929 resultados para intermaxillary fixation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: the effective long-term treatments for morbid obesity is bariatric surgery. However, the associated surgical and anesthetic risks led the authors to evaluate intermaxillary fixation, a less aggressive procedure, as a preoperative treatment in selected patients with morid obesity.Methods: 22 patients (5 male, 17 female, ages 16-53 years, with BMI 44.9 +/- 5.4 kg/m(2)) underwent intermaxillary fixation. The procedure consisted of fitting brackets on the front face of the teeth and posterior application of elastic bands to impede mouth opening.Results: At the end of 6 weeks, weight loss was 7.4 +/- 2.6% there was general improvement in lipid profile, glycemia, and blood pressure. There was no recorded discomfort, pain, or any other difficulty during this treatment.Conclusion: Intermaxillary fixation can be used as a pre-surgical solution for weight reduction in preparation for bariatric surgery, improving co-morbid aspects such as blood pressure, glycemia, and lipid profile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study was conducted to comparatively evaluate, in a prospective and randomized manner, 2 techniques for providing double-gloving protection during arch bar placement for intermaxillary fixation. Materials and Methods: A total of 42 consecutive patients in whom application of an Erich bar was indicated for intermaxillary fixation were equally divided into 2 groups. In group 1, 2 sterile surgical gloves were used; in group 2, a nonsterile disposable inner glove was used under a sterile surgical glove. Wilcoxon, Mann-Whitney, Kruskal-Wallis, and binomial statistical tests were used to analyze the findings. Results: A total of 103 perforations were found in the outer gloves (47 in group 1 and 56 in group 2), along with 5 perforations in inner gloves in both groups (α = .01). No significant statistical difference was found between groups in terms of inner glove perforations (α = .05). The nondominant hand presented with 70.9% of the perforations, statistically significant to 1%. Conclusions: Both double-gloving techniques were found to provide effective clinician protection. The use of a nonsterile disposable glove under the surgical glove is possible for less-invasive procedures, offering the same safety as using 2 sterile surgical gloves while decreasing operational costs. This method does not eliminate the need to change gloves when a perforation is suspected or noted during the surgery, however. © 2007 American Association of Oral and Maxillofacial Surgeons.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures. STUDY DESIGN: We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any. RESULTS: All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications. CONCLUSION: This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Our goal was to study the use of 2.0-mm miniplates for the fixation of mandibular fractures. Records of 191 patients who experienced a total of 280 mandibular fractures that were treated with 2.0-mm miniplates were reviewed. One hundred twelve of those patients, presenting 160 fractures, who attended a late follow-up were also clinically evaluated. Miniplates were used in the same positions described by AO/ASIF. No intermaxillary fixation was used. All patients included had a minimum follow-up of 6 months. Demographic data, procedures, postoperative results, and complications were analyzed. Mandibular fractures occurred mainly in males (mean age, 30.3 years). Mean follow-up was 21.92 months. The main etiology was motor vehicle accident. The most common fracture was the angle fracture (28.21%). Twenty-two fractures developed infection, for an overall incidence of 7.85%. When only angle fractures are considered, that incidence is increased to 18.98%. Although only 1 patient (0.89%) described inferior alveolar nerve paresthesia, objective testing revealed sensitivity alterations in 31.52% of the patients who had fractures in regions related to the inferior alveolar nerve. Temporary mild deficit of the marginal mandibular branch was observed in 2.56% of the extraoral approaches performed and 2.48% presented with hypertrophic scars. Incidence of occlusal alterations was 4.0%. Facial asymmetry was observed in 2.67% of the patients, whereas malunion incidence was 1.78%. Fibrous union, mostly partial, occurred in 2.38% of the fractures, but only 1 of those presented with mobility (0.59%). Condylar resorption developed in 6.25% of the fixated condylar fractures. Mean mouth opening was 42.08 mm. The overall incidence of complications, including infections, was similar to those described for more rigid methods of fixation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated. Methods: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS-6-DFS)/2, which represents deviation of the mini-implant`s final position regarding the central point initially selected. Then SW, ID, and screw diameter (SO) were combined to estimate the surgical risk with RI expressed by RI = SO/SW-ID. Results: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW. Conclusions: The G-RSG accuracy allowed fine prediction of the final DFS position in the inter-radicular septum, with a low RI, which is a helpful tool to estimate surgical risks. (Am J Orthod Dentofacial Orthop 2009; 136: 722-35)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. This study evaluated the reliability of tooth-crown radiographic references to aid in orthodontic mini-implant insertion and showed an insertion technique based on these references. Study design. The sample consisted of 213 interradicular septa evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width and its midpoint was linked to the interdental contact point to determine septum midline (SML). The distances from SML to mesial and distal teeth were measured and compared to evaluate SML centralization degree in 2 different septum heights. Results. