995 resultados para indirect ice detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wind energy is one of the most promising and fast growing sector of energy production. Wind is ecologically friendly and relatively cheap energy resource available for development in practically all corners of the world (where only the wind blows). Today wind power gained broad development in the Scandinavian countries. Three important challenges concerning sustainable development, i.e. energy security, climate change and energy access make a compelling case for large-scale utilization of wind energy. In Finland, according to the climate and energy strategy, accepted in 2008, the total consumption of electricity generated by means of wind farms by 2020, should reach 6 - 7% of total consumption in the country [1]. The main challenges associated with wind energy production are harsh operational conditions that often accompany the turbine operation in the climatic conditions of the north and poor accessibility for maintenance and service. One of the major problems that require a solution is the icing of turbine structures. Icing reduces the performance of wind turbines, which in the conditions of a long cold period, can significantly affect the reliability of power supply. In order to predict and control power performance, the process of ice accretion has to be carefully tracked. There are two ways to detect icing – directly or indirectly. The first way applies to the special ice detection instruments. The second one is using indirect characteristics of turbine performance. One of such indirect methods for ice detection and power loss estimation has been proposed and used in this paper. The results were compared to the results directly gained from the ice sensors. The data used was measured in Muukko wind farm, southeast Finland during a project 'Wind power in cold climate and complex terrain'. The project was carried out in 9/2013 - 8/2015 with the partners Lappeenranta university of technology, Alstom renovables España S.L., TuuliMuukko, and TuuliSaimaa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A capillary electrophoresis method for organic acids in wine was developed and validated. The optimal electrolyte consisted of 10 mmol/L 3,5-dinitrobenzoic acid (DNB) at pH 3.6 containing 0.2 mmol/L cetyltrimethylammonium bromide as flow reverser. DNB was chosen because it has an effective mobility similar to the organic acids under investigation, good buffering capacity at pH 3.6, and good chromophoric characteristics for indirect UV-absorbance detection at 254 nm. Sample preparation involved dilution and filtration. The method showed good performance characteristics: Linearity at 6 to 285 mg/L (r > 0.99); detection and quantification limits of 0.64 to 1.55 and 2.12 to 5.15 mg/L, respectively; separation time of less than 5.5 min. Coefficients of variation for ten injections were less than 5% and recoveries varied from 95% to 102%. Application to 23 samples of Brazilian wine confirmed good repeatability and demonstrated wide variation in the organic acid concentrations. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reversed-phase high performance liquid chromatographic methods for the analysis of Haloacetic acids have been developed and compared to conventional direct detection methods. Haloacetic acids commonly found in drinking water, including monochloro-, dichloro-, bromo-, iodo- and trichloroacetic acids- have been studied. The ion pairing agent benzyltributylammonium ion was studied in detail using indirect UV and indirect fluorescence detection. Five different competing ions were evaluated to decrease analysis times and lower the detection limit by this new method. The direct detection method utilized an ammonium sulfate buffer and UV detection yielding a detection limit of 100 ppb. The indirect method developed has the advantage of being able to simultaneously analyze UV and non-UV absorbing ions and molecules but requires long equilibration times and demonstrated lower sensitivity than the direct method. ^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with tris(2,2'-bipyridyl) ruthenium (II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of four polyamines (putrescine (Put), cadaverine (Cad), spermidine (Spd), and spermine (Spm)) analysis. The four polyamines contain different amine groups, which have different ECL activity. There are several parameters which influence the resolution and ECL peak intensities, including the buffer pH and concentrations, separation voltage, sample injection, electrode materials, and Ru(bpy)(3)(2+) concentrations. Polyamines are