967 resultados para in-beam PET
Resumo:
Real structures can be thought as an assembly of components, as for instances plates, shells and beams. This later type of component is very commonly found in structures like frames which can involve a significant degree of complexity or as a reinforcement element of plates or shells. To obtain the desired mechanical behavior of these components or to improve their operating conditions when rehabilitating structures, one of the eventual parameters to consider for that purpose, when possible, is the location of the supports. In the present work, a beam-type structure is considered, and for a set of cases concerning different number and types of supports, as well as different load cases, the authors optimize the location of the supports in order to obtain minimum values of the maximum transverse deflection. The optimization processes are carried out using genetic algorithms. The results obtained, clearly show a good performance of the approach proposed. © 2014 IEEE.
Resumo:
Beam-like structures are the most common components in real engineering, while single side damage is often encountered. In this study, a numerical analysis of single side damage in a free-free beam is analysed with three different finite element models; namely solid, shell and beam models for demonstrating their performance in simulating real structures. Similar to experiment, damage is introduced into one side of the beam, and natural frequencies are extracted from the simulations and compared with experimental and analytical results. Mode shapes are also analysed with modal assurance criterion. The results from simulations reveal a good performance of the three models in extracting natural frequencies, and solid model performs better than shell while shell model performs better than beam model under intact state. For damaged states, the natural frequencies captured from solid model show more sensitivity to damage severity than shell model and shell model performs similar to the beam model in distinguishing damage. The main contribution of this paper is to perform a comparison between three finite element models and experimental data as well as analytical solutions. The finite element results show a relatively well performance.
Resumo:
INTRODUCTION: The present study was designed to assess the occurrence of co-infection or cross-reaction in the serological techniques used for detecting the anti-Leishmania spp., -Babesia canis vogeli and -Ehrlichia canis antibodies in urban dogs from an area endemic to these parasites. METHODS: The serum samples from dogs were tested for the Babesia canis vogeli strain Belo Horizonte antigen and Ehrlichia canis strain São Paulo by immunofluorescence antibody test (IFAT) and by anti-Leishmania immunoglobulin G (IgG) antibody detection to assess Leishmania infection. We used the following four commercial kits for canine visceral leishmaniasis: ELISA, IFAT, Dual Path Platform (DPP) (Bio Manguinhos(r)/FIOCRUZ/MS) and a rK39 RDT (Kalazar Detect Canine Rapid Test; Inbios). RESULTS : Of 96 serum samples submitted to serological assays, 4 (4.2%) were positive for Leishmania as determined by ELISA; 12 (12.5%), by IFAT; 14 (14.6%) by rK39 RDT; and 20 (20.8%), by DPP. Antibodies against Ehrlichia and Babesia were detected in 23/96 (23.9%) and 30/96 (31.2%) samples, respectively. No significant association was identified between the results of tests for detecting Babesia or Ehrlichia and those for detecting Leishmania (p-value>0.05). CONCLUSIONS: In the present study, we demonstrated co-infection with Ehrlichia or Babesia and Leishmania in dogs from Minas Gerais (Brazil); we also found that the serological tests that were used did not cross-react.
Resumo:
Parasitic mites associated with spiders are spreading world-wide through the trade in tarantulas and other pet species. Ljunghia pulleinei Womersley, a mesostigmatic laelapid mite originally found in association with the mygalomorph spider Selenocosmia stirlingi Hogg (Theraphosidae) in Australia, is redescribed and illustrated on the basis of specimens from the African theraphosid spider Pterinochilus chordatus (Gersta¨cker) kept in captivity in the British Isles (Wales). The mite is known from older original descriptions of Womersley in 1956; the subsequent redescription of Domrow in 1975 seems to be questionable in conspecificity of treated specimens with the type material. Some inconsistencies in both descriptions are recognised here as intraspecific variability of the studied specimens. The genus Arachnyssus Ma, with species A. guangxiensis (type) and A. huwenae, is not considered to be a valid genus, and is included in synonymy with Ljunghia Oudemans. A new key to world species of the genus Ljunghia is provided.
