173 resultados para haemodynamic
Resumo:
Background and objective The time course of cardiopulmonary alterations after pulmonary embolism has not been clearly demonstrated and nor has the role of systemic inflammation on the pathogenesis of the disease. This study aimed to evaluate over 12 h the effects of pulmonary embolism caused by polystyrene microspheres on the haemodynamics, lung mechanics and gas exchange and on interleukin-6 production. Methods Ten large white pigs (weight 35-42 kg) had arterial and pulmonary catheters inserted and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter similar to 300 mu mol l(-1)) until a value of pulmonary mean arterial pressure of twice the baseline was obtained. Five other animals received only saline. Haemodynamic and respiratory data and pressure-volume curves of the respiratory system were collected. A bronchoscopy was performed before and 12 h after embolism, when the animals were euthanized. Results The embolism group developed hypoxaemia that was not corrected with high oxygen fractions, as well as higher values of dead space, airway resistance and lower respiratory compliance levels. Acute haemodynamic alterations included pulmonary arterial hypertension with preserved systemic arterial pressure and cardiac index. These derangements persisted until the end of the experiments. The plasma interleukin-6 concentrations were similar in both groups; however, an increase in core temperature and a nonsignificant higher concentration of bronchoalveolar lavage proteins were found in the embolism group. Conclusion Acute pulmonary embolism induced by polystyrene microspheres in pigs produces a 12-h lasting hypoxaemia and a high dead space associated with high airway resistance and low compliance. There were no plasma systemic markers of inflammation, but a higher central temperature and a trend towards higher bronchoalveolar lavage proteins were found. Eur J Anaesthesiol 27:67-76 (C) 2010 European Society of Anaesthesiology.
Resumo:
Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.
Resumo:
Introduction: The ACCM/PALS guidelines address early correction of paediatric septic shock using conventional measures. In the evolution of these recommendations, indirect measures of the balance between systemic oxygen delivery and demands using central venous or superior vena cava oxygen saturation ( ScvO(2) >= 70%) in a goal-directed approach have been added. However, while these additional goal-directed endpoints are based on evidence-based adult studies, the extrapolation to the paediatric patient remains unvalidated. Objective: The purpose of this study was to compare treatment according to ACCM/PALS guidelines, performed with and without ScvO(2) goal-directed therapy, on the morbidity and mortality rate of children with severe sepsis and septic shock. Design, participants and interventions: Children and adolescents with severe sepsis or fluid-refractory septic shock were randomly assigned to ACCM/PALS with or without ScvO(2) goal-directed resuscitation. Measurements: Twenty-eight-day mortality was the primary endpoint. Results: Of the 102 enrolled patients, 51 received ACCM/PALS with ScvO(2) goal-directed therapy and 51 received ACCM/PALS without ScvO(2) goal-directed therapy. ScvO(2) goal-directed therapy resulted in less mortality ( 28-day mortality 11.8% vs. 39.2%, p = 0.002), and fewer new organ dysfunctions ( p = 0.03). ScvO(2) goal-directed therapy resulted in more crystalloid ( 28 ( 20-40) vs. 5 ( 0-20) ml/kg, p < 0.0001), blood transfusion ( 45.1% vs. 15.7%, p = 0.002) and inotropic ( 29.4% vs. 7.8%, p = 0.01) support in the first 6 h. Conclusions: This study supports the current ACCM/PALS guidelines. Goal-directed therapy using the endpoint of a ScvO(2) = 70% has a significant and additive impact on the outcome of children and adolescents with septic shock.
