1000 resultados para force validation


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Haptically enabled virtual reality systems facilitate rapid and low cost testing for process design, training practices and ergonomic analysis in many manufacturing industries, particularly automotive and aerospace. In this work we design a validation framework to validate the dynamic forces displayed by haptic display devices using a robot arm equipped with a force sensor. The validation framework is completely autonomous to ensure unbiased characterization. Measured force magnitude and the direction of the sensed force vector are the main criteria used in this work.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study demonstrates a novel technique of preparing drug colloid probes to determine the adhesion force between the drug salbutamol sulphate (SS) and the surfaces of polymer microparticles to be used as carriers for the dispersion of drug particles from a dry powder inhaler (DPI) formulation. Initially model silica probes of approximately 4 μm size, similar to a drug particle used in DPI formulations, were coated with a saturated SS solution with the aid of capillary forces acting between the silica probe and the drug solution. The developed method of ensuring a smooth and uniform layer of SS on the silica probe was validated using X-Ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM). Using the same technique, silica microspheres preattached on the AFM cantilever were coated with SS. The adhesion forces between the silica probe and drug coated silica (drug probe) and polymer surfaces (hydrophilic and hydrophobic) were determined. Our experimental results showed that the technique for preparing the drug probe was robust and can be used to determine the adhesion force between hydrophilic/hydrophobic drug probe and carrier surfaces to gain a better understanding on drug carrier adhesion forces in DPI formulations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Traction force microscopy (TFM) is commonly used to estimate cells’ traction forces from the deformation that they cause on their substrate. The accuracy of TFM highly depends on the computational methods used to measure the deformation of the substrate and estimate the forces, and also on the specifics of the experimental set-up. Computer simulations can be used to evaluate the effect of both the computational methods and the experimental set-up without the need to perform numerous experiments. Here, we present one such TFM simulator that addresses several limitations of the existing ones. As a proof of principle, we recreate a TFM experimental set-up, and apply a classic 2D TFM algorithm to recover the forces. In summary, our simulator provides a valuable tool to study the performance, refine experimentally, and guide the extraction of biological conclusions from TFM experiments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study demonstrates a novel technique of preparing drug colloid probes to determine the adhesion force between a model drug salbutamol sulphate (SS) and the surfaces of polymer microparticles to be used as carriers for the dispersion of drug particles from dry powder inhaler (DPI) formulations. Model silica probes of approximately 4 lm size, similar to a drug particle used in DPI formulations, were coated with a saturated SS solution with the aid of capillary forces acting between the silica probe and the drug solution. The developed method of ensuring a smooth and uniform layer of SS on the silica probe was validated using X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM). Using the same technique, silica microspheres pre-attached on the AFM cantilever were coated with SS. The adhesion forces between the silica probe and drug coated silica (drug probe) and polymer surfaces (hydrophilic and hydrophobic) were determined. Our experimental results showed that the technique for preparing the drug probe was robust and can be used to determine the adhesion force between hydrophilic/ hydrophobic drug probe and carrier surfaces to gain a better understanding on drug carrier adhesion forces in DPI formulations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Emissions, fuel burn, and noise are the main drivers for innovative aircraft design. Embedded propulsion systems, such as for example used in hybrid-wing body aircraft, can offer fuel burn and noise reduction benefits but the impact of inlet flow distortion on the generation and propagation of turbomachinery noise has yet to be assessed. A novel approach is used to quantify the effects of non-uniform flow on the creation and propagation of multiple pure tone (MPT) noise. The ultimate goal is to conduct a parametric study of S-duct inlets to quantify the effects of inlet design parameters on the acoustic signature. The key challenge is that the effects of distortion transfer, noise source generation and propagation through the non-uniform flow field are inherently coupled such that a simultaneous computation of the aerodynamics and acoustics is required to capture the mechanisms at play. The technical approach is based on a body force description of the fan blade row that is able to capture the distortion transfer and the blade-to-blade flow variations that cause the MPT noise while reducing computational cost. A single, 3-D full-wheel CFD simulation, in which the Euler equations are solved to second-order spatial and