separated by capillary zone electrophoresis in an uncoated fused-silica capillary (50 cm x 25 mum (ID) filled with acidic phosphate buffer (200 mmol/L phosphate, pH 2.0) - 1 mol/L phosphoric acid (9:1 v/v) and a separation voltage of 5 kV (25 muA), with end-column Ru(bpy)(3)(2+) ECL detection. A 5 mmol/L Ru(bpy)(3)(2+) solution plus 200 mmol/L phosphate buffer (pH 11.0) is added into the reagent reservoir. The calibration curve is linear over a concentration range of two or three orders of magnitude for the polyamines. The analysis time is less than 25 min. Detection limits for Put and Cad are 1.9 x 10(-7) mol/L and 7.6 x 10(-9) mol/L for Spd and Spm, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A capillary zone electrophoresis method using indirect UV detection for the analysis of chloride and sulfate in alcohol fuel samples was developed. The anions were analyzed in less than 3 min using an electrolyte containing 10 mmol 1(-1) chromate and 0.75 mmol 1(-1) hexamethonium bromide (HMB) as electroosmotic flow modifier. Coefficients of variation were better than 0.6% for migration time (n = 10) and between 2.05 and 2.82% for peak area repeatabilities. Analytical curves of peak area versus concentration in the range of 0.065-0.65 mg kg(-1) for chloride and 0.25-4.0 mg kg(-1) for sulfate were linear with coefficients of correlation higher than 0.9996. The limits of detection for sulfate and chloride were 0.033 and 0.041 mg kg(-1), respectively. Recovery values ranged from 85 to 103%. The method was successfully applied for the quantification of sulfate and chloride in five alcohol fuel samples. The concentration of sulfate varied from 0.45 to 3.12 mg kg(-1). Chloride concentrations were below the method's LOD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a site-resolved study of stow (ms to s) motions in a protein in the solid (microcrystalline) state performed with the use of a modified version of the centerband-only detection of exchange (CODEX) NMR experiment. CODEX was originally based on measuring changes in molecular orientation by means of the chemical shift anisotropy (CSA) tensor, and in our modification, angular reorientations of internuclear vectors are observed. The experiment was applied to the study of stow (15)N-(1)H motions of the SH3 domain of chicken a-spectrin. The protein was perdeuterated with partial back-exchange of protons at labile sites. This allowed indirect (proton) detection of (15)N nuclei and thus a significant enhancement of sensitivity. The diluted proton system also made negligible proton-driven spin diffusion between (15)N nuclei, which interferes with the molecular exchange (motion) and hampers the acquisition of dynamic parameters. The experiment has shown that approximately half of the peaks in the 2D (15)N-(1)H correlation spectrum exhibit exchange in a different extent. The correlation time of the slow motion for most peaks is 1 to 3 s. This is the first NMR study of the internal dynamics of proteins in the solid state on the millisecond to second time scale with site-specific spectral resolution that provides both time-scale and geometry information about molecular motions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An alternative method for determination of total trans fatty acids expressed as elaidic acid by capillary zone electrophoresis (CZE) under indirect UV detection at 224 nm within an analysis time of 7.5 min was developed. The optimized running electrolyte includes 15.0 mmol L(-1) KH(2)PO(4)/Na(2)HPO(4) buffer (pH similar to 7.0), 4.0 mmol L(-1) SDBS, 8.0 mmol L(-1) Brij35, 45%v/v ACN, 8% methanol, and 1.5% v/v n-octanol. Baseline separation of the critical pair C18-9cis/C18:1-9t: with a resolution higher than 1.5 was achieved using C15:0 as the internal standard. The optimum capillary electrophoresis (CE) conditions for the background electrolyte were established with the aid of Raman spectroscopy and experiments of a 3(2) factorial design. After response factor (R(F)) calculations, the CE method was applied to total trans fatty acid (TTFA) analysis in a hydrogenated vegetable fat (HVF) sample, and compared with the American Oil Chemists` Society (AOCS) official method by gas chromatography (GC). The methods were compared with an independent sample t test, and no significant difference was found between CE and GC methods within the 95% confidence interval for six genuine replicates of TTFA analysis (p-value > 0.05). The CE method was applied to TTFA analysis in a spreadable cheese sample. Satisfactory results were obtained, indicating that the optimized methodology can be used for trans fatty acid