880 resultados para frequency limitation
Resumo:
The influence of radio frequency (rf) power and pressure on deposition rate and structural properties of hydrogenated amorphous silicon (a-Si:H) thin films, prepared by rf glow discharge decomposition of silane, have been studied by phase modulated ellipsometry and Fourier transform infrared spectroscopy. It has been found two pressure regions separated by a threshold value around 20 Pa where the deposition rate increases suddenly. This behavior is more marked as rf power rises and reflects the transition between two rf discharges regimes. The best quality films have been obtained at low pressure and at low rf power but with deposition rates below 0.2 nm/s. In the high pressure region, the enhancement of deposition rate as rf power increases first gives rise to a reduction of film density and an increase of content of hydrogen bonded in polyhydride form because of plasma polymerization reactions. Further rise of rf power leads to a decrease of polyhydride bonding and the material density remains unchanged, thus allowing the growth of a-Si:H films at deposition rates above 1 nm/s without any important detriment of material quality. This overcoming of deposition rate limitation has been ascribed to the beneficial effects of ion bombardment on the a-Si:H growing surface by enhancing the surface mobility of adsorbed reactive species and by eliminating hydrogen bonded in polyhydride configurations.
Resumo:
This correspondence studies the formulation of members ofthe Cohen-Posch class of positive time-frequency energy distributions.Minimization of cross-entropy measures with respect to different priorsand the case of no prior or maximum entropy were considered. It isconcluded that, in general, the information provided by the classicalmarginal constraints is very limited, and thus, the final distributionheavily depends on the prior distribution. To overcome this limitation,joint time and frequency marginals are derived based on a "directioninvariance" criterion on the time-frequency plane that are directly relatedto the fractional Fourier transform.
Resumo:
Models developed to identify the rates and origins of nutrient export from land to stream require an accurate assessment of the nutrient load present in the water body in order to calibrate model parameters and structure. These data are rarely available at a representative scale and in an appropriate chemical form except in research catchments. Observational errors associated with nutrient load estimates based on these data lead to a high degree of uncertainty in modelling and nutrient budgeting studies. Here, daily paired instantaneous P and flow data for 17 UK research catchments covering a total of 39 water years (WY) have been used to explore the nature and extent of the observational error associated with nutrient flux estimates based on partial fractions and infrequent sampling. The daily records were artificially decimated to create 7 stratified sampling records, 7 weekly records, and 30 monthly records from each WY and catchment. These were used to evaluate the impact of sampling frequency on load estimate uncertainty. The analysis underlines the high uncertainty of load estimates based on monthly data and individual P fractions rather than total P. Catchments with a high baseflow index and/or low population density were found to return a lower RMSE on load estimates when sampled infrequently than those with a tow baseflow index and high population density. Catchment size was not shown to be important, though a limitation of this study is that daily records may fail to capture the full range of P export behaviour in smaller catchments with flashy hydrographs, leading to an underestimate of uncertainty in Load estimates for such catchments. Further analysis of sub-daily records is needed to investigate this fully. Here, recommendations are given on load estimation methodologies for different catchment types sampled at different frequencies, and the ways in which this analysis can be used to identify observational error and uncertainty for model calibration and nutrient budgeting studies. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
El requerimiento de proveer alta frecuencia de datos en los modernos sistema de comunicación inalámbricos resulta en complejas señales moduladas de radio-frequencia (RF) con un gran ancho de banda y alto ratio pico-promedio (PAPR). Para garantizar la linealidad del comportamiento, los amplificadores lineales de potencia comunes funcionan típicamente entre 4 y 10 dB de back-o_ desde la máxima potencia de salida, ocasionando una baja eficiencia del sistema. La eliminación y restauración de la evolvente (EER) y el seguimiento de la evolvente (ET) son dos prometedoras técnicas para resolver el problema de la eficiencia. Tanto en EER como en ET, es complicado diseñar un amplificador de potencia que sea eficiente para señales de RF de alto ancho de banda y alto PAPR. Una propuesta común para los amplificadores de potencia es