1000 resultados para force gradation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose : To establish if visual feedback and force requirements influence SICI.

Methods : SICI was assessed from 10 healthy adults (5 males and 5 females aged between 21 and 35 years) in three submaximal isometric elbow flexion torque levels [5, 20, and 40% of maximal voluntary contraction (MVC)] and with two tasks differing in terms of visual feedback. Single-pulse and paired-pulse motor-evoked potentials (MEPs), supramaximal M-wave, and background surface electromyogram (sEMG) were recorded from the biceps brachii muscle.

Results : Repeated measures MANOVA was used for statistical analyses. Background sEMG did not differ between tasks (F = 0.4, P = 0.68) nor was task × torque level interaction observed (F = 1.2, P = 0.32), whereas background sEMG increased with increasing torque levels (P = 0.001). SICI did not differ between tasks (F = 0.9, P = 0.43) and no task × torque level interaction was observed (F = 2.3, P = 0.08). However, less SICI was observed at 40% MVC compared to the 5 and 20% MVC torque levels (P = 0.01–0.001).

Conclusion :
SICI was not altered by performing the same task with differing visual feedback. However, SICI decreased with increasing submaximal torque providing further evidence that SICI is one mechanism of modulating cortical excitability and plays a role in force gradation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated sex-related differences in the tibialis anterior (TA) surface electromyography (EMG) to force relationship. One-hundred participants (50 males and 50 females) performed three isometric contractions at 20, 40, 60, 80, and 100% of maximal voluntary contraction (MVC) in an apparatus designed to isolate the action of the dorsiflexors. The surface EMG signal was amplified (lOOOx), band-pass filtered (10-500Hz), and sampled at 2048 Hz. The load cell signal was low-passed filtered at 100 Hz and sampled at the same rate. Males were stronger than females {P <0.05). However, there was no significant difference in root-mean-square (RMS) values between sexes {P <0.05). Both sexes exhibited a quadratic increase in RMS across force levels (P <0.05). The mean power frequency (MNF) for males was greater than for females {P <0.05). Males and females exhibited a linear increase in both frequency measures up to 80% of MVC (P <0.05). Between 80 and 100% MVC, the frequency values for the females plateaued while males showed a decrease {P <0.05). The magnitude of the difference in MNF between males and females was consistent with sex-specific TA physiology. In general, the pattern of means for RMS and MNF between males and females revealed no sex-related differences in the surface EMG/force relationship. We therefore conclude that there are no sex-related differences in the gradation of muscle force.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé : Cette étude examine l'impact de la taille et de la gradation de particules sur les corrélations théoriques et empiriques existantes les plus connues entre la résistance au cisaillement et le comportement dilatatant des matériaux granulaires en condition de déformation plane et en compression triaxiale drainée. À cette fin, 276 tests de cisaillements symétriques directs et 35 tests de compressions triaxiales drainées ont été menés sur des échantillons composés de billes de basalte (particules rondes), et de sables constitués de particules angulaires (sable de Péribonka et sable d'Eastmain) sur une échelle de 63 µm à 2000 µm afin d'évaluer leur résistance au cisaillement et leur comportement de dilatance sur une vaste échelle de pressions normales et de densités relatives initiales. Premièrement, la fiabilité et l'applicabilité des limites de mesure à l’aide de tests physiques de cisaillements symétriques directs dans l'interprétation de la résistance au cisaillement frictionnel en déformation plane des matériaux granulaires ont été discutées et confirmées par l'usage du code informatique DEM, SiGran. L'accent a été particulièrement mis sur la validation du modèle DEM au moyen de comparaison des résultats des simulations DEM avec leurs équivalents physiques à une échelle macro. Les résultats virtuels DSA sont abordés du point de vue de la coaxialité entre les principales tensions et les principales directions des paliers de pression ainsi que de la déviation de la direction d'extension nulle à partir de la direction horizontale. Les résultats numériques fournissent également des données quantitatives sur les différentes formes d'énergie consommées durant le cisaillement confirmées par d'autres résultats physiques et numériques publiés. Sur la base des postulats précédents, un examen minutieux des résultats des essais de cisaillements directs et de données issues de la littérature a été accompli afin d'évaluer la fiabilité des formules empiriques bien connues de Bolton et Collins et al. avec leurs constantes couramment employées en condition de déformation plane. L'étude montre qu'une application des relations empiriques de force-dilatation de cisaillement avec