Resumo:
The yrast level structure of Rn-215 has been studied by means of in-beam spectroscopy alpha-gamma-gamma coincidence techniques through the Pb-207(O-18,2 alpha 2n) reaction at 93 MeV bombarding energy, using the 8 pi GASP-ISIS spectrometer at Legnaro. New spectroscopic information has been obtained. The deduced low-lying level scheme of Rn-215 does not exhibit the alternating parity structure observed in the heavier known isotones Fr-216, Ra-217, Ac-218, and Th-219. From this result, the lightest nucleus showing evidence for octupole collectivity is Fr-216, defining the lowest-mass corner for this kind of phenomenon as N >= 129 and Z >= 87.
Resumo:
Die Nuklearmedizin ist ein modernes und effektives Werkzeug zur Erkennung und Behandlung von onkologischen Erkrankungen. Molekulare Bildgebung, die auf dem Einsatz von Radiopharmaka basiert, beinhaltet die Einzel-Photonen-Emissions-Tomographie (SPECT) und Positronenemissions¬tomographie (PET) und ermöglicht die nicht-invasive Visualisierung von Tumoren auf nano-und picomolarer Ebene.rnDerzeit werden viele neue Tracer für die genauere Lokalisierung von kleinen Tumoren und Metastasen eingeführt und hinsichtlich ihrer Eignung untersucht. Die meisten von ihnen sind Protein-basierte Biomoleküle, die die Natur selbst als Antigene für die Tumorzellen produziert. Dabei spielen Antikörper und Antikörper-Fragmente eine wichtige Rolle in der Tumor-Diagnostik und Behandlung. Die PET-Bildgebung mit Antikörpern und Antikörperfragmenten bezeichnet man als immuno-PET. Ein wichtiger Aspekt hierbei ist, dass entsprechende Radiopharmaka benötigt werden, deren Halbwertszeit mit der Halbwertszeit der Biomoleküle korreliert ist.rnIn neueren Arbeiten wird 90Nb als potenzieller Kandidat für die Anwendung in der immuno-PET vorgeschlagen. Seine Halbwertszeit von 14,6 Stunden ist geeignet für die Anwendung mit Antikörperfragmenten und einige intakten Antikörpern. 90Nb hat eine relativ hohen Anteil an Positronenemission von 53% und eine optimale Energie für die β+-Emission von 0,35 MeV, die sowohl eine hohe Qualität der Bildgebung als auch eine niedrige Aktivitätsmenge des Radionuklids ermöglicht.rnErsten grundlegende Untersuchungen zeigten: i) dass 90Nb in ausreichender Menge und Reinheit durch Protonen-Bombardierung des natürlichen Zirkonium Targets produziert, ii) aus dem Targetmaterial in entsprechender radiochemischer Reinheit isoliert und iii) zur Markierung des monoklonalen Antikörpers (Rituximab) verwendet werden kann und iv) dieser 90Nb-markierte mAb eine hohe in vitro Stabilität besitzt. Desweiteren wurde eine alternative und schnelle Abtrennungsmethode entwickelt, die es erlaubt 90Nb, mit einer geeigneten radiochemischen und radionuklidischen Reinheit für eine anschließende Markierung von Biomolekülen in einer Stunde zu aufzureinigen. Schließlich wurden erstmals 90Nb-markierte Biomolekülen in vivo untersucht. Desweiteren wurden auch Experimente durchgeführt, um den optimalen bifunktionellen Chelatbildner (BFC) für 90Niob zu finden. Mehrere BFC wurden hinsichtlich Komplexbildung mit NbV untersucht. Desferrioxamin (Df) erwies sich als geeignetster Chelator für 90Nb. Der monoklonale Antikörper Bevacizumab (Avastin®) wurde mit 90Nb markiert und eine Biodistributionsstudie und eine PET-Untersuchung durchgeführt. Alle diese Ergebnisse zeigten, dass 90Nb ein vielversprechendes Radionuklid für die Immuno-PET ist, welches sogar für weitere kommerzielle Anwendungen in der klinischen Routine geeignet zu sein scheint.rn
Resumo:
Patients with chronic pain disorders often show somatosensory disturbances that are considered to be functional. This paper aims at a more precise clinical description and at a documentation of functional neuroimaging correlates of this phenomenon. We examined 30 consecutive patients with unilaterally accentuated chronic pain not explained by persistent peripheral tissue damage and ipsilateral somatosensory disturbances including upper and lower extremities and trunk. The patients were assessed clinically and with conventional brain CT or MRI scan. In the last 11 patients functional neuroimaging was carried out (18-fluordeoxyglucose positron emission tomography=FDG-PET). Depressive symptoms were assessed with the Hamilton depression scale (HAMD-17) and pain intensity was rated with a visual analogue scale for pain (VAS). All patients suffered from mild to moderate depressive symptoms. All patients had experienced a prolonged antecedent