904 resultados para instrumentation for chemistry laboratories


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal baths to decrease ambient temperature are an indispensable tool for most research and teaching laboratories, especially those in tropical or equatorial regions. A simple and inexpensive thermal bath has been developed based on a scratched compressor. It has three possible setups for cooling: sample immersed into the bath, sample flowing through the bath, and cooling liquid flowing in a jacket around the sample. It has been tested for 40 months. The temperature ranges from room temperature to 0 °C, when using water. The repeatability is better than 3% and the precision varies from 0.5% to 2%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An American National Standard, December 2, 1981.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Multi-pumping flow systems exploit pulsed flows delivered by Solenoid pumps. Their improved performance rely on the enhanced radial mass transport inherent to the pulsed flow, which is a consequence of the establishment of vortices thus a tendency towards turbulent mixing. This paper presents several evidences of turbulent mixing in relation to pulsed flows. such as recorded peak shape, establishment of fluidized beds, exploitation of flow reversal, implementation of relatively slow chemical reactions and/or heating of the reaction medium. In addition, Reynolds number associated with the GO period of a pulsed flow is estimated and photographic images of dispersing samples flowing under laminar regime and pulsed flow conditions are presented. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The integration of optical detection methods in continuous flow microsystems can highly extend their range of application, as long as some negative effects derived from their scaling down can be minimized. Downsizing affects to a greater extent the sensitivity of systems based on absorbance measurements than the sensitivity of those based on emission ones. However, a careful design of the instrumental setup is needed to maintain the analytical features in both cases. In this work, we present the construction and evaluation of a simple miniaturized optical system, which integrates a novel flow cell configuration to carry out chemiluminescence (CL) measurements using a simple photodiode. It consists of a micro-mixer based on a vortex structure, which has been constructed by means of the low-temperature cofired ceramics (LTCC) technology. This mixer not only efficiently promotes the CL reaction due to the generated high turbulence but also allows the detection to be carried out in the same area, avoiding intensity signal losses. As a demonstration, a flow injection system has been designed and optimized for the detection of cobalt(H) in water samples. It shows a linear response between 2 and 20 mu M with a correlation of r > 0.993, a limit of detection of 1.1 mu M, a repeatability of RSD = 12.4 %, and an analysis time of 17 s. These results demonstrate the suitability of the proposal to the determination of compounds involved in CL reactions by means of an easily constructed versatile device based on low-cost instrumentation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A dual-channel electrospray microchip has been developed for electrospray ionization mass spectrometry (ESI-MS) where aqueous samples are mixed at the Taylor cone with an organic buffer. Due to the fast and effective mixing in the Taylor cone, the aqueous sample can be well ionized with a high ion intensity. The influence of geometric parameters such as the distance between the two microchannels at their junction at the tip of the emitter has been investigated together with chemical parameters such as the organic buffer composition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a compact portable biosensor to measure arsenic As(III) concentrations in water using Escherichia coli bioreporter cells. Escherichia coli expresses green fluorescent protein in a linearly dependent manner as a function of the arsenic concentration (between 0 and 100 μg/L). The device accommodates a small polydimethylsiloxane microfluidic chip that holds the agarose-encapsulated bacteria, and a complete optical illumination/collection/detection system for automated quantitative fluorescence measurements. The device is capable of sampling water autonomously, controlling the whole measurement, storing and transmitting data over GSM networks. We demonstrate highly reproducible measurements of arsenic in drinking water at 10 and 50 μg/L within 100 and 80 min, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For more than 20 years, measurement of catecholamines in plasma and urine in clinical chemistry laboratories has been the cornerstone of the diagnosis of neuroendocrine tumors deriving from the neural crest such as pheochromocytoma (PHEO) and neuroblastoma (NB), and is still used to assess sympathetic stress function in man and animals. Although assay of catecholamines in urine are still considered the biochemical standard for the diagnosis of NB, they have been progressively abandoned for excluding/confirming PHEOs to the advantage of metanephrines (MNs). Nevertheless, catecholamine determinations are still of interest to improve the biochemical diagnosis of PHEO in difficult cases that usually require a clonidine-suppression test, or to establish whether a patient with PHEO secretes high concentrations of catecholamines in addition to metanephrines. The aim of this chapter is to provide an update about the catecholamine assays in plasma and urine and to show the most common pre-analytical and analytical pitfalls associated with their determination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Caffeine extraction procedures from water soluble and water insoluble materials for preparing stimulating beverages are described. Water soluble materials used were instant tea and coffee and water insoluble materials were, among others, guaraná powder and maté leaves. The extraction of caffeine from water soluble materials, especially instant tea, is more suitable for an organic chemistry teaching laboratory than the classic experiment using tea leaves, due to the economy of time and a larger amount of extracted caffeine. The procedure is time-saving and requires only a four-hour period. The experiments illustrate the extraction process as used in undergraduate organic chemistry laboratories.