887 resultados para hip muscles
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: To study the effect of additional strengthening of hip abductor and lateral rotator muscles in a strengthening quadriceps exercise rehabilitation programme for patients with the patellofemoral pain syndrome. Design: Randomized controlled pilot trial. Setting: Clinical setting with home programme. Participants: Fourteen patients with patellofemoral pain syndrome. Intervention: The subjects were randomly assigned to the intervention group (strengthening of quadriceps plus strengthening of hip abductor and lateral rotator muscles) or to the control group (strengthening of quadriceps). Both groups participated in a six-week home exercise protocol. Main outcome measures: The perceived pain symptoms, isokinetic eccentric knee extensor, hip abductor and lateral rotator torques and the gluteus medius electromyographic activity were assessed before and after treatment. Parametric and non-parametric tests were used to compare the groups before and after treatment with alpha = 0.05. Results: Only the intervention group improved perceived pain symptoms during functional activities (P=0.02-0.04) and also increased their gluteus medius electromyographic activity during isometric voluntary contraction (P=0.03), Eccentric knee extensors torque increased in both groups (P=0.04 and P=0.02). There was no statistically significant difference in the hip muscles torque in either group. Conclusion: Supplementation of strengthening of hip abductor and lateral rotator muscles in a strengthening quadriceps exercise programme provided additional benefits with respect to the perceived pain symptoms during functional activities in patients with patellofemoral pain syndrome after six weeks of treatment.
Resumo:
Queiroz BC, Cagliari MF, Amorim CF, Sacco IC. Muscle activation during four Pilates core stability exercises in quadruped position. Arch Phys Med Rehabil 2010;91: 86-92. Objective: To compare the activity of stabilizing trunk and hip muscles in 4 variations of Pilates stabilizing exercises in the quadruped position. Design: Repeated-measures descriptive study. Setting: A biomechanics laboratory at a university school of medicine. Participants: Healthy subjects (N=19; mean age +/- SD, 31 +/- 5y; mean weight +/- SD, 60 +/- 11 kg; mean height +/- SD, 166 +/- 9cm) experienced in Pilates routines. Interventions: Surface electromyographic signals of iliocostalis, multifidus, gluteus maximus, rectus abdominis, and external and internal oblique muscles were recorded in 4 knee stretch exercises: retroverted pelvis with flexed trunk; anteverted pelvis with extended trunk; neutral pelvis with inclined trunk; and neutral pelvis with trunk parallel to the ground. Main Outcome Measures: Root mean square values of each muscle and exercise in both phases of hip extension and flexion, normalized by the maximal voluntary isometric contraction. Results: The retroverted pelvis with flexed trunk position led to significantly increased external oblique and gluteus maximus muscle activation. The anteverted pelvis with trunk extension significantly increased multifidus muscle activity. The neutral pelvis position led to significantly lower activity of all muscles. Rectus abdominis muscle activation to maintain body posture was similar in all exercises and was not influenced by position of the pelvis and trunk. Conclusions: Variations in the pelvic and trunk positions in the knee stretch exercises change the activation pattern of the multifidus, gluteus maximus, rectus abdominis, and oblique muscles. The lower level of activation of the rectus abdominis muscle suggests that pelvic stability is maintained in the 4 exercise positions.
Resumo:
Objective: To investigate the influence of age and preparation level on postural muscle activation and step completion time during a rapid step task. Design: Postural muscle onset times (EMG) and ground reaction forces were recorded from healthy young (n = 20, age 21 +/- 3 years) and older (n = 25, age 71 +/- 5 years) female adults during a choice reaction-time stepping paradigm. Main outcome measures: Onset times of six trunk and hip muscles, reaction time and components of the step (weight shift time, step time and task time) were recorded. Results: Muscle activation was delayed and movement time was lengthened in both young and older adults when poorly prepared for a stepping task. While reduced preparation did not influence older adults to a greater extent than young adults, the slowest step response and completion time was evident in older adults when poorly prepared to move. Conclusions: A late postural response when poorly prepared to move may be a contributing factor to an increased risk of overbalancing in older adults. Future assessment of and intervention to improve postural stability in older adults should be expanded to incorporate tasks performed at various levels of preparation.
