940 resultados para instrument sterilization


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effectiveness of microwave irradiation sterilization on hard chairside reline resins. Materials and Methods: Specimens of three reline resins (Kooliner, Tokuso Rebase, and Ufi Gel Hard) were fabricated and subjected to ethylene oxide sterilization. The specimens were then individually inoculated (107 cfu/mL) with Tryptic Soy Broth media containing one of the tested microorganisms (C albicans, S aureus, B subtilis, and P aeruginosa). After 48 hours at 37°C, the samples were vortexed for 1 minute and allowed to stand for 9 minutes, followed by a short vortex to resuspend any organisms present. After inoculation, 40 specimens of each material were immersed in 200 mL of water and subjected to microwave irradiation at 650 W for 6 minutes. Forty non-irradiated specimens were used as positive controls. Replicate specimens (25 μL) of suspension were plated at dilutions of 10-3 to 10-6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. After incubation, colonies were counted, and the data were statistically analyzed by the Kruskal-Wallis test. Twelve specimens of each material were prepared for SEM. Results: All immersed specimens showed consistent sterilization of all the individual organisms after microwave irradiation. SEM examination indicated an alteration in cell morphology after microwave irradiation. Conclusion: Microwave sterilization for 6 minutes at 650 W proved to be effective for the sterilization of hard chairside reline resins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Difficulties in sterilizing impressions by traditional methods have led to chemical disinfection as an alternative, and some studies have shown that disinfectants may adversely affect impressions. PURPOSE: This study investigated the effect of disinfection methods on the dimensional stability of 6 elastomeric materials. MATERIAL AND METHODS: Impression materials were submitted to the following treatments: immersion in 5.25% sodium hypochlorite solution for 10 minutes, immersion in 2% glutaraldehyde solution for 30 minutes, and no immersion (control). After treatments, impressions were poured, and respective stone casts were measured with a Nikon Profile projector and compared with the master model. RESULTS: The elastomeric materials had different reproduction capacities, and the disinfecting treatments did not differ from the control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study Candida albicans biofilm formation on the surface of commercially pure titanium (cp-Ti) coated with hydroxyapatite was observed by means of scanning electron microscope. The biofilm was formed after 45 days of incubation of the samples in liquid culture medium inoculated with fungus cells in a tube of polystyrene with screw cap and sterilized. After the biofilm removal with 10% EDTA solution was observed pitting on the surface of cp-Ti coated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effectiveness of microwave irradiation on the disinfection of simulated complete dentures. Materials and Methods: Eighty dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated (10 7 cfu/mL) with tryptic soy broth (TSB) media containing one of the tested microorganisms (Candida albicans, Streptoccus aureus, Bacillus subtilis, and Pseudomonas aeruginosa). After 48 hours of incubation at 37°C, 40 dentures were individually immersed in 200 mL of water and submitted to microwave irradiation at 650 W for 6 minutes. Forty nonirradiated dentures were used as positive controls. Replicate aliquots (25 μL) of suspensions were plated at dilutions of 10 -3 to 10 -6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. TSB beakers with the microwaved dentures were incubated at 37°C for 7 more days. After incubation, the number of colony-forming units was counted and the data were statistically analyzed by Kruskal-Wallis test (α = .05). Results: No evidence of growth was observed at 48 hours for S aureus, B subtilis, and C albicans. Dentures contaminated with P aeruginosa showed small growth on 2 plates. After 7 days incubation at 37°C, no growth was visible in the TSB beakers of S aureus and C albicans. Turbidity was observed in 3 broth beakers, 2 from P aeruginosa and 1 from B subtilis. Conclusion: Microwave irradiation for 6 minutes at 650 W produced sterilization of complete dentures contaminated with S aureus and C albicans and disinfection of those contaminated with P aeruginosa and B subtilis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study was conducted to comparatively evaluate, in a prospective and randomized manner, 2 techniques for providing double-gloving protection during arch bar placement for intermaxillary fixation. Materials and Methods: A total of 42 consecutive patients in whom application of an Erich bar was indicated for intermaxillary fixation were equally divided into 2 groups. In group 1, 2 sterile surgical gloves were used; in group 2, a nonsterile disposable inner glove was used under a sterile surgical glove. Wilcoxon, Mann-Whitney, Kruskal-Wallis, and binomial statistical tests were used to analyze the findings. Results: A total of 103 perforations were found in the outer gloves (47 in group 1 and 56 in group 2), along with 5 perforations in inner gloves in both groups (α = .01). No significant statistical difference was found between groups in terms of inner glove perforations (α = .05). The nondominant hand presented with 70.9% of the perforations, statistically significant to 1%. Conclusions: Both double-gloving techniques were found to provide effective clinician protection. The use of a nonsterile disposable glove under the surgical glove is possible for less-invasive procedures, offering the same safety as using 2 sterile surgical gloves while decreasing operational costs. This method does not eliminate the need to change gloves when a perforation is suspected or noted during the surgery, however. © 2007 American Association of Oral and Maxillofacial Surgeons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study evaluated the effectiveness