Resumo:
Acute pulmonary embolism produces acute pulmonary hypertension, which can be counteracted by activating the nitric oxide-cyclic guanosine 3`,5`-monophosphate (cGMP) pathway. While previous studies have shown that sildenafil (an inhibitor of cGMP-specific phosphodiesterase type 5) or nitrite (a storage molecule for nitric oxide) produces beneficial effects during acute pulmonary embolism, no previous study has examined whether the combination of these drugs can produce additive effects. Here, we expand previous findings and examine whether sildenafil enhances the beneficial haemodynamic effects produced by a low-dose infusion of nitrite in a dog model of acute pulmonary embolism. Haemodynamic and arterial blood gas evaluations were performed in non-embolized dogs treated with saline (n = 4), and in embolized dogs (intravenous injections of microspheres) that received nitrite (6.75 mu mol/kg intravenously over 15 min. followed by 0.28 mu mol/kg/min.) and sildenafil (0.25 mg/kg over 30 min.; n = 8), or nitrite followed by saline (n = 8), or saline followed by sildenafil (n = 7), or only saline (n = 8). Plasma thiobarbituric acid-reactive substances (TBARS) concentrations were determined using a fluorometric method. Acute pulmonary embolism increased pulmonary artery pressure by similar to 24 mmHg. While the infusion of nitrite or sildenafil infusions reversed this increase by similar to 42% (both P < 0.05), the combined infusion of both drugs reversed this increase by similar to 58% (P < 0.05). Similar effects were seen on the pulmonary vascular resistance index. Nitrite or sildenafil alone produced no significant hypotension. However, the combined infusion of both drugs caused transient hypotension (P < 0.05). Both dugs, either alone or combined, blunted the increase in TBARS concentrations caused by acute pulmonary embolism (all P < 0.05). These results suggest that sildenafil improves the beneficial haemodynamic effects of nitrite during acute pulmonary embolism.
Resumo:
There has been limited investigation of parturition in the bitch and there is little information published on clinical and obstetrical examination other than opinion and anecdote. While there are substantial data on haemodynamic and vascular changes during normal parturition in humans, little is known about the physiological events in the dog. This study was aimed at maternal haemodynamic changes occurring during normal parturition and to investigate how these were modified in bitches with dystocia (DYST) treated either medically or via assisted delivery and caesarean operation. Three groups of 10 bitches were investigated; those with normal parturition, those with DYST corrected by manipulative assistance or caesarean operation and those with uterine inertia treated by oxytocin administration. Heart rate, systolic and diastolic blood pressure, electrocardiogram and blood glucose concentration were measured pre-partum, intra-partum, immediately after parturition and 1 h later. Heart rate was high at all times throughout the study and the majority of bitches had normal sinus rhythm. Blood pressure was generally within the normal range, and although systolic and diastolic blood pressure was highest during the intra-partum period and sometimes during the immediate post-partum period, there were no significant differences between groups. All bitches had blood glucose concentrations within the normal range throughout the study although pre-partum concentrations were statistically lower than many of the other time periods. The study provides useful physiological data that will facilitate monitoring and clinical management of bitches throughout normal parturition and DYST.
Resumo:
This study investigated the haemodynamic response to the 90-minute application of 85 Hz transcutaneous electrical nerve stimulation (TENS) to the T1 and T5 nerve roots. Comparison was made between 20 healthy subjects who had TENS stimulation and a separate group of 20 healthy subjects who rested for 90 minutes. Pulse and blood pressure were measured just prior to the start of TENS stimulation, after 30 minutes of stimulation, and after 90 minutes of stimulation (immediately after stopping TENS) or at completion of the rest time depending on group allocation. The rate pressure product was calculated from the pulse and systolic blood pressure data. Multivariate repeated measures analysis showed a significant group effect for TENS (p = 0.048). Univariate repeated measures analyses showed a significant group by time effect due to TENS on systolic blood pressure over the 90-minute time period (p = 0.028). Separate group repeated measures ANOVA showed a significant decline in heart rate (p = 0.000), systolic blood pressure (p = 0.013) and rate pressure product (p = 0.000) for the TENS group, while the control resting group showed a significant decline in heart rate only (p = 0.04). The application of 85 Hz TENS to the upper thoracic nerve roots causes no adverse haemodynamic effects in healthy subjects.
