983 resultados para implant prosthesis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

doi: 10.1111/j.1741-2358.2012.00636.x Hyperbaric oxygen therapy treatment for the fixation of implant prosthesis in oncology patients irradiated Objectives: This study aimed to present a clinical report of an irradiated oncologic patient who underwent hyperbaric oxygen therapy to be rehabilitated with implant-supported prosthesis. Materials and Methods: A 67-year-old man was admitted at Oral Oncology Center (FOA-UNESP) presenting a lesion on the mouth floor. After clinical evaluation, incisional biopsy and histopathological exam, a grade II squamous cell carcinoma was diagnosed. The patient was subjected to surgery to remove the lesion and partial glossectomy. Afterwards, the radiotherapy, in the left/right cervicofacial area of the supraclavicular fossa, was conducted. After 3 years of the surgery, the patient was submitted to hyperbaric oxygen therapy. Then, four implants were installed in patients mandible. Five months later, an upper conventional complete denture and lower full-arch implant-supported prosthesis were fabricated. Conclusion: The treatment resulted in several benefits such as improving his chewing efficiency, swallowing and speech, less denture trauma on the mucosa and improving his self-esteem.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Because of the widespread use of implant-supported restorations and that the success of this treatment depends on the passivity of the different component systems of implant-prosthesis, a literature review was performed to highlight issues related to passivity in framework of implant-supported fixed prosthesis. A search of English-language peer-review literature was completed using MEDLINE database (PubMed) focusing on acceptable levels of passivity, misfit classification, problems related to misfit, methods to evaluate misfit, general factors that affect the passivity, and the biologic tolerance in the presence of misfit. The information obtained in the present review suggested that even if it is hard to obtain an implant-supported prosthesis with complete passivity, the professional should use the technological resources to offer better conditions for their patients. An acceptable clinical level of passivity that does not cause any problem to the biologic, aesthetic, and functional parameters of the patient should be sought.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES To evaluate prosthetic parameters in the edentulous anterior maxilla for decision making between fixed and removable implant prosthesis using virtual planning software. MATERIAL AND METHODS CT- or DVT-scans of 43 patients (mean age 62 ± 8 years) with an edentulous maxilla were analyzed with the NobelGuide software. Implants (≥3.5 mm diameter, ≥10 mm length) were virtually placed in the optimal three-dimensional prosthetic position of all maxillary front teeth. Anatomical and prosthetic landmarks, including the cervical crown point (C-Point), the acrylic flange border (F-Point), and the implant-platform buccal-end (I-Point) were defined in each middle section to determine four measuring parameters: (1) acrylic flange height (FLHeight), (2) mucosal coverage (MucCov), (3) crown-Implant distance (CID) and (4) buccal prosthesis profile (ProsthProfile). Based on these parameters, all patients were assigned to one of three classes: (A) MucCov ≤ 0 mm and ProsthProfile≥45(0) allowing for fixed prosthesis, (B) MucCov = 0-5 mm and/or ProsthProfile = 30(0) -45(0) probably allowing for fixed prosthesis, and (C) MucCov ≥ 5 mm and/or ProsthProfile ≤ 30(0) where removable prosthesis is favorable. Statistical analyses included descriptive methods and non-parametric tests. RESULTS Mean values were for FLHeight 10.0 mm, MucCov 5.6 mm, CID 7.4 mm, and ProsthProfile 39.1(0) . Seventy percent of patients fulfilled class C criteria (removable), 21% class B (probably fixed), and 2% class A (fixed), while in 7% (three patients) bone volume was insufficient for implant planning. CONCLUSIONS The proposed classification and virtual planning procedure simplify the decision-making process regarding type of prosthesis and increase predictability of esthetic treatment outcomes. It was demonstrated that in the majority of cases, the space between the prosthetic crown and implant platform had to be filled with prosthetic materials.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

ObjectivesThe aim of this study was to evaluate the quality of life and satisfaction of patients wearing implant-supported fixed partial dentures.Materials &methodsA total of 106 patients were selected and submitted to clinical examination and collection of the demographic data for evaluation of the implant-supported fixed dentures conditions. All participants agreed to answer to the Oral Health Impact Profile (OHIP-EDENT) questionnaire and another questionnaire about satisfaction with the implant-supported prostheses. The patients were classified into the following three groups for statistical analysis: patients wearing splinted implant-supported prosthesis (E), patients wearing single implant-supported prosthesis (U), and patients wearing single implant-supported prosthesis associated with splinted prosthesis (E+U). Kruskal-Wallis test was used to compare the answers between the groups, and a logistic regression model was measured to verify the relation between variables of the patients and the questionaries'items.ResultsThere were significant differences among groups (P=0.006) for discomfort during surgery itself of the satisfaction questionnaire. The marital status, groups, and hygiene condition were significant mainly for physical pain item.ConclusionsIt was concluded that the patients presented high level of satisfaction and quality of life for the most of the items evaluated as well as the groups showed similar results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This report shows the resolution of a case study whose aim was promote the aesthetic and functional rehabilitation of upper left hemi-arch over endosseous and needle implant prostheses. To improve the position of the needle implants, we performed the bucco-palatal bending of needles splinting them with composite resin; we removed the screwed implant prosthesis in the regions of the premolars (24 and 25) and molar (26). The mini-abutments of the last two implants were replaced, and in the first premolar and canine, we used cemented abutments due to implant angulation having planned soldering because of implant size and contact with one needle implant that could interfere with intimate contact bone/implant damaging biomechanics. Pick-up impressions were performed with an open tray, using a retractor cord in the needle implants and respective transfer copings. Therefore, models were related on semi-adjustable articulator after a face-bow recording and interocclusal indexes. After working cast fabrication and try-in of infra-structures, these were adjusted and related into the articulator again. Then, after ceramic build-up, adjustments, finishing, and torque, chemically-activated resin cement was applied on units 21 to 24. At the end of the case, we concluded that a good aesthetic and functional rehabilitation depends on thorough knowledge of techniques for each clinical situation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osseointegrated implants have specific nature distinguish them from natural teeth making them more susceptible to the efforts generated by mastication. The absence of periodontal ligament, which absorbs the masticatory forces and allows the movement of the teeth interfere with the reception of occlusal loads and therefore the predictability of implants. In the boneimplant interface did not occur the phenomena of dissipation of impact, even the movement induced. Thus, during planning and installation of implant prosthesis, the type and characteristics of occlusal pattern adopted should be established with criteria to be no grounds for future failures. In this regard we highlight the occlusal overload generated by several reasons like the presence of premature contacts, interference during motion excursive, deleterious habits and inappropriate extensions on cantilevers. Thus, the objective is to provide a review of the literature regarding the importance of occlusion in oral rehabilitation with implants. Factors to be considered in establishing a favorable occlusion, consistent with prostheses on implants will be described

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.