determination for these samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of inorganic cations (Na(+), K(+), Ca(2+), Mg(2+)) in biodiesel samples, using barium (Ba(2+)) as the internal standard. The running electrolyte was optimized through effective mobility curves in order to select the co-ion and Peakmaster software was used to determine electromigration dispersion and buffer capacity. The optimum background electrolyte was composed of 10 mmol L(-1) imidazole and 40 mmol L(-1) of acetic acid. Separation was conducted in a fused-silica capillary (32 cm total length and 23.5 cm effective length, 50 mu m I.D.), with indirect UV detection at 214 nm. The migration time was only 36 s. In order to obtain the optimized conditions for extraction, a fractional factorial experimental design was used. The variables investigated were biodiesel mass, pH, extractant volume, agitation and sonication time. The optimum conditions were: biodiesel mass of 200 mg, extractant volume of 200 mu L. and agitation of 20 min. The method is characterized by good linearity in the concentration range of 0.5-20 mg kg(-1) (r > 0.999), limit of detection was equal to 0.3 mg kg(-1), inter-day precision was equal to 1.88% and recovery in the range of 88.0-120%. The developed method was successfully applied to the determination of cations in biodiesel samples. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a CE method for the determination of olive oil acidity was proposed. The method was based on an ethanolic extraction (at 60 degrees C) of the oil long-chain free fatty acids (LC-FFAs) components followed by CE determination in pH 6.86 phosphate buffer at 15 mmol/L concentration containing 4 mmol/L sodium dodecylbenzenesulfonate (SDBS), 10 mmol/L polyoxyethylene 23 lauryl ether (Brij 35((R))), 2% v/v 1-octanol and 45% v/v ACN under indirect UV detection at 224 nm. Although this electrolyte promoted baseline separation of myristic acid (C14:0) (internal standard (IS)) and olive oil major components (palmitic acid (C16:0), oleic acid (C18:1c) and linoleic acid (C18:2cc)) in less than 8 min, after a few injections, the electropherogram profiles were severely altered (peak broadening, migration time shifts, etc.) and the current increased substantially. An adsorption study was conducted revealing that the dissolution of the capillary external polyimide coating during the electrophoretic run caused the detrimental effect. After removal of the capillary tip coating, ten consecutive injections could be performed without any disturbances and this simple procedure was, therefore, implemented during quantitative purposes. The reliability of the proposed method was further investigated by the determination of acidity of an extra virgin olive oil sample in comparison to the established methodology (AOCS method Ca 5a40, alkaline volumetric titration (AVT)). No statistical differences were found within 95% confidence level. A % acidity of 0.39 +/- 0.02 was found for the olive oil sample under consideration.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5% v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS² results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2 μg/mL (extracts).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trichinellosis is a food-borne zoonotic disease caused by the nematode Trichinella spp. Many omnivorous and carnivorous animal species can act as host for this parasite, including domestic pigs. To protect public health, it should be ensured that pork should not contain infective Trichinella larvae. Surveillance for Trichinella spp. can be done using direct (larval detection) and indirect (antibody detection) diagnostic techniques. The aim of this study was to demonstrate the absence of infection in Swiss domestic pigs. An ELISA was used as the initial screening test, and sera reacting in ELISA were further investigated using both a Western blot for serology and an artificial digestion test with 20 g of diaphragm tissue for larval detection. A total of 7412 adult pigs, 9973 finishing pigs and 2779 free-ranging pigs were tested. Samples from 17 (0.23%) adult pigs, 16 (0.16%) finishing pigs and nine (0.32%) free-ranging pigs were ELISA-positive, but all of these sera were subsequently negative by Western blot and by the artificial digestion method. Based on these findings, an absence of Trichinella infections in adult pigs (target prevalence 0.04%) and finishing pigs (target prevalence 0.03%) can be concluded. The results also demonstrated that the prevalence of Trichinella infections does not exceed 0.11% in free-ranging pigs, the group with the highest risk of exposure.