Resumo:
Objectivo: estudo comparativo simultâneo de medições invasivas utilizando o cateterismo da artéria pulmonar e não invasivas utilizando a ecocardiografia transtorácica (ETT) de 4 parâmetros hemodinâmicos: débito cardíaco (DC), pressão de encravamento da artéria pulmonar (PCP), pressão venosa central (PVC), e pressão sistólica da artéria pulmonar (PSAP). Material e Métodos: estudo prospectivo numa Unidade de Cuidados Intensivos (UCI) médico-cirurgica. Foram estudados 41 doentes em pós-operatório de transplante hepático, nos quais o DC, a PCP, a PVC e a PSAP foram obtidos em simultâneo por 2 observadores independentes, utilizando a ETT e o cateterismo invasivo da artéria pulmonar. Para a quantificação por ETT dos parâmetros foram utilizadas fórmulas descritas na literatura. As medições invasivas e não invasivas foram comparadas através de uma análise de correlação linear e de Bland-Altman. Resultados: Verificou-se uma boa correlação nas medições invasivas e não invasivas do DC (r=0,97) e PVC (r=0,88). As correlações entre as medições invasivas e não invasivas da PCP e da PSAP foram fracas (r=0,41 e r= 0,118 respectivamente). O intervalo de confiança de 95% e bias para o DC foi negligenciável, em especial para valores de DC abaixo dos 6l/minuto. A ETT subestima em regra o DC, mas as duas técnicas mostraram uma correlação significativa entre si. Conclusões: a ETT pode estimar de forma fidedigna o DC em doentes submetidos a transplante hepático. A determinação não invasiva das restantes variáveis hemodinâmicas por ETT pode estar sujeita a uma variabilidade grande relacionada com as características dos doentes. Apesar dos dados terem sido obtidos num grupo específico de doentes, podem ajudar a definir uma aplicação futura da ecocardiografia em Cuidados Intensivos.
Resumo:
BACKGROUND: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. METHODS: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over undergoing major non-cardiac surgery in a 7-day period in April 2011 were included into this analysis. The objective is to describe prevalence and type of cardiac output monitoring used in major surgery in Europe. RESULTS: Included in the analysis were 12,170 patients from the surgical services of 426 hospitals in 28 European nations. One thousand four hundred and sixteen patients (11.6 %) were exposed to cardiac output monitoring, and 2343 patients (19.3 %) received a central venous catheter. Patients with higher American Society of Anesthesiologists (ASA) scores were more frequently exposed to cardiac output monitoring (ASA I and II, 643 patients [8.6 %]; ASA III-V, 768 patients [16.2 %]; p < 0.01) and central venous catheter (ASA I and II, 874 patients [11.8 %]; ASA III-V, 1463 patients [30.9 %]; p < 0.01). In elective surgery, 990 patients (10.8 %) were exposed to cardiac output monitoring, in urgent surgery 252 patients (11.7 %) and in emergency surgery 173 patients (19.8 %). A central venous catheter was used in 1514 patients (16.6 %) undergoing elective, in 480 patients (22.2 %) undergoing urgent and in 349 patients (39.9 %) undergoing emergency surgery. Nine hundred sixty patients (7.9 %) were monitored using arterial waveform analysis, 238 patients (2.0 %) using oesophageal Doppler ultrasound, 55 patients (0.5 %) using a pulmonary artery catheter and 44 patients (2.0 %) using other technologies. Across nations, cardiac output monitoring use varied from 0.0 % (0/249 patients) to 27.5 % (19/69 patients), whilst central venous catheter use varied from 5.6 % (7/125 patients) to 43.2 % (16/37 patients). CONCLUSIONS: One in ten patients undergoing major surgery is exposed to cardiac output monitoring whilst one in five receives a central venous catheter. The use of both technologies varies widely across Europe.
Resumo:
1. The haemodynamic and humoral effects of cilazapril, a new angiotensin converting enzyme (ACE) inhibitor, were evaluated in normotensive healthy volunteers. 2. Single oral doses of 1.25, 2.5, 5 and 10 mg of cilazapril inhibited ACE by greater than or equal to 90% and induced the expected pattern of changes of the renin-angiotensin-aldosterone-system. 3. Cilazapril had a long duration of action, since some ACE inhibition was still present 72 h after drug intake. 4. Cilazapril administered intravenously at doses of 5 and 20 micrograms kg-1 for 24 h did not produce any significant effects. 5. During repeated administration of cilazapril for 8 days, no accumulation of cilazaprilat was observed and the clinical tolerance was excellent. 6. In normal volunteers, cilazapril administered orally acts as a potent inhibitor of converting enzyme.
