875 resultados para intraclass correlation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Bayesian approach to estimating the intraclass correlation coefficient was used for this research project. The background of the intraclass correlation coefficient, a summary of its standard estimators, and a review of basic Bayesian terminology and methodology were presented. The conditional posterior density of the intraclass correlation coefficient was then derived and estimation procedures related to this derivation were shown in detail. Three examples of applications of the conditional posterior density to specific data sets were also included. Two sets of simulation experiments were performed to compare the mean and mode of the conditional posterior density of the intraclass correlation coefficient to more traditional estimators. Non-Bayesian methods of estimation used were: the methods of analysis of variance and maximum likelihood for balanced data; and the methods of MIVQUE (Minimum Variance Quadratic Unbiased Estimation) and maximum likelihood for unbalanced data. The overall conclusion of this research project was that Bayesian estimates of the intraclass correlation coefficient can be appropriate, useful and practical alternatives to traditional methods of estimation. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To compare the repeatability within anterior corneal topography measurements and agreement between measurements with the Pentacam HR rotating Scheimpflug camera and with a previously validated Placido disk–based videokeratoscope (Medmont E300). ------ SETTING: Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Queensland, Australia. ----- METHODS: Normal eyes in 101 young adult subjects had corneal topography measured using the Scheimpflug camera (6 repeated measurements) and videokeratoscope (4 repeated measurements). The best-fitting axial power corneal spherocylinder was calculated and converted into power vectors. Corneal higher-order aberrations (HOAs) (up to the 8th Zernike order) were calculated using the corneal elevation data from each instrument. ----- RESULTS: Both instruments showed excellent repeatability for axial power spherocylinder measurements (repeatability coefficients <0.25 diopter; intraclass correlation coefficients >0.9) and good agreement for all power vectors. Agreement between the 2 instruments was closest when the mean of multiple measurements was used in analysis. For corneal HOAs, both instruments showed reasonable repeatability for most aberration terms and good correlation and agreement for many aberrations (eg, spherical aberration, coma, higher-order root mean square). For other aberrations (eg, trefoil and tetrafoil), the 2 instruments showed relatively poor agreement. ----- CONCLUSIONS: For normal corneas, the Scheimpflug system showed excellent repeatability and reasonable agreement with a previously validated videokeratoscope for the anterior corneal axial curvature best-fitting spherocylinder and several corneal HOAs. However, for certain aberrations with higher azimuthal frequencies, the Scheimpflug system had poor agreement with the videokeratoscope; thus, caution should be used when interpreting these corneal aberrations with the Scheimpflug system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Few studies have evaluated the reliability of lifetime sun exposure estimated from inquiring about the number of hours people spent outdoors in a given period on a typical weekday or weekend day (the time-based approach). Some investigations have suggested that women have a particularly difficult task in estimating time outdoors in adulthood due to their family and occupational roles. We hypothesized that people might gain additional memory cues and estimate lifetime hours spent outdoors more reliably if asked about time spent outdoors according to specific activities (an activity-based approach). Using self-administered, mailed questionnaires, test-retest responses to time-based and to activity-based approaches were evaluated in 124 volunteer radiologic technologist participants from the United States: 64 females and 60 males 48 to 80 years of age. Intraclass correlation coefficients (ICC) were used to evaluate the test-retest reliability of average number of hours spent outdoors in the summer estimated for each approach. We tested the differences between the two ICCs, corresponding to each approach, using a t test with the variance of the difference estimated by the jackknife method. During childhood and adolescence, the two approaches gave similar ICCs for average numbers of hours spent outdoors in the summer. By contrast, compared with the time-based approach, the activity-based approach showed significantly higher ICCs during adult ages (0.69 versus 0.43, P = 0.003) and over the lifetime (0.69 versus 0.52, P = 0.05); the higher ICCs for the activity-based questionnaire were primarily derived from the results for females. Research is needed to further improve the activity-based questionnaire approach