923 resultados para impedance measurements


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The noseclip is conventionally used in lung function testing to prevent leakage via the nasal compartments. However, some subjects exhibit a velum-opening reflex which may affect results. We performed forced oscillation measurements at frequencies (8-256 Hz) that include the first antiresonance, comparing the noseclip with a cotton wool nose plug to eliminate upper airway contribution. Three sets of measurements were made in 18 adults: with and without noseclip, and with cotton wool. Velum opening during noseclip measurements was monitored using a nasal pressure transducer. A significantly greater proportion of subjects produced a characteristic distortion to the first antiresonance with the noseclip than with either no noseclip or with cotton wool. Distortion of the spectrum coincided with the transmission of oscillations into the nasal cavity. Thus, the noseclip cannot be used in high-frequency forced oscillation measurements because of the velum reflex. The cotton wool plug offers a simple alternative. This effect has unknown impact in other lung function tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gastro-oesophageal reflux disease (GERD) is a highly prevalent condition in Western countries leading to millions of outpatient visits per year. GERD symptoms including heartburn, regurgitation and chest pain are caused by reflux of gastric content in the oesophagus even in the absence of endoscopically visible mucosal lesions. Several procedures are used to identify gastro-oesophageal reflux, the clinically widely used are: conventional (catheter-based) pH monitoring, wireless oesophageal pH monitoring (Bravo), bilirubin monitoring (Bilitec), and combined multichannel intraluminal impedance-pH monitoring (MII-pH). Each technique has strengths and limitations of which clinicians and investigators should be aware when deciding which to choose in a particular patient. Important is the ability to quantify gastro-oesophageal reflux and evaluate the relationship between symptoms and reflux episodes. The present review summarises the technical aspects in performing and interpreting esophageal reflux monitoring procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An impedance-based midspan debonding identification method for RC beams strengthened with FRP strips is presented in this paper using piezoelectric ceramic (PZT) sensor?actuators. To reach this purpose, firstly, a two-dimensional electromechanical impedance model is proposed to predict the electrical admittance of the PZT transducer bonded to the FRP strips of an RC beam. Considering the impedance is measured in high frequencies, a spectral element model of the bonded-PZT?FRP strengthened beam is developed. This model, in conjunction with experimental measurements of PZT transducers, is used to present an updating methodology to quantitatively detect interfacial debonding of these kinds of structures. To improve the performance and accuracy of the detection algorithm in a challenging problem such as ours, the structural health monitoring approach is solved with an ensemble process based on particle of swarm. An adaptive mesh scheme has also been developed to increase the reliability in locating the area in which debonding initiates. Predictions carried out with experimental results have showed the effectiveness and potential of the proposed method to detect prematurely at its earliest stages a critical failure mode such as that due to midspan debonding of the FRP strip.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The electrochemical performance of carbon fibers (CF) and boron-doped diamond electrodes grown on carbon fiber substrate (BDD/CF) was studied. CF substrates were obtained from polyacrylonitrile precursor heat treated at two different temperatures of 1000 and 2000 degrees C to produce the desirable CF carbon graphitization index. This graphitization process influenced the CF conductivity and its chemical surface, also analyzed from X-ray photoelectron spectroscopy measurements. These three-dimensional CF structures allowed a high incorporation of diamond films compared to other carbon substrates such as glass carbon or HOPG. The electrochemical responses, from these four classes of electrodes, were evaluated focusing their application as electrical double-layer capacitors using cyclic voltammetry and impedance measurements. Cyclic voltammetry results revealed that the electrode formed from BDD grown on CF-2000 presented a typical capacitor behavior with the best rectangular shape, compared to those electrodes of CF or BDD/CF-1000. Furthermore, the BDD/CF-2000 electrode presented the lowest impedance, associated to its significant capacitance value of 1940 mu F/cm(2) taking into account the BDD films. This behavior was attributed to the strong dependence between diamond coating texture and the CF graphitization temperature. The largest surface area of BDD/CF-2000 was promoted by its singular film growth mechanism associated to the substrate chemical surface. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Electrical Impedance Tomography (EIT) is an imaging method which enables a volume conductivity map of a subject to be produced from multiple impedance measurements. It has the potential to become a portable non-invasive imaging technique of particular use in imaging brain function. Accurate numerical forward models may be used to improve image reconstruction but, until now, have employed an assumption of isotropic tissue conductivity. This may be expected to introduce inaccuracy, as body tissues, especially those such as white matter and the skull in head imaging, are highly anisotropic. The purpose of this study was, for the first time, to develop a method for incorporating anisotropy in a forward numerical model for EIT of the head and assess the resulting improvement in image quality in the case of linear reconstruction of one example of the human head. A realistic Finite Element Model (FEM) of an adult human head with segments for the scalp, skull, CSF, and brain was produced from a structural MRI. Anisotropy of the brain was estimated from a diffusion tensor-MRI of the same subject and anisotropy of the skull was approximated from the structural information. A method for incorporation of anisotropy in the forward model and its use in image reconstruction was produced. The improvement in reconstructed image quality was assessed in computer simulation by producing forward data, and then linear reconstruction using a sensitivity matrix approach. The mean boundary data difference between anisotropic and isotropic forward models for a reference conductivity was 50%. Use of the correct anisotropic FEM in image reconstruction, as opposed to an isotropic one, corrected an error of 24 mm in imaging a 10% conductivity decrease located in the hippocampus, improved localisation for conductivity changes deep in the brain and due to epilepsy by 4-17 mm, and, overall, led to a substantial improvement on image quality. This suggests that incorporation of anisotropy in numerical models used for image reconstruction is likely to improve EIT image quality.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Les récepteurs couplés aux protéines G (RCPGs) représentent la plus grande famille de cibles thérapeutiques pour le traitement d’une panoplie de pathologies humaines. Bien que plusieurs décennies de recherche aient permis de façonner nos connaissances sur ces protéines membranaires, notre compréhension des déterminants moléculaires de leur activité signalétique reste encore limitée. De ces domaines de recherche, une avancée récente a mis à jour un nouveau phénomène, appelé sélectivité fonctionnelle des ligands, qui a bouleversé les paradigmes décrivant leu fonctionnement de ces récepteurs. Ce concept émane d’observations montrant que l’activité pharmacologique de certains ligands n’est pas nécessairement conservée sur tout le répertoire signalétiques connu du récepteur et peu se restreindre à l'activation sélective d’un sous-groupe de voies de signalisation.Ce nouveau modèle pharmacologique de l'activation des RCPG ouvre de nouvelles possibilités pour la découverte de médicaments plus efficace et sûr, ciblant les RCPGs. En effet, il permet la conception de molécules modulant spécifiquement les voies signalétiques d’intérêt thérapeutique, sans engager les autres voies qui pourraient mener à des effets secondaires indésirables ou de la tolérance. Cette thèse décrit l'utilisation d'une nouvelle approche sans marquage, basée sur la mesure du changement l'impédance cellulaire. Par la mesure des changements cellulaires, comme la morphologie, l’adhésion et/ou la redistribution des macromolécules, cette approche permet de mesurer de façon simultanée l'activité de plusieurs voies de signalisation impliqués dans ces réponses. Utilisant le récepteur β2-adrénergique (β2AR) comme modèle, nous avons démontré que les variations dans l’impédance cellulaire étaient directement liées à l’activation de multiples voies de signalisation suite à la stimulation du récepteur par son ligand. L’agoniste type du β2AR, l’isoprotérénol, s’est avéré induire une réponse d’impédance dose-dépendante constituée, dans le temps, de plusieurs caractéristiques distinctes pouvant être bloquées de façon compétitive par l’antagoniste ICI118,551 Par l’utilisation d’inhibiteurs sélectifs, nous avons été en mesure de déterminer la contribution de plusieurs voies signalétiques canoniques, comme les voies dépendantes de Gs et Gi, la production d’AMPc et l’activation de ERK1/2, sur ces changements. De plus, la dissection de la réponse d’impédance a permis d’identifier une nouvelle voie de mobilisation du Ca2+ contribuant à la réponse globale des changements initiés par la stimulation du β2AR. Dans une autre étude, nous avons rapporté que la réponse calcique induite par le β2AR serait attribuable à une transactivation