Resumo:
BACKGROUND: A rapid decrease of serum potassium concentrations during haemodialysis produces a significant increase in blood pressure parameters at the end of the session, even if effects on intra-dialysis pressure are not seen. Paradoxically, in animal models potassium is a vasodilator and decreases myocardial contractility. The purpose of this trial is to study the precise haemodynamic consequences induced by acute changes in potassium concentration during haemodialysis. METHODS: In 24 patients, 288 dialysis sessions, using a randomised single blind crossover design, we compared six dialysate sequences with different potassium profiles. The dialysis sessions were divided into 3 tertiles, casually modulating potassium concentration in the dialysate between the value normally used K and the two cut-off points K+1 and K-1 mmol/l. Haemodynamics were evaluated in a non-invasive manner using a finger beat-to-beat monitor. RESULTS: Comparing K-1 and K+1, differences were found within the tertiles regarding systolic (+5.3, +6.6, +2.3 mmHg, p < 0.05, < 0.05, ns) and mean blood pressure (+4.3, +6.4, -0.5 mmHg, p < 0.01, < 0.01, ns), as well as peripheral resistance (+212, +253, -4 dyne.sec.cm-5, p < 0.05, < 0.05, ns). The stroke volume showed a non-statistically-significant inverse trend (-3.1, -5.2, -0.2 ml). 18 hypotension episodes were recorded during the course of the study. 72% with K-1, 11% with K and 17% with K+1 (p < 0.01 for comparison K-1 vs. K and K-1 vs. K+1). CONCLUSIONS: A rapid decrease in the concentration of serum potassium during the initial stage of the dialysis-obtained by reducing the concentration of potassium in the dialysate-translated into a decrease of systolic and mean blood pressure mediated by a decrease in peripheral resistance. The risk of intra-dialysis hypotension inversely correlates to the potassium concentration in the dialysate. TRIAL REGISTRATION NUMBER: NCT01224314.
Resumo:
The pathophysiological role of an increase in circulating vasopressin in sustaining global and regional vasoconstriction in patients with congestive heart failure has not been established, particularly in patients with hyponatraemia. To assess this further, 20 patients with congestive heart failure refractory to digoxin and diuretics were studied before and 60 minutes after the intravenous injection (5 micrograms/kg) of the vascular antagonist of vasopressin [1(beta-mercapto-beta,beta-cyclopentamethylene-propionic acid), 2-(0-methyl) tyrosine] arginine vasopressin. Ten patients were hyponatraemic (plasma sodium less than 135 mmol/l) and 10 were normonatraemic. In both groups of patients the vascular vasopressin antagonist did not alter systemic or pulmonary artery pressures, right atrial pressure, pulmonary capillary wedge pressure, cardiac index, or vascular resistances. Furthermore, there was no change in skin and hepatic blood flow in either group after the injection of the vascular antagonist. Only one patient in the hyponatraemic group showed considerable haemodynamic improvement. He had severe congestive heart failure and a high concentration of plasma vasopressin (51 pmol/l). Plasma renin activity, vasopressin, or catecholamine concentrations were not significantly changed in response to the administration of the vasopressin antagonist in either the hyponatraemic or the normonatraemic groups. Patients with hyponatraemia, however, had higher baseline plasma catecholamine concentrations, heart rate, pulmonary pressure and resistance, and lower hepatic blood flow than patients without hyponatraemia. Plasma vasopressin and plasma renin activity were slightly, though not significantly, higher in the hyponatraemic group. Thus the role of vasopressin in sustaining regional or global vasoconstriction seems limited in patients with congestive heart failure whether or not concomitant hyponatraemia is present. Vasopressin significantly increases the vascular tone only in rare patients with severe congestive heart failure and considerably increased vasopressin concentrations. Patients with hyponatraemia do, however, have raised baseline catecholamine concentrations, heart rate, pulmonary arterial pressure and resistance, and decreased hepatic blood flow.