for long-term sun exposure assessment. (Cancer Epidemiol Biomarkers Prev 2009;18(2):464–71)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Older adults may find it problematic to attend hospital appointments due to the difficulty associated with travelling to, within and from a hospital facility for the purpose of a face-to-face assessment. This study aims to investigate equivalence between telephone and face-to-face administration for the Frenchay Activities Index (FAI) and the Euroqol-5D (EQ-5D) generic health-related quality of life instrument amongst an older adult population. Methods Patients aged >65 (n = 53) who had been discharged to the community following an acute hospital admission underwent telephone administration of the FAI and EQ-5D instruments seven days prior to attending a hospital outpatient appointment where they completed a face-to-face administration of these instruments. Results Overall, 40 subjects' datasets were complete for both assessments and included in analysis. The FAI items had high levels of agreement between the two modes of administration (item kappa's ranged 0.73 to 1.00) as did the EQ-5D (item kappa's ranged 0.67–0.83). For the FAI, EQ-5D VAS and EQ-5D utility score, intraclass correlation coefficients were 0.94, 0.58 and 0.82 respectively with paired t-tests indicating no significant systematic difference (p = 0.100, p = 0.690 and p = 0.290 respectively). Conclusion Telephone administration of the FAI and EQ-5D instruments provides comparable results to face-to-face administration amongst older adults deemed to have cognitive functioning intact at a basic level, indicating that this is a suitable alternate approach for collection of this information.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To analyze the repeatability of measuring nerve fiber length (NFL) from images of the human corneal subbasal nerve plexus using semiautomated software. Methods: Images were captured from the corneas of 50 subjects with type 2 diabetes mellitus who showed varying severity of neuropathy, using the Heidelberg Retina Tomograph 3 with Rostock Corneal Module. Semiautomated nerve analysis software was independently used by two observers to determine NFL from images of the subbasal nerve plexus. This procedure was undertaken on two occasions, 3 days apart. Results: The intraclass correlation coefficient values were 0.95 (95% confidence intervals: 0.92–0.97) for individual subjects and 0.95 (95% confidence intervals: 0.74–1.00) for observer. Bland-Altman plots of the NFL values indicated a reduced spread of data with lower NFL values. The overall spread of data was less for (a) the observer who was more experienced at analyzing nerve fiber images and (b) the second measurement occasion. Conclusions: Semiautomated measurement of NFL in the subbasal nerve fiber layer is highly repeatable. Repeatability can be enhanced by using more experienced observers. It may be possible to markedly improve repeatability when measuring this anatomic structure using fully automated image analysis software.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Assessments of change in subjective patient reported outcomes such as health-related quality of life (HRQoL) are a key component of many clinical and research evaluations. However, conventional longitudinal evaluation of change may not agree with patient perceived change if patients' understanding of the subjective construct under evaluation changes over time (response shift) or if patients' have inaccurate recollection (recall bias). This study examined whether older adults' perception of change is in agreement with conventional longitudinal evaluation of change in their HRQoL over the duration of their hospital stay. It also investigated this level of agreement after adjusting patient perceived change for recall bias that patients may have experienced. Methods: A prospective longitudinal cohort design nested within a larger randomised controlled trial was implemented. 103 hospitalised older adults participated in this investigation at a tertiary hospital facility. The EQ-5D utility and Visual Analogue Scale (VAS) scores were used to evaluate HRQoL. Participants completed EQ-5D reports as soon as they were medically stable (within three days of admission) then again immediately prior to discharge. Three methods of change score calculation were used (conventional change, patient perceived change and patient perceived change adjusted for recall bias). Agreement was primarily investigated using intraclass correlation coefficients (ICC) and limits of agreement. Results: Overall 101 (98%) participants completed both admission and discharge assessments. The mean (SD) age was 73.3 (11.2). The median (IQR) length of stay was 38 (20-60) days. For agreement between conventional longitudinal change and patient perceived change: ICCs were 0.34 and 0.40 for EQ-5D utility and VAS respectively. For agreement between conventional longitudinal change and patient perceived change adjusted for recall bias: ICCs were 0.98 and 0.90 respectively. Discrepancy between conventional longitudinal change and patient perceived change was considered clinically meaningful for 84 (83.2%) of participants, after adjusting for recall bias this reduced to 8 (7.9%). Conclusions: Agreement between conventional change and patient perceived change was not strong. A large proportion of this disagreement could be attributed to recall bias. To overcome the invalidating effect of response shift (on conventional change) and recall bias (on patient perceived change) a method of adjusting patient perceived change for recall bias has been described.