temporal accuracy, simultaneously computes the MPT noise generation and its propagation in distorted inlet flow. A new method of producing the blade-to-blade variations in the body force field for MPT noise generation has been developed and validated. The numerical dissipation inherent to the solver is quantified and used to correct for non-physical attenuation in the far-field noise spectra. Source generation, acoustic propagation and acoustic energy transfer between modes is examined in detail. The new method is validated on NASA's Source Diagnostic Test fan and inlet, showing good agreement with experimental data for aerodynamic performance, acoustic source generation, and far-field noise spectra. The next steps involve the assessment of MPT noise in serpentine inlet ducts and the development of a reduced order formulation suitable for incorporation into NASA's ANOPP framework. © 2010 by Jeff Defoe, Alex Narkaj & Zoltan Spakovszky.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The Trendelenburg Test (TT) is used to assess the functional strength of the hip abductor muscles (HABD), their ability to control frontal plane motion of the pelvis, and the ability of the lumbopelvic complex to transfer load into single leg stance. Rationale: Although a standard method to perform the test has been described for use within clinical populations, no study has directly investigated Trendelenburg’s hypotheses. Purpose: To investigate the validity of the TT using an ultrasound guided nerve block (UNB) of the superior gluteal nerve and determine whether the reduction in HABD strength would result in the theorized mechanical compensatory strategies measured during the TT. Methods: Quasi-experimental design using a convenience sample of nine healthy males. Only subjects with no current or previous injury to the lumbar spine, pelvis, or lower extremities, and no previous surgeries were included. Force dynamometry was used to evaluation HABD strength (%BW). 2D mechanics were used to evaluate contralateral pelvic drop (cMPD), change in contralateral pelvic drop (∆cMPD), ipsilateral hip adduction (iHADD) and ipsilateral trunk sway (TRUNK) measured in degrees (°). All measures were collected prior to and following a UNB on the superior gluteal nerve performed by an interventional radiologist. Results: Subjects’ age was median 31yrs (IQR:22-32yrs); and weight was median 73kg (IQR:67-81kg). An average 52% reduction of HABD strength (z=2.36,p=0.02) resulted following the UNB. No differences were found in cMPD or ∆cMPD (z=0.01,p= 0.99, z=-0.67,p=0.49). Individual changes in biomechanics show no consistency between subjects and non-systematic changes across the group. One subject demonstrated the mechanical compensations described by Trendelenburg. Discussion: The TT should not be used as screening measure for HABD strength in populations demonstrating strength greater than 30%BW but reserved for use with populations with marked HABD weakness. Importance: This study presents data regarding a critical level of HABD strength required to support the pelvis during the TT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We carried out quantum mechanics (QM) studies aimed at improving the performance of hydrogen fuel cells. This led to predictions of improved materials, some of which were subsequently validated with experiments by our collaborators.

In part I, the challenge was to find a replacement for the Pt cathode that would lead to improved performance for the Oxygen Reduction Reaction (ORR) while remaining stable under operational conditions and decreasing cost. Our design strategy was to find an alloy with composition Pt3M that would lead to surface segregation such that the top layer would be pure Pt, with the second and subsequent layers richer in M. Under operating conditions we expect the surface to have significant O and/or OH chemisorbed on the surface, and hence we searched for M that would remain segregated under these conditions. Using QM we examined surface segregation for 28 Pt3M alloys, where M is a transition metal. We found that only Pt3Os and Pt3Ir showed significant surface segregation when O and OH are chemisorbed on the catalyst surfaces. This result indicates that Pt3Os and Pt3Ir favor formation of a Pt-skin surface layer structure that would resist the acidic electrolyte corrosion during fuel cell operation environments. We chose to focus on Os because the phase diagram for Pt-Ir indicated that Pt-Ir could not form a homogeneous alloy at lower temperature. To determine the performance for ORR, we used QM to examine all intermediates, reaction pathways, and reaction barriers involved in the processes for which protons from the anode reactions react with O2 to form H2O. These QM calculations used our Poisson-Boltzmann implicit solvation model include the effects of the solvent (water with dielectric constant 78 with pH 7 at 298K). We found that the rate determination step (RDS) was the Oad hydration reaction (Oad + H2Oad -> OHad + OHad) in both cases, but that the barrier for pure Pt of 0.50 eV is reduced to 0.48 eV for Pt3Os, which at 80 degrees C would increase the rate by 218%. We collaborated with the Pu-Wei Wu’s group to carry out experiments, where we found that the dealloying process-treated Pt2Os catalyst showed two-fold higher activity at 25 degrees C than pure Pt and that the alloy had 272% improved stability, validating our theoretical predictions.