Resumo:
While the lesions produced by transmyocardial laser revascularisation (TMLR) induce scar formation, it is important to determine whether this procedure can be deleterious for the left-ventricular function, which is already impaired by the underlying ischaemic process in some patients. Ten channels were drilled in the left lateral wall of the hearts of ten pigs (mean weight, 61 +/- 8.2kg) with a Holmium:YAG laser. Haemodynamic measurements and echocardiographic assessment of left-ventricular function were performed before the TMLR procedure, 5 and 30 min after, and lastly after 5 min of pacing at a rate increased by 30% of the baseline value. Echocardiographic assessment was in the short axis at the level of the laser channels, and included left-ventricular ejection fraction and segmental wall motility of the lasered area (scale 0-3:0 = normal 1 = hypokinesia, 2 = akinesia, 3 = dyskinesia). Values at 5 and 30 min were compared with baseline values; the difference was considered significant if p < 0.05. Haemodynamical values were stable throughout all the procedures. The ejection fraction showed a slight but significant decrease 5 min after the creation of the channels (60.4 +/- 6.8% vs 54 +/- 7.6%, p=0.02) and recovered at 30min. The segmental motility score of the involved areas increased to 1 after 5 min in five animals, and came back to 0 at 30 min except in one animal. Even with pacing no segmental dysfunction occurred. The reversibility of the segmental hypokinesia induced by TMLR, as well as the absence of pace-induced dysfunction 30 min after the procedure strongly suggest the inocuity of TMLR in this experimental set-up.
Resumo:
BACKGROUND: In a previous study we demonstrated that mild metabolic alkalosis resulting from standard bicarbonate haemodialysis induces hypotension. In this study, we have further investigated the changes in systemic haemodynamics induced by bicarbonate and calcium, using non-invasive procedures. METHODS: In a randomized controlled trial with a single-blind, crossover design, we sequentially changed the dialysate bicarbonate and calcium concentrations (between 26 and 35 mmol/l for bicarbonate and either 1.25 or 1.50 mmol/l for calcium). Twenty-one patients were enrolled for a total of 756 dialysis sessions. Systemic haemodynamics was evaluated using pulse wave analysers. Bioimpedance and BNP were used to compare the fluid status pattern. RESULTS: The haemodynamic parameters and the pre-dialysis BNP using either a high calcium or bicarbonate concentration were as follows: systolic blood pressure (+5.6 and -4.7 mmHg; P < 0.05 for both), stroke volume (+12.3 and +5.2 ml; P < 0.05 and ns), peripheral resistances (-190 and -171 dyne s cm(-5); P < 0.05 for both), central augmentation index (+1.1% and -2.9%; ns and P < 0.05) and BNP (-5 and -170 ng/l; ns and P < 0.05). The need of staff intervention was similar in all modalities. CONCLUSIONS: Both high bicarbonate and calcium concentrations in the dialysate improve the haemodynamic pattern during dialysis. Bicarbonate reduces arterial stiffness and ameliorates the heart tolerance for volume overload in the interdialytic phase, whereas calcium directly increases stroke volume. The slight hypotensive effect of alkalaemia should motivate a probative reduction of bicarbonate concentration in dialysis fluid for haemodynamic reasons, only in the event of failure of classical tools to prevent intradialytic hypotension.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
The effect of vasopressin released during Finnish sauna on blood pressure, heart rate and skin blood flow was investigated in 12 healthy volunteers. Exposure to the hot air decrease body weight by 0.6 to 1.25 kg (mean = 0.8 kg, P less than 0.001). One hour after the end of the sauna sessions, plasma vasopressin was higher (1.7 +/- 0.2 pg/ml, P less than 0.01 mean +/- SEM) than before the sauna (1.0 +/- 0.1 pg/ml). No simultaneous change in plasma osmolality, plasma renin activity, plasma norepinephrine, epinephrine, cortisol, aldosterone, beta-endorphin and metenkephalin levels was observed. Despite the slight sauna-induced elevation in circulating vasopressin, intravenous injection of the specific vascular vasopressin antagonist d(CH2)5Tyr(Me)AVP (5 micrograms/kg) 1 h after the sauna had no effect on blood pressure, heart rate or skin blood flow. These data suggest that vasopressin released into the circulation during a sauna session reaches concentrations which are not high enough to interfere directly with vascular tone.