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To identify agreement levels between conventional longitudinal evaluation of change (post–pre) and patient-perceived change (post–then test) in health-related quality of life. Design: A prospective cohort investigation with two assessment points (baseline and six-month follow-up) was implemented. Setting: Community rehabilitation setting. Subjects: Frail older adults accessing community-based rehabilitation services. Intervention: Nil as part of this investigation. Main measures: Conventional longitudinal change in health-related quality of life was considered the difference between standard EQ-5D assessments completed at baseline and follow-up. To evaluate patient-perceived change a ‘then test’ was also completed at the follow-up assessment. This required participants to report (from their current perspective) how they believe their health-related quality of life was at baseline (using the EQ-5D). Patient-perceived change was considered the difference between ‘then test’ and standard follow-up EQ-5D assessments. Results: The mean (SD) age of participants was 78.8 (7.3). Of the 70 participants 62 (89%) of data sets were complete and included in analysis. Agreement between conventional (post–pre) and patient-perceived (post–then test) change was low to moderate (EQ-5D utility intraclass correlation coefficient (ICC)¼0.41, EQ-5D visual analogue scale (VAS) ICC¼0.21). Neither approach inferred greater change than the other (utility P¼0.925, VAS P¼0.506). Mean (95% confidence interval (CI)) conventional change in EQ-5D utility and VAS were 0.140 (0.045,0.236) and 8.8 (3.3,14.3) respectively, while patient-perceived change was 0.147 (0.055,0.238) and 6.4 (1.7,11.1) respectively. Conclusions: Substantial disagreement exists between conventional longitudinal evaluation of change in health-related quality of life and patient-perceived change in health-related quality of life (as measured using a then test) within individuals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe a scaling method for templating digital radiographs using conventional acetate templates independent of template magnification without the need for a calibration marker. The mean magnification factor for the radiology department was determined (119.8%, range117%-123.4%). This fixed magnification factor was used to scale the radiographs by the method described. 32 femoral heads on postoperative THR radiographs were then measured and compared to the actual size. The mean absolute accuracy was within 0.5% of actual head size (range 0 to 3%) with a mean absolute difference of 0.16mm (range 0-1mm, SD 0.26mm). Intraclass Correlation Coefficient (ICC) showed excellent reliability for both inter and intraobserver measurements with ICC scores of 0.993 (95% CI 0.988-0.996) for interobserver measurements and intraobserver measurements ranging between 0.990-0.993 (95% CI 0.980-0.997).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

STUDY DESIGN: Controlled laboratory study. OBJECTIVES: To investigate the reliability and concurrent validity of photographic measurements of hallux valgus angle compared to radiographs as the criterion standard. BACKGROUND: Clinical assessment of hallux valgus involves measuring alignment between the first toe and metatarsal on weight-bearing radiographs or visually grading the severity of deformity with categorical scales. Digital photographs offer a noninvasive method of measuring deformity on an exact scale; however, the validity of this technique has not previously been established. METHODS: Thirty-eight subjects (30 female, 8 male) were examined (76 feet, 54 with hallux valgus). Computer software was used to measure hallux valgus angle from digital records of bilateral weight-bearing dorsoplantar foot radiographs and photographs. One examiner measured 76 feet on 2 occasions 2 weeks apart, and a second examiner measured 40 feet on a single occasion. Reliability was investigated by intraclass correlation coefficients and validity by 95% limits of agreement. The Pearson correlation coefficient was also calculated. RESULTS: Intrarater and interrater reliability were very high (intraclass correlation coefficients greater than 0.96) and 95% limits of agreement between photographic and radiographic measurements were acceptable. Measurements from photographs and radiographs were also highly correlated (Pearson