952 resultados para hematological indices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The policy instruments that provide information on a firm's or facility's environmental performance, such as the U.S. Toxic Release Inventory (TRI) and the Pollutant Release and Transfer Register system (PRTRs) used in some European countries and Japan, play an important role in encouraging firms or facilities to improve their environmental performance, if investors, consumers and residents recognize their environmental performance. This study uses a hedonic approach to explore how the Japanese rental housing market responds to carcinogenic risk arising from releases and transfers of chemical substances produced and used at close facilities. We found that residents do not perceive carcinogenic risk generated more than 1.0 km away from their residence and that they seem to recognize the increased carcinogenic risk at distances from 0.5 km to 1.0 km away; a 1% increase in carcinogenic risk reduces the average rent by 0.0007%. The distance at which residents perceive the risk arising from such facilities is less than in previous studies. This suggests that the risk perception recognized in previous studies may capture the other externalities in addition to the chemical risk because the risk is measured by the distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To estimate refractive indices used with the Lenstar biometer. Methods: Axial lengths of model eyes were determined using an IOLMaster biometer and a Lenstar; comparing these lengths gave an overall eye index for the Lenstar. Using the Lenstar Graphical User interface, we determined that boundaries between media could be manipulated so that there were opposite changes in optical pathlength on either side of the boundary and specified changes in distances determined the ratios of media indices. These ratios were combined with the overall eye index to estimate indices. Results: The IOLMaster and Lenstar produced axial length estimates to within ±0.01 mm. Estimations of group refractive indices were 1.340, 1.341, 1.415 and 1.354 for cornea, aqueous, lens and overall eye, respectively. The aqueous and lens indices, but not those for the cornea, are similar to schematic eye indices and reasonable lens indices. Conclusion: The Lenstar appears to use different refractive indices for different ocular media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a feasibility study on structural damage alarming and localization of long-span cable-supported bridges using multi-novelty indices formulated by monitoring-derived modal parameters. The proposed method which requires neither structural model nor damage model is applicable to structures of arbitrary complexity. With the intention to enhance the tolerance to measurement noise/uncertainty and the sensitivity to structural damage, an improved novelty index is formulated in terms of auto-associative neural networks (ANNs) where the output vector is designated to differ from the input vector while the training of the ANNs needs only the measured modal properties of the intact structure under in-service conditions. After validating the enhanced capability of the improved novelty index for structural damage alarming over the commonly configured novelty index, the performance of the improved novelty index for damage occurrence detection of large-scale bridges is examined through numerical simulation studies of the suspension Tsing Ma Bridge (TMB) and the cable-stayed Ting Kau Bridge (TKB) incurred with different types of structural damage. Then the improved novelty index is extended to formulate multi-novelty indices in terms of the measured modal frequencies and incomplete modeshape components for damage region identification. The capability of the formulated multi-novelty indices for damage region identification is also examined through numerical simulations of the TMB and TKB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Explosive ordnance disposal (EOD) often requires technicians to wear multiple protective garments in challenging environmental conditions. The accumulative effect of increased metabolic cost coupled with decreased heat dissipation associated with these garments predisposes technicians to high levels of physiological strain. It has been proposed that a perceptual strain index (PeSI) using subjective ratings of thermal sensation and perceived exertion as surrogate measures of core body temperature and heart rate, may provide an accurate estimation of physiological strain. Therefore, this study aimed to determine if the PeSI could estimate the physiological strain index (PSI) across a range of metabolic workloads and environments while wearing heavy EOD and chemical protective clothing. Methods Eleven healthy males wore an EOD and chemical protective ensemble while walking on a treadmill at 2.5, 4 and 5.5 km·h− 1 at 1% grade in environmental conditions equivalent to wet bulb globe temperature (WBGT) 21, 30 and 37 °C. WBGT conditions were randomly presented and a maximum of three randomised treadmill walking trials were completed in a single testing day. Trials were ceased at a maximum of 60-min or until the attainment of termination criteria. A Pearson's correlation coefficient, mixed linear model, absolute agreement and receiver operating characteristic (ROC) curves were used to determine the relationship between the PeSI and PSI. Results A significant moderate relationship between the PeSI and the PSI was observed [r = 0.77; p < 0.001; mean difference = 0.8 ± 1.1 a.u. (modified 95% limits of agreement − 1.3 to 3.0)]. The ROC curves indicated that the PeSI had a good predictive power when used with two, single-threshold cut-offs to differentiate between low and high levels of physiological strain (area under curve: PSI three cut-off = 0.936 and seven cut-off = 0.841). Conclusions These findings support the use of the PeSI for monitoring physiological strain while wearing EOD and chemical protective clothing. However, future research is needed to confirm the validity of the PeSI for active EOD technicians operating in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-endurance exercise, such as an Ironman triathlon, induces muscle damage and a systemic inflammatory response. As the resolution of recovery in these parameters is poorly documented, we investigated indices of muscle damage and systemic inflammation in response to an Ironman triathlon and monitored these parameters 19 days into recovery. Blood was sampled from 42 well-trained male triathletes 2 days before, immediately after, and 1, 5 and 19 days after an Ironman triathlon. Blood samples were analyzed for hematological profile, and plasma values of myeloperoxidase (MPO), polymorphonuclear (PMN) elastase, cortisol, testosterone, creatine kinase (CK) activity, myoglobin, interleukin (IL)-6, IL-10 and high-sensitive C-reactive protein (hs-CRP). Immediately post-race there were significant (P < 0.001) increases in total leukocyte counts, MPO, PMN elastase, cortisol, CK activity, myoglobin, IL-6, IL-10 and hs-CRP, while testosterone significantly (P < 0.001) decreased compared to prerace. With the exception of cortisol, which decreased below prerace values (P < 0.001), these alterations persisted 1 day post-race (P < 0.001; P < 0.01 for IL-10). Five days post-race CK activity, myoglobin, IL-6 and hs-CRP had decreased, but were still significantly (P < 0.001) elevated. Nineteen days post-race most parameters had returned to prerace values, except for MPO and PMN elastase, which had both significantly (P < 0.001) decreased below prerace concentrations, and myoglobin and hs-CRP, which were slightly, but significantly higher than prerace. Furthermore, significant relationships between leukocyte dynamics, cortisol, markers of muscle damage, cytokines and hs-CRP after the Ironman triathlon were noted. This study indicates that the pronounced initial systemic inflammatory response induced by an Ironman triathlon declines rapidly. However, a low-grade systemic inflammation persisted until at least 5 days post-race, possibly reflecting incomplete muscle recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Magnetic resonance diffusion tensor imaging (DTI) shows promise in the early detection of microstructural pathophysiological changes in the brain. Objectives: To measure microstructural differences in the brains of participants with amnestic mild cognitive impairment (MCI) compared with an age-matched control group using an optimised DTI technique with fully automated image analysis tools and to investigate the correlation between diffusivity measurements and neuropsychological performance scores across groups. Methods: 34 participants (17 participants with MCI, 17 healthy elderly adults) underwent magnetic resonance imaging (MRI)-based DTI. To control for the effects of anatomical variation, diffusion images of all participants were registered to standard anatomical space. Significant statistical differences in diffusivity measurements between the two groups were determined on a pixel-by-pixel basis using gaussian random field theory. Results: Significantly raised mean diffusivity measurements (p<0.001) were observed in the left and right entorhinal cortices (BA28), posterior occipital-parietal cortex (BA18 and BA19), right parietal supramarginal gyrus (BA40) and right frontal precentral gyri (BA4 and BA6) in participants with MCI. With respect to fractional anisotropy, participants with MCI had significantly reduced measurements (p<0.001) in the limbic parahippocampal subgyral white matter, right thalamus and left posterior cingulate. Pearson's correlation coefficients calculated across all participants showed significant correlations between neuropsychological assessment scores and regional measurements of mean diffusivity and fractional anisotropy. Conclusions: DTI-based diffusivity measures may offer a sensitive method of detecting subtle microstructural brain changes associated with preclinical Alzheimer's disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To estimate refractive indices used by the Lenstar biometer to translate measured optical path lengths into geometrical path lengths within the eye. METHODS Axial lengths of model eyes were determined using the IOLMaster and Lenstar biometers; comparing those lengths gave an overall eye refractive index estimate for the Lenstar. Using the Lenstar Graphical User Interface, we noticed that boundaries between media could be manipulated and opposite changes in optical path lengths on either side of the boundary could be introduced. Those ratios were combined with the overall eye refractive index to estimate separate refractive indices. Furthermore, Haag-Streit provided us with a template to obtain 'air thicknesses' to compare with geometrical distances. RESULTS The axial length estimates obtained using the IOLMaster and the Lenstar agreed to within 0.01 mm. Estimates of group refractive indices used in the Lenstar were 1.340, 1.341, 1.415, and 1.354 for cornea, aqueous, lens, and overall eye, respectively. Those refractive indices did not match those of schematic eyes, but were close in the cases of aqueous and lens. Linear equations relating air thicknesses to geometrical thicknesses were consistent with our findings. CONCLUSION The Lenstar uses different refractive indices for different ocular media. Some of the refractive indices, such as that for the cornea, are not physiological; therefore, it is likely that the calibrations in the instrument correspond to instrument-specific corrections and are not the real optical path lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic recordings play an increasingly important role in monitoring terrestrial environments. However, due to rapid advances in technology, ecologists are accumulating more audio than they can listen to. Our approach to this big-data challenge is to visualize the content of long-duration audio recordings by calculating acoustic indices. These are statistics which describe the temporal-spectral distribution of acoustic energy and reflect content of ecological interest. We combine spectral indices to produce false-color spectrogram images. These not only reveal acoustic content but also facilitate navigation. An additional analytic challenge is to find appropriate descriptors to summarize the content of 24-hour recordings, so that it becomes possible to monitor long-term changes in the acoustic environment at a single location and to compare the acoustic environments of different locations. We describe a 24-hour ‘acoustic-fingerprint’ which shows some preliminary promise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a wide class of semi-Markov decision processes the optimal policies are expressible in terms of the Gittins indices, which have been found useful in sequential clinical trials and pharmaceutical research planning. In general, the indices can be approximated via calibration based on dynamic programming of finite horizon. This paper provides some results on the accuracy of such approximations, and, in particular, gives the error bounds for some well known processes (Bernoulli reward processes, normal reward processes and exponential target processes).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a multiarmed bandit problem with exponential discounting the optimal allocation rule is defined by a dynamic allocation index defined for each arm on its space. The index for an arm is equal to the expected immediate reward from the arm, with an upward adjustment reflecting any uncertainty about the prospects of obtaining rewards from the arm, and the possibilities of resolving those uncertainties by selecting that arm. Thus the learning component of the index is defined to be the difference between the index and the expected immediate reward. For two arms with the same expected immediate reward the learning component should be larger for the arm for which the reward rate is more uncertain. This is shown to be true for arms based on independent samples from a fixed distribution with an unknown parameter in the cases of Bernoulli and normal distributions, and similar results are obtained in other cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explore the use of Gittins indices to search for near optimality in sequential clinical trials. Some adaptive allocation rules are proposed to achieve the following two objectives as far as possible: (i) to reduce the expected successes lost, (ii) to minimize the error probability at the end. Simulation results indicate the merits of the rules based on Gittins indices for small trial sizes. The rules are generalized to the case when neither of the response densities is known. Asymptotic optimality is derived for the constrained rules. A simple allocation rule is recommended for one-stage models. The simulation results indicate that it works better than both equal allocation and Bather's randomized allocation. We conclude with a discussion of possible further developments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the capacity of several published multispectral indices to estimate the nitrogen nutrition of wheat canopies grown under different levels of water supply and plant density and derived a simple canopy reflectance index that is greatly independent of those factors. Planar domain geometry was used to account for mixed signals from the canopy and soil when the ground cover was low. A nitrogen stress index was developed, which adjusts shoot %N for plant biomass and area, thereby accounting for environmental conditions that affect growth, such as crop water status. The canopy chlorophyll content index (CCCi) and the modified spectral ratio planar index (mSRPi) could explain 68 and 69% of the observed variability in the nitrogen nutrition of the crop as early as Zadoks 33, irrespective of water status or ground cover. The CCCi was derived from the combination of 3 wavebands 670, 720 and 790 nm, and the mSRPi from 445, 705 and 750 nm, together with broader bands in the NIR and RED. The potential for their spatial application over large fields/paddocks is discussed.