incluir un convertidor de potencia de muy alta eficiencia operando a frecuencias más altas que el ancho de banda de la señal RF. En este caso, la potencia perdida del convertidor ocasionado por la alta frecuencia desaconseja su práctica cuando el ancho de banda es muy alto. La solución a este problema es el enfoque de esta disertación que presenta dos arquitecturas de amplificador evolvente: convertidor híbrido-serie con una técnica de evolvente lenta y un convertidor multinivel basado en un convertidor reductor multifase con control de tiempo mínimo. En la primera arquitectura, una topología híbrida está compuesta de una convertidor reductor conmutado y un regulador lineal en serie que trabajan juntos para ajustar la tensión de salida para seguir a la evolvente con precisión. Un algoritmo de generación de una evolvente lenta crea una forma de onda con una pendiente limitada que es menor que la pendiente máxima de la evolvente original. La salida del convertidor reductor sigue esa forma de onda en vez de la evolvente original usando una menor frecuencia de conmutación, porque la forma de onda no sólo tiene una pendiente reducida sino también un menor ancho de banda. De esta forma, el regulador lineal se usa para filtrar la forma de onda tiene una pérdida de potencia adicional. Dependiendo de cuánto se puede reducir la pendiente de la evolvente para producir la forma de onda, existe un trade-off entre la pérdida de potencia del convertidor reductor relacionada con la frecuencia de conmutación y el regulador lineal. El punto óptimo referido a la menor pérdida de potencia total del amplificador de evolvente es capaz de identificarse con la ayuda de modelo preciso de pérdidas que es una combinación de modelos comportamentales y analíticos de pérdidas. Además, se analiza el efecto en la respuesta del filtro de salida del convertidor reductor. Un filtro de dampeo paralelo extra es necesario para eliminar la oscilación resonante del filtro de salida porque el convertidor reductor opera en lazo abierto. La segunda arquitectura es un amplificador de evolvente de seguimiento de tensión multinivel. Al contrario que los convertidores que usan multi-fuentes, un convertidor reductor multifase se emplea para generar la tensión multinivel. En régimen permanente, el convertidor reductor opera en puntos del ciclo de trabajo con cancelación completa del rizado. El número de niveles de tensión es igual al número de fases de acuerdo a las características del entrelazamiento del convertidor reductor. En la transición, un control de tiempo mínimo (MTC) para convertidores multifase es novedosamente propuesto y desarrollado para cambiar la tensión de salida del convertidor reductor entre diferentes niveles. A diferencia de controles convencionales de tiempo mínimo para convertidores multifase con inductancia equivalente, el propuesto MTC considera el rizado de corriente por cada fase basado en un desfase fijo que resulta en diferentes esquemas de control entre las fases. La ventaja de este control es que todas las corrientes vuelven a su fase en régimen permanente después de la transición para que la siguiente transición pueda empezar muy pronto, lo que es muy favorable para la aplicación de seguimiento de tensión multinivel. Además, el control es independiente de la carga y no es afectado por corrientes de fase desbalanceadas. Al igual que en la primera arquitectura, hay una etapa lineal con la misma función, conectada en serie con el convertidor reductor multifase. Dado que tanto el régimen permanente como el estado de transición del convertidor no están fuertemente relacionados con la frecuencia de conmutación, la frecuencia de conmutación puede ser reducida para el alto ancho de banda de la evolvente, la cual es la principal consideración de esta arquitectura. La optimización de la segunda arquitectura para más alto anchos de banda de la evolvente es presentada incluyendo el diseño del filtro de salida, la frecuencia de conmutación y el número de fases. El área de diseño del filtro está restringido por la transición rápida y el mínimo pulso del hardware. La rápida transición necesita un filtro pequeño pero la limitación del pulso mínimo del hardware lleva el diseño en el sentido contrario. La frecuencia de conmutación del convertidor afecta principalmente a la limitación del mínimo pulso y a las pérdidas de potencia. Con una menor frecuencia de conmutación, el ancho de pulso en la transición es más pequeño. El número de fases relativo a la aplicación específica puede ser optimizado en términos de la eficiencia global. Otro aspecto de la optimización es mejorar la estrategia de control. La transición permite seguir algunas partes de la evolvente que son más rápidas de lo que el hardware puede soportar al precio de complejidad. El nuevo método de sincronización de la transición incrementa la frecuencia de la transición, permitiendo que la tensión multinivel esté más cerca de la evolvente. Ambas estrategias permiten que el convertidor pueda seguir una evolvente con un ancho de