174 resultados para humerus
Resumo:
To evaluate the outcomes in patients treated for humerus distal third fractures with MIPO technique and visualization of the radial nerve by an accessory approach, in those without radial palsy before surgery. The patients were treated with MIPO technique. The visualization and isolation of the radial nerve was done by an approach between the brachialis and the brachiorradialis, with an oblique incision, in the lateral side of the arm. MEPS was used to evaluate the elbow function. Seven patients were evaluated with a mean age of 29.8 years old. The average follow up was 29.85 months. The radial neuropraxis after surgery occurred in three patients. The sensorial recovery occurred after 3.16 months on average and also of the motor function, after 5.33 months on average, in all patients. We achieved fracture consolidation in all patients (M=4.22 months). The averages for flexion-extension and prono-supination were 112.85° and 145°, respectively. The MEPS average score was 86.42. There was no case of infection. This approach allowed excluding a radial nerve interposition on site of the fracture and/or under the plate, showing a high level of consolidation of the fracture and a good evolution of the range of movement of the elbow. Level of Evidence IV, Case Series.
Resumo:
A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.
Resumo:
Introduction: The use of bioabsorbable materials for orthopaedic useand traumatic fracture fixation in children has been poorly investigatedin the litterature and the effects on growing bones seem contradictory.The aim of the study is to compare the clinical and radiological resultsand evolution between bioabsorbable and traditional K-Wires for thetreatment of elbow epiphyseal fractures in children.Method: From jan. 2008 to Dec. 2009 21 children with similar fracturesand age were separated in two groups according to the way of fracturefixation: bioabsorbable K-Wire group and traditional K-Wire group.Follow-up was done at 3, 6 and 12 month post-operatively. Range ofmotion and elbow stability were measured for all patients. Theradiological evolution of the two groups were compared in term ofconsolidation, ossous resorption and radiolucencies. The clinicalresults were compared according to the Mayo Elbow Peformancescore. Controlateral elbow is compared with injured elbow in the twogroups.Results: In the bioabsorbable K-wire group, there were 10 children,including 5 girles and 5 boys with an average age of 9.5 years, rangingfrom 5 to 14 years. They were 7 external condylar fractures and3 epitrochlear fractures. In the traditional K-Wire group there were11 children, 2 girls and 9 boys with an average age of 7.6 years,ranging from 4 to 14 years. There were 10 external condylar fracturesand 1 epitrochlear fracture. At first follow up. The Mayo ElbowPerformance score was 93.8 (85-100 )for the bioabsorbable K-Wiregroup and 95.5 (85-100) for the traditional K-Wire group. In twochildren from the bioabsorbable K-Wire group there were transitoryradiolucencies along the wire tract on the x-ray, without clinicalmanifestation of it.We didn't see any premature closure of growingcartilage.Discussion: There is no significant differencies in term of clinical andradiological outcome between the two groups. The use ofbioabsorbable pins seems to be a good alternative to removabletraditional materials, avoiding a second operation.
Resumo:
The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.