Resumo:
The Patellofemoral pain syndrome is defined as a fore or retro patellar pain and it has multifactorial etiology, where the bad patellar alignment is the most acceptable hypothesis. However proximal factors to the knee, as the debility of the muscles of the hip, have been demonstrated as a contributing factor to the appearing of that syndrome. Purpose: To evaluate if exists a relation between the hip muscles performance and the development of the SDPF. Methods: Thirty women took part in this study. They were divided in two groups; a control group (fifteen asymptomatic subjects) and an experimental group (fifteen subjects with the diagnosis of SDPF). The muscle performance was evaluated in an isokinetic dynamometer, where it was verified the peak torque (PT), PT to body weight, PT time and the agonist/antagonist relation. It was also analyzed the electromyographic activity of the middle gluteus. The data was analyzed by the not paired t test at a significance level of 5%. Results:. Didn t have significant difference to the PT of the abductor muscles (p = 0,46) and lateral rotators of the hip (p = 0,17) between groups. Also didn t have significant difference to the PT values by the body weight, to these muscle groups either (p = 0,10 e p = 0,11, respectively). Didn t have significant difference between the amplitude of the signal (p = 0,05) and the onset of medium gluteus (p = 0,25) between the groups. Conclusion: In the experimental conditions realized, the study didn t demonstrate a relation between performance the hip muscles behavior and the development of the SDPF
Resumo:
Queiroz BC, Cagliari MF, Amorim CF, Sacco IC. Muscle activation during four Pilates core stability exercises in quadruped position. Arch Phys Med Rehabil 2010;91: 86-92.Objective: To compare the activity of stabilizing trunk and hip muscles in 4 variations of Pilates stabilizing exercises in the quadruped position.Design: Repeated-measures descriptive study.Setting: A biomechanics laboratory at a university school of medicine.Participants: Healthy subjects (N=19; mean age +/- SD, 31 +/- 5y; mean weight +/- SD, 60 +/- 11 kg; mean height +/- SD, 166 +/- 9cm) experienced in Pilates routines.Interventions: Surface electromyographic signals of iliocostalis, multifidus, gluteus maximus, rectus abdominis, and external and internal oblique muscles were recorded in 4 knee stretch exercises: retroverted pelvis with flexed trunk; anteverted pelvis with extended trunk; neutral pelvis with inclined trunk; and neutral pelvis with trunk parallel to the ground.Main Outcome Measures: Root mean square values of each muscle and exercise in both phases of hip extension and flexion, normalized by the maximal voluntary isometric contraction.Results: The retroverted pelvis with flexed trunk position led to significantly increased external oblique and gluteus maximus muscle activation. The anteverted pelvis with trunk extension significantly increased multifidus muscle activity. The neutral pelvis position led to significantly lower activity of all muscles. Rectus abdominis muscle activation to maintain body posture was similar in all exercises and was not influenced by position of the pelvis and trunk.Conclusions: Variations in the pelvic and trunk positions in the knee stretch exercises change the activation pattern of the multifidus, gluteus maximus, rectus abdominis, and oblique muscles. The lower level of activation of the rectus abdominis muscle suggests that pelvic stability is maintained in the 4 exercise positions.
Resumo:
INTRODUÇÃO: A fisioterapia na fase I da reabilitação cardiovascular (FTCV) pode ser iniciada de 12 a 24 horas após o infarto agudo do miocárdio (IAM), no entanto, é comum o repouso prolongado no leito em razão do receio de instabilização do paciente. OBJETIVOS: Avaliar as respostas autonômicas e hemodinâmicas de pacientes pós-IAM submetidos ao primeiro dia de protocolo de FTCV fase I, bem como sua segurança. MATERIAIS E MÉTODOS: Foram estudados 51 pacientes com primeiro IAM não complicado, 55 ± 11 anos, 76% homens. Foram submetidos ao primeiro dia do protocolo de FTCV fase I, em média 24 horas pós-IAM. A frequência cardíaca (FC) instantânea e os intervalos R-R do ECG foram captados pelo monitor de FC (Polar®S810i) e a pressão arterial (PA) aferida pelo método auscultatório. A variabilidade da FC foi analisada nos domínios do tempo (RMSSD e RMSM dos iR-R em ms) e da frequência. A densidade espectral de potência foi expressa em unidades absolutas (ms²/Hz) e normalizada (un) para as bandas de baixa (BF) e alta frequência (AF) e pela razão BF/AF. RESULTADOS: O índice RMSSD, a AF e a AFun apresentaram redução na execução dos exercícios em relação ao repouso pré e pós-exercício (p < 0,05), a BFun e a razão BF/AF aumentaram (p < 0,05). A FC e a PA sistólica apresentaram aumento durante a execução dos exercícios em relação ao repouso (p < 0,05). Não foi observado qualquer sinal e/ou sintoma de intolerância ao esforço. CONCLUSÕES: O exercício realizado foi eficaz, pois promoveu alterações hemodinâmicas e na modulação autonômica nesses pacientes, sem ocasionar qualquer intercorrência clínica.
