843 resultados para internal tapered connection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Os fluxos gerados pela economia de Cabo Verde, desde sempre, foram insuficientes para financiar o seu desenvolvimento, devido aos constrangimentos relativas à falta de recursos naturais, ao défice da balança comercial e à dimensão e fragmentação do território. Neste sentido, o capital estrangeiro surge como um recurso estratégico no desenvolvimento de CV, sendo um instrumento chave para colmatar alguns défices da economia cabo-verdiana. Logo a relevância do estudo proposto, que parte da questão: “Os incentivos e o ambiente oferecidos por CV têm sido suficientemente eficientes para atrair o IDE ou os números poderiam estar melhores?” Na sequência da revisão teórica e da literatura, a fim de obter a resposta à pergunta da pesquisa, analisamos os incentivos e o ambiente oferecidos aos investidores externos, através de instrumentos empreendidos pelo Governo de CV e analisamos a evolução dos fluxos do IDE no país, com especial atenção ao período 2000-2006, a partir de dados estatísticos. A análise posterior – percepção dos investidores externos em CV – deu lugar a um estudo qualitativo, a partir de um inquérito efectuado à uma amostragem probabilística de dez investidores externos, elegidos a partir de critérios fundamentados. Como resultado, observamos que os instrumentos empreendidos pelo Governo na atracção do IDE têm mais de dez anos de existência, não coincidindo com os maiores picos de IDE em CV ocorridos nos dois últimos anos. Observamos, ainda, que, de uma forma geral, os investidores externos privilegiam o mercado cabo-verdiano pela estabilidade política e económica. Por outro lado, apontam grandes constrangimentos a nível de infra-estrutura, ligações marítimas internas e aéreo para o exterior. As formalidades administrativas foram, também, objecto de avaliação negativa por parte dos investidores inquiridos. Posto isto, concluímos que, de uma forma geral, os instrumentos de atracção ao IDE em CV não são suficientemente eficazes para atender às necessidades dos investidores externos. Isto demonstra que há um interessante terreno a ser explorado. The cash flows generated Cape Verde’s economy, so far, have been insufficient to finance its development, due to constraints concerning the lack of natural resources, the trade balance deficit and the geographical distribution and dimension of the territory. In this context, foreign capital appears as a strategic resource for Cape Verde’s development. Foreign investment is a significant instrument to overcome some shortfalls of the cape-verdean economy. Therefore the relevance of this study which is based on the question: "The incentives offered by CV and the environment have been effective enough to attract FDI or the numbers could be better?" Following the literature and theoretical review, in order to get the answer to the research question, we have analyzed the stimulus and environment provided to foreign investors through instruments launched by the Government. We have analysed the evolution of FDI´s flows into the country, with particular focus on the period 2000 - 2006, from statistical data. The subsequent analysis - the perception of foreign investors in CV - produced a qualitative survey study, conduced on a sampling of ten foreign investors, selected from founded criterions. As a result, we observed that the instruments undertaken by the Government in attracting FDI are over than ten years old and the higher FDI peak took place during the two last years. It was noticed that foreign investors choose the cape-verdean market because of its politic and economic stability. On the other hand, foreign investors show great constraints in terms of infrastructure, internal maritime connection and international flight connections. The administrative formalities are also subject of a negative evaluation by the investors surveyed. We have eventually figured out that the attraction instruments for FDI in CV are not effective enough for the needs of foreign investors. This demonstrates that there is a interesting ground to be explored.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments. Int J Prosthodont 2009;22:283-286.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This systematic review aimed to evaluate if the internal connection is more efficient than the external connection and its associated influencing factors. A specific question was formulated according to the Population, Intervention, Control, and Outcome (PICO): Is internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? An electronic search of the MEDLINE and the Web of Knowledge databases was performed for relevant studies published in English up to November 2013 by two independent reviewers. The keywords used in the search included a combination of dental implant and internal connection or Morse connection or external connection. Selected studies were randomized clinical trials, prospective or retrospective studies, and in vitro studies with a clear aim of investigating the internal and/or external implant connection use. From an initial screening yield of 674 articles, 64 potentially relevant articles were selected after an evaluation of their titles and abstracts. Full texts of these articles were obtained with 29 articles fulfilling the inclusion criteria. Morse taper connection has the best sealing ability. Concerning crestal bone loss, internal connections presented better results than external connections. The limitation of the present study was the absence of randomized clinical trials that investigated if the internal connection was more efficient than the external connection. The external and internal connections have different mechanical, biological, and esthetical characteristics. Besides all systems that show proper success rates and effectiveness, crestal bone level maintenance is more important around internal connections than external connections. The Morse taper connection seems to be more efficient concerning biological aspects, allowing