16 resultados para inclinometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Establish intra- and inter-examiner reliability of glenohumeral range of motion (ROM) measures taken by a single-clinician using a mechanical inclinometer. Design: A single-session, repeated-measure, randomized, counterbalanced design. Setting: Athletic Training laboratory. Participants: Ten college-aged volunteers (9 right-hand dominant; 4 males, 6 females; age=23.2±2.4y, mass=73±16kg, height=170±8cm) without shoulder or neck injuries within one year. Interventions: Two Certified Athletic Trainers separately assessed passive glenohumeral (GH) internal (IR) and external (ER) rotation bilaterally. Each clinician secured the inclinometer to each subject’s distal forearm using elastic straps. Clinicians followed standard procedures for assessing ROM, with the participants supine on a standard treatment table with 90° of elbow flexion. A second investigator recorded the angle. Clinicians measured all shoulders once to assess inter-clinician reliability and eight shoulders twice to assess intra-clinician reliability. We used SPSS 14.0 (SPSS Inc., Chicago, IL) to calculate standard error of measure (SEM) and Intraclass Correlation Coefficients (ICC) to evaluate intra- and inter-clinician reliability. Main Outcome Measures: Dependent variables were degrees of IR, ER, glenohumeral internal rotation deficit (GIRD) and total arc of rotation. We calculated GIRD as the bilateral difference in IR (nondominant–dominant) and total arc for each shoulder (IR+ER). Results: Intra-clinician reliability for each examiner was excellent (ICC[1,1] range=0.90-0.96; SEM=2.2°-2.5°) for all measures. Examiners displayed excellent inter-clinician reliability (ICC[2,1] range=0.79-0.97; SEM=1.7°-3.0°) for all measures except nondominant IR which had good reliability(0.72). Conclusions: Results suggest that clinicians can achieve reliable measures of GH rotation and GIRD using a single-clinician technique and an inexpensive, readily available mechanical inclinometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the intrarater and interrater reliability among rheumatologists of a standardised protocol for measurement of shoulder movements using a gravity inclinometer. Methods: After instruction, six rheurnatologists independently assessed eight movements of the shoulder, including total and glenohumeral flexion, total and glenohumeral abduction, external rotation in neutral and in abduction, internal rotation in abduction and hand behind back, in random order in six patients with shoulder pain and stiffness according to a 6x6 Latin square design using a standardised protocol. These assessments were then repeated. Analysis of variance was used to partition total variability into components of variance in order to calculate intraclass correlation coefficients (ICCs). Results: The intrarater and interrater reliability of different shoulder movements varied widely. The movement of hand behind back and total shoulder flexion yielded the highest ICC scores for both intrarater reliability (0.91 and 0.83, respectively) and interrater reliability (0.80 and 0.72, respectively). Low ICC scores were found for the movements of glenohumeral abduction, external rotation in abduction, and internal rotation in abduction (intrarater ICCs 0.35, 0.43, and 0.32, respectively), and external rotation in neutral, external rotation in abduction, and internal rotation in abduction (interrater ICCs 0.29, 0.11, and 0.06, respectively). Conclusions: The measurement of shoulder movements using a standardised protocol by rheumatologists produced variable intrarater and interrater reliability. Reasonable reliability was obtained only for the movement of hand behind back and total shoulder flexion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inconclusive findings have been shown in previous studies comparing lumbar range of movement (LROM) and lumbar lordosis between back pain patients and healthy subjects. In these studies, confounding variables such as age, gender, height, obesity, and pain level were usually not well controlled. The present study aimed to compare LROM and lumbar lordosis between back pain patients and matched controls. Fifteen male back pain patients and 15 age-, height-, obesity-, and physical activity-matched male controls were investigated. To minimize the effect of pain on the measurements, only patients with minimal or no pain at the time of testing were included in the study. Inclinometer technique was used for the evaluation of LROM in flexion, extension and lateral flexion as well as lumbar lordosis. A lumbar rotameter was used for measuring axial rotation. Pelvic motion was limited by a pelvic restraint