186 resultados para irritation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Addition of menthol to cigarettes may be associated with increased initiation of smoking. The potential mechanisms underlying this association are not known. Menthol, likely due to its effects on cold-sensing peripheral sensory neurons, is known to inhibit the sensation of irritation elicited by respiratory irritants. However, it remains unclear whether menthol modulates cigarette smoke irritancy and nicotine absorption during initial exposures to cigarettes, thereby facilitating smoking initiation. Using plethysmography in a C57Bl/6J mouse model, we examined the effects of L-menthol, the menthol isomer added to cigarettes, on the respiratory sensory irritation response to primary smoke irritants (acrolein and cyclohexanone) and smoke of Kentucky reference 2R4 cigarettes. We also studied L-menthol's effect on blood levels of the nicotine metabolite, cotinine, immediately after exposure to cigarette smoke. L-menthol suppressed the irritation response to acrolein with an apparent IC₅₀ of 4 ppm. Suppression was observed even at acrolein levels well above those necessary to produce a maximal response. Cigarette smoke, at exposure levels of 10 mg/m³ or higher, caused an immediate and marked sensory irritation response in mice. This response was significantly suppressed by L-menthol even at smoke concentrations as high as 300 mg/m³. Counterirritation by L-menthol was abolished by treatment with a selective inhibitor of Transient Receptor Potential Melastatin 8 (TRPM8), the neuronal cold/menthol receptor. Inclusion of menthol in the cigarette smoke resulted in roughly a 1.5-fold increase in plasma cotinine levels over those observed in mice exposed to smoke without added menthol. These findings document that, L-menthol, through TRPM8, is a strong suppressor of respiratory irritation responses, even during highly noxious exposures to cigarette smoke or smoke irritants, and increases blood cotinine. Therefore, L-menthol, as a cigarette additive, may promote smoking initiation and nicotine addiction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim : To determine the internalization and protective effects of potential ophthalmic formulations and nanoformulated natural proteins in ex-vivo bovine corneal alkali burn model.

Methods : The bovine cornea obtained were subjected to the 0.5 N NaOH insult that induced alkali burn and inflammation as observed in the in vivo situation. The toxic effects of the nanoformulation were evaluated in the normal and insult induced cornea using histological analysis. Internalization studies were carried out using in vivo imaging and analysis (IVIS, PerkinElmer, USA).

Results : The nanoformulations employed in this study showed no obvious changes in the integrity of the cornea. Further, improvements in the light transmittance and reduced inflammation were observed. The IVIS showed a dose dependant increase in the uptake of the nanoformulations with time.

Conclusion : The nanoformulated bovine lactoferrin and SurR9-C84A (SR9) proteins evaluated in the ex vivo bovine corneal irritation model is the first of its kind, and we report here the non-toxic and therapeutic potential of these formulations for topical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic irritation of the iliopsoas tendon is a rare cause of persistent pain after total joint replacement of the hip. In the majority of cases, pain results from a mechanical conflict between the iliopsoas tendon and the anterior edge of the acetabular cup after total hip arthroplasty. Pain can be reproduced by active flexion of the hip and by active raising of the straightened leg. In addition, painful leg raising against resistance and passive hyperextension are suggestive of an irritation of the iliopsoas tendon. Symptoms evolve from a mechanical irritation of the iliopsoas tendon and an oversized or retroverted acetabular cup, screws penetrating into the inner aspect of the ilium, or from bone cement protruding beyond the anterior acetabular rim. The diagnosis may be assumed on conventional radiographs and confirmed by CT scans. Fifteen patients with psoas irritation after total hip replacement are reported on. Eleven patients were treated surgically. The acetabular cup was revised and reoriented with more anteversion in six patients, isolated screws penetrating into the tendon were cut and leveled in three patients, and prominent bone cement in conflict with the tendon was resected once. A partial release of the iliopsoas tendon only was performed in another patient. Follow-up examination (range: 11-89 months) revealed that nine patients were free of pain and two patient had mild residual complaints. Psoas irritation in combination with total hip replacement can be prevented by a correct surgical technique, especially with proper selection of the cup size and insertion of the acetabular cup avoiding a rim position exceeding the level of the anterior acetabular rim.