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. Conclusions. The tooth-crown radiographic references determine a high centralization degree of the SML on which an insertion site could be defined. The greater SML centralization degree was observed at the coronal septum area. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e8-e16)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Fractures of the mandible (lower jaw) are a common occurrence and usually related to interpersonal violence or road traffic accidents. Mandibular fractures may be treated using open (surgical) and closed (non-surgical) techniques. Fracture sites are immobilized with intermaxillary fixation (IMF) or other external or internal devices (i.e. plates and screws) to allow bone healing. Various techniques have been used, however uncertainty exists with respect to the specific indications for each approach. OBJECTIVES The objective of this review is to provide reliable evidence of the effects of any interventions either open (surgical) or closed (non-surgical) that can be used in the management of mandibular fractures, excluding the condyles, in adult patients. SEARCH METHODS We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 28 February 2013), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 1), MEDLINE via OVID (1950 to 28 February 2013), EMBASE via OVID (1980 to 28 February 2013), metaRegister of Controlled Trials (to 7 April 2013), ClinicalTrials.gov (to 7 April 2013) and the WHO International Clinical Trials Registry Platform (to 7 April 2013). The reference lists of all trials identified were checked for further studies. There were no restrictions regarding language or date of publication. SELECTION CRITERIA Randomised controlled trials evaluating the management of mandibular fractures without condylar involvement. Any studies that compared different treatment approaches were included. DATA COLLECTION AND ANALYSIS At least two review authors independently assessed trial quality and extracted data. Results were to be expressed as random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated to include both clinical and methodological factors. MAIN RESULTS Twelve studies, assessed as high (six) and unclear (six) risk of bias, comprising 689 participants (830 fractures), were included. Interventions examined different plate materials and morphology; use of one or two lag screws; microplate versus miniplate; early and delayed mobilization; eyelet wires versus Rapid IMF™ and the management of angle fractures with intraoral access alone or combined with a transbuccal approach. Patient-oriented outcomes were largely ignored and post-operative pain scores were inadequately reported. Unfortunately, only one or two trials with small sample sizes were conducted for each comparison and outcome. Our results and conclusions should therefore be interpreted with caution. We were able to pool the results for two comparisons assessing one outcome. Pooled data from two studies comparing two miniplates versus one miniplate revealed no significant difference in the risk of post-operative infection of surgical site (risk ratio (RR) 1.32, 95% CI 0.41 to 4.22, P = 0.64, I(2) = 0%). Similarly, no difference in post-operative infection between the use of two 3-dimensional (3D) and standard (2D) miniplates was determined (RR 1.26, 95% CI 0.19 to 8.13, P = 0.81, I(2) = 27%). The included studies involved a small number of participants with a low number of events. AUTHORS' CONCLUSIONS This review illustrates that there is currently inadequate evidence to support the effectiveness of a single approach in the management of mandibular fractures without condylar involvement. The lack of high quality evidence may be explained by clinical diversity, variability in assessment tools used and difficulty in grading outcomes with existing measurement tools. Until high level evidence is available, treatment decisions should continue to be based on the clinician's prior experience and the individual circumstances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this investigation was to compare the skeletal stability of three different rigid fixation methods after mandibular advancement. Fifty-five class II malocclusion patients treated with the use of bilateral sagittal split ramus osteotomy and mandibular advancement were selected for this retrospective study. Group 1 (n = 17) had miniplates with monocortical screws, Group 2 (n = 16) had bicortical screws and Group 3 (n = 22) had the osteotomy fixed by means of the hybrid technique. Cephalograms were taken preoperatively, 1 week within the postoperative care period, and 6 months after the orthognathic surgery. Linear and angular changes of the cephalometric landmarks of the chin region were measured at each period, and the changes at each cephalometric landmark were determined for the time gaps. Postoperative changes in the mandibular shape were analyzed to determine the stability of fixation methods. There was minimum difference in the relapse of the mandibular advancement among the three groups. Statistical analysis showed no significant difference in postoperative stability. However, a positive correlation between