906 resultados para internal jugular vein


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The author studied the structure of the tissue components of the tunicae of the terminal segment of the sigmoid sinus, particularly at the level of the transition between the sigmoid sinus, the superior bulb of the jugular vein and the first portion of the human internal jugular vein; it was established that the transition between the sigmoid sinus and the first portion of the internal jugular vein occupies the whole extension of the superior bulb of the jugular vein up to the inferior third of the first portion of this vessel. These vascular walls exhibit a structure similar to that of the dura, i.e. the tunica adventitia is formed by fascicles of collagenic fibers which describe discontinuous spirals, more open proximal to the beginning of the first portion of the internal jugular vein. Approximately in the inferior third of the first portion of the internal jugular vein, there appear fascicles of smooth muscle fibers which are arranged similarly to those of the venous walls. The tunica intima of these vascular segments exhibits an endothelium resting on a network of elastic fibers which may play the role of an internal elastic lamina. From the bony border of the jugular foramen there originates a connective system whose fascicles of collagenic and elastic fibers incorporate to the wall of the internal jugular vein after describing a stretch in spiral around the vascular lumen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES/HYPOTHESIS Study of the clinical evolution of a primary ear, nose, and throat infection complicated by septic thrombophlebitis of the internal jugular vein. STUDY DESIGN Retrospective case-control study. PATIENTS AND METHODS From 1998 to 2010, 23 patients at our institution were diagnosed with a septic thrombosis of the internal jugular vein. Diagnostics included microbiologic analysis and imaging such as computed tomography, magnetic resonance imaging, and ultrasound. Therapy included broad-spectrum antibiotics, surgery of the primary infectious lesion, and postoperative anticoagulation. The patients were retrospectively analyzed. RESULTS The primary infection sites were found in the middle ear (11), oropharynx (8), sinus (3), and oral cavity (1). Fourteen patients needed intensive care unit treatment for a mean duration of 6 days. Seven patients were intubated, and two developed severe acute respiratory distress syndrome. An oropharynx primary infection site was most prone to a prolonged clinical evolution. Anticoagulation therapy was given in 90% of patients. All 23 patients survived the disseminated infection without consecutive systemic morbidity. CONCLUSION In the pre-antibiotic time, septic internal jugular vein thrombophlebitis was a highly fatal condition with a mortality rate of 90%. Modern imaging techniques allow early and often incidental diagnosis of this clinically hidden complication. Anticoagulation, intensive antibiotic therapy assisted by surgery of the primary infection site, and intensive supportive care can reach remission rates of 100%. LEVEL OF EVIDENCE 3b. Laryngoscope, 2014.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Endocarditis is a type of infection that is common in internal medicine wards and in haemodialysis clinics. The location that is most affected are the heart valves. Herein, we report a case of an uncommon abscess, a sub-endothelial abscess between the transition of the superior vena cava and the right atrium. There were several emboli to the lung and foot, and the agent was related to Staphylococcus aureus and a double-lumen catheter. Usually, this type of abscess is located in valves, either the tricuspid valve if related to catheters or injection drug use or the mitral valve if related to other causes. An exhaustive review was made, but we found no information about the location of this abscess and the rarity of the event motivating the report of infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present investigation was to examine the effects of unilateral and bilateral jugular vein occlusion by temporary surgical ligature on the heart rate and arterial and venous blood pressure in sedentary horses during progressive treadmill exercise. Six horses performed three exercise tests (ET). ET1, considered the control, was performed in horses without jugular occlusions. ET2 and ET3 were performed with unilateral and bilateral occlusion by temporary surgical ligature of the jugular veins, respectively. Heart rate, arterial pressure, and pressure of the occluded jugular vein were evaluated. Clinically, the horses presented apathy, head edema, congested mucous membranes, increased capillary refill time, and dysphagia. These signs were observed with the unilateral jugular vein occlusion and became more evident with the bilateral occlusion. Comparing ETs, no differences were observed in heart rate. However, jugular occlusions promoted a decrease in the mean arterial pressure and a severe increase in jugular pressure. Head edema caused by the jugular vein occlusion in the horses could interfere with the autonomic cardiovascular regulation of arterial blood pressure during exercise, likely leading to an impairment of tissue perfusion. Jugular occlusion, even unilateral, also causes severe head venous congestion, leading to venous hypertension that was aggravated by exercise, which could risk development of cerebral edema and neurological damage. The present results obtained from sedentary horses are preliminary data that lead us to suggest that sport horses presenting jugular occlusive thrombophlebitis, even unilateral, may be prevented from performing athletic activities. © 2013 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An equine, American Troter, female, 5 years of age, was referred to the Diagnostic Imaging Sector at the Veterinary Hospital of the FMVZ, Unesp, Botucatu Campus, with suspected jugular thrombosis. Ultrasonographic findings were heterogeneous tissue at the lumen of the right jugular vein with blockage of its diameter and collateral blood flow formation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Avaliar, por estudo prospectivo, a incidência de complicações relacionadas ao implante e uso de cateteres de longa permanência totalmente implantáveis (CLP) em crianças com câncer, comparando o implante por punção em veia subclávia (SCL) com o implante por punção em veia jugular interna (J). Método: estudo prospectivo com randomização da escolha da punção em veia subclávia ou veia jugular interna para o implante do cateter. Foram considerados como desfechos as complicações que levaram a retirada ou revisão do cateter. Resultados: 83 implantes foram randomizados no período de janeiro de 2004 a abril de 2006 e acompanhados até março de 2008. Dos 83 implantes selecionados 6 foram excluídos, permanecendo 43 pacientes no grupo SCL e 34 no grupo J. Não houve diferença estatística entre os dois grupos em relação à: distribuição por idade, sexo, número de leucócitos no implante, número de plaquetas, tipo de internação para cirurgia (ambulatorial ou não), se houve quimioterapia prévia ao implante e quanto ao tipo de cateter. Na avaliação das complicações se observou, incidência de infecção de 20% no grupo SCL e 11% no grupo J (p: 0,44), incidência de embolia de 23% no grupo SCL e 8% no grupo J (p: 0,11), e incidência de complicações total de 51% no grupo SCL e 23% no grupo J (p 0,02). A média do tempo de permanência do cateter foi de 12,6 meses para o grupo SCL e 14,8 para o grupo J (p: 0,38). A análise por regressão logística mostrou que o peso (p: 0,001) é um fator de risco envolvido com a infecção; e o peso (p: 0,020) e a marca do cateter (p: 0,03) são fatores de risco para embolia. Conclusões: há maior incidência de complicações tardias no grupo SCL. Os pacientes com menor peso tiveram risco maior de desenvolver infecção. Pacientes com menor peso e a marca do cateter são fatores de risco para a ocorrência de embolia do cateter

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.