Resumo:
Study Design. Cross-sectional study of electromyographic onsets of trunk and hip muscles in subjects with a clinical diagnosis of sacroiliac joint pain and matched control subjects. Objectives. To determine whether muscle activation of the supporting leg was different between control subjects and subjects with sacroiliac joint pain during hip flexion in standing. Background. Activation of the trunk and gluteal muscles stabilize the pelvis for load transference; however, the temporal pattern of muscle activation and the effect of pelvic pain on temporal parameters has not been investigated. Methods. Fourteen men with a clinical diagnosis of sacroiliac joint pain and healthy age-matched control subjects were studied. Surface electromyographic activity was recorded from seven trunk and hip muscles of the supporting leg during hip flexion in standing. Onset of muscle activity relative to initiation of the task was compared between groups and between limbs. Results. The onset of obliquus internus abdominis (OI) and multifidus occurred before initiation of weight transfer in the control subjects. the onset of obliquus internus abdominis, multifidus, and gluteus maximus was delayed on the symptomatic side in subjects with sacroiliac joint pain compared with control subjects, and the onset of biceps femoris electromyographic activity was earlier. IN addition, electromyographic onsets were different between the symptomatic and asymptomatic sides in subjects with sacroiliac joint pain. Conclusions. The delayed onset of obliquus internus abdominis, multifidus, and gluteus maximus electromyographic activity of the supporting leg during hip flexion, in subjects with sacroiliac joint pain. suggests an alteration in the strategy for lumbopelvic stabilization that may disrupt load transference through the pelvis.
Resumo:
Background and Purpose Previous research regarding the symmetry of trans-tibial amputees has examined weight distribution and various gait parameters between prosthetic and sound limbs. However, to date, no known research has determined if asymmetry is present in the strength of the hip abductor muscles or if correlations exist between these categories of symmetry. The purpose of the present study was, therefore, to document asymmetry present in stance, strength and gait measures, and to determine the relationship between these variables. Method Twenty-three elderly, unilateral trans-tibial amputees stood on two adjacent forceplates whilst the weight distribution and standard deviation (SD) of the anterior-posterior and the medio-lateral centre of pressure excursion (COPE) under each limb was recorded during four 40 s trials: quiet stance (QS), with eyes open and eyes closed; and even stance (ES), with eyes open and eyes closed. Gait measures (velocity, cadence, step and stride lengths, stance:swing ratio and period of double support) over 10 m of fast, yet safe walking and measures of the strength of hip abductor muscles were also obtained by use of a stride analyser and a dynamometer, respectively. Results No significant differences were found between QS and ES measures. However, significantly more weight was taken on the sound limb than on the amputated limb. Notably, more anterior-posterior movement occurred under the sound limb than the amputated limb, with this becoming more apparent with the eyes closed. Movement in the medio-lateral direction was found to be the same between sides. No differences in muscle strength or gait measures between limbs were demonstrated. However. strong hip abductor muscles were correlated with increased weight-bearing on the amputated limb, improved gait parameters and reduced medio-lateral COPE under the amputated limb. Conclusions This research confirms the asymmetrical nature of amputee stance and demonstrates symmetry of strength and gait measures between limbs. The correlations between hip abductor muscle strength, weight distribution and gait measures illustrates the importance of pre- and postoperative training of these muscles. Copyright © 2002 Whurr Publishers Ltd.
Resumo:
Background and Purpose. Activity of the trunk muscles is essential for maintaining stability of the lumbar spine because of the unstable structure of that portion of the spine. A model involving evaluation of the response of the lumbar multifidus and abdominal muscles to leg movement was developed to evaluate this function. Subjects. To examine this function in healthy persons, 9 male and 6 female subjects (mean age = 20.6 years, SD = 2.3) with no history of low back pain were studied. Methods. Fine-wire and surface electromyography electrodes were used to record the activity of selected trunk muscles and the prime movers for hip flexion, abduction, and extension during hip movements in each of these directions. Results. Trunk muscle activity occurring prior to activity of the prime mover of the limb was associated with hip movement in each direction. The transversus abdominis (TrA) muscle was invariably the first muscle that was active. Although reaction time for the TrA and oblique abdominal muscles was consistent across movement directions, reaction time for the rectus abdominis and multifidus muscles varied with the direction of limb movement. Conclusion and Discussion. Results suggest that the central nervous st stem deals with stabilization of the spine by contraction of the abdominal and multifidus muscles in anticipation of reactive forces produced by limb movement. The TrA and oblique abdominal muscles appear to contribute to a function not related to the direction of these forces.