Resumo:
Les fractures du condyle externe de l'enfant sont un traumatisme relativement fréquent qui survient le plus souvent chez l'enfant entre 5 et 15 ans. Elles sont classées en 3 grades : le grade 1 sans déplacement qui peuvent être traitées conservativement et les grades 2 (déplacées) et 3 (disloquées) qui nécessitent une prise en charge chirurgicale par réduction ouverte et embrochage. Le traitement traditionnel de ces fractures consistent en la mise en place de broches/vis métalliques qui doivent être retirées quelques semaines plus tard lors d'une seconde intervention. Depuis les années 90, des matériaux bio-résorbables à base d'acide polyglycoliques sont apparus en chirurgie orthopédique et traumatologique. En raison de la survenue de complications telles que réactions inflammatoires, formation de séromes ou ostéolyse, l'utilisation du matériel conventionnel a été préférée. Cependant, depuis quelques années, de nouveaux matériaux en acide polylactique sont apparus sur le marché. La période de résorption étant beaucoup plus lente, ces matériaux induisent des réactions beaucoup plus faibles, sans conséquences cliniques relevées jusqu'à présent. Chez l'adulte, de récentes études ont prouvés l'efficacité et l'absence d'effets secondaires liés à ces matériaux. Par contre, chez l'enfant, peu d'études à moyen terme ont été réalisées et l'impact sur l'os en croissance est peu connu, même si pour l'heure aucune conséquence clinique n'a été relevée. Dans le cadre de notre étude, nous avons comparé 2 groupes d'enfants traités pour des fractures du condyle externe du coude. Le premier groupe traité par du matériel conventionnel et le second par matériel résorbable. Les enfants ont tous étés suivis de manière très étroite durant la première année et la récupération clinique est similaire pour les 2 groupes. A 4 ans du traumatisme, les résultats fonctionnels sont identiques pour les 2 groupes et aucune complication liée au matériel résorbable n'a été mise en évidence. Par ailleurs, à 1 et 4 ans, les clichés radiologiques montrent l'absence de lésions liées au matériel résorbable. En conclusion, dans le cadre de notre travail nous avons pu montrer l'efficacité des matériaux résorbables dans la prise en charge des fractures du condyle externe du coude chez l'enfant. Ces matériaux permettent d'optimiser la prise en charge de ce type de fracture en prévenant un risque opératoire et anesthésique liés à une seconde intervention nécessaire au retrait du matériel d'ostéosynthèse conventionnel. Par ailleurs le coût lié à la prise en charge globale de ce type de fracture est moindre lors de l'utilisation de matériel résorbable.
Resumo:
A group of nine patients with a diaphyseal fracture of the humerus and treated with retrograde nailing were studied with a mean follow-up of 15.3 months. Six patients with a humeral fracture without neurological deficit showed a good shoulder and elbow mobility at the last visit. Three patients with neurological lesion preoperatively suffer from a diminished range of movement not related to the surgical procedure. During the operation and postoperatively we found no complication related to the implant and more precisely we could not find a iatrogenic fracture or nervous lesion except one intraoperative lesion of the radial nerve probably related to an important traction movement during reduction with complete remission. Consolidation has been achieved for all fractures but one. This patient suffers from a lesion of the brachial plexus with complete plegia of the arm and a vascular lesion. This patient had to be reoperated for an atrophic non-union by bone grafting and plate fixation. The retrograde nail is a good implant and must be considered in our treatment plans as much as conservative treatment or surgical treatment with plating, anterograde nailing or the use of an external fixator. Only then will we be able to give to the patient the most adapted treatment for his fracture.
Resumo:
The study aimed to compare the effects of intraosseous infusion of lactated Ringer's and 0.9% sodium chloride solutions on the electrolytes and acid-base balance in pigeons submitted to humerus osteosynthesis. Eighteen pigeons were undergoing to isoflurane anesthesia by an avalvular circuit system. They were randomly assigned into two groups (n=9) receiving lactated Ringer's solution (LR) or 0.9% sodium chloride (SC), in a continuous infusion rate of 20mL/kg/h, by using an intraosseous catheter into the tibiotarsus during 60-minute anesthetic procedure. Heart rate (HR), and respiratory rate (RR) were measured every 10 min. Venous blood samples were collected at 0, 30 and 60 minutes to analyze blood pH, PvCO2, HCO3 -, Na+ and K+. Blood gases and electrolytes showed respiratory acidosis in both groups during induction, under physical restraint. This acidosis was evidenced by a decrease of pH since 0 min, associated with a compensatory response, observed by increasing of HCO3 - concentration, at 30 and 60 min. It was not observed any changes on Na+ and K+ serum concentrations. According to the results, there is no reason for choosing one of the two solutions, and it could be concluded that both fluid therapy solutions do not promote any impact on acid-base balance and electrolyte concentrations in pigeons submitted to humerus osteosynthesis.