r = 0.96). CONCLUSIONS: Digital photographic measurements of hallux valgus angle are reliable and have acceptable validity compared to weight-bearing radiographs. This method provides a convenient and precise tool in assessment of hallux valgus, while avoiding the cost and radiation exposure associated with radiographs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To test the reliability of Timed Up and Go Tests (TUGTs) in cardiac rehabilitation (CR) and compare TUGTs to the 6-Minute Walk Test (6MWT) for outcome measurement. METHODS: Sixty-one of 154 consecutive community-based CR patients were prospectively recruited. Subjects undertook repeated TUGTs and 6MWTs at the start of CR (start-CR), postdischarge from CR (post-CR), and 6 months postdischarge from CR (6 months post-CR). The main outcome measurements were TUGT time (TUGTT) and 6MWT distance (6MWD). RESULTS: Mean (SD) TUGTT1 and TUGTT2 at the 3 assessments were 6.29 (1.30) and 5.94 (1.20); 5.81 (1.22) and 5.53 (1.09); and 5.39 (1.60) and 5.01 (1.28) seconds, respectively. A reduction in TUGTT occurred between each outcome point (P ≤ .002). Repeated TUGTTs were strongly correlated at each assessment, intraclass correlation (95% CI) = 0.85 (0.76–0.91), 0.84 (0.73–0.91), and 0.90 (0.83–0.94), despite a reduction between TUGTT1 and TUGTT2 of 5%, 5%, and 7%, respectively (P ≤ .006). Relative decreases in TUGTT1 (TUGTT2) occurred from start-CR to post-CR and from start-CR to 6 months post-CR of −7.5% (−6.9%) and −14.2% (−15.5%), respectively, while relative increases in 6MWD1 (6MWD2) occurred, 5.1% (7.2%) and 8.4% (10.2%), respectively (P < .001 in all cases). Pearson correlation coefficients for 6MWD1 to TUGTT1 and TUGTT2 across all times were −0.60 and −0.68 (P < .001) and the intraclass correlations (95% CI) for the speeds derived from averaged 6MWDs and TUGTTs were 0.65 (0.54, 0.73) (P < .001). CONCLUSIONS: Similar relative changes occurred for the TUGT and the 6MWT in CR. A significant correlation between the TUGTT and 6MWD was demonstrated, and we suggest that the TUGT may provide a related or a supplementary measurement of functional capacity in CR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measuring adolescent wellness can assist researchers and practitioners in determining lifestyle behaviors in which adolescents are deficient. An appropriate objective assessment may assist male adolescents who feel uncomfortable revealing behaviors that may indicate wellness deficits. The authors examined the test-retest reliability of the Five Factor Wellness Inventory (5F-Wel) with a sample of male adolescents. Thirty-five participants self-completed the 5F-Wel on two separate occasions, 7 days apart. Limits of agreement, intraclass correlation coefficients, and paired t tests were calculated to investigate agreement and whether systematic differences existed between administrations. The initial findings indicate the 5F-Wel is reliable for use among male adolescents and support its use in research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

STUDY DESIGN: Reliability and case-control injury study. OBJECTIVES: 1) To determine if a novel device, designed to measure eccentric knee flexors strength via the Nordic hamstring exercise (NHE), displays acceptable test-retest reliability; 2) to determine normative values for eccentric knee flexors strength derived from the device in individuals without a history of hamstring strain injury (HSI) and; 3) to determine if the device could detect weakness in elite athletes with a previous history of unilateral HSI. BACKGROUND: HSIs and reinjuries are the most common cause of lost playing time in a number of sports. Eccentric knee flexors weakness is a major modifiable risk factor for future HSIs, however there is a lack of easily accessible equipment to assess this strength quality. METHODS: Thirty recreationally active males without a history of HSI completed NHEs on the device on 2 separate occasions. Intraclass correlation coefficients (ICCs), typical error (TE), typical error as a co-efficient of variation (%TE), and minimum detectable change at a 95% confidence interval (MDC95) were calculated. Normative strength data were determined using the most reliable measurement. An additional 20 elite athletes with a unilateral history of HSI within the previous 12 months performed NHEs on the device to determine if residual eccentric muscle weakness existed in the previously injured limb. RESULTS: The device displayed high to moderate reliability (ICC = 0.83 to 0.90; TE = 21.7 N to 27.5 N; %TE = 5.8 to 8.5; MDC95 = 76.2 to 60.1 N). Mean±SD normative eccentric flexors strength, based on the uninjured group, was 344.7 ± 61.1 N for the left and 361.2 ± 65.1 N for the right side. The previously injured limbs were 15% weaker than the contralateral uninjured limbs (mean difference = 50.3 N; 95% CI = 25.7 to 74.9N; P < .01), 15% weaker than the normative left limb data (mean difference = 50.0 N; 95% CI = 1.4 to 98.5 N; P = .04) and 18% weaker than the normative