We also carried out similar QM studies followed by experimental validation for the Os/Pt core-shell catalyst fabricated by the underpotential deposition (UPD) method. The QM results indicated that the RDS for ORR is a compromise between the OOH formation step (0.37 eV for Pt, 0.23 eV for Pt2ML/Os core-shell) and H2O formation steps (0.32 eV for Pt, 0.22 eV for Pt2ML/Os core-shell). We found that Pt2ML/Os has the highest activity (compared to pure Pt and to the Pt3Os alloy) because the 0.37 eV barrier decreases to 0.23 eV. To understand what aspects of the core shell structure lead to this improved performance, we considered the effect on ORR of compressing the alloy slab to the dimensions of pure Pt. However this had little effect, with the same RDS barrier 0.37 eV. This shows that the ligand effect (the electronic structure modification resulting from the Os substrate) plays a more important role than the strain effect, and is responsible for the improved activity of the core- shell catalyst. Experimental materials characterization proves the core-shell feature of our catalyst. The electrochemical experiment for Pt2ML/Os/C showed 3.5 to 5 times better ORR activity at 0.9V (vs. NHE) in 0.1M HClO4 solution at 25 degrees C as compared to those of commercially available Pt/C. The excellent correlation between experimental half potential and the OH binding energies and RDS barriers validate the feasibility of predicting catalyst activity using QM calculation and a simple Langmuir–Hinshelwood model.

In part II, we used QM calculations to study methane stream reforming on a Ni-alloy catalyst surfaces for solid oxide fuel cell (SOFC) application. SOFC has wide fuel adaptability but the coking and sulfur poisoning will reduce its stability. Experimental results suggested that the Ni4Fe alloy improves both its activity and stability compared to pure Ni. To understand the atomistic origin of this, we carried out QM calculations on surface segregation and found that the most stable configuration for Ni4Fe has a Fe atom distribution of (0%, 50%, 25%, 25%, 0%) starting at the bottom layer. We calculated that the binding of C atoms on the Ni4Fe surface is 142.9 Kcal/mol, which is about 10 Kcal/mol weaker compared to the pure Ni surface. This weaker C binding energy is expected to make coke formation less favorable, explaining why Ni4Fe has better coking resistance. This result confirms the experimental observation. The reaction energy barriers for CHx decomposition and C binding on various alloy surface, Ni4X (X=Fe, Co, Mn, and Mo), showed Ni4Fe, Ni4Co, and Fe4Mn all have better coking resistance than pure Ni, but that only Ni4Fe and Fe4Mn have (slightly) improved activity compared to pure Ni.

In part III, we used QM to examine the proton transport in doped perovskite-ceramics. Here we used a 2x2x2 supercell of perovskite with composition Ba8X7M1(OH)1O23 where X=Ce or Zr and M=Y, Gd, or Dy. Thus in each case a 4+ X is replace by a 3+ M plus a proton on one O. Here we predicted the barriers for proton diffusion allowing both includes intra-octahedron and inter-octahedra proton transfer. Without any restriction, we only observed the inter-octahedra proton transfer with similar energy barrier as previous computational work but 0.2 eV higher than experimental result for Y doped zirconate. For one restriction in our calculations is that the Odonor-Oacceptor atoms were kept at fixed distances, we found that the barrier difference between cerates/zirconates with various dopants are only 0.02~0.03 eV. To fully address performance one would need to examine proton transfer at grain boundaries, which will require larger scale ReaxFF reactive dynamics for systems with millions of atoms. The QM calculations used here will be used to train the ReaxFF force field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ice accretions can significantly change the aerodynamic performance of wings and rotor blades. Significant performance degradation can occur when ice accreations cause regions of separated flow, to predict this change implies, at a minimum, the solution of the Reynolds-Averaged Navier-Stokes equations. This paper presents validation for two generic cases involving the flow over aerofoil sections with added synthetic ice shapes. Results were obtained for two aerofoils, namely the NACA 23012 and a generic multi-element configuration. These results are compared with force and pressure coefficient measurements obtained in the NASA LTPT wind-tunnel for the NACA 23012, and force, PIV and boundary-layer measurements obtained at DNW for the multi-clement case. The level of agreement is assessed in the context of industrial requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: This study validates different definitions of reported night blindness (XN) in a vitamin A deficient African population with no local term for XN. DESIGN: Case-control study with follow-up after treatment. SETTING: Eight primary