banda más alto que la limitación de la etapa de potencia. El modelo de pérdidas del amplificador de evolvente se ha detallado y validado mediante medidas. El mecanismo de pérdidas de potencia del convertidor reductor tiene que incluir las transiciones en tiempo real, lo cual es diferente del clásico modelos de pérdidas de un convertidor reductor síncrono. Este modelo estima la eficiencia del sistema y juega un papel muy importante en el proceso de optimización. Finalmente, la segunda arquitectura del amplificador de evolvente se integra con el amplificador de clase F. La medida del sistema EER prueba el ahorro de energía con el amplificador de evolvente propuesto sin perjudicar la linealidad del sistema. ABSTRACT The requirement of delivering high data rates in modern wireless communication systems results in complex modulated RF signals with wide bandwidth and high peak-to-average ratio (PAPR). In order to guarantee the linearity performance, the conventional linear power amplifiers typically work at 4 to 10 dB back-off from the maximum output power, leading to low system efficiency. The envelope elimination and restoration (EER) and envelope tracking (ET) are two promising techniques to overcome the efficiency problem. In both EER and ET, it is challenging to design efficient envelope amplifier for wide bandwidth and high PAPR RF signals. An usual approach for envelope amplifier includes a high-efficiency switching power converter operating at a frequency higher than the RF signal's bandwidth. In this case, the power loss of converter caused by high switching operation becomes unbearable for system efficiency when signal bandwidth is very wide. The solution of this problem is the focus of this dissertation that presents two architectures of envelope amplifier: a hybrid series converter with slow-envelope technique and a multilevel converter based on a multiphase buck converter with the minimum time control. In the first architecture, a hybrid topology is composed of a switched buck converter and a linear regulator in series that work together to adjust the output voltage to track the envelope with accuracy. A slow envelope generation algorithm yields a waveform with limited slew rate that is lower than the maximum slew rate of the original envelope. The buck converter's output follows this waveform instead of the original envelope using lower switching frequency, because the waveform has not only reduced slew rate but also reduced bandwidth. In this way, the linear regulator used to filter the waveform has additional power loss. Depending on how much reduction of the slew rate of envelope in order to obtain that waveform, there is a trade-off between the power loss of buck converter related to the switching frequency and the power loss of linear regulator. The optimal point referring to the lowest total power loss of this envelope amplifier is identified with the help of a precise power loss model that is a combination of behavioral and analytic loss model. In addition, the output filter's effect on the response is analyzed. An extra parallel damping filter is needed to eliminate the resonant oscillation of output filter L and C, because the buck converter operates in open loop. The second architecture is a multilevel voltage tracking envelope amplifier. Unlike the converters using multi-sources, a multiphase buck converter is employed to generate the multilevel voltage. In the steady state, the buck converter operates at complete ripple cancellation points of duty cycle. The number of the voltage levels is equal to the number of phases according the characteristics of interleaved buck converter. In the transition, a minimum time control (MTC) for multiphase converter is originally proposed and developed for changing the output voltage of buck converter between different levels. As opposed to conventional minimum time control for multiphase converter with equivalent inductance, the proposed MTC considers the current ripple of each phase based on the fixed phase shift resulting in different control schemes among the phases. The advantage of this control is that all the phase current return to the steady state after the transition so that the next transition can be triggered very soon, which is very favorable for the application of multilevel voltage tracking. Besides, the control is independent on the load condition and not affected by the unbalance of phase current. Like the first architecture, there is also a linear stage with the same function, connected in series with the multiphase buck converter. Since both steady state and transition state of the converter are not strongly related to the switching frequency, it can be reduced for wide bandwidth envelope which is the main consideration of this architecture. The optimization of the second architecture for wider bandwidth envelope is presented including the output filter design, switching frequency and the number of phases. The filter design area is restrained by fast transition and the minimum pulse