the amount of advancement and the amount of postoperative relapse was demonstrated by the linear multiple regression test (p < 0.05). It can be concluded that all techniques can be used to obtain stable postoperative results in mandibular advancement after 6 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with other fixation methods in mandibular symphysis fractures. Ten polyurethane mandibles were allocated to each group and fixed as follows: group PRP, 2 perpendicular miniplates; group PLL, 1 miniplate and 1 plate, parallel; and group CS, 2 cannulated screws. Vertical linear loading tests were performed. The differences between mean values were analyzed with the Tukey test. The photoelastic test was carried out using a polariscope. The results revealed differences between the CS and PRP groups at 1, 3, 5, and 10 millimeters of displacement. The photoelastic test confirmed higher stress concentration in all groups close to the mandibular base, whereas the CS group showed it throughout the region assessed. Conical cannulated screws performed well in mechanical and photoelastic tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to compare four methods of fixation in mandibular body fractures. Mechanical and photoelastic tests were performed using polyurethane and photoelastic resin mandibles, respectively. The study groups contained the following: (I), two miniplates of 2.0 mm; (II) one 2.0 mm plate and an Erich arch bar; (III) one 2.4 mm plate and an Erich arch bar, and (IV) one 2.0 mm plate and one 2.4 mm plate. The differences between the mean values were analyzed using Tukey's test, the Mann-Whitney test and the Bonferroni correction. Group II recorded the lowest resistance, followed by groups I, IV and III. The photoelastic test confirmed the increase of tension in group II. The 2.4 mm system board in linear mandibular body fractures provided more resistance and the use of only one 2.0 mm plate in the central area of the mandible created higher tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the mandibular displacement from three methods of centric relation record using an anterior jig associated with (A) chin point guidance, (B) swallowing (control group) and (C) bimanual manipulation. Ten patients aged 25-39 years were selected if they met the following inclusion criteria: complete dentition (up to the second molars), Angle class I and absence of signs and symptoms of temporomandibular disorders and diagnostic casts showing stability in the maximum intercuspation (MI) position. Impressions of maxillary and mandibular arches were made with an irreversible hydrocolloid impression material. Master casts of each patient were obtained, mounted on a microscope table in MI as a reference position and 5 records of each method were made per patient. The mandibular casts were then repositioned with records interposed and new measurements were obtained. The difference between the two readings allowed measuring the displacement of the mandible in the anteroposterior and lateral axes. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) among the three methods for measuring lateral displacement (A=0.38 ± 0.26, B=0.32 ± 0.25 and C=0.32 ± 0.23). For the anteroposterior displacement (A=2.76 ± 1.43, B=2.46 ± 1.48 and C=2.97 ± 1.51), the swallowing method (B) differed significantly from the others (p<0.05), but no significant difference (p>0.05) was found between chin point guidance (A) and bimanual manipulation (C). In conclusion, the swallowing method produced smaller mandibular posterior displacement than the other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Rotational osteotomy is frequently indicated to correct excessive femoral anteversion in cerebral palsy patients. Angled blade plate is the standard fixation device used when performed in the proximal femur, but extensile exposure is required for plate accommodation. The authors developed a short locked intramedullary nail to be applied percutaneously in the fixation of femoral rotational osteotomies in children with cerebral palsy and evaluated its mechanical properties. Methods: The study was divided into three stages. In the first part, a prototype was designed and made based on radiographic measurements of the femoral medullary canal of ten-year-old patients. In the second, synthetic femoral models based on rapid-prototyping of 3D reconstructed images of patients with cerebral palsy were obtained and were employed to adjust the nail prototype to the morphological changes observed in this disease. In the third, rotational osteotomies were simulated using synthetic femoral models stabilized by the nail and by the AO-ASIF fixed-angle blade plate. Mechanical testing was done comparing both devices in bending-compression and torsion. Results: The authors observed proper adaptation of the nail to normal and morphologically altered femoral models, and during the simulated osteotomies. Stiffness in bending-compression was significantly higher in the group fixed by the plate (388.97 +/- 57.25 N/mm) than in that fixed by the nail (268.26 +/- 38.51 N/mm) as torsional relative stiffness was significantly higher in the group fixed by the plate (1.07 +/- 0.36 Nm/degrees) than by the nail (0.35 +/- 0.13 Nm/degrees). Conclusions: Although the device presented adequate design and dimension to fit into the pediatric femur, mechanical tests indicated that the nail was less stable than the blade plate in bending-compression and torsion. This may be a beneficial property, and it can be attributed to the more flexible fixation found in intramedullary devices.