dependent variables were absolute and variable error between target and reproduced angles, pre-post vibration training. Results: 0Hz (F1,61=1.310,p=0.3) and 5Hz (F1,61=2.625,p=0.1) vibration did not affect accuracy. 15Hz vibration enhanced accuracy (6.5±0.6 to 5.0±0.5°) (F1,61=8.681,p=0.005,ES=0.3). 0Hz did not affect variability (F1,61=0.007,p=0.9). 5Hz vibration decreased variability (3.0±1.8 to 2.3±1.3°) (F1,61=7.250,p=0.009), as did 15Hz (2.8±1.8 to 1.8±1.2°) (F1,61=24.027, p<0.001). Conclusions: Our results support using handheld-vibration to improve sensorimotor-function. Future research should include injured subjects, functional multi-joint/multi-planar measures, and long-term effects of similar training.
Resumo:
The study of the influence of motion and initial intra-articular pressure (IAP) on intra-articular pressure profiles in equine cadaver metatarsophalangeal (MTP) joints was undertaken as a prelude to in vivo studies, Eleven equine cadaver MTP joints were submitted to 2 motion frequencies of 5 and 10 cycles/min of flexion and extension, simulating the condition of lower and higher (double) rates of passive motion. These frequencies were applied and pressure profiles generated with initial normal intra-articular pressure (-5 mmHg) and subsequently 30 mmHg intra-articular pressure obtained by injection of previously harvested synovial fluid.The 4 trials performed were 1) normal IAP; 5 cyles/min; 2) normal IAP; 10 cycles/min; 3) IAP at 30 mmHg; 5 cycles/min and 4) IAP at 30 mmHg; 10 cycles/min. The range of joint motion applied (mean +/- s.e.) was 67.6 +/- 1.61 degrees with an excursion from 12.2 +/- 1.2 degrees in extension to 56.2 +/- 2.6 degrees in flexion, Mean pressure recorded in mmHg for the first and last min of each trial, respectively, were 1) -5.7 +/- 0.9 and -6.3 +/- 1.1; 2) -5.3 +/- 1.1 and -6.2 +/- 1.1; 3) 58.8 +/- 8.0 and 42.3 +/- 7.2; 4) 56.6 +/- 3.7 and 40.3 +/- 4.6. Statistical analyses showed a trend for difference between the values for the first and last minute in trial 3 (0.05>P<0.1) with P = 0.1 and significant difference (P = 0.02) between the mean IAP of the first and last min in trial 4. The loss of intra-articular pressure associated with time and motion was 10.5, 16.9, 28.1 and 28.9% for trials 1-4, respectively. As initial intraarticular pressure and motion increased, the percent loss of intra-articular pressure increased.The angle of lowest pressure was 12.2 +/- 1.2
Resumo:
This thesis describes the process of design and modeling of instrument for knee joint kinematics measurement that can work for both in-vivo and in-vitro subjects. It is designed to be compatible with imaging machine in a sagittal plane. Due to the invasiveness of the imaging machine, the instrument is designed to be able to function independently. The flexibility of this instrument allows to measure anthropometrically different subject. Among the sixth degree of freedom of a knee, three rotational and one translational degree of freedom can be measured for both type of subject. The translational, proximal-distal, motion is stimulated by external force directly applied along its axis. These angular and linear displacements are measured by magnetic sensors and high precision potentiometers respectively
Resumo:
In this thesis we consider systems of finitely many particles moving on paths given by a strong Markov process and undergoing branching and reproduction at random times. The branching rate of a particle, its number of offspring and their spatial distribution are allowed to depend on the particle's position and possibly on the configuration of coexisting particles. In addition there is immigration of new particles, with the rate of immigration and the distribution of immigrants possibly depending on the configuration of pre-existing particles as well. In the first two chapters of this work, we concentrate on the case that the joint motion of particles is governed by a diffusion with interacting components. The resulting process of particle configurations was studied by E. Löcherbach (2002, 2004) and is known as a branching diffusion with immigration (BDI). Chapter 1 contains a detailed introduction of the basic model assumptions, in particular an assumption of ergodicity which guarantees that the BDI process is positive Harris recurrent with finite invariant measure on the configuration space. This object and a closely related quantity, namely the invariant occupation measure on the single-particle space, are investigated in Chapter 2 where we study the problem of the existence of Lebesgue-densities with nice regularity properties. For example, it turns out that the existence of a continuous density for the invariant measure depends on the mechanism by which newborn particles are distributed in space, namely whether branching particles reproduce at their death position or their offspring are distributed according to an absolutely continuous transition kernel. In Chapter 3, we assume that the quantities defining the model depend only on the spatial position but not on the configuration of coexisting particles. In this framework (which was considered by Höpfner and Löcherbach (2005) in the special case that branching particles reproduce at their death position), the particle motions are independent, and we can allow for more general Markov processes instead of diffusions. The resulting configuration process is a branching Markov process in the sense introduced by Ikeda, Nagasawa and Watanabe (1968), complemented by an immigration mechanism. Generalizing results obtained by Höpfner and Löcherbach (2005), we give sufficient conditions for ergodicity in the sense of positive recurrence of the configuration process and finiteness of the invariant occupation measure in the case of general particle motions and offspring distributions.