Resumo:
Objective: To determine the relationships between eccentric hip and knee torques, symptom severity and functional capacity in females with patellofemoral pain syndrome (PFPS). Design: Within-subject correlational study. Setting: University biomechanics laboratory. Participants: 10 females diagnosed with PFPS. Main outcome measures: Eccentric strength of the hip abductors and lateral rotators, and knee extensors were assessed using an isokinetic dynamometer. A 10-cm visual analog scale was used to determine usual knee pain in the last week. The Anterior Knee Pain Scale (AKPS) was used to determine the functional capacity of the patients. Results: The study found that the greater the eccentric knee extensor and hip lateral rotator torques, the higher the functional capacity of the patients (p = 0.02, r = 0.72; p = 0.02, r = 0.72). It was also shown that the greater hip lateral rotator torque, the less the usual pain reported in the last week (p = 0.004, r = -0.84). Despite the lack of statistical significance (p = 0.11), it was also found a modest negative relationship between the eccentric knee extensor torque and the usual pain reported in the last week (r = -0.56) that was considered clinically meaningful (d = 1.4). Conclusions: This study showed that eccentric knee extensor and hip lateral rotator torques were associated with functional capacity and pain level in females with PFPS. Further investigations should be carried out to verify the effects of an intervention program focused on the eccentric action of these muscles with respect to the symptoms in patients with PFPS. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The success of artificial prosthetic replacements depends on the fixation of the artificial prosthetic component after being implanted in the thighbone. The materials for fixation are subject to mechanical stresses, which originate permanent deformations, incipient cracks and even fatigue fractures. This work shows the possibility of monitoring the mechanical stress over time in prosthesis. In this way, highly sensitive silicon thin-film piezoresistive sensors were developed attached to prosthesis and their results compared with commercial strain gauge sensors. Mechanical stress-strain experiments were performed in compressive mode, during 10,000 cycles. Experimental data was acquired at mechanical vibration frequencies of 0.5 Hz, 1 Hz and 5 Hz, and sent to a computer by means of a wireless link. The results show that there is a decrease in sensitivity of the thin-film silicon piezoresistive sensors when they are attached to the prosthesis, but this decrease does not compromise its monitoring performance. The sensitivity, compared to that of commercial strain gauges, is much larger due to their higher gauge factors (-23.5), when compared to the GFs of commercial sensors (2).
Resumo:
Au cours des deux dernières décennies, la technique d'imagerie arthro-scanner a bénéficié de nombreux progrès technologiques et représente aujourd'hui une excellente alternative à l'imagerie par résonance magnétique (IRM) et / ou arthro-IRM dans l'évaluation des pathologies de la hanche. Cependant, elle reste limitée par l'exposition aux rayonnements ionisants importante. Les techniques de reconstruction itérative (IR) ont récemment été mis en oeuvre avec succès en imagerie ; la littérature montre que l'utilisation ces dernières contribue à réduire la dose d'environ 40 à 55%, comparativement aux protocoles courants utilisant la rétroprojection filtrée (FBP), en scanner de rachis. A notre connaissance, l'utilisation de techniques IR en arthro-scanner de hanche n'a pas été évaluée jusqu'à présent. Le but de notre étude était d'évaluer l'impact de la technique ASIR (GE Healthcare) sur la qualité de l'image objective et subjective en arthro-scanner de hanche, et d'évaluer son potentiel en terme de réduction de dose. Pour cela, trente sept patients examinés par arthro-scanner de hanche ont été randomisés en trois groupes : dose standard (CTDIvol = 38,4 mGy) et deux groupes de dose réduite (CTDIvol = 24,6 ou 15,4 mGy). Les images ont été reconstruites en rétroprojection filtrée (FBP) puis en appliquant différents pourcentages croissants d'ASIR (30, 50, 70 et 90%). Le bruit et le rapport contraste sur bruit (CNR) ont été mesurés. Deux radiologues spécialisés en imagerie musculo-squelettique ont évalué de manière indépendante la qualité de l'image au niveau de plusieurs structures anatomiques en utilisant une échelle de quatre grades. Ils ont également évalué les lésions labrales et du cartilage articulaire. Les résultats révèlent que le bruit augmente (p = 0,0009) et le CNR diminue (p = 0,001) de manière significative lorsque la dose diminue. A l'inverse, le bruit diminue (p = 0,0001) et le contraste sur bruit augmente (p < 0,003) de manière significative lorsque le pourcentage d'ASIR augmente ; on trouve également une augmentation significative des scores de la qualité de l'image pour le labrum, le cartilage, l'os sous-chondral, la qualité de l'image globale (au delà de ASIR 50%), ainsi que le bruit (p < 0,04), et une réduction significative pour l'os trabuculaire et les muscles (p < 0,03). Indépendamment du niveau de dose, il n'y a pas de différence significative pour la détection et la caractérisation des lésions labrales (n=24, p = 1) et des lésions cartilagineuses (n=40, p > 0,89) en fonction du pourcentage d'ASIR. Notre travail a permis de montrer que l'utilisation de plus de 50% d'ASIR permet de reduire de manière significative la dose d'irradiation reçue par le patient lors d'un arthro-scanner de hanche tout en maintenant une qualité d'image diagnostique comparable par rapport à un protocole de dose standard utilisant la rétroprojection filtrée.
Resumo:
OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.