28 resultados para hemodilution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Acute normovolemic hemodilution (ANH) is an alternative to blood transfusion in surgeries involving blood loss. This experimental study was designed to evaluate whether pulse pressure variation (PPV) would be an adequate tool for monitoring changes in preload during ANH, as assessed by transesophageal echocardiography. Methods. Twenty-one anesthetized and mechanically ventilated pigs were randomized into three groups: CTL (control), HES (hemodilution with 6% hydroxyethyl starch at a 1:1 ratio) or NS (hemodilution with saline 0.9% at a 3:1 ratio). Hemodilution was performed in animals of groups NS and HES in two stages, with target hematocrits 22% and 15%, achieved at 30-minute intervals. After two hours, 50% of the blood volume withdrawn was transfused and animals were monitored for another hour. Statistical analysis was based on ANOVA for repeated measures followed by multiple comparison test (P<0.05). Pearson's correlations were performed between changes in left ventricular end-diastolic volume (LVEDV) and PPV, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP). Results. Group NS received a significantly greater amount of fluids during ANH (NS, 900 +/- 168 mL vs. HES, 200 +/- 50 mL, P<0.05) and presented greater urine output (NS, 2643 +/- 1097mL vs. HES, 641 +/- 338mL, P<0.001). Significant decreases in LVEDV were observed in group NS from completion of ANH until transfusion. In group HES, only increases in LVEDV were observed, at the end of ANH and at transfusion. Such changes in LVEDV (Delta LVEDV) were better reflected by changes in PPV (Delta PPV, R=-0.62) than changes in CVP (Delta CVP R=0.32) or in PAOP (Delta PAOP, R=0.42, respectively). Conclusion. Changes in preload during ANH were detected by changes in PPV. Delta PPV was superior to Delta PAOP and Delta CVP to this end. (Minerva Anestesiol 2012;78:426-33)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Brain injury is responsible for significant morbidity and mortality in trauma patients, but controversy still exists over optimal fluid management for these patients. This study aimed to investigate the effects of acute hemodilution with hydroxyethyl starch (HES) or lactated Ringer`s solution (LR) in intracranial pressure (ICP) and cerebral perfusion pressure (CPP) in dogs submitted to a cryogenic brain injury model. Methods: Design-Prospective laboratory animal study. Setting-Research laboratory in a teaching hospital. Subjects-Thirty-five male mongrel dogs. Interventions-Animals were enrolled to five groups: control, hemodilution with LR or HES 6% to an hematocrit target of 27% or 35%. Results: ICP and CPP levels were measured after cryogenic brain injury. Hemodilution promotes an increment of ICP levels, which decreases CPP when hematocrit target was estimated in 27.% after hemodilution. However, no differences were observed regarding crystalloid or colloid solution used for hemodilution in ICP and CPP levels. Conclusions: Hemodilution to a low hematocrit level increases ICP and decreases CPP scores in dogs submitted to a cryogenic brain injury. These results suggest that excessive hemodilution to a hematocrit below 30% should be avoided in traumatic brain injury patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypoalbuminemia may cause interstitial edema and hemodilution, which we hypothesized may influence serum sodium levels. Our purpose was to compare serum sodium levels of hospitalized adults with or without hypoalbuminemia. All sodium and albumin serum levels of 142 adults hospitalized at general medical wards over a six-month period were searched at a University Hospital mainframe computer. Relevant laboratory data and clinical details were also registered. Hypoalbuminemia was defined by serum albumin concentration < 3.3 g/dl Fisher, Mann-Whitney, and Student's t tests were applied to compare groups with or without hypoalbuminemia. Ninety-nine patients, classified as hypoalbuminemic, had lower blood hemoglobin (10.68 ± 2.62 vs. 13.54 ± 2.41), and sodium (135.1 ± 6.44 vs. 139.9 ± 4.76mEq/l) and albumin (2.74 ± 0.35 vs. 3.58 ± 0.28g/dl) serum levels than non-hypoalbuminemic (n=43). Pearson's coefficient showed a significant direct correlation between albumin and sodium serum levels (r=0.40) and between serum albumin and blood hemoglobin concentration (r=0.46). Our results suggest that hypoalbuminemic adults have lower serum sodium levels than those without hypoalbuminemia, a phenomenon that may be at least partially attributed to body water retention associated with acute phase response syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The best surgical approach for the treatment of patients with severe cerebral artery disease and simultaneous serious coronary artery disease still remains controversial. In this report we present a case of a 72-year-old female patient admitted to the hospital with unstable angina. Triple coronary artery obstructive disease and severe bilateral carotid artery stenosis were diagnosed. A combined, simultaneous surgical procedure was performed. After total circulatory by-pass with a membrane oxygenator, the patient's body temperature was lowered to 32°C. During the cool-down period, three proximal anastomoses of segments of autologous saphenous veins were performed in the ascending aorta. Immediately afterwards, bilateral carotid endarterectomy was performed, followed by three distal anastomoses to coronary arteries. The patient showed a satisfactory post-operative outcome. It was concluded that