263 resultados para incisional hernia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Incisional hernia (IH) is one of the most frequent postoperative complications. Of all patients undergoing IH repair, a vast amount have a hernia which can be defined as a large incisional hernia (LIH). The aim of this study is to identify the preferred technique for LIH repair. METHODS: A systematic review of the literature was performed and studies describing patients with IH with a diameter of 10 cm or a surface of 100 cm2 or more were included. Recurrence hazards per year were calculated for all techniques using a generalized linear model. RESULTS: Fifty-five articles were included, containing 3,945 LIH repairs. Mesh reinforced techniques displayed better recurrence rates and hazards than techniques without mesh reinforcement. Of all the mesh techniques, sublay repair, sandwich technique with sublay mesh and aponeuroplasty with intraperitoneal mesh displayed the best results (recurrence rates of <3.6%, recurrence hazard <0.5% per year). Wound complications were frequent and most often seen after complex LIH repair. CONCLUSIONS: The use of mesh during LIH repair displayed the best recurrence rates and hazards. If possible mesh in sublay position should be used in cases of LIH repair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniárioem ponte . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a telaem ponte tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocadaem ponte .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incisional hernia is a common complication after liver transplantation. The current study evaluated incidence and risk factors for incisional hernia and compared laparoscopic and open hernia repair in terms of feasibility and outcome.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incisional hernia is one of the most common complications of laparotomy. Its repair with prosthesis has enabled a considerable improvement in the outcome, significantly reducing recurrences. This study analyses the results of open hernioplasty with mesh performed as a Day Surgery procedure in 42 patients between November 2008 and October 2010. The results were good, with low postoperative morbidity and recurrences (2.4%).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

O achado de ossificação heterotópica (OH) sobre cicatriz cirúrgica abdominal é um evento raro, mas que soma morbidade ao paciente. Manifesta-se por dor, endurecimento ou desconforto na cicatriz, levando a novas abordagens cirúrgicas. Relatamos um caso de OH no saco herniário incisional com o objetivo precípuo de chamar a atenção para o potencial "totipotente" do fibroblasto, já que sua íntima relação com a OH é inegável. A partir dessa prerrogativa, qualquer forma de tratamento das hérnias incisionais deveria associar o reparo tecidual ao uso de prótese (tela), para enriquecê-lo com os fibroblastos e seus fatores de crescimento celular do próprio paciente, todos autólogos e prontos para uso. A tática é oferecer uma abordagem combinada ou mista, com menores chances de recidiva na correção dessas afecções.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Los defectos herniarios inguinales son una condición con alta prevalencia en nuestra población. En los últimos años la introducción de la cirugía laparoscopia para la corrección de esta patología ha tomado fuerza gradualmente. El propósito del presente trabajo es describir la experiencia en el uso de esta técnica quirúrgica en una institución hospitalaria. Materiales y métodos: estudio descriptivo de corte trasversal en el cual se revisaron las historias clínica de cada uno de los sujetos llevados a herniorrafia inguinal laparoscópica, donde se evaluaron las características pre y postoperatorias de los casos, así como las complicaciones derivadas del procedimiento. Resultados: Se evaluaron un total de 250 pacientes para un total de 334 Herniorrafias. El promedio de edad fue 58,3 años. La relación hombre mujer fue 3,7: 1. Del total de procedimientos 168 correspondieron a defectos bilaterales. 32 pacientes tenían antecedentes de herniorrafia previa. Se presentaron un total de tres complicaciones. El promedio general de tiempo quirúrgico fue de 69,3 minutos. El seguimiento post operatorio evidencio al dolor inguinal agudo como el principal proceso patológico derivado. El promedio de tiempo de incapacidad en total fue 8,3 días. Se encontró reproducción de la hernia comprobado por ecografía en 10 pacientes. No se produjo ninguna mortalidad en los pacientes del estudio. Conclusiones: La corrección laparoscopia se ha convertido en una alternativa segura y eficiente en el tratamiento definitivo de los defectos herniarios inguinales y debe ser tenida en cuenta en el momento de seleccionar la vía de acceso.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context - Correction of voluminous hernias and large abdominal wall defects is a big challenge in surgical practice due to technical difficulties and the high incidence of respiratory and cardiovascular complications. Objectives - To present the authors experience with inducing progressive pneumoperitoneum preoperative to surgical treatment of voluminous hernias of the abdominal wall. Methods - Retrospective study of six patients who presented voluminous hernias of the abdominal wall and were operated after installation of a pneumoperitoneum. The procedure was performed by placing a catheter in the abdominal cavity at the level of the left hypochondrium with ambient air insufflation for 10 to 15 days. Results - Four of the six patients were female and two male. Ages ranged from 42 to 62 years. Hernia duration varied from 5 to 40 years. Four patients had incisional, one umbilical, and one inguinal hernias. Mean pneumoperitoneum time was 11.6 days. There were no complications related to pneumoperitoneum installation and maintenance. All hernias were corrected without technical difficulties. The Lichtenstein technique was used to correct the inguinal hernia, peritoneal aponeurotic transposition for one of the incisional hernias, with the rest corrected using polypropylene mesh. One death and one wall infection were observed post operatively. No recurrences were reported until now, in 4 to 36 months of follow-up. Conclusion - Preoperative progressive pneumoperitoneum is a safe and easy executed procedure, which simplifies surgery and reduces post-operative respiratory and cardiovascular complications. It is indicated for patients with hernias that have lost the right of domain in the abdominal cavity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Prosthetic meshes are commonly used to correct abdominal wall defects. However, the inflammatory reaction induced by these devices in the peritoneum is not completely understood. We hypothesized that nitric oxide (NO), produced by nitric oxide synthase 2 (NOS2) may modulate the response induced by mesh implants in the abdominal wall and, consequently, affect the outcome of the surgical procedure. Polypropylene meshes were implanted in the peritoneal side of the abdominal wall in wild-type and NOS2-deficient (NOS2(-/-)) mice. After 15 days tissues around the mesh implant were collected, and inflammatory markers (the cytokine interleukin 1 beta (IL-1 beta) and NO) and tissue remodeling (collagen and metalloproteinases (MMP) 2 and 9) were analyzed. The lack of NOS2-derived NO induced a higher incidence of visceral adhesions at the mesh implantation site compared with wild-type mice that underwent the same procedure (P < 0.05). Additionally, higher levels of IL-1 beta were present in the mesh-implanted NOS2(-/-) animals compared with control and wild-type mice. Mesh implantation induced collagen I and III deposition, but in smaller amounts in NOS2(-/-) mice. MMP-9 activity after the surgical procedure was similarly increased in both groups. Conversely, MMP-2 activity was unchanged in mesh-implanted wild-type mice, but was significantly increased in NOS2(-/-) mice (P < 0.01), due to decreased S-nitrosylation of the enzyme in these animals. We conclude that NOS2-derived NO is crucial for an adequate response to and integration of polypropylene mesh implants in the peritoneum. NO deficiency results in a prolonged inflammatory reaction to the mesh implant, and reduced collagen deposition may contribute to an increased incidence of visceral adhesions. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.