of hardware. The fast transition needs small filter but the minimum pulse of hardware limitation pushes the filter in opposite way. The converter switching frequency mainly affects the minimum pulse limitation and the power loss. With lower switching frequency, the pulse width in the transition is smaller. The number of phases related to specific application can be optimized in terms of overall efficiency. Another aspect of optimization is improving control strategy. Transition shift allows tracking some parts of envelope that are faster than the hardware can support at the price of complexity. The new transition synchronization method increases the frequency of transition, allowing the multilevel voltage to be closer to the envelope. Both control strategies push the converter to track wider bandwidth envelope than the limitation of power stage. The power loss model of envelope amplifier is detailed and validated by measurements. The power loss mechanism of buck converter has to include the transitions in real time operation, which is different from classical power loss model of synchronous buck converter. This model estimates the system efficiency and play a very important role in optimization process. Finally, the second envelope amplifier architecture is integrated with a Class F amplifier. EER system measurement proves the power saving with the proposed envelope amplifier without disrupting the linearity performance.
Resumo:
The over-production of reactive oxygen species (ROS) can cause oxidative damage to a large number of molecules, including DNA, and has been associated with the pathogenesis of several disorders, such as diabetes mellitus (DM), dyslipidemia and periodontitis (PD). We hypothesise that the presence of these diseases could proportionally increase the DNA damage. The aim of this study was to assess the micronucleus frequency (MNF), as a biomarker for DNA damage, in individuals with type 2 DM, dyslipidemia and PD. One hundred and fifty patients were divided into five groups based upon diabetic, dyslipidemic and periodontal status (Group 1 - poor controlled DM with dyslipidemia and PD; Group 2 - well-controlled DM with dyslipidemia and PD; Group 3 - without DM with dyslipidemia and PD; Group 4 - without DM, without dyslipidemia and with PD; and Group 5 - without DM, dyslipidemia and PD). Blood analyses were carried out for fasting plasma glucose, HbA1c and lipid profile. Periodontal examinations were performed, and venous blood was collected and processed for micronucleus (MN) assay. The frequency of micronuclei was evaluated by cell culture cytokinesis-block MN assay. The general characteristics of each group were described by the mean and standard deviation and the data were submitted to the Mann-Whitney, Kruskal-Wallis, Multiple Logistic Regression and Spearman tests. The Groups 1, 2 and 3 were similarly dyslipidemic presenting increased levels of total cholesterol, low density lipoprotein cholesterol and triglycerides. Periodontal tissue destruction and local inflammation were significantly more severe in diabetics, particularly in Group 1. Frequency of bi-nucleated cells with MN and MNF, as well as nucleoplasmic bridges, were significantly higher for poor controlled diabetics with dyslipidemia and PD in comparison with those systemically healthy, even after adjusting for age, and considering Bonferroni's correction. Elevated frequency of micronuclei was found in patients affected by type 2 diabetes, dyslipidemia and PD. This result suggests that these three pathologies occurring simultaneously promote an additional role to produce DNA impairment. In addition, the micronuclei assay was useful as a biomarker for DNA damage in individuals with chronic degenerative diseases.
Resumo:
Mutations in the FGFR3 gene cause the phenotypic spectrum of FGFR3 chondrodysplasias ranging from lethal forms to the milder phenotype seen in hypochondroplasia (Hch). The p.N540K mutation in the FGFR3 gene occurs in ∼70% of individuals with Hch, and nearly 30% of individuals with the Hch phenotype have no mutations in the FGFR3, which suggests genetic heterogeneity. The identification of a severe case of Hch associated with the typical mutation c.1620C > A and the occurrence of a c.1150T > C change that resulted in a p.F384L in exon 10, together with the suspicion that this second change could be a modulator of the phenotype, prompted us to investigate this hypothesis in a cohort of patients. An analysis of 48 patients with FGFR3 chondrodysplasia phenotypes and 330 healthy (control) individuals revealed no significant difference in the frequency of the C allele at the c.1150 position (p = 0.34). One patient carrying the combination `pathogenic mutation plus the allelic variant c.1150T > C' had a typical achondroplasia (Ach) phenotype. In addition, three other patients with atypical phenotypes showed no association with the allelic variant. Together, these results do not support the hypothesis of a modulatory role for the c.1150T > C change in the FGFR3 gene.