right limb data (mean difference = 66.5 N; 95% CI = 18.0 to 115.1 N; P < .01). CONCLUSIONS: The experimental device offers a reliable method to determine eccentric knee flexors strength and strength asymmetry and revealed residual weakness in previously injured elite athletes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Expectations held by health professionals and their patients are likely to affect treatment choices in subacute inpatient rehabilitation settings for older adults. There is a scarcity of empirical evidence evaluating whether health professionals expectations of the quality of their patients' future health states are accurate. METHODS A prospective longitudinal cohort investigation was implemented to examine agreement (kappa coefficients, exact agreement, limits-of-agreement, and intraclass-correlation coefficients) between physiotherapists' (n = 23) prediction of patients' discharge health-related quality of life (reported on the EQ-5D-3L) and the actual health-related quality of life self-reported by patients (n = 272) at their discharge assessment (using the EQ-5D-3L). The mini-mental state examination was used as an indicator of patients' cognitive ability. RESULTS Overall, 232 (85%) patients had all assessment data completed and were included in analysis. Kappa coefficients (exact agreement) ranged between 0.37-0.57 (58%-83%) across EQ-5D-3L domains in the lower cognition group and 0.53-0.68 (81%-85%) in the better cognition group. CONCLUSIONS Physiotherapists in this subacute rehabilitation setting predicted their patients' discharge health-related quality of life with substantial accuracy. Physiotherapists are likely able to provide their patients with sound information regarding potential recovery and health-related quality of life on discharge. The prediction accuracy was higher among patients with better cognition than patients with poorer cognition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Used frequently in food contact materials, bisphenol A (BPA) has been studied extensively in recent years, and ubiquitous exposure in the general population has been demonstrated worldwide. Characterising within- and between-individual variability of BPA concentrations is important for characterising exposure in biomonitoring studies, and this has been investigated previously in adults, but not in children. The aim of this study was to characterise the short-term variability of BPA in spot urine samples in young children. Children aged ≥2-<4 years (n = 25) were recruited from an existing cohort in Queensland Australia, and donated four spot urine samples each over a two day period. Samples were analysed for total BPA using isotope dilution online solid phase extraction-liquid chromatography-tandem mass spectrometry, and concentrations ranged from 0.53–74.5 ng/ml, with geometric mean and standard deviation of 2.70 ng/ml and 2.94 ng/ml, respectively. Sex and time of sample collection were not significant predictors of BPA concentration. The between-individual variability was approximately equal to the within-individual variability (ICC = 0.51), and this ICC is somewhat higher than previously reported literature values. This may be the result of physiological or behavioural differences between children and adults or of the relatively short exposure window assessed. Using a bootstrapping methodology, a single sample resulted in correct tertile classification approximately 70% of the time. This study suggests that single spot samples obtained from young children provide a reliable characterization of absolute and relative exposure over the short time window studied, but this may not hold true over longer timeframes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the validity and inter-rater reliability of the Observation System for Recording Activity in Children: Youth Sports (OSRAC:YS). Children (N=29) participating in a parks and recreation soccer program were observed during regularly scheduled practices. Physical activity (PA) intensity and contextual factors were recorded by momentary time-sampling procedures (10-sec observe, 20-sec record). Two observers simultaneously observed and recorded children's PA intensity, practice context, social context, coach behavior, and coach proximity. Inter-rater reliability was based on agreement (Kappa) between the observer's coding for each category, and the Intraclass Correlation Coefficient (ICC) for percent of time spent in MVPA. Validity was assessed by calculating the correlation between OSRAC:YS estimated and objectively measured MVPA. Kappa statistics for each category demonstrated substantial to almost perfect inter-observer agreement (Κappa = 0.67 to 0.93). The ICC for percent time in MVPA was 0.76 (95% C.I. = 0.49 - 0.90). A significant correlation (r = 0.73) was observed for MVPA recorded by observation and MVPA measured via accelerometry. The results indicate the OSRAC:YS is a reliable and valid tool for measuring children's PA and contextual factors during a youth soccer practice.