980 resultados para interdigitated surface electrode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Radio Frequency (RF) based digital data transmission scheme with 8 channel encoder/decoder ICs is proposed for surface electrode switching of a 16-electrode wireless Electrical Impedance Tomography (EIT) system. A RF based wireless digital data transmission module (WDDTM) is developed and the electrode switching of a EIT system is studied by analyzing the boundary data collected and the resistivity images of practical phantoms. An analog multiplexers based electrode switching module (ESM) is developed with analog multiplexers and switched with parallel digital data transmitted by a wireless transmitter/receiver (T-x/R-x) module working with radio frequency technology. Parallel digital bits are generated using NI USB 6251 card working in LabVIEW platform and sent to transmission module to transmit the digital data to the receiver end. The transmitter/receiver module developed is properly interfaced with the personal computer (PC) and practical phantoms through the ESM and USB based DAQ system respectively. It is observed that the digital bits required for multiplexer operation are sequentially generated by the digital output (D/O) ports of the DAQ card. Parallel to serial and serial to parallel conversion of digital data are suitably done by encoder and decoder ICs. Wireless digital data transmission module successfully transmitted and received the parallel data required for switching the current and voltage electrodes wirelessly. 1 mA, 50 kHz sinusoidal constant current is injected at the phantom boundary using common ground current injection protocol and the boundary potentials developed at the voltage electrodes are measured. Resistivity images of the practical phantoms are reconstructed from boundary data using EIDORS. Boundary data and the resistivity images reconstructed from the surface potentials are studied to assess the wireless digital data transmission system. Boundary data profiles of the practical phantom with different configurations show that the multiplexers are operating in the required sequence for common ground current injection protocol. The voltage peaks obtained at the proper positions in the boundary data profiles proved the sequential operation of multiplexers and successful wireless transmission of digital bits. Reconstructed images and their image parameters proved that the boundary data are successfully acquired by the DAQ system which in turn again indicates a sequential and proper operation of multiplexers as well as the successful wireless transmission of digital bits. Hence the developed RF based wireless digital data transmission module (WDDTM) is found suitable for transmitting digital bits required for electrode switching in wireless EIT data acquisition system. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single Sr88+ ions over an ion height range of 200-1000 μm for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model. © 2010 The American Physical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose. Electrical stimulation of the pelvic floor is used as an adjunct in the conservative treatment of urinary incontinence. No consensus exists, however, regarding electrode placements for optimal stimulation of the pelvic-floor musculature. The purpose of this study was to compare two different bipolar electrode placements, one suggested by Laycock and Green (L2) the other by Dumoulin (D2), during electrical stimulation with interferential currents of the pelvic-floor musculature in continent women, using a two-group crossover design. Subjects. Ten continent female volunteers, ranging in age from 20 to 39 years (X̅=27.3, SD=5.6), were randomly assigned to one of two study groups. Methods. Each study group received neuromuscular electrical stimulation (NMES) of the pelvic-floor musculature using both electrode placements, the order of application being reversed for each group. Force of contraction was measured as pressure (in centimeters of water [cm H2O]) exerted on a vaginal pressure probe attached to a manometer. Data were analyzed using a two-way, mixed-model analysis of variance. Results. No difference in pressure was observed between the two electrode placements. Differences in current amplitude were observed, with the D2 electrode placement requiring less current amplitude to produce a maximum recorded pressure on the manometer. Subjective assessment by the subjects revealed a preference for the D2 electrode placement (7 of 10 subjects). Conclusion and Discussion. The lower current amplitudes required with the D2 placement to obtain recordings comparable to those obtained with the L2 technique suggest a more comfortable stimulation of the pelvic-floor muscles. The lower current amplitudes required also suggest that greater increases in pressure might be obtained with the D2 placement by increasing the current amplitude while remaining within the comfort threshold. These results will help to define treatment guidelines for a planned clinical study investigating the effects of NMES and exercise in the treatment of urinary stress incontinence in women postpartum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Purpose. Electrical stimulation of the pelvic floor is used as an adjunct in the conservative treatment of urinary incontinence. No consensus exists, however, regarding electrode placements for optimal stimulation of the pelvic-floor musculature. The