device during LROM measurements. Results showed that there were no significant differences between the back pain and control groups in flexion, extension, lateral flexion and axial rotation LROM and also in lumbar lordosis. This may indicate that when a back pain patient is not in pain, LROM and lumbar lordosis may not be the measures that distinguish between back pain patients and subjects without back pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: O Sustained Natural Apophyseal Glide tem sido sugerido como uma técnica com potenciais benefícios na redução da dor e no aumento da amplitude de flexão lombar em indivíduos com dor lombar. Contudo, não existe evidência sobre esta técnica na atividade muscular dos eretores espinhais. Objetivo: Avaliar os efeitos imediatos de um Sustained Natural Apophyseal Glide na atividade muscular dos eretores espinhais, na intensidade da dor e na amplitude real de flexão lombar, em indivíduos com dor lombar crónica não específica. Métodos: Estudo experimental com uma amostra de 20 estudantes universitários, com dor lombar crónica não específica e com dor à flexão da coluna lombar, que foram aleatoriamente distribuídos em dois grupos: experimental - Sustained Natural Apophyseal Glide e placebo – intervenção placebo. Foram avaliadas a atividade muscular dos eretores espinhais recorrendo à eletromiografia de superfície (bioPLUX research®), a intensidade da dor através da Escala Visual Analógica e a amplitude real de flexão lombar pelo método de duplo inclinómetro (Universal Inclinometer®), antes e após a intervenção, pela análise do movimento de flexão-extensão do tronco. O nível de significância foi de 0,05. Resultados: Foram encontradas diferenças significativas, em ambos os grupos, para a fase de relaxamento (Grupo experimental: p=0,013 e Grupo placebo: p=0,047), assim como para a fase de extensão, no grupo experimental (p=0,037), verificando-se uma diminuição da atividade muscular da baseline para a avaliação final. A Análise da Covariância revelou que, relativamente à intensidade da dor, verificaram-se diferenças significativas entre os dois grupos (p=0,002), sendo que o grupo experimental diminuiu mais 2cm na Escala Visual Analógica do que o grupo placebo. Pela análise da amplitude real de flexão lombar, embora o aumento não fosse significativamente diferente entre os grupos (p=0,086), o grupo experimental teve mais 1,7º de aumento do que o grupo placebo. Conclusão: Os resultados sugerem que, a curto prazo, o Sustained Natural Apophyseal Glide parece produzir um efeito significativo na diminuição da atividade muscular dos eretores espinhais, durante o movimento dinâmico de extensão do tronco, assim como no alívio da dor. Embora não se tenham observado alterações significativas no aumento da amplitude articular, os resultados no grupo experimental foram superiores à diferença mínima detetável, sugerindo um efeito positivo da técnica aplicada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Clinicians commonly assess posture in persons with musculoskeletal disorders and tend to do so subjectively. Evidence-based practice requires the use of valid, reliable and sensitive tools to monitor treatment effectiveness. The purpose of this article was to determine which methods were used to assess posture quantitatively in a clinical setting and to identify psychometric properties of posture indices measured from these methods or tools. Methods. We conducted a comprehensive literature review. Pertinent databases were used to search for articles on quantitative clinical assessment of posture. Searching keywords were related to posture and assessment, scoliosis, back pain, reliability, validity and different body segments. Results. We identified 65 articles with angle and distance posture indices that corresponded to our search criteria. Several studies showed good intra- and inter-rater reliability for measurements taken directly on the persons (e.g., goniometer, inclinometer, flexible curve and tape measurement) or from photographs, but the validity of these measurements was not always demonstrated. Conclusion. Taking measurements of all body angles directly on the person is a lengthy process and may affect the reliability of the measurements. Measurement of body angles from photographs may be the most accurate and rapid way to assess global posture quantitatively in a clinical setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]El objetivo del presente proyecto es la programación, mediante la herramienta Labview, de un software para la lectura y almacenamiento de los datos recogidos por un inclinómetro analógico de la marca STW Technic. Una vez el programa esté listo, se procederá a realizar una serie de pruebas mediante