Resumo:
Networks of Kuramoto oscillators with a positive correlation between the oscillators frequencies and the degree of their corresponding vertices exhibit so-called explosive synchronization behavior, which is now under intensive investigation. Here we study and discuss explosive synchronization in a situation that has not yet been considered, namely when only a part, typically a small part, of the vertices is subjected to a degree-frequency correlation. Our results show that in order to have explosive synchronization, it suffices to have degree-frequency correlations only for the hubs, the vertices with the highest degrees. Moreover, we show that a partial degree-frequency correlation does not only promotes but also allows explosive synchronization to happen in networks for which a full degree-frequency correlation would not allow it. We perform a mean-field analysis and our conclusions were corroborated by exhaustive numerical experiments for synthetic networks and also for the undirected and unweighed version of a typical benchmark biological network, namely the neural network of the worm Caenorhabditis elegans. The latter is an explicit example where partial degree-frequency correlation leads to explosive synchronization with hysteresis, in contrast with the fully correlated case, for which no explosive synchronization is observed.
Resumo:
Mechanically evoked reflexes have been postulated to be less sensitive to presynaptic inhibition (PSI) than the H-reflex. This has implications on investigations of spinal cord neurophysiology that are based on the T-reflex. Preceding studies have shown an enhanced effect of PSI on the H-reflex when a train of ~10 conditioning stimuli at 1 Hz was applied to the nerve of the antagonist muscle. The main questions to be addressed in the present study are if indeed T-reflexes are less sensitive to PSI and whether (and to what extent and by what possible mechanisms) the effect of low frequency conditioning, found previously for the H-reflex, can be reproduced on T-reflexes from the soleus muscle. We explored two different conditioning-to-test (C-T) intervals: 15 and 100 ms (corresponding to D1 and D2 inhibitions, respectively). Test stimuli consisted of either electrical pulses applied to the posterior tibial nerve to elicit H-reflexes or mechanical percussion to the Achilles tendon to elicit T-reflexes. The 1 Hz train of conditioning electrical stimuli delivered to the common peroneal nerve induced a stronger effect of PSI as compared to a single conditioning pulse, for both reflexes (T and H), regardless of C-T-intervals. Moreover, the conditioning train of pulses (with respect to a single conditioning pulse) was proportionally more effective for T-reflexes as compared to H-reflexes (irrespective of the C-T interval), which might be associated with the differential contingent of Ia afferents activated by mechanical and electrical test stimuli. A conceivable explanation for the enhanced PSI effect in response to a train of stimuli is the occurrence of homosynaptic depression at synapses on inhibitory interneurons interposed within the PSI pathway. The present results add to the discussion of the sensitivity of the stretch reflex pathway to PSI and its functional role.
