993 resultados para joint failure


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper discusses the reliability of an IGBT power electronics module. This work is part of a major UK funded initiative into the design, packaging and reliability of power electronic modules. The predictive methodology combines numerical modeling techniques with experimentation and accelerated testing to identify failure modes and mechanisms for these type of power electronic module structures. The paper details results for solder joint failure substrate solder. Finite element method modeling techniques have been used to predict the stress and strain distribution within the module structures. Together with accelerated life testing, these results have provided a failure model for these joints which has been used to predict reliability of a rail traction application

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Propionibacterium acnes and coagulase-negative staphylococci (CoNS) are opportunistic pathogens implicated in prosthetic joint and fracture fixation device-related infections. The purpose of this study was to determine whether P. acnes and the CoNS species Staphylococcus lugdunensis, isolated from an "aseptically failed" prosthetic hip joint and a united intramedullary nail-fixed tibial fracture, respectively, could cause osteomyelitis in an established implant-related osteomyelitis model in rabbits in the absence of wear debris from the implant material. The histological features of P. acnes infection in the in vivo rabbit model were consistent with localized pyogenic osteomyelitis, and a biofilm was present on all explanted intramedullary (IM) nails. The animals displayed no outward signs of infection, such as swelling, lameness, weight loss, or elevated white blood cell count. In contrast, infection with S. lugdunensis resulted in histological features consistent with both pyogenic osteomyelitis and septic arthritis, and all S. lugdunensis-infected animals displayed weight loss and an elevated white blood cell count despite biofilm detection in only two out of six rabbits. The differences in the histological and bacteriological profiles of the two species in this rabbit model of infection are reflective of their different clinical presentations: low-grade infection in the case of P. acnes and acute infection for S. lugdunensis. These results are especially important in light of the growing recognition of chronic P. acnes biofilm infections in prosthetic joint failure and nonunion of fracture fixations, which may be currently reported as "aseptic" failure. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fault tolerance of robotic manipulators is determined based on the fault tolerance measures. In this study a Jacobian of a 7DOF optimal fault tolerant manipulator is designed based on optimality of worse case relative manipulability and worse case dexterity from geometric perspective instead of numerical solution of constrained optimisation problem or construction of optimal Jacobean through a desired null space. The proposed Jacobean matrix is optimal and equally fault tolerant for a single joint failure within any joint of the manipulators.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Autonomous or teleoperation of critical tasks in space applications require fault tolerant robotic manipulators. These manipulators are able to maintain their tasks even if a joint fails. If it is presumed that the manipulator is fault tolerant on its trajectory, then the next step is to provide a fault tolerant force at the end-effector of the manipulator. The problem of cooperative fault tolerant force is addressed in this paper within the operation of two manipulators. The cooperative manipulators are used to compensate the force jump which occurs on the force of the end-effector of one manipulator due to a joint failure. To achieve fault tolerant operation, the contribution of the faulty joint for the force of the end-effector of the faulty manipulator is required to be optimally mapped into the torque of the faulty and healthy manipulators. The optimal joint torque reconfigurations of both manipulators for compensating this force jump are illustrated. The proposed frameworks are deployed for two cooperative PUMA560 manipulators. The results of the case studies validate the fault tolerant cooperation strategies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Design of locally optimal fault tolerant manipulators has been recently addressed via using the constraints of the desired null space for the Jacobian matrix of the manipulators. In the present paper the Jacobian matrices for optimal fault tolerance are presented based on geometric properties of column vectors instead of the null space. They are equally fault tolerant to a single joint failure from the worst-case relative manipulability and worst-case dexterity points of view. The optimality is achieved through a symmetric distribution of points on spheres.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty.
A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant–cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration.
Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the 19th century, firms operating in the Anglo-Indian tea trade were organised using a variety ownership forms including the partnership, joint-stock and a combination of the two known as the Managing agency. Faced with both an increasing need for fixed capital and high agency costs caused by the distance between owners and managers, the firms adapted and increasingly adopted the hybrid managing agency model to overcome these problems. Using new data from Calcutta and Bengal Commercial Registers and detailed case studies of the Assam Company and Gillanders, Arbuthnot and Co, this paper demonstrates that British entrepreneurs did not see the choice of ownership as a dichotomy or firm boundaries as fixed, but instead innovatively drew on the strengths of different forms of ownership to compete and grow successfully.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.