vibraciones a distintas frecuencias y con distinta amplitud de ángulo para determinar los límites de medida del sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distribution throughout the anchor fixed length. The horizontal movements were measured with an inclinometer, and the loads in the anchors were measured with strain gages, installed in three places throughout the anchor fixed length. Measurements for displacement were done right after the implementation of each stage of the building and right after the conclusion of the building, and the measurements for loads in the anchors were done during the performance test, at the moment of the locking off and, also, right after the conclusion of the building. From the data of displacement were obtained velocity and acceleration data of wall. It was found that the time elapsed on braced installation was decisive in the magnitude of the displacements. The maximum horizontal displacement of wall ranged between 0,18 and 0,66% of the final depth of excavation. The loads in the anchors strongly reduced to approximately half the anchor fixed length, followed an exponential distribution. Furthermore, it was found that there was a loss of load in the anchors over time, reaching 50% loss in one of them

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The tractors are the main potency source, for the traction of tillage equipments and their use are increasing more and more in Brazilian agriculture. In spite of the great technological progress the increase of the number of agricultural tractors brought positive aspects and some negative, among these last ones it stands out the appearance of a new source of work accidents, which importance is given by the physical damages caused to the operator. Therefore the objective of this work was to project and develop an inclinometer, which indicates the inclination of the land, as safety sensor for agricultural tractors to avoid lateral hollovers, through a resonant sign, for the operator and the machine preservation. The built and evaluated inclinometer showed to be efficient for inclination indication of different areas during field operations with agricultural tractors, small angle oscillation and enough answer time to help operators to take decisions in imminence situation of lateral machine hollovers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this work is to evaluate the geometric accuracy of a prerelease version of a new six degrees of freedom (6DoF) couch. Additionally, a quality assurance method for 6DoF couches is proposed. Methods: The main principle of the performance tests was to request a known shift for the 6DoF couch and to compare this requested shift with the actually applied shift by independently measuring the applied shift using different methods (graph paper, laser, inclinometer, and imaging system). The performance of each of the six axes was tested separately as well as in combination with the other axes. Functional cases as well as realistic clinical cases were analyzed. The tests were performed without a couch load and with a couch load of up to 200 kg and shifts in the range between −4 and +4 cm for the translational axes and between −3° and +3° for the rotational axes were applied. The quality assurance method of the new 6DoF couch was performed using a simple cube phantom and the imaging system. Results: The deviations (mean ± one standard deviation) accumulated over all performance tests between the requested shifts and the measurements of the applied shifts were −0.01 ± 0.02, 0.01 ± 0.02, and 0.01 ± 0.02 cm for the longitudinal, lateral, and vertical axes, respectively. The corresponding values for the three rotational axes couch rotation, pitch, and roll were 0.03° ± 0.06°, −0.04° ± 0.12°, and −0.01° ± 0.08°, respectively. There was no difference found between the tests with and without a couch load of up to 200 kg. Conclusions: The new 6DoF couch is able to apply requested shifts with high accuracy. It has the potential to be used for treatment techniques with the highest demands in patient setup accuracy such as those needed in stereotactic treatments. Shifts can be applied efficiently and automatically. Daily quality assurance of the 6DoF couch can be performed in an easy and efficient way. Long-term stability has to be evaluated in further tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocean Drilling Program (ODP) Sites 832 and 833 were drilled in the intra-arc North Aoba Basin of the New Hebrides Island Arc (Vanuatu). High volcanic influxes in the intra-arc basin sediment resulting from erosion of volcanic rocks from nearby islands and from volcanic activity are associated with characteristic magnetic signals. The high magnetic