949 resultados para high-speed cutting


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, two ideal formation models of serrated chips, the symmetric formation model and the unilateral right-angle formation model, have been established for the first time. Based on the ideal models and related adiabatic shear theory of serrated chip formation, the theoretical relationship among average tooth pitch, average tooth height and chip thickness are obtained. Further, the theoretical relation of the passivation coefficient of chip's sawtooth and the chip thickness compression ratio is deduced as well. The comparison between these theoretical prediction curves and experimental data shows good agreement, which well validates the robustness of the ideal chip formation models and the correctness of the theoretical deducing analysis. The proposed ideal models may have provided a simple but effective theoretical basis for succeeding research on serrated chip morphology. Finally, the influences of most principal cutting factors on serrated chip formation are discussed on the basis of a series of finite element simulation results for practical advices of controlling serrated chips in engineering application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents specific cutting energy measurements as a function of the cutting speed and tool cutting edge geometry. The experimental work was carried out on a vertical CNC machining center with 7,500 rpm spindle rotation and 7.5 kW power. Hardened steels ASTM H13 (50 HRC) were machined at conventional cutting speed and high-speed cutting (HSC). TiN coated carbides with seven different geometries of chip breaker were applied on dry tests. A special milling tool holder with only one cutting edge was developed and the machining forces needed to calculate the specific cutting energy were recorded using a piezoelectric 4-component dynamometer. Workpiece roughness and chip formation process were also evaluated. The results showed that the specific cutting energy decreased 15.5% when cutting speed was increased up to 700%. An increase of 1 °in tool chip breaker chamfer angle lead to a reduction in the specific cutting energy about 13.7% and 28.6% when machining at HSC and conventional cutting speed respectively. Furthermore the workpiece roughness values evaluated in all test conditions were very low, closer to those of typical grinding operations (∼0.20 μm). Probable adiabatic shear occurred on chip segmentation at HSC Copyright © 2007 by ABCM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Si3N4 tools were coated with a thin diamond film using a Hot-Filament Chemical Vapour Deposition (HFCVD) reactor, in order to machining a grey cast iron. Wear behaviour of these tools in high speed machining was the main subject of this work. Turning tests were performed with a combination of cutting speeds of 500, 700 and 900 m min−1, and feed rates of 0.1, 0.25 and 0.4 mm rot−1, remaining constant the depth of cut of 1 mm. In order to evaluate the tool behaviour during the turning tests, cutting forces were analyzed being verified a significant increase with feed rate. Diamond film removal occurred for the most severe set of cutting parameters. It was also observed the adhesion of iron and manganese from the workpiece to the tool. Tests were performed on a CNC lathe provided with a 3-axis dynamometer. Results were collected and registered by homemade software. Tool wear analysis was achieved by a Scanning Electron Microscope (SEM) provided with an X-ray Energy Dispersive Spectroscopy (EDS) system. Surface analysis was performed by a profilometer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of a machined finish plays a major role in the performance of milling operations, good surface quality can significantly improve fatigue strength, corrosion resistance, or creep behaviour as well as surface friction. In this study, the effect of cutting parameters and cutting fluid pressure on the quality measurement of the surface of the crest for threads milled during high speed milling operations has been scrutinised. Cutting fluid pressure, feed rate and spindle speed were the input parameters whilst minimising surface roughness on the crest of the thread was the target. The experimental study was designed using the Taguchi L32 array. Analysing and modelling the effective parameters were carried out using both a multi-layer perceptron (MLP) and radial basis function (RBF) artificial neural networks (ANNs). These were shown to be highly adept for such tasks. In this paper, the analysis of surface roughness at the crest of the thread in high speed thread milling using a high accuracy optical profile-meter is an original contribution to the literature. The experimental results demonstrated that the surface quality in the crest of the thread was improved by increasing cutting speed, feed rate ranging 0.41-0.45 m/min and cutting fluid pressure ranging 2-3.5 bars. These outcomes characterised the ANN as a promising application for surface profile modelling in precision machining.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the generation of pulsed, high-speed liquid jets using the cumulation method. This work mainly includes (1) the design of the nozzle assembly, (2) the measurement of the jet velocity and (3) flow visualization of the injection sequences. The cumulation method can be briefly described as the liquid being accelerated first by the impact of a moving projectile and then further after it enters a converging section. The experimental results show that the cumulation method is useful in obtaining a liquid jet with high velocity. The flow visualization shows the roles of the Rayleigh-Taylor and Kelvin-Helmholtz instabilities in the breakup of the liquid depend on the jet diameter and the downstream distance. When the liquid jet front is far downstream from the nozzle exit, the jet is decelerated by air drag. Meanwhile, large coherent vortex structures are formed surrounding the jet. The liquid will break up totally by the action of these vortices. Experimental results showing the effect of the liquid volume on the jet velocity are also included in this paper. Finally, a method for measuring the jet velocity by cutting two carbon rods is examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Development of a high-speed and high-yield water-powered fish evisceration system (FES) to efficiently preprocess small fish and bycatch for producing minced fish meat is described. The concept of the system is propelling fish in a stream of water through an arrangement of cutting blades and brushes. Eviscerated fish are separated from the viscera and water stream in a dual screen rotary sieve. The FES processed head off fish, weighing 170–500 g, at the rate of 300 fish/min when used with an automatic heading machine. Yields of mince produced from walleye pollock, Theragra chalcogramma; and Pacific whiting, Merluccius productus; processed by the FES ranged between 43% and 58%. The maximum yield of minced muscle from fish weighing over 250 g was 52%, and the yield of 250 g was 58%. Test results indicated that surimi made from minced meat recovered from fish processed with the FES was comparable in quality to commercial grade surimi from conventional systems. Redesigned for commercial operation in the Faeroe Islands (Denmark), the system effectively processed North Atlantic blue whiting, Micromesistius poutassou, with an average