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The silica gel was obtained from sand and its surface was modified with POCl3 to produce Si-Cl bonds on the silica surface. Ethylenediamine was covalently bonded onto the chlorinated silica surface. The adsorption of the chlorides of divalent cobalt, nickel and copper was qualitatively studied to show that the bonding of ethylenediamine onto the silica gel surface produces a solid base capable of chelating metal ions from solution. The experiments illustrate the extraction of silica gel, its reactivity, the development of modified surfaces and its application in removing metal ions from water and are deigned for undergraduate inorganic chemistry laboratories.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present contribution describes three different modern experiments for possible adoption in undergraduate organic chemistry laboratories. These are: 1. electrocatalytic hydrogenation of benzaldehyde to benzyl alcohol; 2. identification of three volatile components, obtained from pineapple fruit, by mass spectrometry and 3. microwave mediated fast synthesis of N-(p-chlorophenyl)phthalamic acid from phthalic anhydride and p-chloroaniline under solvent-free conditions. The experiments can be executed in a short period of time, putting the undergraduate student in contact with a variety of topics in organic chemistry and several techniques of analysis, showing multidisciplinarity in organic chemistry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper focuses on the teaching development practice in the field of chemistry covering such disciplines as chemistry teaching practice, chemistry teaching instrumentation and chemistry teaching methodology and/or didactics, thereby describing and analysing the logics of the development practice and the role of teachers as well as the epistemological identity configurations (knowledges which are proper to said identity) within this discipline field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The discussion among teachers, students, and technicians about the destination of residues from chemistry laboratories led to a research project whose results were incorporated into a course in its daily practices. The treatment of the residues from argentimetric practices allowed us to establish cognitive relations of technological basis and of those related to the rising of the level of awareness about environmental aspects and social responsibility of chemistry professionals. The techniques and the results, from the economic point of view, namely that of value aggregation (metallic silver) and the conversion of the residue into input (potassium chromate solution) are shown.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For some years, Chemistry teachers have used scientific visualization software of molecular models in computing rooms and chemistry laboratories for educational purposes. However, its application in classrooms has been limited. This article describes the integration and use of computer programs for scientific molecular visualization in a traditional classroom. We consider that the improvement of technical aspects of their application and use (usability) has a direct effect on students' understanding of molecular structures (including students' extrinsic motivation), among other factors. Consequently, we developed a guide for the integration of hardware and software of molecular visualization for its use in the classroom.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dibenzalacetone and other aldol condensation products are known sunscreens commonly used in cosmetics. This type of compounds can easily be prepared in an Organic Chemistry Lab by reaction of aldehydes with ketones in basic medium. These compounds can be incorporated in poly(methyl methacrylate) and used as UV light absorbers, for example in sunglasses. This project has the advantage of using inexpensive reagents which are readily available in Chemistry Laboratories. This experiment can also be a base starting point for discussions of organic, polymer and photochemistry topics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Marijuana (Cannabis sativa L.) is the most cultivated, trafficked and consumed illicit drug worldwide. Estimates indicate 10% of individuals experiencing marijuana become daily users, and 20-30% use it weekly. Around 489 natural compounds have been identified in this plant, of which 70 are cannabinoids, responsible for psychic effects. The most relevant cannabinoid is Δ9-THC, recognized as the main chemical substance with psychoactive effects. The aims of this work was to investigate whether other drugs interfere with the colorimetric tests Fast Blue B and Duquenois-Levine, widely used for marijuana screening in forensic chemistry laboratories.