les constantes proposées par Bolton (1986) et Collins et al. (1992) aux sables ayant une distribution de taille de particules différente peut conduire à surestimer leurs valeurs en terme de force de cisaillement. Dans cette étude, les coefficients des équations de Bolton et Collins et al. ont donc été ajustée afin de prendre en compte les caractéristiques des particules, en particulier le diamètre médian, D50. De manière analogue, les effets microstructuraux imposés par la géométrie interne des particules (par exemple la taille, la forme et la gradation des particules) sur la relation tension-dilatation très connue, celle de Rowe (1962), et son ajustement empirique en condition triaxiale drainée ont été examinés dans cette étude. Une comparaison des prédictions des formules proposées avec les données de force de cisaillement issues de la littérature fournit de nombreuses preuves en faveur des contraintes mises en place au sein des relations existantes de force-dilatation de cisaillement en condition de déformation plane et triaxiale. Ces comparaisons prouvent également que la prise en compte de la taille des grains conduit à des résultats plus tangibles que lorsque la taille de la particule n'est pas considérée. Les formules de force-dilatation ajustées peuvent se révéler avantageuses pour évaluer indépendamment la cohérence des forces de cisaillement déterminées expérimentalement et pour introduire des lois d’écoulement plus précises dans les analyses géotechniques analytiques et numériques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(-)-CGP12177 is a non-conventional partial agonist that causes modest and transient increases of contractile force in human atrial trabeculae (Kaumann and Molenaar, 2008). These effects are markedly increased and maintained by inhibition of phosphodiesterase PDE3. As verified with recombinant receptors, the cardiostimulant effect of (-)-CGP12177 is mediated through a site at the beta1-adrenoceptor with lower affinity (beta1LAR) compared to the site through which (-)-CGP12177 antagonizes the effects of catecholamines (beta1HAR). However, in a recent report it was proposed that the positive inotropic effects of CGP12177 are mediated through beta3-adrenoceptors (Skeberdis et al 2008). We therefore investigated whether the effects of (-)-CGP12177 on human atrial trabeculae are antagonized by the beta3-adrenoceptor-selective antagonist L-748,337 (1 microM). (-)-CGP12177 (200 nM) caused a stable increase in force which was significantly reduced by the addition of (-)-bupranolol (1 microM), P = 0.002, (basal 4.45 ± 0.78 mN, IBMX (PDE inhibitor) 5.47 ± 1.01 mN, (-)-CGP12177 9.34 ± 1.33 mN, (-)-bupranolol 5.79 ± 1.08 mN, n = 6) but not affected by the addition of L-748,337 (1 microM), P = 0.12, (basal 4.48 ± 1.32 mN, IBMX 7.15 ± 2.28 mN, (-)-CGP12177 12.51 ± 3.71 mN, L-748,337 10.90 ± 3.49 mN, n = 6). Cumulative concentration-effect curves for (-)-CGP12177 were not shifted to the right by L-748,337 (1 microM). The –logEC50M values of (-)-CGP12177 in the absence and presence of L-748,337 were 7.21±0.09 and 7.41±0.13, respectively (data from 25 trabeculae from 8 patients, P=0.2) The positive inotropic effects of (-)-CGP12177 (IBMX present) were not antagonized by L-748,337 but were blunted by (-)-bupranolol (1 microM). The results rule out an involvement of beta3-adrenoceptors in the positive inotropic effects (-)-CGP12177 in human right atrial myocardium and are consistent with mediation through beta1LAR. Kaumann A and Molenaar P (2008) Pharmacol Ther 118, 303-336 Skeberdis VA et al (2008) J Clin Invest, 118, 3219-3227

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Throughout the developed world demographic trends and their forecast consequences are attracting the attention of governments, academics, think tanks and the popular press alike. Population aging, in particular, is the focus of many and has generated extensive debate. Approaches commonly advocated in the literature include a mix of ‘population', ‘participation’ and ‘productivity’ measures. Immigration and population policy alongside industry reform and related productivity initiatives are also being pursued. Participation, however, remains a key element of the demographic change policy response. Evidence suggests however, that these approaches are unlikely to deliver the necessary labour force volumes. This has prompted a shift in the participation agenda to also include a stronger focus on skilled and experienced older workers. The literature suggests, however, that the current suite of practices are less than effective for the long-term unemployed, previously long-tenured older workers with specialised skills and trade-displaced workers. Adverse health and human capital outcomes often associated with social disadvantage are complicating factors. This reminds of the complexity of the challenge in seeking to deliver social equity to the disadvantaged and suggests a need for an alternative policy architecture. By integrating the three concepts of health capital, human capital and social capital we show how policy has to change if the