Resumo:
Spinocerebellar ataxia type 1 (SCA1), spinocerebellar ataxia type 2 (SCA2) and Machado-Joseph disease or spinocerebellar ataxia type 3 (MJD/SCA3) are three distinctive forms of autosomal dominant spinocerebellar ataxia (SCA) caused by expansions of an unstable CAG repeat localized in the coding region of the causative genes. Another related disease, dentatorubropallidoluysian atrophy (DRPLA) is also caused by an unstable triplet repeat and can present as SCA in late onset patients. We investigated the frequency of the SCA1, SCA2, MJD/SCA3 and DRPLA mutations in 328 Brazilian patients with SCA, belonging to 90 unrelated families with various patterns of inheritance and originating in different geographic regions of Brazil. We found mutations in 35 families (39%), 32 of them with a clear autosomal dominant inheritance. The frequency of the SCA1 mutation was 3% of all patients; and 6 % in the dominantly inherited SCAs. We identified the SCA2 mutation in 6% of all families and in 9% of the families with autosomal dominant inheritance. The MJD/SCA3 mutation was detected in 30 % of all patients; and in the 44% of the dominantly inherited cases. We found no DRPLA mutation. In addition, we observed variability in the frequency of the different mutations according to geographic origin of the patients, which is probably related to the distinct colonization of different parts of Brazil. These results suggest that SCA may be occasionally caused by the SCA1 and SCA2 mutations in the Brazilian population, and that the MJD/SCA3 mutation is the most common cause of dominantly inherited SCA in Brazil.
Resumo:
CONTEXT: Mothers recall early-onset constipation in children attending gastroenterology clinics. OBJECTIVES: To study the bowel habit of young children in the community to determine, first, whether early-onset constipation is confirmed in this setting and, second, the agreement between recalled and recorded bowel habit. METHODS:Defecation data of 57 children aged 6.0-40.7 mo were obtained by maternal recall (questionnaire on predominant stool characteristics) and by record (1,934 defecations registered prospectively at home and in the nursery). The bowel habit was classified according to stool frequency and proportion of stool characteristics (soft, hard and/or runny). Two criteria were used to classify recorded data, since the cutoff point for hard stools to identify constipation is undefined in children: predominant criterion and adult criterion, respectively with >50% and >25% of stools with altered consistency. Bowel habit categories were: adequate, constipation, functional diarrhea and "other bowel habit". Nonparametric statistics, and the Kappa index for agreement between recalled and recorded bowel habit, were used. RESULTS: Constipation occurred in 17.5%, 10.5%, 19.3% of the children by recall, the predominant and the adult criteria, respectively. Constipation was the main recalled alteration, vs 12.3% "other bowel habit". Only one child classified as having functional diarrhea (by the adult criterion). Agreement between recalled and recorded bowel habit was fair for constipation, by the predominant and the adult criteria (K = 0.28 and 0.24, respectively), but only slight (K <0.16) for other bowel habit categories. Individual data, however, pointed to a better relationship between recalled constipation and the adult rather than the predominant criterion. CONCLUSIONS: Frequent early-onset constipation was confirmed. Fair agreement between recalled and recorded constipation by the two used criteria indicates that recalled data are quite reliable to detect constipation.
Resumo:
The aim of this study was to validate the intake of carotenoids, fruits and vegetables estimated by the Food Frequency Questionnaire for Adolescents (FFQA) using the method of triads. Blood samples were collected from 80 elementary school adolescents to assess serum levels of β-carotene. Partial correlation coefficients (r) were calculated between an estimated intake of carotenoids, fruits and vegetables and the serum levels of β-carotene. Validity coefficients were calculated using the method of triads. With the exception of carotenoids, partial r from the food frequency questionnaire (FFQ) were greater than those of the 24-hour recall (24hR). The fruit/vegetable group showed the highest partial r for the FFQ (r = 0.235) and the 24hR (r = 0.137). The highest validity coefficient was obtained for the vegetable group, as assessed by the FFQ (r = 0.873). On average, the validity coefficient values for the FFQ were greater than those obtained for the 24hR or the β-carotene serum levels. The FFQA is an accurate tool for estimating the intake of carotenoids, fruits and vegetables in this population group.
Resumo:
This study describes the validity of a food frequency questionnaire (FFQ) in 93 low-income women (20-65 years), participating in a case-control study in São Paulo, Brazil. Two FFQ (FFQ1 and FFQ2, 12 months apart) and three 24-hour dietary recalls (24hR) were conducted between 2003 and 2004 to estimate dietary intake during the past year. The Pearson correlation coefficients (crude, energy-adjusted and de-attenuated) were used for comparisons between FFQ and 24hR. The agreement between the methods was further examined by the Bland-Altman analysis. For the assessment of long-term reliability, the energy-adjusted intra-class correlation coefficients were mostly around 0.40, but higher for vitamin A and folate (0.50-0.56). Energy-adjusted, attenuation-corrected Pearson validity correlations between FFQ and DR ranged from 0.30-0.54 for macronutrients to 0.20-0.48 for micronutrients, with higher value for calcium (0.75). There were small proportions of grossly misclassified nutrient intakes, while Bland-Altman plots indicated that the FFQ is accurate in assessing nutrient intake at a group level.