schools and health centres in rural Tanzania. SUBJECTS: A total of 1214 participants were screened for reported XN and other eye signs of xerophthalmia: 461 children aged 24-71 months, 562 primary school-age children and 191 pregnant or breast-feeding women. All 152 cases of reported XN were selected for the validation study and group matched with 321 controls who did not complain of XN. XN reports were validated against serum retinol concentrations and pupillary dark adaptation measurements in cases and controls. INTERVENTION: All children and women who reported XN or had other signs of active xerophthalmia were treated with vitamin A and followed up 3-4 weeks later. Half of the untreated control group who had their serum retinol examined in the baseline examination were also followed up. RESULTS: The overall prevalence of reported XN was 12.5%. At baseline, mean pupillary threshold (-1.52 vs -1.55 log cd/m(2), P=0.501) and median serum retinol concentrations (0.95 vs 0.93 micromol/l, P=0.734) were not significantly different in cases and controls either overall or in each population group. More restricted case definitions reduced the prevalence of reported XN to 5.5% (P<0.001), but there was still no significant difference between cases and controls although the results were in the expected direction. After treatment, the median serum retinol concentration improved significantly only in the most deficient group, the young children. Dark adaptation improved in all the subgroups but the difference was only significant for young children and primary school-age children when the restricted case definitions were used. CONCLUSIONS: XN reports are a poor indicator of vitamin A deficiency in this population. SPONSORSHIP: Task Force Sight and Life, Basel, Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 3D intralaminar continuum damage mechanics based material model, combining damage mode interaction and material nonlinearity, was developed to predict the damage response of composite structures undergoing crush loading. This model captures the structural response without the need for calibration of experimentally determined material parameters. When used in the design of energy absorbing composite structures, it can reduce the dependence on physical testing. This paper validates this model against experimental data obtained from the literature and in-house testing. Results show that the model can predict the force response of the crushed composite structures with good accuracy. The simulated energy absorption in each test case was within 12% of the experimental value. Post-crush deformation and the damage morphologies, such as ply splitting, splaying and breakage, were also accurately reproduced. This study establishes the capability of this damage model for predicting the responses of composite structures under crushing loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La douleur est une expérience multidimensionnelle comportant des aspects sensoriels, émotionnels et cognitifs. Théoriquement, des méthodes de mesures comportementales, physiologiques, neurophysiologiques et sensorielles peuvent quantifier la douleur. Peu d’études ont étudié la validation des mesures utilisées en médecine vétérinaire. La recherche combine les travaux de Maîtrise et de Doctorat, traite en partie de la validité de méthodes. Dans cet objectif, nos travaux de recherche étudiaient la validité de méthodes comportementales, physiologiques et neurophysiologiques usuelles pour la mesure de la douleur en comparant les expressions de douleur (vache et chien) chez des animaux contrôle par comparaison à des animaux sous analgésie préventive ou sous traitement curatif suivant une douleur induite par chirurgie (modèles de douleur viscérale bovine ou orthopédique canine) ou causée par une maladie naturelle (arthrose canine). Une première étude comparait les mesures de la douleur entre les vaches du groupe placebo et celles sous analgésie postopératoire sur une durée de 21 jours suivant l’induction d’une douleur viscérale chronique. Les vaches du groupe placebo ont présenté une plus forte sensibilité à la douleur et une diminution de la noradrénaline et de la transthyrétine mesurées dans le liquide cérébro-spinal, une diminution de l’activité motrice (AM) (moindre que dans les groupes avec analgésie), de l’agitation enregistrée par vidéo-analyse et une augmentation du stress selon la mesure de l’activité électrodermique (AED). Les méthodes d’intérêt identifiées étaient les marqueurs spinaux, la mesure de la sensibilisation, de comportements par vidéo-analyse et de l’AM par bio-télémétrie. En utilisant des méthodes semblables à celles précédemment décrites, deux études expérimentales de douleur orthopédique ont été réalisées afin de comparer les réponses à la douleur entre des chiens traités avec une analgésie préventive (opioïdes et anti-inflammatoires, étude #2) ou un biphosphonate (tiludronate, étude #3) par