998 resultados para general device


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Haptic information, provided by a non-rigid tool (i.e., an anchor system), can reduce body sway in individuals who perform a standing postural task. However, it was not known whether or not continuous use of the anchor system would improve postural control after its removal. Additionally, it was unclear as to whether or not frequency of use of the anchor system is related to improved control in older adults. The present study evaluated the effect of the prolonged use of the anchor system on postural control in healthy older individuals, at different frequencies of use, while they performed a postural control task (semi-tandem position). Participants were divided into three groups according to the frequency of the anchor system's use (0%, 50%, and 100%). Pre-practice phase (without anchor) was followed by a practice phase (they used the anchor system at the predefined frequency), and a post-practice phase (immediate and late-without anchor). All three groups showed a persistent effect 15. min after the end of the practice phase (immediate post-practice phase). However, only the 50% group showed a persistent effect in the late post-practice phase (24. h after finishing the practice phase). Older adults can improve their postural control by practicing the standing postural task, and use of the anchor system limited to half of their practice time can provide additional improvement in their postural control. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Cardiovascular diseases (CVD) are the main cause of death and disability in developed countries. In most cases, the progress of CVD is influenced by environmental factors and multifactorial inheritance. The purpose of this study was to investigate the association between APOE genotypes, cardiovascular risk factors, and a noninvasive measure of arterial stiffness in the Brazilian population. Methods: A total of 1493 urban Brazilian individuals were randomly selected from the general population of the Vitoria City Metropolitan area. Genetic analysis of the APOE polymorphism was conducted by PCR-RFLP and pulse wave velocity analyzed with a noninvasive automatic device. Results: Age, gender, body mass index, triglycerides, creatinine, uric acid, blood glucose, blood pressure phenotypes were no different between epsilon 2, epsilon 3 and epsilon 4 alleles. The epsilon 4 allele was associated with higher total-cholesterol (p < 0.001), LDL-C (p < 0.001), total-cholesterol/HDL-C ratio (p < 0.001), LDL/HDL-C ratio (p < 0.001), lower HDL-C values (p < 0.001) and higher risk to obesity (OR = 1.358, 95% CI = 1.019-1.811) and hyperuricemia (OR = 1.748, 95% CI = 1.170-2.611). Nevertheless, pulse wave velocity (p = 0.66) measures were no different between genotypes. The significant association between APOE genotypes and lipid levels persisted after a 5-year follow-up interval, but no interaction between time and genotype was observed for lipids longitudinal behavior. Conclusion: The epsilon 4 allele of the APOE gene is associated with a worse lipid profile in the Brazilian urban population. In our relatively young sample, the observed effect of APOE genotype on lipid levels was not translated into significant effects in arterial wall stiffness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. This study is an evaluation of the vacuum-assisted closure (VAC) therapy for the treatment of severe intrathoracic infections complicating lung resection, esophageal surgery, viscera perforation, or necrotizing pleuropulmonary infections.Methods. We reviewed the medical records of all patients treated by intrathoracic VAC therapy between January 2005 and December 2008. All patients underwent surgical debridement-decortication and control of the underlying cause of infection such as treatment of bronchus stump insufficiency, resection of necrotic lung, or closure of esophageal or intestinal leaks. Surgery was followed by intrathoracic VAC therapy until the infection was controlled. The VAC dressings were changed under general anesthesia and the chest wall was temporarily closed after each dressing change. All patients received systemic antibiotic therapy.Results. Twenty-seven patients (15 male, median age 64 years) underwent intrathoracic VAC dressings for the management of postresectional empyema (n = 8) with and without bronchopleural fistula, necrotizing infections (n = 7), and intrathoracic gastrointestinal leaks (n = 12). The median length of VAC therapy was 22 days (range 5 to 66) and the median number of VAC changes per patient was 6 (range 2 to 16). In-hospital mortality was 19% (n = 5) and was not related to VAC therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in all surviving patients.Conclusions. Vacuum-assisted closure therapy is an efficient and safe adjunct to treat severe intrathoracic infections and may be a good alternative to the open window thoracostomy in selected patients. Long time intervals in between VAC changes and short course of therapy result in good patient acceptance. (Ann Thorac Surg 2011;91:1582-90) (C) 2011 by The Society of Thoracic Surgeons