of different exposure times of microwave irradiation on the disinfection of a hard chairside reline resin. Materials and Methods: Sterile specimens were individually inoculated with one of the tested microorganisms (Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans, and Bacillus subtilis) and incubated for 24 hours at 37°C. For each microorganism, 10 specimens were not microwaved (control), and 50 specimens were microwaved. Control specimens were individually immersed in sterile saline, and replicate aliquots of serial dilutions were plated on selective media appropriate for each organism. Irradiated specimens were immersed in water and microwaved at 650 W for 1, 2, 3, 4, or 5 minutes before serial dilutions and platings. After 48 hours of incubation, colonies on plates were counted. Irradiated specimens were also incubated for 7 days. Some specimens were prepared for scanning electron microscopic (SEM) analysis. Results: Specimens irradiated for 3, 4, and 5 minutes showed sterilization. After 2 minutes of irradiation, specimens inoculated with C. albicans were sterilized, whereas those inoculated with bacteria were disinfected. One minute of irradiation resulted in growth of all microorganisms. SEM examination indicated alteration in cell morphology of sterilized specimens. The effectiveness of microwave irradiation was improved as the exposure time increased. Conclusion: This study suggests that 3 minutes of microwave irradiation can be used for acrylic resin sterilization, thus preventing cross-contamination. © 2008 by The American College of Prosthodontists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Ozone has been used as an alternative method for the decontamination of water, food, equipment and instruments. The objective of this study was to evaluate the antimicrobial effects of ozonated water on the sanitization of dental instruments that were contaminated by Escherichia coli, Staphylococcus aureus, Candida albicans and the spores of Bacillus atrophaeus. Methods: A total of one hundred and twenty standardized samples of diamond dental burs were experimentally contaminated with E. coli (ATCC 25922), S. aureus (ATCC 6538) and C. albicans (ATCC 18804) and the spores of B. atrophaeus (ATCC 6633) for 30min. After the contamination, the samples were exposed to ozonated water (10mg/L O3) for 10 or 30min. The control group was composed of samples that were exposed to distilled water for 30min. After the exposure to the ozonated water, 0.1mL aliquots were seeded onto BHI agar to count the colony-forming units per milliliter (CFU/mL) of E. coli, S. aureus, and B. atrophaeus. Sabouraud dextrose agar was used to count the CFU/mL of C. albicans. The results were subjected to an analysis of variance and the Tukey test. Results: For all of the microorganisms studied, the ozonated water reduced the number of CFU/mL after 10 and 30. min of sanitization, and this microbial reduction was dependent on the duration of the exposure to the ozonated water. E. coli exhibited the greatest reduction in CFU/mL (2.72-3.78. log) followed by S. aureus (2.14-3.19. log), C. albicans (1.44-2.14. log) and the spores of B. atrophaeus (1.01-1.98. log). Conclusion: The ozonated water was effective in reducing the CFU of E. coli, S. aureus, C. albicans and B. atrophaeus spores, suggesting that ozonated water can be used for the sanitization of dental instruments. © 2012 King Saud Bin Abdulaziz University for Health Sciences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hardness, roughness and mass loss of an acrylic denture base resin after in vitro exposure to four disinfectant solutions. Forty specimens (Clássico, Brazil) were prepared and randomly assigned to 4 groups n = 10) according to the disinfectant solution: G1: control, stored in distilled water at 37 degrees C; G2: 1% sodium hypochlorite; G3: 2% glutaraldehyde; G4: 4% chlorhexidine. G2 to G4 were immersed for 60 minutes in the disinfectant solution. Measurements were carried out both before and after immersion in the solution. The surface was analyzed with a surface roughness tester (Surfcorder SE 1700 KOZAKALAB), a microdurometer FM-700 (Future Tech) and a scanning electron microscope (DSM 962-ZEISS). Loss of mass was determined with a digital weighing scale. After disinfection procedures, values were analyzed statistically. The acrylic denture base resin may be vulnerable to surface changes after in vitro immersion in the disinfectant solutions studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silk fibroin has been widely explored for many biomedical applications, due to its biocompatibility and biodegradability. Sterilization is a fundamental step in biomaterials processing and it must not jeopardize the functionality of medical devices. The aim of this study was to analyze the influence of different sterilization methods in the physical, chemical, and biological characteristics of dense and porous silk fibroin membranes. Silk fibroin membranes were treated by several procedures: immersion in 70% ethanol solution, ultraviolet radiation, autoclave, ethylene oxide, and gamma radiation, and were analyzed by scanning electron microscopy, Fourier-transformed infrared spectroscopy (FTIR), X-ray diffraction, tensile strength and in vitro cytotoxicity to Chinese hamster ovary cells. The results indicated that the sterilization methods did not cause perceivable morphological changes in the membranes and the membranes were not toxic to cells. The sterilization methods that used organic solvent or an increased humidity and/or temperature (70% ethanol, autoclave, and ethylene oxide) increased the silk II content in the membranes: the dense membranes became more brittle, while the porous membranes showed increased strength at break. Membranes that underwent sterilization by UV and gamma radiation presented properties similar to the nonsterilized membranes, mainly for tensile strength and FTIR results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