purpose of this study was to compare two different bipolar electrode placements, one suggested by Laycock and Green (L2) the other by Dumoulin (D2), during electrical stimulation with interferential currents of the pelvic-floor musculature in continent women, using a two-group crossover design. Subjects. Ten continent female volunteers, ranging in age from 20 to 39 years (X̅=27.3, SD=5.6), were randomly assigned to one of two study groups. Methods. Each study group received neuromuscular electrical stimulation (NMES) of the pelvic-floor musculature using both electrode placements, the order of application being reversed for each group. Force of contraction was measured as pressure (in centimeters of water [cm H2O]) exerted on a vaginal pressure probe attached to a manometer. Data were analyzed using a two-way, mixed-model analysis of variance. Results. No difference in pressure was observed between the two electrode placements. Differences in current amplitude were observed, with the D2 electrode placement requiring less current amplitude to produce a maximum recorded pressure on the manometer. Subjective assessment by the subjects revealed a preference for the D2 electrode placement (7 of 10 subjects). Conclusion and Discussion. The lower current amplitudes required with the D2 placement to obtain recordings comparable to those obtained with the L2 technique suggest a more comfortable stimulation of the pelvic-floor muscles. The lower current amplitudes required also suggest that greater increases in pressure might be obtained with the D2 placement by increasing the current amplitude while remaining within the comfort threshold. These results will help to define treatment guidelines for a planned clinical study investigating the effects of NMES and exercise in the treatment of urinary stress incontinence in women postpartum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conductive membranes were prepared by magnetic alignment of graphite-coated iron nanoparticles (GCINs) in a polyisobutylene (PIB) matrix, which was cast onto an interdigitated surface electrode. Toluene and tetrahydrofuran (THF) were used as solvents for the casting solution. Different molecular weights of PIB and solutions with concentrations ranging from 0.05- to 50-wt% were explored to optimize the mechanical and physical properties of the membrane. The amount of GCINs used in the membranes ranged from 0.1- to 2.5-wt%, and a sonicator was used to disperse the particles in the membrane. Sedimentation and surfactant studies were conducted to investigate the dispersion of GCINs in solutions. Progresses were made to find an optimal combination of various parameters in order to attain thin homogenous membranes for fast response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recently developed whole of surface electroplating technique was used to obtain mass-transfer rates in the separated flow region of a stepped rotating cylinder electrode. These data are compared with previously reported mass-transfer rates obtained with a patch electrode. It was found that the two methods yield different results, where at lower Reynolds numbers, the mass-transfer rate enhancement was noticeably higher for the whole of the surface electrode than for the patch electrode. The location of the peak mass transfer behind the step, as measured with a patch electrode, was reported to be independent of the Reynolds number in previous studies, whereas the whole of the surface electrode shows a definite Reynolds number dependence. Large eddy simulation results for the recirculating region behind a step are used in this work to show that this difference in behavior is related to the existence of a much thinner fluid layer at the wall for which the velocity is a linear junction of distance from the wall. Consequently, the diffusion layer no longer lies well within a laminar sublayer. It is concluded that the patch electrode responds to the wall shear stress for smooth wall flow as well as for the disturbed flow region behind the step. When the whole of the surface is electro-active, the response is to mass transfer even when this is not a sole function of wall shear stress. The results demonstrate that the choice of the mass-transfer measurement technique in corrosion studies can have a significant effect on the results obtained from empirical data.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Surface electrode switching of 16-electrode wireless EIT is studied using a Radio Frequency (RF) based digital data transmission technique operating with 8 channel encoder/decoder ICs. An electrode switching module is developed the analog multiplexers and switched with 8-bit parallel digital data transferred by transmitter/receiver module developed with radio frequency technology. 8-bit parallel digital data collected from the receiver module are converted to 16-bit digital data by using binary adder circuits and then used for switching the electrodes in opposite current injection protocol. 8-bit parallel digital data are generated using NI USB 6251 DAQ card in LabVIEW software and sent to the transmission module which transmits the digital data bits to the receiver end. Receiver module supplies the parallel digital bits to the binary adder circuits and adder circuit outputs are fed to the multiplexers of the electrode switching module for surface electrode switching. 