lower bacterial leakage and bone loss in single implants, including aesthetic regions. Additionally, this connection type can be successfully indicated for fixed partial prostheses and overdenture planning, since it exhibits high mechanical stability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary olfactory neurons project their axons to the olfactory bulb, where they terminate in discrete loci called glomeruli. All neurons expressing the same odorant receptor appear to terminate in a few glomeruli in each olfactory bulb. In the P2-IRES-tau-LacZ line of transgenic mice, LacZ is expressed in the perikarya and axons of primary olfactory neurons that express the P2 odorant receptor. In the present study, we examined the developmental appearance of P2 neurons, the topographical targeting of P2 axons, as well as the formation of P2 glomeruli in the olfactory bulb. P2 axons were first detected in the olfactory nerve fiber layer at embryonic day 14.5 (E14.5), and by E15.5 these axons terminated in a broad locus in the presumptive glomerular layer. During the next 5 embryonic days, the elongated cluster of axons developed into discrete glomerulus-like structures. In many cases, glomeruli appeared as pairs, which were initially connected by a fascicle of P2 axons. This connection was lost by postnatal day 7.5, and double glomeruli at the same locus were observed in 85% of adult animals. During the early postnatal period, there was considerable mistargeting of P2 axons. In some cases P2 axons entered inappropriate glomeruli or continued to grow past the glomerular layer into the deeper layers of the olfactory bulb. These aberrant axons were not observed in adult animals. These results indicate that olfactory axons exhibit errors while converging onto a specific glomerulus and suggest that guidance cues may be diffusely distributed at target sites in the olfactory bulb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bowel diseases reveal the complex interplay of sensing and signalling pathways in maintaining healthy homeostasis of the intestine. Recent studies of the xenobiotic nuclear receptor, pregnane X receptor and the inflammatory mediator nuclear transcription factor kappaB (NF-kappaB) reveal a functional link between xenobiotic neutralization and inflammation and explain how certain xenobiotics can affect the immune response. Furthermore, another nuclear receptor, peroxisome proliferator-activated receptor gamma (PPAR gamma) has been shown to produce beneficial effects in experimental inflammatory bowel diseases by repression of NF-kappaB thereby reducing inflammation, whilst its close relative PPAR beta/delta appears at a central position in signalling pathways involved in the progression of colon cancer. Recently accumulated knowledge on the action of these nuclear receptors and NF-kappaB in intestinal homeostasis may provide the rationale for the development of innovative treatment strategies with selective receptor modulators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis focuses on collaborative activities with regard to environmental issues both within the firm and outside the firm with the key suppliers and customers, i.e. internal and external environmental collaboration. Integrating environmental thinking into supply chain management has received increasing interest in recent years. The relational view and the natural resource-based-view together suggest that environmental capabilities can be built jointly with supply chain partners and used to gain sustained competitive advantage. Several studies have been undertaken to analyse the connection between environmental activities and firm performance but most studies have taken only economic performance into account. This study pays attention also to two other dimensions of firm performance, intra-firm supply chain performance and environmental performance, and aims at presenting the linkages between them and environmental collaboration. This thesis creates a research framework for the connections between environmental collaboration and firm performance and suggests approaches to analyse these. In order to find out the key concepts and their relationship, an extensive literature review is conducted. The research framework proposes a positive connection between internal and external environmental collaboration and all three dimensions of firm performance. In addition, environmental performance and intra-firm supply chain performance are expected to contribute positively to economic performance. Hence, firms are suggested to benefit from environmental collaboration both within the firm and outside the firm. Empirical testing of the developed research framework is out of the scope of this study. However, this thesis proposes using a mixed methods research approach, including survey research and multiple case studies. Finland State of Logistics 2012 survey commissioned by the Finnish Ministry of Transport and Communications and conducted by Turku School of Economics is used as an example of data for the quantitative phase. The applicability of these two methods is discussed at a general level and with regard to analysing the research framework developed in the thesis. Future research will aim at the development of the research framework and the methods in order to confirm the connection between environmental collaboration and firm performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

novel design of at internal PIFA integrated with an RF-shielding metal case for application in a clamshell or fielder-tvpe mobile phone is presented. The integrated PIFA has a bent and tapered radiating arm in order to easily fit in the casing of the clamshell mobile phone as an internal antenna. The integrated PlEA can also provide a wide operating bandwidth fir UM7S (1920-2170 MHz) operation. In addition, for the clamshell mobile phone in either the talk or standby condition, only a small effect on the operating bandwidth of the integrated PIFA is obtained. The experimental results of the proposed design are presented