to assess the construct validity and reliability of the Pediatric Patient Classification Instrument. correlation study developed at a teaching hospital. The classification involved 227 patients, using the pediatric patient classification instrument. The construct validity was assessed through the factor analysis approach and reliability through internal consistency. the Exploratory Factor Analysis identified three constructs with 67.5% of variance explanation and, in the reliability assessment, the following Cronbach's alpha coefficients were found: 0.92 for the instrument as a whole; 0.88 for the Patient domain; 0.81 for the Family domain; 0.44 for the Therapeutic procedures domain. the instrument evidenced its construct validity and reliability, and these analyses indicate the feasibility of the instrument. The validation of the Pediatric Patient Classification Instrument still represents a challenge, due to its relevance for a closer look at pediatric nursing care and management. Further research should be considered to explore its dimensionality and content validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improve the content validity of the instrument for classification of pediatric patients and evaluate its construct validity. A descriptive exploratory study in the measurement of the content validity index, and correlational design for construct validation through exploratory factor analysis. The content validity index for indicators was 0.99 and it was 0.97 for graded situations. Three domains were extracted in the construct validation, namely: patient, family and therapeutic procedures, with 74.97% of explained variance. The instrument showed evidences of content and construct validity. The validation of the instrument occurred under the approach of family-centered care, and allowed incorporating some essential needs of childhood such as playing, interaction and affection in the content of the instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent fears of terrorism have provoked an increase in delays and denials of transboundary shipments of radioisotopes. This represents a serious constraint to sterile insect technique (SIT) programs around the world as they rely on the use of ionizing radiation from radioisotopes for insect sterilization. To validate a novel X ray irradiator, a series of studies on Ceratitis capitata (Wiedemann) and Anastrepha fraterculus (Wiedemann) (Diptera: Tephritidae) were carried out, comparing the relative biological effectiveness (RBE) between X rays and traditional gamma radiation from (60)Co. Male C. capitata pupae and pupae of both sexes of A. fraterculus, both 24 - 48 h before adult emergence, were irradiated with doses ranging from 15 to 120 Gy and 10-70 Gy, respectively. Estimated mean doses of 91.2 Gy of X and 124.9 Gy of gamma radiation induced 99% sterility in C. capitata males, Irradiated A. fraterculus were 99% sterile at approximate to 40-60 Gy for both radiation treatments. Standard quality control parameters and mating indices were not significantly affected by the two types of radiation. The RBE did not differ significantly between the tested X and gamma radiation, and X rays are as biologically effective for SIT purposes as gamma rays are. This work confirms the suitability of this new generation of X ray irradiators for pest control programs that integrate the SIT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethylene oxide (EO) is used to sterilize Oxygenator and Tubing applied to heart surgery. Residual levels of EO and its derivatives, ethylene chlorohydrin (ECH) and ethylene glycol (EG), may be hazardous to the patients. Therefore, it must be removed by the aeration process. This study aimed to estimate the minimum aeration time for these devices to attain safe limits for use (avoiding excessive aeration time) and to evaluate the Green Fluorescent Protein (GFP) as a biosensor capable of best indicating the distribution and penetration of EO gas throughout the sterilization chamber. Sterilization cycles of 2, 4, and 8 h were monitored by Bacillus atrophaeus ATCC 9372 as a biological indicator (131) and by the GFP. Residual levels of EO, ECH, and EG were determined by gas chromatography (GC), and the residual dissipation was studied. Safe limits were reached right after the sterilization process for Oxygenator and after 204 h of aeration for Tubing. In the 2 h cycle, the GFP concentration decreased from 4.8 (+/- 3.2)% to 7.5 (+/- 2.5)%. For the 4 h cycle, the GFP concentration decreased from 17.4 (+/- 3.0)% to 21.5 (+/- 6.8)%, and in the 8 h cycle, it decreased from 22.5 (+/- 3.2)% to 23.9 (+/- 3.9)%. This finding showed the potentiality for GFP applications as an EO biosensor. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 9113: 626-630, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma is an innovative sterilization method characterized by a low toxicity to operators and patients, and also by its operation at temperatures close to room temperatures. The use of different parameters for this method of sterilization and the corresponding results were analyzed in this study. A low-pressure inductive discharge was used to study the plasma sterilization processes. Oxygen and a mixture of oxygen and hydrogen peroxide were used as plasma source gases. The efficacy of the processes using different combinations of parameters such as plasma-generation method, type of gas, pressure, gas flow rate, temperature, power, and exposure time was evaluated. Two phases were developed for the processes, one using pure oxygen and the other a mixture of gases. Bacillus subtilis var. niger ATCC 9372 (Bacillus atrophaeus) spores inoculated on glass coverslips were used as biological indicators to evaluate the efficacy of the processes. All cycles were carried out in triplicate for different sublethal exposure times to calculate the D value by the enumeration method. The pour-plate technique was used to quantify the spores. D values of between 8 and 3 min were obtained. Best results were achieved at high power levels (350 and 40oW) using pure oxygen, showing that plasma sterilization is a promising alternative to other sterilization methods. (c) 2007 Elsevier B.V. All rights reserved.