Resumo:
A case-control study was carried out in litters of 1 to 7-day-old piglets to identify the main infectious agents involved with neonatal diarrhea in pigs. Fecal samples (n=276) from piglets were collected on pig farms in the State of Rio Grande do Sul, Brazil, from May to September 2007. Litters with diarrhea were considered cases (n=129) and normal litters (n=147) controls. The samples were examined by latex agglutination test, PAGE, conventional isolating techniques, ELISA, PCR, and microscopic methods in order to detect rotavirus, bacterial pathogens (Escherichia coli, Clostridium perfringens type A and C, and Clostridium difficile), and parasites (Coccidian and Cryptosporidium spp.). Outbreaks of diarrhea were not observed during sampling. At least one agent was detected in fecal samples on 25 out of 28 farms (89.3%) and in 16 farms (57.1%) more than one agent was found. The main agents diagnosed were Coccidia (42.86%) and rotavirus (39.29%). The main agents identified in litters with diarrhea were Clostridium difficile (10.6%), Clostridium perfringens type A (8.8%) and rotavirus (7.5%); in control litters, Clostridium difficile (16.6%) and Coccidian (8.5%). Beta hemolytic Escherichia coli and Clostridium perfringens type C were not detected. When compared with controls, no agent was significantly associated with diarrhea in case litters. These findings stress the need for caution in the interpretation of laboratorial diagnosis of mild diarrhea in neonatal pigs, as the sole detection of an agent does not necessarily indicate that it is the cause of the problem.
Resumo:
Carrying out information about the microstructure and stress behaviour of ferromagnetic steels, magnetic Barkhausen noise (MBN) has been used as a basis for effective non-destructive testing methods, opening new areas in industrial applications. One of the factors that determines the quality and reliability of the MBN analysis is the way information is extracted from the signal. Commonly, simple scalar parameters are used to characterize the information content, such as amplitude maxima and signal root mean square. This paper presents a new approach based on the time-frequency analysis. The experimental test case relates the use of MBN signals to characterize hardness gradients in a AISI4140 steel. To that purpose different time-frequency (TFR) and time-scale (TSR) representations such as the spectrogram, the Wigner-Ville distribution, the Capongram, the ARgram obtained from an AutoRegressive model, the scalogram, and the Mellingram obtained from a Mellin transform are assessed. It is shown that, due to nonstationary characteristics of the MBN, TFRs can provide a rich and new panorama of these signals. Extraction techniques of some time-frequency parameters are used to allow a diagnostic process. Comparison with results obtained by the classical method highlights the improvement on the diagnosis provided by the method proposed.
Resumo:
This work deals with an improved plane frame formulation whose exact dynamic stiffness matrix (DSM) presents, uniquely, null determinant for the natural frequencies. In comparison with the classical DSM, the formulation herein presented has some major advantages: local mode shapes are preserved in the formulation so that, for any positive frequency, the DSM will never be ill-conditioned; in the absence of poles, it is possible to employ the secant method in order to have a more computationally efficient eigenvalue extraction procedure. Applying the procedure to the more general case of Timoshenko beams, we introduce a new technique, named ""power deflation"", that makes the secant method suitable for the transcendental nonlinear eigenvalue problems based on the improved DSM. In order to avoid overflow occurrences that can hinder the secant method iterations, limiting frequencies are formulated, with scaling also applied to the eigenvalue problem. Comparisons with results available in the literature demonstrate the strength of the proposed method. Computational efficiency is compared with solutions obtained both by FEM and by the Wittrick-Williams algorithm.