older age cohorts of jobseekers are to be assisted to remain employable. This review includes an examination of current policy, a consolidation of the literature and original data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aging in humans is associated with a loss in neuromuscular function and performance. This is related, in part, to the reduction in muscular strength and power caused by a loss of skeletal muscle mass (sarcopenia) and changes in muscle architecture. Due to these changes, the force-velocity (f-v) relationship of human muscles alters with age. This change has functional implications such as slower walking speeds. Different methods to reverse these changes have been investigated, including traditional resistance training, power training and eccentric (or eccentrically-biased) resistance training. This review will summarise the changes of the f-v relationship with age, the functional implications of these changes and the various methods to reverse or at least partly ameliorate these changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an automated system for 3D assembly of tissue engineering (TE) scaffolds made from biocompatible microscopic building blocks with relatively large fabrication error. It focuses on the pin-into-hole force control developed for this demanding microassembly task. A beam-like gripper with integrated force sensing at a 3 mN resolution with a 500 mN measuring range is designed, and is used to implement an admittance force-controlled insertion using commercial precision stages. Visual-based alignment followed by an insertion is complemented by a haptic exploration strategy using force and position information. The system demonstrates fully automated construction of TE scaffolds with 50 microparts whose dimension error is larger than 5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes the use of optical flow from a moving robot to provide force feedback to an operator’s joystick to facilitate collision free teleoperation. Optical flow is measured by a pair of wide angle cameras on board the vehicle and used to generate a virtual environmental force that is reflected to the user through the joystick, as well as feeding back into the control of the vehicle. We show that the proposed control is dissipative and prevents the vehicle colliding with the environment as well as providing the operator with a natural feel for the remote environment. Experimental results are provided on the InsectBot holonomic vehicle platform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes the use of optical flow from a moving robot to provide force feedback to an operator's joystick to facilitate collision free teleoperation. Optic flow is measured by wide angle cameras on board the vehicle and used to generate a virtual environmental force that is reflected to the user through the joystick, as well as feeding back into the control of the vehicle. The coupling between optical flow (velocity) and force is modelled as an impedance - in this case an optical impedance. We show that the proposed control is dissipative and prevents the vehicle colliding with the environment as well as providing the operator with a natural feel for the remote environment. The paper focuses on applications to aerial robotics vehicles, however, the ideas apply directly to other force actuated vehicles such as submersibles or space vehicles, and the authors believe the approach has potential for control of terrestrial vehicles and even teleoperation of manipulators. Experimental results are provided for a simulated aerial robot in a virtual environment controlled by a haptic joystick.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanoindentation is a useful technique for probing the mechanical properties of bone, and finite element (FE) modeling of the indentation allows inverse determination of elasto-plastic constitutive properties. However, FE simulations to date have assumed frictionless contact between indenter and bone. The aim of this study was to explore the effect of friction in simulations of bone nanoindentation. Two dimensional axisymmetric FE simulations were performed using a spheroconical indenter of tip radius 0.6m and angle 90°. The coefficient of friction between indenter and bone was varied between 0.0 (frictionless) and 0.3. Isotropic linear elasticity was used in all simulations, with bone elastic modulus E=13.56GPa and Poisson’s ratio =0.3. Plasticity was incorporated using both Drucker-Prager and von Mises yield surfaces. Friction had a modest effect on the predicted force-indentation curve for both von Mises and Drucker-Prager plasticity, reducing maximum indenter displacement by 10% and 20% respectively as friction coefficient was increased from zero to 0.3 (at a maximum indenter force of 5mN). However, friction has a much greater effect on predicted pile-up after indentation, reducing predicted pile-up from 0.27m to 0.11m with a von Mises model, and from 0.09m to 0.02m with Drucker-Prager plasticity. We conclude that it is important to include friction in nanoindentation simulations of bone.