Resumo:
The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. In-vitro tests are important in order to analyse knee behavior when simulating various loading conditions and studying physiology of the joint. A new test rig for in-vitro evaluation of the knee joint behavior is presented in this paper. It represents the evolution of a previously proposed rig, designed to overcome its principal limitations and to improve its performances. The design procedure and the adopted solution in order to satisfy the specifications are presented here. Thanks to its 6-6 Gough-Stewart parallel manipulator loading system, the rig replicates general loading conditions, like daily actions or clinical tests, on the specimen in a wide range of flexion angles. The restraining actions of knee muscles can be simulated when active actions are simulated. The joint motion in response to the applied loads, guided by passive articular structures and muscles, is permitted by the characteristics of the loading system which is force controlled. The new test rig guarantees visibility so that motion can be measured by an optoelectronic system. Furthermore, the control system of the new test rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint by the system for muscle simulation. Accuracy in positioning is guaranteed by the designed tibia and femur fixation systems,which allow unmounting and remounting the specimen in the same pose. The test rig presented in this paper permits the analysis of the behavior of the knee joint and comparative analysis on the same specimen before and after surgery, in a way to assess the goodness of prostheses or surgical treatments.
Resumo:
A novel computerized algorithm for hip joint motion simulation and collision detection, called the Equidistant Method, has been developed. This was compared to three pre-existing methods having different properties regarding definition of the hip joint center and behavior after collision detection. It was proposed that the Equidistant Method would be most accurate in detecting the location and extent of femoroacetabular impingement.
Resumo:
Reproduction of a previously presented elbow position is affected by changes in head position. As movement of the head is associated with local biomechanical changes, the aim of the present study was to determine if illusory changes in head position could induce similar effects on the reproduction of elbow position. Galvanic vestibular stimulation (GVS) was applied to healthy subjects in supine lying. The stimulus was applied during the presentation of an elbow position, which the subject then reproduced without stimulation. In the first study, 13 subjects received 1.5 mA stimuli, which caused postural sway in standing, confirming that the firing of vestibular afferents was affected, but no illusory changes in head position were reported. In the second study, 13 subjects received 2.0-3.0 mA GVS. Six out of 13 subjects reported consistent illusory changes in head position, away from the side of the anode. In these subjects, anode right stimulation induced illusory left lateral flexion and elbow joint position error towards extension (p=0.03), while anode left tended to have the opposite effect (p=0.16). The GVS had no effect on error in subjects who did not experience illusory head movement with either 1.5 mA stimulus (p=0.8) or 2.0-3.0 mA stimulus (p=0.7). This study demonstrates that the accuracy of elbow repositioning is affected by illusory changes in head position. These results support the hypothesis that the perceived position of proximal body segments is used in the planning and performance of accurate upper limb movements.
Resumo:
This paper describes experiments conducted in order to simultaneously tune 15 joints of a humanoid robot. Two Genetic Algorithm (GA) based tuning methods were developed and compared against a hand-tuned solution. The system was tuned in order to minimise tracking error while at the same time achieve smooth joint motion. Joint smoothness is crucial for the accurate calculation of online ZMP estimation, a prerequisite for a closedloop dynamically stable humanoid walking gait. Results in both simulation and on a real robot are presented, demonstrating the superior smoothness performance of the GA based methods.