Resumo:
The expression of components present in the cartilaginous extracellular matrix is related to development, gender, and genotype, as well as to the biomechanical properties of each type of cartilage. In the present study, we analyzed small proteoglycans and glycosaminoglycans present in different cartilages of the chicken wing after extraction with guanidine hydrochloride or papain. Quantitative analysis of glycosaminoglycans showed a larger amount in humeral cartilage (around 200 mg/g tissue) than in articular cartilage of the radius and ulna, with 138 and 80 mg/g tissue, respectively. Non-collagenous proteins isolated were predominantly from cartilage in the proximal regions of the humerus and radius. D4 fractions obtained by ultracentrifugation were separated by DEAE-Sephacel and Octyl-Sepharose chromatography and analyzed by SDS-PAGE. Two bands of 57 and 70-90 kDa were observed for all samples treated with ß-mercaptoethanol. Immunoblotting of these proteins was positive for the small proteoglycans fibromodulin and decorin, respectively. Apparently, the 57-kDa protein is present in macromolecular complexes of 160 and 200 kDa. Chondroitin sulfate was detected in all regions. HPLC analysis of the products formed by chondroitinase AC and ABC digestion mainly revealed ß-D-glucuronic acid and N-acetyl ß-D-galactosamine residues. The 4-sulfation/6-sulfation ratio was close to 3, except for the proximal cartilage of the radius (2.5). These results suggest functional differences between the scapula-humerus, humerus-ulna, and humerus-radius joints of the chicken wing. This study contributes to the understanding of the physiology of cartilage and joints of birds under different types of mechanical stress.
Resumo:
Pre-publication drafts are reproduced with permission and copyright © 2013 of the Journal of Orthopaedic Trauma [Mutch J, Rouleau DM, Laflamme GY, Hagemeister N. Accurate Measurement of Greater Tuberosity Displacement without Computed Tomography: Validation of a method on Plain Radiography to guide Surgical Treatment. J Orthop Trauma. 2013 Nov 21: Epub ahead of print.] and copyright © 2014 of the British Editorial Society of Bone and Joint Surgery [Mutch JAJ, Laflamme GY, Hagemeister N, Cikes A, Rouleau DM. A new morphologic classification for greater tuberosity fractures of the proximal humerus: validation and clinical Implications. Bone Joint J 2014;96-B:In press.]
Resumo:
Photograph of an adult humerus bone.
Resumo:
A giant anteater (Myrmecophaga tridactyla) was found with closed comminuted fractures on the fight radius and ulna and left humerus he duration of which was unknown. The animal was unable to use either of he thoracic limbs. The fractures were stabilized with 3.5-mm titanium plates and a commercially available mixture of micro lyophilized bovine cortical osseous and bovine BMP (Gen-tech(R), Baumer, Brazil) was implanted into the fractures sites. Postoperative radiographic evaluations were performed every 30 days and after four months. Bone healing was observed in all of he fractures. The animal was able to be reintroduced into its natural habitat. From his case we conclude that despite he low metabolic fate of the giant anteater, which is an inherent characteristic of this species, he treatment of radius, ulna and humerus fractures by means of plates and screws, associated with BMP on the Myrmecophaga tridactyla, was a success.
Resumo:
Proximal humerus fractures (pHF) are common. In this retrospective study intra-operative and postoperative data and complications of patients stabilized with conventional semirigid techniques (pins, n=30; helix wire, n=19) or a novel semirigid technique, the intramedullary claw (IMC, n=82) were compared. The type and frequency of postoperative complications differed between the groups (p<0.001). The IMC is a novel semirigid technique to stabilize pHF and seems to result in fewer complications than pins or helix wire. The frequency and relevance of a loss of repositioning in patients after IMC implantation need to be elucidated in long-term studies.
Resumo:
Nonunions of pediatric subtrochanteric femur fractures are exceedingly rare and have to date not been reported in the literature. We present the case of an 11-year-old boy who developed such a nonunion after open reduction internal fixation using a pediatric locked proximal femur plate. Using an adult proximal humerus locking plate, adequate proximal fixation of the nonunion was obtained. Furthermore, previously placed distal screw holes were safely bridged and the biomechanical environment around the nonunion site improved. Uneventful healing was possible with the use of adjuvant bone grafting. No short- or midterm complications occurred. Although other implants can certainly be adapted to a use different than that of its original design, the present case suggests that adult proximal humerus locking plates may be a safe option for revision surgery of the proximal pediatric femur.
Resumo:
We present a case of a pathologic humerus fracture in a patient with the initial diagnosis of Gaucher's disease, which is the most frequent form of lipidosis transmitted as an autosomal recessive trait. It often results in orthopaedic complications with pain, osteonecrosis, fractures and joint infractions. If there is cause for suspicion, beta-glucocerebrosidase in white blood cells should be measured because of the important consequences for treatment. Therapy with a modified enzyme is effective in managing the disease.