susceptibility in the sediment (varying on average from 0.005 to more than 0.03 SI) is one of the most characteristic physical properties of this sedimentary depositional environment because of the high concentration of magnetites in redeposited ash flows and in coarse-grained turbidites. Susceptibility data correlate well with the high resolution electrical resistivity logs recorded by the formation microscanner (FMS) tool. Unlike the standard geophysical logs, which have low vertical resolution and therefore smooth the record of the sedimentary process, the FMS and whole-core susceptibility data provide a clearer picture of turbiditic sediment deposition. Measurements of Curie temperatures and low-temperature susceptibility behavior indicate that the principal magnetic minerals in ash beds, silt, and volcanic sandstone are Ti-poor titanomagnetite, whereas Ti-rich titanomagnetites are found in the intrusive sills at the bottom of Site 833. Apart from an increase in the concentration of magnetite in the sandstone layer, acquisition of isothermal and anhysteretic remanences does not show significant differences between sandstone and clayey silts. The determination of the anisotropy of magnetic susceptibility (AMS) in more than 400 samples show that clayey siltstone have a magnetic anisotropy up to 15%, whereas the AMS is much reduced in sandstone layers. The magnetic susceptibility fabric is dominated by the foliation plane, which is coplanar to the bedding plane. Reorientations of the samples using characteristic remanent magnetizations indicate that the bedding planes dip about 10° toward the east, in agreement with results from FMS images. Basaltic sills drilled at Site 833 have high magnetic susceptibilities (0.05 to 0.1 SI) and strong remanent magnetizations. Magnetic field anomalies up to 50 µT were measured in the sills by the general purpose inclinometer tool (GPIT). The direction of the in-situ magnetic anomaly vectors, calculated from the GPIT, is oriented toward the southeast with shallow inclinations which suggests that the sill intruded during a reversed polarity period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Welding is one of the most employed process for joining steel pipes. Although, manual welding is still the most used one, mechanized version and even automatized one have increased its demand. Thus, this work deals with girth welding of API 5L X65 pipes with 8” of nominal diameter and 8.0 mm thickness, beveled with V-30º narrow gap. Torch is moved by a bug carrier (mechanized welding) and further the parameters are controlled as a function of angular position (automatized welding). Welding parameters are presented for filling the joint with two-passes (root and filling/capping passes). Parameters for the root pass were extracted from previous author´s work with weldments carried out in plates, but validated in this work for pipe welding. GMAW processes were assessed with short-circuit metal transfer in both conventional and derivative modes using different technologies (RMD, STT and CMT). After the parameter determination, mechanical testing was performed for welding qualification (uniaxial tension, face and root bending, nick break, Charpy V-notch impact, microhardness and macrograph). The initially obtained results for RMD and CMT were acceptable for all testing and, in a second moment, also for the STT. However, weld beads carried out by using the conventional process failed and revealed the existence of lack of fusion, which required further parametrization. Thus, a Parameter-Variation System for Girth Welding (SVP) was designed and built to allow varying the welding parameters as a function of angular position by using an inclinometer. The parameters were set for each of the three angular positions (flat, vertical downhill and overhead). By using such equipment and approach, the conventional process with parameter variation allowed reducing the welding time for joint accomplishment of the order of 38% for the root pass and 30% for the filling/capping pass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este trabajo se realizan simulaciones de excavaciones profundas en suelos de origen aluvial en la ciudad de Sabaneta, mediante el empleo de modelos en elementos finitos integrados por el software PLAXIS® -- Los desplazamientos horizontales son comparados con mediciones de inclinómetros instalados en el trasdós del muro diafragma anclado del proyecto Centro Comercial Mayorca Fase III, localizado en el municipio de Sabaneta, Antioquia -- Finalmente, se concluye acerca de la sensibilidad de los parámetros más relevantes según el modelo constitutivo empleado y la viabilidad en su aplicación para la solución del problema evaluado