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate diagnosis of orthopedic device-associated infections can be challenging. Culture of tissue biopsy specimens is often considered the gold standard; however, there is currently no consensus on the ideal incubation time for specimens. The aim of our study was to assess the yield of a 14-day incubation protocol for tissue biopsy specimens from revision surgery (joint replacements and internal fixation devices) in a general orthopedic and trauma surgery setting. Medical records were reviewed retrospectively in order to identify cases of infection according to predefined diagnostic criteria. From August 2009 to March 2012, 499 tissue biopsy specimens were sampled from 117 cases. In 70 cases (59.8%), at least one sample showed microbiological growth. Among them, 58 cases (82.9%) were considered infections and 12 cases (17.1%) were classified as contaminations. The median time to positivity in the cases of infection was 1 day (range, 1 to 10 days), compared to 6 days (range, 1 to 11 days) in the cases of contamination (P < 0.001). Fifty-six (96.6%) of the infection cases were diagnosed within 7 days of incubation. In conclusion, the results of our study show that the incubation of tissue biopsy specimens beyond 7 days is not productive in a general orthopedic and trauma surgery setting. Prolonged 14-day incubation might be of interest in particular situations, however, in which the prevalence of slow-growing microorganisms and anaerobes is higher.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CORBA (Common Object Request Broker Architecture) on laajalle levinnyt ja teollisuudessa yleisesti käytetty hajautetun tietojenkäsittelyn arkkitehtuuri. CORBA skaalautuu eri kokoisiin tarpeisiin ja sitä voidaan hyödynntää myös sulautetuissa langattomissa laitteissa. Oleellista sulautetussa ympäristössä on rakentaa rajapinnat kevytrakenteisiksi, pysyviksi ja helposti laajennettaviksi ilman että yhteensopivuus aikaisempiin rajapintoihin olisi vaarassa. Langattomissa laitteissa resurssit, kuten muistin määrä ja prosessointiteho, ovat hyvin rajalliset, joten rajapinta tulee suunnitella ja toteuttaa optimaalisesti. Palveluiden tulee ottaa huomioon myös langattomuuden rajoitukset, kuten hitaat tiedonsiirtonopeudet ja tiedonsiirron yhteydettömän luonteen. Työssä suunniteltiin ja toteutettiin CORBA-rajapinta GSM-päätelaitteeseen, jonka on todettu täyttävän sille asetetut tavoitteet. Rajapinta tarjoaa kaikki yleisimmät GSM-terminaalin ominaisuudet ja on laajennettavissa tulevia tuotteita ja verkkotekniikoita varten. Laajennettavuutta saavutetaan esimerkiksi kuvaamalla terminaalin ominaisuudet yleisellä kuvauskielellä, kuten XML:lla (Extensible Markup Language).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The purpose of this study is to validate the Pulvers silhouette showcard as a measure of weight status in a population in the African region. This tool is particularly beneficial when scarce resources do not allow for direct anthropometric measurements due to limited survey time or lack of measurement technology in face-to-face general-purpose surveys or in mailed, online, or mobile device-based surveys. METHODS: A cross-sectional study was conducted in the Republic of Seychelles with a sample of 1240 adults. We compared self-reported body sizes measured by Pulvers' silhouette showcards to four measurements of body size and adiposity: body mass index (BMI), body fat percent measured, waist circumference, and waist to height ratio. The accuracy of silhouettes as an obesity indicator was examined using sex-specific receiver operator curve (ROC) analysis and the reliability of this tool to detect socioeconomic gradients in obesity was compared to BMI-based measurements. RESULTS: Our study supports silhouette body size showcards as a valid and reliable survey tool to measure self-reported body size and adiposity in an African population. The mean correlation coefficients of self-reported silhouettes with measured BMI were 0.80 in men and 0.81 in women (P < 0.001). The silhouette showcards also showed high accuracy for detecting obesity as per a BMI ≥ 30 (Area under curve, AUC: 0.91/0.89, SE: 0.01), which was comparable to other measured adiposity indicators: fat percent (AUC: 0.94/0.94, SE: 0.01), waist circumference (AUC: 0.95/0.94, SE: 0.01), and waist to height ratio (AUC: 0.95/0.94, SE: 0.01) amongst men and women, respectively. The use of silhouettes in detecting obesity differences among different socioeconomic groups resulted in similar magnitude, direction, and significance of association between obesity and socioeconomic status as when using measured BMI. CONCLUSIONS: This study highlights the validity and reliability of silhouettes as a survey tool for measuring obesity in a population in the African region. The ease of use and cost-effectiveness of this tool makes it an attractive alternative to measured BMI in the design of non-face-to-face online- or mobile device-based surveys as well as in-person general-purpose surveys of obesity in social sciences, where limited resources do not allow for direct anthropometric measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

General-purpose computing devices allow us to (1) customize computation after fabrication and (2) conserve area by reusing expensive active circuitry for different functions in time. We define RP-space, a restricted domain of the general-purpose architectural space focussed on reconfigurable computing architectures. Two dominant features differentiate reconfigurable from special-purpose architectures and account for most of the area overhead associated with RP devices: (1) instructions which tell the device how to behave, and (2) flexible interconnect which supports task dependent dataflow between operations. We can characterize RP-space by the allocation and structure of these resources and compare the efficiencies of architectural points across broad application characteristics. Conventional FPGAs fall at one extreme end of this space and their efficiency ranges over two orders of magnitude across the space of application characteristics. Understanding RP-space and its consequences allows us to pick the best architecture for a task and to search for more robust design points in the space. Our DPGA, a fine- grained computing device which adds small, on-chip instruction memories to FPGAs is one such design point. For typical logic applications and finite- state machines, a DPGA can implement tasks in one-third the area of a traditional FPGA. TSFPGA, a variant of the DPGA which focuses on heavily time-switched interconnect, achieves circuit densities close to the DPGA, while reducing typical physical mapping times from hours to seconds. Rigid, fabrication-time organization of instruction resources significantly narrows the range of efficiency for conventional architectures. To avoid this performance brittleness, we developed MATRIX, the first architecture to defer the binding of instruction resources until run-time, allowing the application to organize resources according to its needs. Our focus MATRIX design point is based on an array of 8-bit ALU and register-file building blocks interconnected via a byte-wide network. With today's silicon, a single chip MATRIX array can deliver over 10 Gop/s (8-bit ops). On sample image processing tasks, we show that MATRIX yields 10-20x the computational density of conventional processors. Understanding the cost structure of RP-space helps us identify these intermediate architectural points and may provide useful insight more broadly in guiding our continual search for robust and efficient general-purpose computing structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This RTD project, 2007-2009, is partly funded by the European Commission, in Framework Programme 6. It aims to assist elderly people for living well, independently and at case. ENABLE will provide a number of services for elderly people based on the new technology provided by mobile phones. The project is developing a Wrist unit with both integrated and external sensors, and with a radio frequency link to a mobile phone. Dedicated ENABLE software running on the wrist unit and mobile phone makes these services fully accessible for the elderly users. This paper outlines the fundamental motivation and the approach which currently is undertaken in order to collect the more detailed user needs and requirements. The general architecture and the design of the ENABLE system are outlined.