the combination of moderate hypothermia, hemodilution with appropriate hemodynamic control, as used in this patient, was an effective method of cerebral protection. The simultaneous approach of carotid endarterectomy and coronary artery by-pass surgery should be seen as a safe option for the treatment of this type of patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Jehova's witeness patients deny to receive heterologous blood transfusion even under life risk. They also neither agree with auto transfusion when the their own blood is stored days or weeks before surgery procedures. Percutaneous renal surgery can have complications and, among them, intense hemorrhage that can demand for open surgery. The authors report a case of a 32 year old patient with complete coralliform lithiasis in the right kidney who was submitted to percutaneous renal surgery with removing 400 ml of total blood accompanied subsequently of hemodilution and blood reinfusion by the end of the procedure. A Compact Advanced from Dideco, an italian company, was used for blood recovering during surgery and reinfusing it after the filtration process, centrifugation and washing of red globules. In this particular, the authors describe a technical adaption for blood collection. Both procedures are accepted by Jehova's witness patients, once that the blood is not stored and there is contact with your veined system. This article aim to show a blood capture technical variant in the percutaneous renal surgery, as well as to present a method in similar procedures, once that is not used routinely in urological surgeries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pharmacokinetics of propranolol may be altered by hypothermic cardiopulmonary bypass (CPB), resulting in unpredictable postoperative hemodynamic responses to usual doses. The objective of the present study was to investigate the pharmacokinetics of propranolol in patients undergoing coronary artery bypass grafting (CABG) by CPB under moderate hypothermia. We evaluated 11 patients, 4 women and 7 men (mean age 57 ± 8 years, mean weight 75.4 ± 11.9 kg and mean body surface area 1.83 ± 0.19 m²), receiving propranolol before surgery (80-240 mg a day) and postoperatively (10 mg a day). Plasma propranolol levels were measured before and after CPB by high-performance liquid chromatography. Pharmacokinetic Solutions 2.0 software was used to estimate the pharmacokinetic parameters after administration of the drug pre- and postoperatively. There was an increase of biological half-life from 4.5 (95% CI = 3.9-6.9) to 10.6 h (95% CI = 8.2-14.7; P < 0.01) and an increase in volume of distribution from 4.9 (95% CI = 3.2-14.3) to 8.3 l/kg (95% CI = 6.5-32.1; P < 0.05), while total clearance remained unchanged 9.2 (95% CI = 7.7-24.6) vs 10.7 ml min-1 kg-1 (95% CI = 7.7-26.6; NS) after surgery. In conclusion, increases in drug distribution could be explained in part by hemodilution during CPB. On the other hand, the increase of biological half-life can be attributed to changes in hepatic metabolism induced by CPB under moderate hypothermia. These alterations in the pharmacokinetics of propranolol after CABG with hypothermic CPB might induce a greater myocardial depression in response to propranolol than would be expected with an equivalent dose during the postoperative period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retrograde autologous priming (RAP) has been routinely applied in cardiac pediatric cardiopulmonary bypass (CPB). However, this technique is performed in pediatric patients weighing more than 20 kg, and research about its application in pediatric patients weighing less than 20 kg is still scarce. This study explored the clinical application of RAP in CPB in pediatric patients undergoing cardiac surgery. Sixty pediatric patients scheduled for cardiac surgery were randomly divided into control and experimental groups. The experimental group was treated with CPB using RAP, while the control group was treated with conventional CPB (priming with suspended red blood cells, plasma and albumin). The hematocrit (Hct) and lactate (Lac) levels at different perioperative time-points, mechanical ventilation time, hospitalization duration, and intraoperative and postoperative blood usage were recorded. Results showed that Hct levels at 15 min after CPB beginning (T2) and at CPB end (T3), and number of intraoperative blood transfusions were significantly lower in the experimental group (P<0.05). There were no significant differences in CPB time, aortic blocking time, T2-Lac value or T3-Lac between the two groups (P>0.05). Postoperatively, there were no significant differences in Hct (2 h after surgery), mechanical ventilation time, intensive care unit time, or postoperative blood transfusion between two groups (P>0.05). RAP can effectively reduce the hemodilution when using less or not using any banked blood, while meeting the intraoperative perfusion conditions, and decreasing the perioperative blood transfusion volume in pediatric patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Sepsis is a leading precipitant of Acute Kidney Injury (AKI) in intensive care unit (ICU) patients, and is associated with a high mortality rate. Objective: We aimed to evaluate the risk factors for dialysis and mortality in a cohort of AKI patients of predominantly septic etiology. Methods: Adult patients from an ICU for whom nephrology consultation was requested were included. End-stage chronic renal failure and kidney transplant patients were excluded. Results: 114 patients were followed. Most