1 mA, 50 kHz sinusoidal constant current is injected at the phantom boundary using opposite current injection protocol. The boundary potentials developed at the voltage electrodes are measured and studied to assess the wireless data transmission.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Functional Electrical Stimulation (FES) is a technique that consists on applying electrical current pulses to artificially activate motor nerve fibers and produce muscle contractions to achieve functional movements. The main applications of FES are within the rehabilitation field, in which this technique is used to aid recovery or to restore lost motor functions. People that benefit of FES are usually patients with neurological disorders which result in motor dysfunctions; most common patients include stroke and spinal cord injury (SCI). Neuroprosthesis are devices that have their basis in FES technique, and their aim is to bridge interrupted or damaged neural paths between the brain and upper or lower limbs. One of the aims of neuroprosthesis is to artificially generate muscle contractions that produce functional movements, and therefore, assist impaired people by making them able to perform activities of daily living (ADL). FES applies current pulses and stimulates nerve fibers by means of electrodes, which can be either implanted or surface electrodes. Both of them have advantages and disadvantages. Implanted electrodes need open surgery to place them next to the nerve root, so these electrodes carry many disadvantages that are produced by the use of invasive techniques. In return, as the electrodes are attached to the nerve, they make it easier to achieve selective functional movements. On the contrary, surface electrodes are not invasive and are easily attached or detached on the skin. Main disadvantages of surface electrodes are the difficulty of selectively stimulating nerve fibers and uncomfortable feeling perceived by users due to sensory nerves located in the skin. Electrical stimulation surface electrode technology has improved significantly through the years and recently, multi-field electrodes have been suggested. This multi-field or matrix electrode approach brings many advantages to FES; among them it is the possibility of easily applying different stimulation methods and techniques. The main goal of this thesis is therefore, to test two stimulation methods, which are asynchronous and synchronous stimulation, in the upper limb with multi-field electrodes. To this end, a purpose-built wrist torque measuring system and a graphic user interface were developed to measure wrist torque produced with each of the methods and to efficiently carry out the experiments. Then, both methods were tested on 15 healthy subjects and sensitivity results were analyzed for different cases. Results show that there are significant differences between methods regarding sensation in some cases, which can affect effectiveness or success of FES.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conjugated polymers have been subject of great interest in the recent literature from both fundamental point of view and applied science perspective. Among the several types of conjugated polymers used in recent investigations, polythiophene and its derivatives have attracted considerable attention over the past 20 years due to their high mobility and other remarkable solid-state properties. They have potential applications in many fields, such as microelectronic devices, catalysts, organic field-effect transistors, chemical sensors, and biosensors. They have been studied as gas and volatile organic compounds (VOCs) sensors using different principles or transduction techniques, such as optical absorption, conductivity, and capacitance measurements. In this work, we report on the fabrication of gas sensors based on a conducting polymer on an interdigitated gold electrode. We use as active layer of the sensor a polythiophene derivative: poly (3-hexylthiophene) (P3HT) and analyzed its conductivity as response for exposure to dynamic flow of saturated vapors of six VOCs [n-hexane, toluene, chloroform, dichloromethane, methanol, and tetrahydrofuran (THE)]. Different responses were obtained upon exposure to all VOCs, THF gave the higher response while methanol the lower response. The influence of moisture on the measurements was also evaluated. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The superior belly of the omohyoid muscle and the anterior belly of the digastric muscle, were studied electromyographically in 20 young volunteers. For each muscle, 1 pair of monopolar electrodes was employed. One was a surface electrode and the other a needle electrode, which was inserted in the belly of the muscle. The surface electrode was placed 1 cm apart from the needle electrode. The most marked action of both muscles was on the movement of lowering the mandible. They also act in those movements for the performance of which they have associated a component of lowering the jaw, propulsion, laterality to the right and the left and retrusion. They are not active in the resting position and during jaw movements of elevation, extrusion and protrusion. Both muscles are active most of the time, simultaneously, but it is not possible to demonstrate that there is a synchronism between their actions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this paper was to analyse the activity of the longissimus dorsi and the iliocostalis lumborum muscles--components of the erector spinae muscle--in order to determine: their action potentials