weight of 110 g at a constant rate of 500–600 fish/min, producing deboned mince feeding a surimi processing line at a rate of 2.0 t/h. Yields of mince ranged from 55% to 63% from round fish. Surimi made from the blue whiting mince meat produced by the FES was comparable to surimi commercially produced from blue whiting by Norway and France and sold into European markets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. Cavity and tooth preparations generate heat because the use of rotary cutting instruments on dental tissues creates friction. Dental pulps cannot survive temperature increases greater than 5.5degreesC.Purpose. This study evaluated the efficiency of 3 different water flows for 2 different tooth preparation techniques to determine which are safe for use.Material and methods. Thermocouples were placed in the pulpal chambers of 30 bovine teeth, and 1 of 2 tooth preparation techniques was used: a low-load intermittent tooth preparation technique or a high-load tooth preparation technique without intervals. Water flows of 0, 30, and 45 mL/min were associated with each technique, for a total of 6 different groups. The results were analyzed with a 2-factor analysis of variance (P<.05).Results. Temperature increases with the high-load technique were 16.40&DEG;C without cooling (group 1), 11.68&DEG;C with 30 mL/min air-water spray cooling (group III), and 9.96&DEG;C with 45 mL/min cooling (group V). With the low-load tooth preparation technique, a 9.54&DEG;C increase resulted with no cooling (group II), a 1.56&DEG;C increase with 30 mL/min air-water spray cooling (group TV), and a 0.04&DEG;C decrease with 45 mL/min cooling (group VI). The low-load technique was associated with more ideal temperature changes.Conclusion. The results of this study confirm the necessity of using a low-load technique and water coolants during cavity and tooth preparation procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research aim is to study and analyze the shear zone by application of merchant circle during machining of titanium alloy (Ti6Al4V). The thermo-mechanical reaction during machining plays an important role in defining machinability of titanium alloys. The scientific community is concerned about machining of titanium alloy due to problems occurring in the shear zone that affect tool life. Studying the cutting action contributes to understanding and addressing these problems effectively. For this purpose, an experimental setup, utilizing a high speed camera will be used to study the shear zone. The shear zone characteristics are studied by analyzing the images captured by a high speed camera placed near to the shear zone during machining. The experimental design consists of conducting a series of turning trials using combination of cutting parameters namely constant spindle speed (n) 770 rpm; feed rate (f) of 2 and 4 mm/rev; and depth of cut (d) of 1 and 2 mm. The length of cut (L) of 10 mm remains constant and no coolant is used for all trials. The images obtained from the camera are analyzed against the theory of orthogonal cutting using merchants circle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods. Retrospective data from a tear film study using basic high-speed videokeratoscopy, captured at 25 frames per second, (Kopf et al., 2008, J Optom) were used. Eleven subjects had tear film analysis conducted in the morning, midday and evening on the first and seventh day of one week of no lens wear. Five of the eleven subjects then completed an extra week of hydrogel lens wear followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6 second period of the inter-blink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance due to shadows from the eyelashes. A value of tear film surface quality was derived using image rocessing techniques, based on the quality of the reflected ring pattern orientation. Results. The group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than previous methods (average reduction of about 92%). Bare eye measurements from the right and left eyes of eleven individuals showed high correlation values (Pearson’s correlation r = 0.73, p < 0.05). Repeated measures ANOVA across the 6 second period of measurement in the normal inter-blink period for the bare eye condition showed no statistically significant changes. However, across the 6 second inter-blink period with both contact lenses, statistically significant changes were observed (p < 0.001) for both types of contact lens material. Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with the bare eye condition (repeated measures ANOVA, p < 0.0001 for both hydrogel and silicone hydrogel). Conclusions. The results suggest that the dynamic-area method of high-speed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method for noninvasive assessment of tear film surface quality (TFSQ) is proposed. The method is based on high-speed videokeratoscopy in which the corneal area for the analysis is dynamically estimated in a manner that removes videokeratoscopy interference from the shadows of eyelashes but not that related to the poor quality of the precorneal tear film that is of interest. The separation between the two types of seemingly similar videokeratoscopy interference is achieved by region-based classification in which the overall noise is first separated from the useful signal (unaltered videokeratoscopy pattern), followed by a dedicated interference classification algorithm that distinguishes between the two considered interferences. The proposed technique provides a much wider corneal area for the analysis of TFSQ than the previously reported techniques. A preliminary study with the proposed technique, carried out for a range of anterior eye conditions, showed an effective behavior in terms of noise to signal separation, interference classification, as well as consistent TFSQ results. Subsequently, the method proved to be able to not only discriminate between the bare eye and the lens on eye conditions but also to have the potential to discriminate between the two types of contact lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-speed videokeratoscopy is an emerging technique that enables study of the corneal surface and tear-film dynamics. Unlike its static predecessor, this new technique results in a very large amount of digital data for which storage needs become significant. We aimed to design a compression technique that would use mathematical functions to parsimoniously fit corneal surface data with a minimum number of coefficients. Since the Zernike polynomial functions that have been traditionally used for modeling corneal surfaces may not necessarily correctly represent given corneal surface data in terms of its optical performance, we introduced the concept of Zernike polynomial-based rational functions. Modeling optimality criteria were employed in terms of both the rms surface error as well as the point spread function cross-correlation. The parameters of approximations were estimated using a nonlinear least-squares procedure based on the Levenberg-Marquardt algorithm. A large number of retrospective videokeratoscopic measurements were used to evaluate the performance of the proposed rational-function-based modeling approach. The results indicate that the rational functions almost always outperform the traditional Zernike polynomial approximations with the same number of coefficients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.