had sepsis (84%), AKIN stage 3 (69%) and oliguria (62%) at first consultation. Dialysis was performed in 66% and overall mortality was 70%. Median serum creatinine in survivors and non-survivors was 3.95 mg/dl (2.63 - 5.28) and 2.75 mg/dl (1.81 - 3.69), respectively. In the multivariable models, oliguria and serum urea were positively associated with dialysis; otherwise, a lower serum creatinine at first consultation was independently associated with higher mortality. Conclusion: In a cohort of septic AKI, oliguria and serum urea were the main indications for dialysis. We also described an inverse association between serum creatinine and mortality. Potential explanations for this finding include: delay in diagnosis, fluid overload with hemodilution of serum creatinine or poor nutritional status. This finding may also help to explain the low discriminative power of general severity scores - that assign higher risks to higher creatinine levels - in septic AKI patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La résonance magnétique cardiovasculaire sensible à l'oxygénation (OS-CMR) est devenue une modalité d'imagerie diagnostique pour la surveillance de changements dans l'oxygénation du myocarde. Cette technique offre un grand potentiel en tant qu'outil diagnostic primaire pour les maladies cardiovasculaires, en particulier la détection non-invasive d'ischémie. Par contre, il existe plusieurs facteurs potentiellement confondants de cette technique, quelques-uns d'ordre méthodologique comme les paramètres de séquençage et d'autres de nature physiologiques qui sont peut compris. En raison des effets causés par le contenu tissulaire d'eau, l'état d'hydratation peut avoir un impact sur l'intensité du signal. Ceci est un des aspects physiologiques en particulier dont nous voulions quantifier l'effet confondant par la manipulation de l'état d'hydratation chez des humains et l'observation des changements de l'intensité du signal dans des images OS-CMR. Méthodes: In vitro: Du sang artériel et veineux de huit porcs a été utilisé pour évaluer la dilution en série du sang et son effet correspondant sur l'intensité du signal de la séquence OS. In vivo: Vingt-deux volontaires en santé ont subi OS-CMR. Les concentrations d'hémoglobine (Hb) ont été mesurées au niveau de base et immédiatement après une l'infusion cristalloïde rapide de 1000 mL de solution Lactate Ringer's (LRS). Les images OS-CMR ont été prises dans une vue mid-ventriculaire court axe. L'intensité du signal myocardique a été mesurée durant une rétention respiratoire volontaire maximale, suite à une période d'hyperventilation de 60 secondes. Les changements dans l'intensité du signal entre le début et la fin de la rétention de la respiration ont été exprimés relativement au niveau de base (% de changement). Résultats: L'infusion a résulté en une diminution significative de l'Hb mesurée (142.5±3.3 vs. 128.8±3.3 g/L; p<0.001), alors que l'IS a augmenté de 3.2±1.2% entre les images du niveau de base en normo- et hypervolémie (p<0.05). L'IS d'hyperventilation ainsi que les changements d'IS induits par l'apnée ont été attenués après hémodilution (p<0.05). L'évaluation quantitative T2* a démontré une corrélation négative entre le temps de T2* et la concentration d'hémoglobine (r=-0.46, p<0.005). Conclusions: Il existe plusieurs éléments confondants de la technique OS-CMR qui requièrent de l'attention et de l'optimisation pour une future implémentation clinique à grande échelle. Le statut d'hydratation en particulier pourrait être un élément confondant dans l'imagerie OS-CMR. L'hypervolémie mène à une augmentation en IS au niveau de base et atténue la réponse IS durant des manoeuvres de respiration vasoactives. Cette atténuation de l'intensité du signal devrait être tenue en compte et corrigée dans l'évaluation clinique d'images OS-CMR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo foi a padronização de modelo experimental de coração isolado parabiótico em coelhos, testando sua estabilidade e durabilidade, para fins de pesquisa cardiovascular. Foram utilizados 66 coelhos raça Norfolk-2000 divididos em grupo doador do coração isolado e animais suporte, totalizando 33 preparações. Mediante auxilio de bombas peristálticas estabeleceu-se suporte circulatório para o coração isolado mantendo-se fluxo constante(16ml/min.). Um balão intraventricular foi inserido no ventrículo esquerdo, sendo ajustado para gerar pressão diastólica de ± 10mmHg. A freqüência foi fixada em 120 batimentos por minuto mediante o uso de marcapasso. Foram avaliadas variáveis hemodinâmicas, laboratoriais e anatomopatológicas. Das 33 preparações, 13 foram excluídas mediante critérios pré-estabelecidos. Das 20 restantes, 10 cumpriram o tempo máximo do protocolo(180 minutos). Com relação ao animal suporte houve deterioração hemodinâmica progressiva c/ queda da pressão arterial média(89,30±6,09mmHg->47,50±6,35mmHg). Com relação ao corações isolado, das 10 preparações que cumpriram os 180 minutos de protocolo, houve estabilidade hemodinâmica. As variáveis laboratoriais mostraram queda progressiva do sódio, potássio e hemoglobina, sendo compatível com hemodiluição. O exame anatomopatológico mostrou espaçamento maior entre fibras, compatível com edema. O presente modelo mostrou estabilidade e atividade de 100% das preparações em 60 minutos, havendo perdas progressivas chegando a 50% das preparações em atividade em 180 minutos. O presente modelo, dentro das limitações estabelecidas é viável para pesquisas cardiovasculares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)