Gs-dépendant du récepteur purinergique P2Y11, lui-même couplé à la protéine Gq. La mesure d’impédance permettant de distinguer et de décrire une pléiade d’activités signalétiques, nous avons émis l’hypothèse que des ligands arborant des profils signalétiques différents généreraient des réponses d’impédance distinctes. Le criblage d’une librairie de ligands spécifiques au β2AR a révélé une grande variété de signatures d’impédance. Grâce au développement d’une approche computationnelle innovatrice, nous avons été en mesure de regrouper ces signatures en cinq classes de composés, un regroupement qui s’est avéré hautement corrélé avec le profil signalétique des différents ligands. Nous avons ensuite combiné le criblage de composés par impédance avec l’utilisation d’inhibiteurs sélectifs de voies signalétiques afin d’augmenter la résolution du regroupement. En évaluant l’impact d’une voie signalétique donnée sur la signature d’impédance, nous avons été en mesure de révéler une plus grande variété de textures parmi les ligands. De plus, cette méthode s’est avérée efficace pour prédire le profil signalétique d’une librairie de composés non caractérisés, ciblant le β2AR. Ces travaux ont mené à l’élaboration d’une méthode permettant d’exprimer visuellement la sélectivité fonctionnelle de ligands et ont révélé de nouvelles classes de composés pour ce récepteur. Ces nouvelles classes de composés ont ensuite été testées sur des cardiomyocytes humains, confirmant que les composés regroupés dans différentes classes produisent des effets distincts sur la contractilité de ces cellules. Globalement, ces travaux démontrent la pertinence de l’utilisation de l’impédance cellulaire pour une évaluation précise des différences fonctionnelles parmi les composés ciblant les RCPGs. En fournissant une représentation pluridimensionnelle de la signalisation émanant des RCPGs à l’aide d’un seul essai ne requérant pas de marquage, les signatures d’impédance représentent une stratégie simple et innovante pour l’évaluation de la fonctionnalité sélective des ligands. Cette méthode pourrait être d’une grande utilité dans le processus de découverte de nouveaux médicaments.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Impedance spectroscopy has been proven a powerful tool for reaching high sensitivity in sensor arrays made with nanostructured films in the so-called electronic tongue systems, whose distinguishing ability may be enhanced with sensing units capable of molecular recognition. In this study we show that for optimized sensors and bio-sensors the dielectric relaxation processes involved in impedance measurements should also be considered, in addition to an adequate choice of sensing materials. We used sensing units made from layer-by-layer (LbL) films with alternating layers of the polyeletrolytes, poly(allylamine) hydrochloride (PAH) and poly(vinyl sulfonate) (PVS), or LbL films of PAH alternated with layers of the enzyme phytase, all adsorbed on gold interdigitate electrodes. Surprisingly, the detection of phytic acid was as effective in the PVS/PAH sensing system as with the PAH/phytase system, in spite of the specific interactions of the latter. This was attributed to the dependence of the relaxation processes on nonspecific interactions such as electrostatic cross-linking and possibly on the distinct film architecture as the phytase layers were found to grow as columns on the LbL film, in contrast to the molecularly thin PAH/PVS films. Using projection techniques, we were able to detect phytic acid at the micromolar level with either of the sensing units in a data analysis procedure that allows for further optimization.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). METHODS: In a case-control study, we collected data from January to December 203 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of refluxes, baseline impedance, and swallow-induced peristaltic wave indices. RESULTS: FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. CONCLUSIONS: Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for identification of patients who respond to PPIs but would be classified as having FH based on conventional impedance-pH measurements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The function of the esophagus is transporting nutrients from the oropharyngeal cavity to the stomach. This is achieved by coordinated contractions and relaxation of the tubular esophagus and the upper and lower esophageal sphincter. Multichannel intraluminal impedance monitoring offers quantification of esophageal bolus transit and/or retention without the use of ionizing radiation. Combined with conventional or high-resolution manometry, impedance measurements complement the quantification of esophageal body contraction and sphincter relaxation, offering a more comprehensive evaluation of esophageal function. Further studies evaluating the utility of quantifying bolus transit will help clarify the role and position of impedance measurements.