phase of severe emotional distress; most of them remembered a "trigger episode of somatic pain" on the affected side. Somatosensory deficits were a replicable hyposensitivity to touch and heat perception of nondermatomal distribution. Conventional imaging procedures (brain CT or MRI scans) showed no structural changes. However, in 11 patients functional imaging with FDG-PET showed a significant hypometabolic pattern of changes in cortical and subcortical areas, mainly in the post-central gyrus, posterior insula, putamen, and anterior cingulate cortex. In summary, pain-related nondermatomal somatosensory deficits (NDSDs) are a phenomenon involving biological as well as psychosocial factors with replicable neuroperceptive clinical findings and a complex neurodysfunctional pattern in the FDG-PET.
Resumo:
PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.
Resumo:
Ion beam therapy is a valuable method for the treatment of deep-seated and radio-resistant tumors thanks to the favorable depth-dose distribution characterized by the Bragg peak. Hadrontherapy facilities take advantage of the specific ion range, resulting in a highly conformal dose in the target volume, while the dose in critical organs is reduced as compared to photon therapy. The necessity to monitor the delivery precision, i.e. the ion range, is unquestionable, thus different approaches have been investigated, such as the detection of prompt photons or annihilation photons of positron emitter nuclei created during the therapeutic treatment. Based on the measurement of the induced β+ activity, our group has developed various in-beam PET prototypes: the one under test is composed by two planar detector heads, each one consisting of four modules with a total active area of 10 × 10 cm2. A single detector module is made of a LYSO crystal matrix coupled to a position sensitive photomultiplier and is read-out by dedicated frontend electronics. A preliminary data taking was performed at the Italian National Centre for Oncological Hadron Therapy (CNAO, Pavia), using proton beams in the energy range of 93–112 MeV impinging on a plastic phantom. The measured activity profiles are presented and compared with the simulated ones based on the Monte Carlo FLUKA package.
Resumo:
"Materials Laboratory, Contract no. AF 33(616)-5426, Project no. 7360."
Resumo:
A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.
Resumo:
The failure of current strategies to provide an explanation for controversial findings on the pattern of pathophysiological changes in Alzheimer's Disease (AD) motivates the necessity to develop new integrative approaches based on multi-modal neuroimaging data that captures various aspects of disease pathology. Previous studies using [18F]fluorodeoxyglucose positron emission tomography (FDG-PET) and structural magnetic resonance imaging (sMRI) report controversial results about time-line, spatial extent and magnitude of glucose hypometabolism and atrophy in AD that depend on clinical and demographic characteristics of the studied populations. Here, we provide and validate at a group level a generative anatomical model of glucose hypo-metabolism and atrophy progression in AD based on FDG-PET and sMRI data of 80 patients and 79 healthy controls to describe expected age and symptom severity related changes in AD relative to a baseline provided by healthy aging. We demonstrate a high level of anatomical accuracy for both modalities yielding strongly age- and symptom-severity- dependant glucose hypometabolism in temporal, parietal and precuneal regions and a more extensive network of atrophy in hippocampal, temporal, parietal, occipital and posterior caudate regions. The model suggests greater and more consistent changes in FDG-PET compared to sMRI at earlier and the inversion of this pattern at more advanced AD stages. Our model describes, integrates and predicts characteristic patterns of AD related pathology, uncontaminated by normal age effects, derived from multi-modal data. It further provides an integrative explanation for findings suggesting a dissociation between early- and late-onset AD. The generative model offers a basis for further development of individualized biomarkers allowing accurate early diagnosis and treatment evaluation.
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center
Resumo:
Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.
Resumo:
A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.