991 resultados para interventional radiology
Resumo:
The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.
Resumo:
PURPOSE: To quantify the prevalence of accidental blood exposure (ABE) among interventional radiologists and contrast that with the prevalence of patients with hepatitis C virus (HCV) undergoing interventional radiology procedures. MATERIALS AND METHODS: A multicenter epidemiologic study was conducted in radiology wards in France. The risk of ABE to radiologists was assessed based on personal interviews that determined the frequency and type of ABE and the use of standard protective barriers. Patients who underwent invasive procedures underwent prospective sampling for HCV serologic analysis. HCV viremia was measured in patients who tested positive for HCV. RESULTS: Of the 77 radiologists who participated in 11 interventional radiology wards, 44% reported at least one incident of mucous membrane blood exposure and 52% reported at least one percutaneous injury since the beginning of their occupational activity. Compliance with standard precautions was poor, especially for the use of protective clothes and safety material. Overall, 91 of 944 treated patients (9.7%) tested positive for HCV during the study period, of whom 90.1% had positive viremia results, demonstrating a high potential for contamination through blood contacts. CONCLUSIONS: The probability of HCV transmission from contact with contaminated blood after percutaneous injury ranged from 0.013 to 0.030; the high frequency of accidental blood exposure and high percentage of patients with HCV could generate a risk of exposure to HCV for radiologists who perform invasive procedures with frequent blood contact. The need to reinforce compliance with standard hygiene precautions is becoming crucial for medical and technical personnel working in these wards.
Resumo:
Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.
Resumo:
Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).
Resumo:
Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoringof the eye lens should be performed on routine basis.
Resumo:
Percutaneous ablative procedures allow curative treatment of stage BCLC 0 or BCLC A hepatocellular carcinoma, as well as liver metastases of colorectal cancer. Several methods exist including radiofrequency ablation, the most commonly used. These techniques can be used in combination with surgical excision or alone if surgery is contraindicated. They are associated with significantly reduced mortality as compared to surgery.
Resumo:
The effective dose delivered to the patient was determined, by modeling, for 257 types of examinations covering the different modalities of diagnostic and interventional radiology. The basic operational dosimetric quantities considered were obtained from the parameters of the examinations on the basis of dosimetric models. These models required a precise characterization of each examination. The operational dosimetric quantities were converted into doses to organs and effective doses using appropriate conversion factors. The determination of the collective effective dose to the Swiss population requires a number of corrections to account for the variability of several parameters: sensitivity of the detection system, age, gender, and build of the patient. The use of various dosimetric models is illustrated in this paper for a limited number of examination types covering the different radiological modalities, for which the established typical effective doses are given. With regard to individual doses, the study indicated that the average effective doses per type of examination can be classified into three levels: (a) the weakly irradiating examinations (less than 0.1 mSv), which represent 78% of the examinations and 4% of the collective dose, (b) the moderately irradiating examinations (between 0.1 mSv and 10 mSv), which represent 21% of the examinations and 72% of the collective dose, (c) the strongly irradiating examinations (more than 10 mSv), which represent 1% of the examinations and 24% of the collective dose.
Resumo:
The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10-12% increase in the number of IR examinations every year (UNSCEAR, 2010). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed.The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.
Resumo:
A nation-wide survey on radiation doses in diagnostic and interventional radiology was conducted in Switzerland in 1998 aiming at establishing their collective radiological impact on the Swiss population. The study consisted on the one hand of surveying the frequency of more than 250 types of examinations, covering conventional radiology, mammography, fluoroscopy, angiography, interventional radiology, CT, bone densitometry, conventional tomography and dental radiology. On the other hand, for each type of examination the associated patient dose was established by modeling. The results of this study show that about 9.5 million diagnostic and interventional examinations are performed annually in Switzerland (1.34 per caput) and that the associated annual collective dose is of the order of 7100 person.Sv (1.0 mSv per caput). Switzerland is similar to other European countries in terms of the frequency of examinations and the collective dose.
Resumo:
Intraarterial procedures such as chemoembolization and radioembolization aim for the palliative treatment of advanced hepatocellular carcinoma (stage BCLC B and C with tumoral portal thrombosis). The combination of hepatic intraarterial chemotherapy and systemic chemotherapy can increase the probability of curing colorectal cancer with hepatic metastases not immediately accessible to surgical treatment or percutaneous ablation.
Resumo:
The aim of this study was to investigate the radiation exposure of the Swiss population to interventional procedures. A nationwide survey was conducted in Switzerland. The annual effective dose per capita due to interventional procedures was found to be 0.14 mSv, corresponding to 12% of the total dose. Coronary angiography and percutaneous coronary interventions were found to be the most frequent and the most irradiating interventional procedures, accounting for 52% of the total examination frequency and 64% of the dose delivered to the population. Switzerland stands at the same level as other countries in terms of effective dose per capita due to interventional radiology.
Resumo:
Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces.