995 resultados para head loss


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design of a lateral line for drip irrigation requires accurate evaluation of head losses in not only the pipe but in the emitters as well. A procedure was developed to determine localized head losses within the emitters by the formulation of a mathematical model that accounts for the obstruction caused by the insertion point. These localized losses can be significant when compared with tire total head losses within the system due to the large number of emitters typically installed along the lateral line. Air experiment was carried out by altering flow characteristics to create Reynolds numbers (R) from 7,480 to 32,597 to provide turbulent flow and a maximum velocity of 2.0 m s(-1). The geometry of the emitter was determined by an optical projector and sensor An equation was formulated to facilitate the localized head loss calculation using the geometric characteristics of the emitter (emitter length, obstruction ratio, and contraction coefficient). The mathematical model was tested using laboratory measurements on four emitters. The local head loss was accurately estimated for the Uniram (difference of +13.6%) and Drip Net (difference of +7.7%) emitters, while appreciable deviations were found for the Twin Plus (-21.8%) and Tiran (+50%) emitters. The head loss estimated by the model was sensitive to the variations in the obstruction area of the emitter However, the variations in the local head loss did not result in significant variations in the maximum length of the lateral lines. In general, for all the analyzed emitters, a 50% increase in the local head loss for the emitters resulted in less than an 8% reduction in the maximum lateral length.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Local head losses must be considered in estimating properly the maximum length of drip irrigation laterals. The aim of this work was to develop a model based on dimensional analysis for calculating head loss along laterals accounting for in-line drippers. Several measurements were performed with 12 models of emitters to obtain the experimental data required for developing and assessing the model. Based on the Camargo & Sentelhas coefficient, the model presented an excellent result in terms of precision and accuracy on estimating head loss. The deviation between estimated and observed values of head loss increased according to the head loss and the maximum deviation reached 0.17 m. The maximum relative error was 33.75% and only 15% of the data set presented relative errors higher than 20%. Neglecting local head losses incurred a higher than estimated maximum lateral length of 19.48% for pressure-compensating drippers and 16.48% for non pressure-compensating drippers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The knowledge of insulation debris generation and transport gains in importance regarding reactor safety research for PWR and BWR. The insulation debris released near the break consists of a mixture of very different fibres and particles concerning size, shape, consistence and other properties. Some fraction of the released insulation debris will be transported into the reactor sump where it may affect emergency core cooling. Experiments are performed to blast original samples of mineral wool insulation material by steam under original thermal-hydraulic break conditions of BWR. The gained fragments are used as initial specimen for further experiments at acrylic glass test facilities. The quasi ID-sinking behaviour of the insulation fragments are investigated in a water column by optical high speed video techniques and methods of image processing. Drag properties are derived from the measured sinking velocities of the fibres and observed geometric parameters for an adequate CFD modelling. In the test rig "Ring line-II" the influence of the insulation material on the head loss is investigated for debris loaded strainers. Correlations from the filter bed theory are adapted with experimental results and are used to model the flow resistance depending on particle load, filter bed porosity and parameters of the coolant flow. This concept also enables the simulation of a particular blocked strainer with CFDcodes. During the ongoing work further results of separate effect and integral experiments and the application and validation of the CFD-models for integral test facilities and original containment sump conditions are expected.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As a way to reduce water losses in furrow irrigation systems, used in fresh market tomato production, farmers are improperly distributing water into the field using plastic hose. The objective of this work was to study the suitability of using quick coupler sprinkler as hose connectors for water distribution in tomato plantation. The first step of the study was to assess the current hose field operation for tomato growers. Subsequently, four models of quick couplers sprinklers available in the market were tested in laboratory to determine the coefficient of resistance, the equivalent tube length, the head loss curve and the linking efficiency. As result, a structural design for hose connectors was presented using the model of coupling with the best hydraulic performance. Additionally, some technical recommendations on its use in irrigation water distribution are highlighted. Despite the requirement for additional field trials, the proposed system has potential to optimize the water use efficiency, to improve workers ergonomic conditions, and ensure good profitability to the producer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

On this paper, the results of an experimental study oil the hydraulic friction loss for small-diameter polyethylene pipes are reported. The experiment was carried out using a range of Reynolds number between 6000 to 72000, obtained by varying discharge at 20 degrees C water temperature, with internal pipe diameters of 10.0 mm, 12.9 mm, 16.1 mm, 17.4 mm and 19.7 mm. According to the analysis results and experimental conditions, the friction factor 0 of the Darcy-Weisbach equation call be estimated with c = 0.300 and m = 0.25. The Blasius equation (c = 0.316 and m = 0.25) gives an overestimate of friction loss, although this fact is non-restrictive for micro-irrigation system designs. The analysis shows that both the Blasius and the adjusted equation parameters allow for accurate friction factor estimates, characterized by low mean error (5.1%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Clogging, measured through head loss across filters, and the filtration quality of different filters using different effluents were studied. The filters used were: 115, 130, and 200 m disc filters; 98, 115, 130, and 178 m screen filters; and a sand filter filled with a single layer of sand with an effective diameter of 0.65 mm. The filters were used with a meat industry effluent and secondary and tertiary effluents of two wastewater treatment plants. It was observed that clogging depended on the type of effluent. With the meat industry effluent, the poorest quality effluent, disc filters clogged more than the other filter types. When the wastewater treatment plant effluents were used, the disc filters showed less frequent clogging. Several physical and chemical parameters, such as total suspended solids, chemical oxygen demand, turbidity, electrical conductivity, pH, and number of particles, were analyzed in the effluents at the entry and exit points of the filters. In general, filters did not reduce the values of the main clogging parameters to a great degree. It was found that the parameter that explained the clogging, expressed as Boucher’s filterability index, was different depending on the type of effluent and filter. The best quality of filtration was achieved with a sand filter when the meat industry effluent was used. No significant differences were observed between the quality of filtration of disc and screen filters when operating with the secondary and tertiary effluents

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work is to study flow properties at T-junction of pipe, pressure loss suffered by the flow after passing through T-junction and to study reliability of the classical engineering formulas used to find head loss for T-junction of pipes. In this we have compared our results with CFD software packages with classical formula and made an attempt to determine accuracy of the classical formulas. In this work we have studies head loss in T-junction of pipes with various inlet velocities, head loss in T-junction of pipes when the angle of the junction is slightly different from 90 degrees and T-junction with different area of cross-section of the main pipe and branch pipe. In this work we have simulated the flow at T-junction of pipe with FLUENT and Comsol Multiphysics and observed flow properties inside the T-junction and studied the head loss suffered by fluid flow after passing through the junction. We have also compared pressure (head) losses obtained by classical formulas by A. Vazsonyi and Andrew Gardel and formulas obtained by assuming T-junction as combination of other pipe components and observations obtained from software experiments. One of the purposes of this study is also to study change in pressure loss with change in angle of T-junction. Using software we can have better view of flow inside the junction and study turbulence, kinetic energy, pressure loss etc. Such simulations save a lot of time and can be performed without actually doing the experiment. There were no real life experiments made, the results obtained completely rely on accuracy of software and numerical methods used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Turun seudulla kuuden kunnan jätevesien käsittely keskitetään Kakolanmäen kallion sisälle rakennettuun jätevedenpuhdistamoon, joka otetaan käyttöön vuoden 2008 lopulla. Kakolanmäen jätevedenpuhdistamolla on varauduttu tulevaisuudessa kiristyviin lupaehtoihin sekä mahdollisiin puhdistetun jäteveden hygieenistä laatua koskeviin lisämääräyksiin jättämällä tilavaraus puhdistetun jäteveden desinfioimiselle ultraviolettivalolla. Diplomityössä on selvitetty vuoden kestäneessä tutkimusjaksossa 1.9.2006- 31.8.2007 Turun kaupungin keskuspuhdistamolta mereen johdetun puhdistetun jäteveden ja esiselkeytetyn ohitusveden hygieenisen laadun vaihtelua. Jäteveden desinfiointitarvetta on arvioitu tarkastelemalla jätevedenpuhdistamon hygieenistä puhdistustulosta ja jätevesien vaikutusta purkuvesistön hygieeniseen tilaan. Tutkimuksen perusteella virtaama ei vaikuttanut merkittävästi jäteveden ulosteperäisten bakteerien määriin. Sen sijaan jäteveden bakteeripitoisuudet laskivat alhaisissa lämpötiloissa. Lämpötilan vaikutus näkyi selkeämmin esiselkeytetyssä kuin puhdistetussa jätevedessä eli bakteerien poistumiseen aktiivilietevaiheen aikana vaikuttavat muut tekijät. Mitä tehokkaammin aktiivilietevaihe toimi, sitä tehokkaammin myös bakteereja poistui. Taudinaiheuttajabakteerit selvisivät puhdistusprosessista paremmin viileän kauden aikana. Puhdistetun jäteveden hygieeninen laatu ei täyttänyt uimaveden tai kasteluveden laatuvaatimuksia, joten desinfiointitarve olisi perustelua. Jätevesien vaikutus Turun edustan merialueen hygieeniseen tilaan näkyi ajoittain korkeina bakteeripitoisuuksina purkupaikan lähistöllä. Vielä ei ole suoraa näyttöä siitä aiheuttavatko jätevedet purkupaikan lähistön uimarannoilla terveydellisiä riskejä. Jäteveden UV-desinfiointi kannattava toteuttaa vain jos hygieeninen puhdistusvelvoite määrätään. UV-desinfioinnin mitoituksessa Kakolanmäen jätevedenpuhdistamolla tulee ottaa huomioon suurin sallittu hydraulinen painehäviö. Mitoitus voidaan tehdä puhdistamon käyttöönoton jälkeen kun tarvitut prosessimittaustiedot ovat saatavilla.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study is presented an economic optimization method to design telescope irrigation laterals (multidiameter) with regular spaced outlets. The proposed analytical hydraulic solution was validated by means of a pipeline composed of three different diameters. The minimum acquisition cost of the telescope pipeline was determined by an ideal arrangement of lengths and respective diameters for each one of the three segments. The mathematical optimization method based on the Lagrange multipliers provides a strategy for finding the maximum or minimum of a function subject to certain constraints. In this case, the objective function describes the acquisition cost of pipes, and the constraints are determined from hydraulic parameters as length of irrigation laterals and total head loss permitted. The developed analytical solution provides the ideal combination of each pipe segment length and respective diameter, resulting in a decreased of the acquisition cost.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents an experimental research about the behavior of two-phase flows in inclined pipes. The inclination angle varied from 5° to 45° and the slurry solid concentration varied up to 15%. It was concluded that the head losses of the downward sloping pipe flow are always lower than the head losses of the horizontal flow and these are always lower than the head losses of the upward sloping pipe flow, regardless the concentration and inclination angle. It was possible to develop empirical equations to calculate the head losses of the horizontal flow and the upward and downward sloping pipe flows.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Kandidaatintyössä pyritään löytämään mittausjärjestelyt takaiskuventtiilin painehäviön mittaamiseksi laboratorio-olosuhteissa. Käyttöolosuhteissa putkistossa on laboratorio-olosuhteita suuremmat virtausnopeudet ja paineet, mikä vaikuttaa fluidin käyttäytymiseen ja siten mittaustulokseen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O hidrociclone é um equipamento amplamente utilizado pela indústria em processos envolvendo separação sólido-líquido, porém ainda pouco utilizado na agricultura irrigada no Brasil. Neste trabalho, avaliou-se o desempenho deste equipamento como pré-filtrante de partículas sólidas, oriundas dos processos erosivos e do assoreamento dos recursos hídricos. Os testes foram realizados com um hidrociclone de geometria Rietema, possuindo diâmetro de 19,2 cm na parte cilíndrica, operando com vazões variando entre 10 m³ h-1 e 27 m³ h-1. Os materiais particulados usados em suspensão foram: solo franco-argiloso e areia de rio. Os resultados mostraram que a perda de carga máxima média foi de 52 kPa e 47 kPa para as suspensões aquosas de areia e solo, respectivamente. Seu melhor desempenho ocorreu operando com suspensão aquosa de areia, apresentando eficiência total de 92,3% para a vazão de 26,9 m³ h-1. Concluiu-se que o equipamento avaliado é mais eficiente para remoção de partículas de areia, podendo ser utilizado como pré-filtro em sistemas de irrigação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this work was to characterize chemical and mineralogical the water supply networks and to assess the hydraulic recovery on high-degraded pipe. Thus, the resistance (by pitometric essays), chemical analyses (ICP-MS and ICP-ES), mineralogical analysis (petrographic thin sections, X-ray difractometry and scanning electronic microscopy), hardness (Mohs scale) and simulations for pipe's change and rehabilitations scenarios were investigated (from Scenario 1 to 4). The results showed that the high-degraded pipe had a limited recovery (from 3,9 to 14,0 m(0,367).s(-1)). The deposits were formed by oxide and hydroxide of iron (magnetite and goethite), which are materials of high hardness (6 on Mohs scale). The simulations indicated the required power ratio (C-i/C-1) around 86.00, 1.00 and 0.02% in relation to present scenario.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A filtração em múltiplas etapas (FiME) se apresenta como uma alternativa para realizar o tratamento de água de comunidades de pequeno porte, entretanto, a eficiência quanto à remoção de cor verdadeira associada ao carbono orgânico dissolvido (COD) ou às substâncias húmicas, tem sido questionada ou relatada como baixa. A presente pesquisa avaliou a remoção de substâncias húmicas na FiME com pré-oxidação, com ozônio e peróxido de hidrogênio, utilizando para essa avaliação parâmetros indiretos como cor verdadeira, absorvância UV (254 nm) e COD. Foram realizados cinco ensaios, utilizando quatro filtros lentos, sendo dois com camada de carvão ativado granular (CAG). Foram ensaiadas várias alternativas de pré-oxidação com ozônio e peróxido de hidrogênio. Foram obtidos bons resultados, tendo como principal conclusão que os filtros lentos com CAG, precedidos de oxidação com ozônio e depois peróxido de hidrogênio, apresentaram remoção média de cor verdadeira de 64%, mas que o peróxido de hidrogênio afeta o desenvolvimento da camada biológica, interferindo no desenvolvimento da perda de carga, na remoção de turbidez, na remoção de coliformes e na remoção de substâncias húmicas.