978 resultados para intra-operative forces


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Adolescent idiopathic scoliosis (AIS) is a deformity of the spine, which may 34 require surgical correction by attaching a rod to the patient’s spine using screws 35 implanted in the vertebral bodies. Surgeons achieve an intra-operative reduction in the 36 deformity by applying compressive forces across the intervertebral disc spaces while 37 they secure the rod to the vertebra. We were interested to understand how the 38 deformity correction is influenced by increasing magnitudes of surgical corrective forces 39 and what tissue level stresses are predicted at the vertebral endplates due to the 40 surgical correction. 41 Methods: Patient-specific finite element models of the osseoligamentous spine and 42 ribcage of eight AIS patients who underwent single rod anterior scoliosis surgery were 43 created using pre-operative computed tomography (CT) scans. The surgically altered 44 spine, including titanium rod and vertebral screws, was simulated. The models were 45 analysed using data for intra-operatively measured compressive forces – three load 46 profiles representing the mean and upper and lower standard deviation of this data 47 were analysed. Data for the clinically observed deformity correction (Cobb angle) were 48 compared with the model-predicted correction and the model results investigated to 49 better understand the influence of increased compressive forces on the biomechanics of 50 the instrumented joints. 51 Results: The predicted corrected Cobb angle for seven of the eight FE models were 52 within the 5° clinical Cobb measurement variability for at least one of the force profiles. 53 The largest portion of overall correction was predicted at or near the apical 54 intervertebral disc for all load profiles. Model predictions for four of the eight patients 55 showed endplate-to-endplate contact was occurring on adjacent endplates of one or 56 more intervertebral disc spaces in the instrumented curve following the surgical loading 57 steps. 58 Conclusion: This study demonstrated there is a direct relationship between intra-59 operative joint compressive forces and the degree of deformity correction achieved. The 60 majority of the deformity correction will occur at or in adjacent spinal levels to the apex 61 of the deformity. This study highlighted the importance of the intervertebral disc space 62 anatomy in governing the coronal plane deformity correction and the limit of this 63 correction will be when bone-to-bone contact of the opposing vertebral endplates 64 occurs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis (AIS) is the most common form of spinal deformity in paediatrics, prevalent in approximately 2-4% of the general population. While it is a complex three-dimensional deformity, it is clinically characterised by an abnormal lateral curvature of the spine. The treatment for severe deformity is surgical correction with the use of structural implants. Anterior single rod correction employs a solid rod connected to the anterior spine via vertebral body screws. Correction is achieved by applying compression between adjacent vertebral body screws, before locking each screw onto the rod. Biomechanical complication rates have been reported as high as 20.8%, and include rod breakage, screw pull-out and loss of correction. Currently, the corrective forces applied to the spine are unknown. These forces are important variables to consider in understanding the biomechanics of scoliosis correction. The purpose of this study was to measure these forces intra-operatively during anterior single rod AIS correction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As many as 20-70% of patients undergoing breast conserving surgery require repeat surgeries due to a close or positive surgical margin diagnosed post-operatively [1]. Currently there are no widely accepted tools for intra-operative margin assessment which is a significant unmet clinical need. Our group has developed a first-generation optical visible spectral imaging platform to image the molecular composition of breast tumor margins and has tested it clinically in 48 patients in a previously published study [2]. The goal of this paper is to report on the performance metrics of the system and compare it to clinical criteria for intra-operative tumor margin assessment. The system was found to have an average signal to noise ratio (SNR) >100 and <15% error in the extraction of optical properties indicating that there is sufficient SNR to leverage the differences in optical properties between negative and close/positive margins. The probe had a sensing depth of 0.5-2.2 mm over the wavelength range of 450-600 nm which is consistent with the pathologic criterion for clear margins of 0-2 mm. There was <1% cross-talk between adjacent channels of the multi-channel probe which shows that multiple sites can be measured simultaneously with negligible cross-talk between adjacent sites. Lastly, the system and measurement procedure were found to be reproducible when evaluated with repeated measures, with a low coefficient of variation (<0.11). The only aspect of the system not optimized for intra-operative use was the imaging time. The manuscript includes a discussion of how the speed of the system can be improved to work within the time constraints of an intra-operative setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research on surgical decision making and risk management usually focuses on peri-operative care, despite the magnitude and frequency of intra-operative risks. The aim of this study was to examine ophthalmic surgeons' intra-operative decisions and risk management strategies in order to explore differences in cognitive processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Hypotension, a common intra-operative incident, bears an important potential for morbidity. It is most often manageable and sometimes preventable, which renders its study important. Therefore, we aimed at examining hospital variations in the occurrence of intra-operative hypotension and its predictors. As secondary endpoints, we determined to what extent hypotension relates to the risk of post-operative incidents and death. METHODS: We used the Anaesthesia Databank Switzerland, built on routinely and prospectively collected data on all anaesthesias in 21 hospitals. The three outcomes were assessed using multi-level logistic regression models. RESULTS: Among 147,573 anaesthesias, hypotension ranged from 0.6% to 5.2% in participating hospitals, and from 0.3% up to 12% in different surgical specialties. Most (73.4%) were minor single events. Age, ASA status, combined general and regional anaesthesia techniques, duration of surgery and hospitalization were significantly associated with hypotension. Although significantly associated, the emergency status of the surgery had a weaker effect. Hospitals' odds ratios for hypotension varied between 0.12 and 2.50 (P < or = 0.001), even after adjusting for patient and anaesthesia factors, and for type of surgery. At least one post-operative incident occurred in 9.7% of the procedures, including 0.03% deaths. Intra-operative hypotension was associated with a higher risk of post-operative incidents and death. CONCLUSION: Wide variations remain in the occurrence of hypotension among hospitals after adjustment for risk factors. Although differential reporting from hospitals may exist, variations in anaesthesia techniques and blood pressure maintenance may also have contributed. Intra-operative hypotension is associated with morbidities and sometimes death, and constant vigilance must thus be advocated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present a new population-based method for the design of bone fixation plates. Standard pre-contoured plates are designed based on the mean shape of a certain population. We propose a computational process to design implants while reducing the amount of required intra-operative shaping, thus reducing the mechanical stresses applied to the plate. A bending and torsion model was used to measure and minimize the necessary intra-operative deformation. The method was applied and validated on a population of 200 femurs that was further augmented with a statistical shape model. The obtained results showed substantial reduction in the bending and torsion needed to shape the new design into any bone in the population when compared to the standard mean-based plates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surgical stress response markedly increases sympathetic nerve activity and catecholamine concentrations. This may contribute to peripheral vasoconstriction, reduced wound perfusion and subsequent tissue hypoxia. Opioids are known to depress the hypothalamic-adrenal response to surgery in a dose-dependent manner. We tested the hypothesis that continuous remifentanil administration produces improved subcutaneous tissue oxygen tension compared to fentanyl bolus administration. Forty-six patients undergoing major abdominal surgery were randomly assigned to receive either fentanyl bolus administration or continuous remifentanil infusion. Mean subcutaneous tissue oxygen values over the entire intra-operative period were significantly higher in the remifentanil group, when compared to the fentanyl group: 8 (2) kPa vs 6.7 (1.5) kPa, % CI difference: - 2.3 kPa to - 0.3 kPa, p = 0.013. Continuous intra-operative opioid administration may blunt vasoconstriction caused by surgical stress and adrenergic responses more than an equi-effective anaesthetic regimen based on smaller-dose bolus opioid administration.