997 resultados para gas entrainment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Gas entrainment, indicated by visual bubbles in the mercury, led to low heat transfer rates which were increased by increasing the static pressure. Suitable changes in the flow system resulted in a reduction of this entrainment effect and an increase in heat transfer performance."--Page iii.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Modeling study is performed to reveal the special features of the entrainment of ambient air into subsonic laminar and turbulent argon plasma jets. Two different types of jet flows are considered, i.e., the argon plasma jet is impinging normally upon a flat substrate located in atmospheric air surroundings or is freely issuing into the ambient air. It is found that the existence of the substrate not only changes the plasma temperature, velocity and species concentration distributions in the near-substrate region, but also significantly enhances the mass flow rate of the ambient air entrained into the jet due to the additional contribution to the gas entrainment of the wall jet formed along the substrate surface. The fraction of the additional entrainment of the wall jet in the total entrained-air flow rate is especially high for the laminar impinging plasma jet and for the case with shorter substrate standoff distances. Similarly to the case of cold-gas free jets, the maximum mass flow-rate of ambient gas entrained into the turbulent impinging or free plasma jet is approximately directly proportional to the mass flow rate at the jet inlet. The maximum mass flow-rate of ambient gas entrained into the laminar impinging plasma jet slightly increases with increasing jet-inlet velocity but decreases with increasing jet-inlet temperature.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Silent and stable long laminar plasma jets can be generated in a rather wide range of working parameters. The laminar flow state can be maintained even if considerable parameter fluctuations exist in the laminar plasma jet or if there is an impact of laterally injected particulate matter and its carrier gas. The attractive special features of laminar plasma jets include extremely low noise level, less entrainment of ambient air, much longer and adjustable high-temperature region length, and smaller axial gradient of plasma parameters. Modeling results show that the laminar plasma jet length increases with increasing jet inlet velocity or temperature and the effect of natural convection on laminar plasma jet characteristics can be ignored, consistent with experimental observations. The large difference between laminar and turbulent plasma jet characteristics is revealed to be due to their different laws of surrounding gas entrainment. Besides the promising applications of the laminar plasma jet to remelting and cladding strengthening of the metallic surface and to thermal barrier coating preparation, it is expected that the laminar plasma jet can become a rather ideal object for the basic studies of thermal plasma science owing to the nonexistence of the complexity caused by turbulence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Silent and stable long laminar plasma jets can be generated in a rather wide range of working parameters. The laminar flow state can be maintained even if considerable parameter fluctuations exist in the laminar plasma jet or if there is an impact of laterally injected particulate matter and its carrier gas. The attractive special features of laminar plasma jets include extremely low noise level, less entrainment of ambient air, much longer and adjustable high-temperature region length, and smaller axial gradient of plasma parameters. Modeling results show that the laminar plasma jet length increases with increasing jet inlet velocity or temperature and the effect of natural convection on laminar plasma jet characteristics can be ignored, consistent with experimental observations. The large difference between laminar and turbulent plasma jet characteristics is revealed to be due to their different laws of surrounding gas entrainment. Besides the promising applications of the laminar plasma jet to remelting and cladding strengthening of the metallic surface and to thermal barrier coating preparation, it is expected that the laminar plasma jet can become a rather ideal object for the basic studies of thermal plasma science owing to the nonexistence of the complexity caused by turbulence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

TiAl castings are prone to various defects including bubbles entrained during the turbulent filling of moulds. The present research has exploited the principles of the Durville tilt casting technique to develop a novel process in which the Induction Skull Melting (ISM) of TiAl alloys in a vacuum chamber has been combined with controlled tilt pouring to achieve the tranquil transfer of the metal into a hot ceramic shell mould. Practical casting equipment has been developed to evaluate the feasibility of this process in parallel with the development of novel software to simulate and optimize it. The PHYSICA CFD code was used to simulate the filling, heat transfer and solidification during tilt pouring using a number of free surface modelling techniques, including the novel Counter Diffusion Method (CDM). In view of the limited superheat, particular attention was paid to the mould design to minimize heat loss and gas entrainment caused by interaction between the counter-flowing metal and gas streams. The model has been validated against real-time X-ray movies of the tilt casting of aluminium and against TiAl blade castings. Modelling has contributed to designing a mould to promote progressive filling of the casting and has led to the use of a parabolic tilting cycle to balance the competing requirements for rapid filling to minimize the loss of superheat and slow filling minimize the turbulence-induced defects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A dilution cum purge ejector for application in fuel cells represents a domain of ejector operation involving low entrainment ratio with differing secondary and primary gas; which is hardly investigated and a cohesive design framework is not readily available. We comprehensively study a constant area ejector using analytical, experimental and numerical tools at low entrainment ratio (0.004-0.065) with Air, Helium and Argon as secondary gas while the primary gas is Air. For the first time, limits of operating parameters used in control volume method to design the ejector are found to be highly dependent on the secondary molecular weight. The entrainment ratio in the ejector (low for Helium and high for Argon) is affected by the molecular weight and the static pressure within the ejector (low for Air and high for Argon & Helium) by the gamma of the secondary gas. Sufficient suction pressure (0.3-0.55 bar) is generated by the ejector thereby preventing any backflow of secondary gas at all primary stagnation pressures (1.5, 2.2 and 3.1 bar). Numerical results agree well with experimental results. The ejector is shown to completely dilute and purge the secondary flow, meeting all key design requirements. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study deals with the breakup behavior of swirling liquid sheets discharging from gas-centered swirl coaxial atomizers with attention focused toward the understanding of the role of central gas jet on the liquid sheet breakup. Cold flow experiments on the liquid sheet breakup were carried out by employing custom fabricated gas-centered swirl coaxial atomizers using water and air as experimental fluids. Photographic techniques were employed to capture the flow behavior of liquid sheets at different flow conditions. Quantitative variation on the breakup length of the liquid sheet and spray width were obtained from the measurements deduced from the images of liquid sheets. The sheet breakup process is significantly influenced by the central air jet. It is observed that low inertia liquid sheets are more vulnerable to the presence of the central air jet and develop shorter breakup lengths at smaller values of the air jet Reynolds number Re-g. High inertia liquid sheets ignore the presence of the central air jet at smaller values of Re-g and eventually develop shorter breakup lengths at higher values of Re-g. The experimental evidences suggest that the central air jet causes corrugations on the liquid sheet surface, which may be promoting the production of thick liquid ligaments from the sheet surface. The level of surface corrugations on the liquid sheet increases with increasing Re-g. Qualitative analysis of experimental observations reveals that the entrainment process of air established between the inner surface of the liquid sheet and the central air jet is the primary trigger for the sheet breakup.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When materials processing is conducted in air surroundings by use of an impinging plasma jet, the ambient air will be entrained into the materials processing region, resulting in unfavorable oxidation of the feedstock metal particles injected into the plasma jet and of metallic substrate material. Using a cylindrical solid shield may avoid the air entrainment if the shield length is suitably selected and this approach has the merit that expensive vacuum chamber and its pumping system are not needed. Modeling study is thus conducted to reveal how the length of the cylindrical solid shield affects the ambient air entrainment when materials processing (spraying, remelting, hardening, etc.) is conducted by use of a turbulent or laminar argon plasma jet impinging normally upon a flat substrate in atmospheric air. It is shown that the mass flow rate of the ambient air entrained into the impinging plasma jet cannot be appreciably reduced unless the cylindrical shield is long enough. In order to completely avoid the air entrainment, the gap between the downstream-end section of the cylindrical solid shield and the substrate surface must be carefully selected, and the suitable size of the gap for the turbulent plasma jet is appreciably larger than that for the laminar one. The overheating of the solid shield or the substrate could become a problem for the turbulent case, and thus additional cooling measure may be needed when the entrainment of ambient air into the turbulent impinging plasma jet is to be completely avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the laminar plasma materials processing as the research background, modeling study is conducted concerning the effects of argon shroud on the characteristics of the laminar argon plasma jet impinging normally upon a flat substrate located in air surroundings. It is shown that adding shrouding gas is an effective method to reduce and control the entrainment of ambient air into the laminar plasma jet. The shrouding gas flow rate or velocity, the injection slot width and the stand-off distance of the substrate appreciably affect the air contents in the plasma near the substrate surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The entrainment rate of ambient gas into a turbulent argon plasma jet generated by plasma torch is directly measured using a “porous-wall chamber” technique. It is shown that with the increase of the mass flow rates of argon at the jet inlet, the mass flow rate of entrained gas increases. The normalized mass flow rate decreases with the increasing inlet mass flow rates of plasma torch. The entrained gas mass flow rate increases with increasing chamber length, but less depends on the arc current of the plasma torch at higher flow rates. The effects of different ways of inflowing gas into plasma torch on entrainment characteristics of plasma jet are also examined in this paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the major problems in the operations of mammalian cell bioreactors is the detrimental effect of gas sparging. Since the most convenient way to oxygenate any bioreactor is by gas sparging, this adverse effect has often been one of the limiting oxygen transport problems in both laboratory and industrial mammalian cell bioreactors. When one examines the literature on the effect of gas sparging on the death of mammalian cells, a great deal of confusions has been reported. It is not clear from the published literature as to the leading cause for gas-sparged related cell death. These confusions prevent the rational design and operations of mammalian cell bioreactors. In our laboratory, we have attempted to address this problem both fundamentally as well as attempt to obtain a general understanding on the adverse effect of gas sparging. Our analyses first examined the fluid shear associated with the various sections that the gas bubbles encounter during entrance, passage through the bioreactor and the final exit of the gas bubbles. Our analyses showed that the major damage of the mammalian cells by gas bubbles is due to the burst of the bubbles when exiting the bioreactor. It was also our hypothesis that the entrained cells in the liquid boundary layer of the gas bubble upon bursting is the major cause for cell death. We have corroborated this hypothesis by correlating the liquid entrainment with the cell death rate using results from our laboratory as well as other studies. Pluonic F-68, a weak surfactant, has routinely been used in laboratory and industrial bioreactors. In the past, the protective effect of Pluronic F-68 has never been shown as to why it is effective. In our research, we have data using microphotography which clearly demonstrated and corroborated our entrainment hypothesis is the major reason for the effectiveness of Pluronic F-68 in protecting the cells from gas-sparged related cell death.