comparaison à des chiens contrôles. Seules les échelles de douleur étaient différentes entre les études de recherche. Pour l’étude #2, les ii chiens sous analgésie ont présenté de plus faibles scores de douleur mesurés avec l’échelle de douleur nommée 4A-VET et ceci simultanément à une faible réponse de l’AED une heure après la chirurgie de trochléoplastie. La fréquence du comportement spontané de ‘la marche avec plein appui de la patte opérée’ mesurée à l’aide de la vidéo-analyse augmentait chez les chiens sous analgésie préventive 24 heures après la chirurgie. L’étude #3 démontrait surtout l’apparition de sensibilisation centrale (à la fois par l’évaluation sensorielle quantitative et les marqueurs spinaux) chez les chiens contrôle, 56 jours après l’induction d’arthrose chirurgicale. Ainsi, les chiens traités avec le tiludronate ont présenté une différence sur la substance P et la transthyrétine cérébro-spinale, une diminution de la sensibilisation périphérique, plus d’appui de la patte opérée lors de la marche selon la mesure du pic de force verticale (PFV), une augmentation de la fréquence de ‘la marche avec plein appui de la patte opérée’. La sensibilisation centrale était associée à la diminution de PFV, et une augmentation de l’AED et du comportement spontané de ‘la marche avec plein appui de la patte opérée’. Pour l’étude #4, la validité et la sensibilité des méthodes ont été évaluées dans une condition d’arthrose naturelle chez des chiens traités avec une diète enrichie en moule verte, un produit ayant des effets anti-inflammatoires et chondroprotecteurs attendus. Les chiens traités présentaient une diminution des scores de douleur via l’échelle nommée CSOM, une augmentation de PFV et une augmentation de l’AM. Dans l’ensemble, les résultats confirment que la vidéo-analyse évaluait la douleur de façon objective et pour des modèles différents de douleur et les marqueurs spinaux sont prometteurs. Le PFV était spécifique de la douleur orthopédique. La sensibilisation était présente lors de douleur pathologique. L’AED n’est pas valide pour la mesure de la douleur. La baisse d’AM suggèrerait un comportement de douleur. Les études étaient exploratoires pour les échelles de douleur en raison de leur niveau (débutant) de développement et du manque d’informations sur les qualités métrologiques de ces mesures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Throughout the industrial processes of sheet metal manufacturing and refining, shear cutting is widely used for its speed and cost advantages over competing cutting methods. Industrial shears may include some force measurement possibilities, but the force is most likely influenced by friction losses between shear tool and the point of measurement, and are in general not showing the actual force applied to the sheet. Well defined shears and accurate measurements of force and shear tool position are important for understanding the influence of shear parameters. Accurate experimental data are also necessary for calibration of numerical shear models. Here, a dedicated laboratory set-up with well defined geometry and movement in the shear, and high measurability in terms of force and geometry is designed, built and verified. Parameters important to the shear process are studied with perturbation analysis techniques and requirements on input parameter accuracy are formulated to meet experimental output demands. Input parameters in shearing are mostly geometric parameters, but also material properties and contact conditions. Based on the accuracy requirements, a symmetric experiment with internal balancing of forces is constructed to avoid guides and corresponding friction losses. Finally, the experimental procedure is validated through shearing of a medium grade steel. With the obtained experimental set-up performance, force changes as result of changes in studied input parameters are distinguishable down to a level of 1%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to examine the validity of a commercially-available accelerometer, as used in the field team sports context. Ten adult participants completed two movement tasks: 1) a drop landing task from 30-cm, 40-cm and 50-cm heights [DLAND], and 2) a countermovement jumping task [CMJ]. Peak acceleration values, both smoothed and unsmoothed, occurring in the longitudinal axis [Y] and calculated to produce vector magnitude values [VM], were compared to peak vertical ground reaction force values [VGRF]. All acceleration measures were moderately correlated (r = 0.45 – 0.70), but also significantly higher than weight-adjusted VGRF, for both tasks. Though the raw acceleration measures were mostly above the acceptable limit for error (> 20%), the smoothed data had reduced error margins by comparison, most of which were well below 20%. These results provide some support for the continued use of accelerometer data, particularly when smoothed, to accurately quantify impacts in the field.