during the use of a plain and a tilt Roman table; 2) to compare the action potentials of the two muscles; 3) to verify if the action potential of these two muscles remain constant during the arc of movement--knee flexion and extension--divided into angle ranges, and 4) to compare the action potentials of the muscles in movements performed in a free manner and against resistance. Twenty-three young volunteers were studied electromyographically and each muscle received a needle electrode (Mise) and a surface electrode. The results showed that the table model did not determine any difference in the action potential of the muscles and that, on average, the iliocostalis lumborum muscle developed a slightly higher action potential than the longissimus dorsi muscle during the free flexion of knees on the plain table. In more than 70% of the cases, there was no difference between the action potential of the muscles over the various angle ranges of knee flexion and extension. Relatively higher action potentials were recorded during knee flexion and extension against resistance than during the same movements performed in a free manner. This shows that the paravertebral musculature responds better to an overload (8 kg) imposed on the knee flexor group, confirming the stabilizing role of the longissimus dorsi and iliocostalis lumborum muscles during knee flexion and extension on a Roman table.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To determine the minimum alveolar concentration (MAC) of isoflurane in Shetland ponies using a sequence of three different supramaximal noxious stimulations at each tested concentration of isoflurane rather than a single stimulation. STUDY DESIGN: Prospective, experimental trial. ANIMALS: Seven 4-year-old, gelding Shetland ponies. METHODS: The MAC of isoflurane was determined for each pony. Three different modes of electrical stimulation were applied consecutively (2 minute intervals): two using constant voltage (90 V) on the gingiva via needle- (CVneedle) or surface-electrodes (CVsurface) and one using constant current (CC; 40 mA) via surface electrodes applied to the skin over the digital nerve. The ability to clearly interpret the responses as positive, the latency of the evoked responses and the inter-electrode resistance were recorded for each stimulus. RESULTS: Individual isoflurane MAC (%) values ranged from 0.60 to 1.17 with a mean (+/-SD) of 0.97 (+/-0.17). The responses were more clearly interpreted with CC, but did not reach statistical significance. The CVsurface mode produced responses with a longer delay. The CVneedle mode was accompanied by variable inter-electrode resistances resulting in uncontrolled stimulus intensity. At 0.9 MAC, the third stimulation induced more positive responses than the first stimulation, independent of the mode of stimulation used. CONCLUSIONS: The MAC of isoflurane in the Shetland ponies was lower than expected with considerable variability among individuals. Constant current surface electrode stimulations were the most repeatable. A summation over the sequence of three supramaximal stimulations was observed around 0.9 MAC. CLINICAL RELEVANCE: The possibility that Shetland ponies require less isoflurane than horses needs further investigation. Constant current surface-electrode stimulations were the most repeatable. Repetitive supramaximal stimuli may have evoked movements at isoflurane concentrations that provide immobility when single supramaximal stimulation was applied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to compare orthodromic sural nerve conduction study (NCS) results using ultrasound-guided needle positioning (USNP) to surface electrode recordings. METHODS 51 healthy subjects aged 24 - 80 years, divided into 5 age groups, were examined. Electrical stimuli were applied behind the lateral malleolus. Sensory nerve action potentials (SNAPs) were recorded 8 and 15 cm proximally with surface and needle electrodes. RESULTS Mean SNAP amplitudes in µV (surface/needle electrodes) averaged 12.7 (SD 7.6)/40.6 (SD 20.8), P<0.001, for subjects aged 20-29 years, and 5.0 (SD 2.4)/19.8 (SD 9.8), P<0.01, for subjects aged > 60 years. SNAP amplitudes were smaller at the proximal recording location. DISCUSSION NCS using USNP yield higher amplitude responses than surface electrodes in all age groups at all recording sites. SNAP amplitudes are smaller at proximal recording locations due to sural nerve branching. This article is protected by copyright. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This letter presents a novel temperature sensor, which consists of an interdigitated comb electrode structure with a micrometric-scale size, nanometric metallic layer, and nematic liquid crystal (NLC) film. This sensor exploits the permittivity dependence of the NLC with temperature and principle of electrical conductivity above the percolation threshold in thin film metallic layers. The latter has been demonstrated to increase the temperature sensitivity considerably. The high impedance input reduces the power dissipation, and the high enough voltage output makes it easy to measure the output signal with high precision. The operation principle and fabrication process as well as the characterization of the temperature sensor are presented. Experimental results show that the device offers a sensitivity of 9 mV/°C and is dependent on the applied voltage. This is six times greater than the same structure without the use of a nanometric layer.