122 resultados para flush


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance assessment as to water consumption in WC cisterns has contributed to the development of flushing system technologies, which allow smaller flushing volumes. The purpose of this work is to assess the performance of the the low water consumption requirement of WC cisterns with dual flushing system (6/3L), when compared to 6L flushing volume WC cisterns in multifamily buildings. The research methodology consisted of a case study in a multifamily residential building with submetering system, by monitoring the total water consumption and the two flushing systems using water meters installed in WC cisterns. By means of a mathematical model, a comparison of the design flowrate in the main branch was carried out considering the two types of WC cisterns. The results indicated that the water consumption in the 6L WC cistern was 20% in relation to the total domestic consumption, whereas the water consumption observed in the dual-flush WC cistern (6/3L) was 16%. The dual flushing system (6/3L) presented about 18% consumption reduction impact as compared to the 6 L system. The design flowrate values in the main branch, obtained by the mathematical model, were 0.35 L/s for systems with 6 L WC cistern and 0.34 L/s with dual-flush WC cistern (6/3 L), that is, a reduction of similar to 3%. Practical application: The knowledge of the performance in field of dual-flush WC cistern contributes to industry to improve this system and to users to aid their choice of technologies aimed at water conservation, and so assisting to the development of sustainable buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of computational fluid dynamics simulations for calibrating a flush air data system is described, In particular, the flush air data system of the HYFLEX hypersonic vehicle is used as a case study. The HYFLEX air data system consists of nine pressure ports located flush with the vehicle nose surface, connected to onboard pressure transducers, After appropriate processing, surface pressure measurements can he converted into useful air data parameters. The processing algorithm requires an accurate pressure model, which relates air data parameters to the measured pressures. In the past, such pressure models have been calibrated using combinations of flight data, ground-based experimental results, and numerical simulation. We perform a calibration of the HYFLEX flush air data system using computational fluid dynamics simulations exclusively, The simulations are used to build an empirical pressure model that accurately describes the HYFLEX nose pressure distribution ol cr a range of flight conditions. We believe that computational fluid dynamics provides a quick and inexpensive way to calibrate the air data system and is applicable to a broad range of flight conditions, When tested with HYFLEX flight data, the calibrated system is found to work well. It predicts vehicle angle of attack and angle of sideslip to accuracy levels that generally satisfy flight control requirements. Dynamic pressure is predicted to within the resolution of the onboard inertial measurement unit. We find that wind-tunnel experiments and flight data are not necessary to accurately calibrate the HYFLEX flush air data system for hypersonic flight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potted lychee trees (cv. Tai so) of varying vegetative flush maturity were grown under a range of temperature regimes and monitored for subsequent shoot structure and development. A combination of low temperature (15/17 or 18/13 degreesC day/night) and high vegetative flush maturity was necessary for floral initiation to occur, Exposure to high temperatures (28/23 degreesC) invariably resulted in the production of vegetative shoots, irrespective of flush maturity. Strong floral initiation was marked by the emergence of terminal particles and accompanying axillary particles. A decrea,;e in vegetative flush maturity or increase in temperature (e.g. 23/18 degreesC) resulted in a decrease in axillary shoot formation and the production of several intermediate shoot structures. These included leafy particles, stunted particles, partially emerged buds and non-emergent swollen buds, often produced on the same tree. At 23/18 degreesC, closer synchronisation of initial flush maturity was required for the production of a consistent shoot-type. Trees with synchronised mature flushes (I-2) at 23/18 degreesC resulted in the production of swollen terminal buds. Healthy trees were maintained in this state for at least 11 months. These results indicate that both temperature and flush maturity can influence subsequent shoot structure of lychee. In the absence of either a strong floral temperature (18/13 degreesC) or strong vegetative temperature (28/23 degreesC), slight differences in initial flush maturity have gteater impact on the type of emerging shoot formed. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flush (1933), de Virginia Woolf, protagonitzada pel gos de la poeta Elisabeth Barrett Browning, es va traduir al català cinc anys després, a Edicions de la Rosa dels Vents, quan encara es podia veure a la cartellera barcelonina la pel·lícula que narrava la història del matrimoni de poetes Browning, The Barrets of Wimpole Street, estrenada l�any 1934 i dirigida per Sidney Franklin. També havia arribat a Catalunya la traducció francesa de Charles Mauron, publicada l�any 1935. Això va fer que l�any 1938, malgrat el conflicte bèl·lic, hi hagués un context de recepció propici a aquesta traducció, encarregada per l�editor Josep Janés i Oliver. En aquest article donem a conèixer qui era la noia de divuit anys que va realitzar la traducció al català a partir de la traducció francesa, Roser Cardús i Malagarriga (1920-1974), i en descrivim la carrera com a escriptora i com a traductora.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The period, known to UK farmers and processors as the "spring flush", when the cows' diet changes from dry feed to spring pasture, has long been established as a time of change in milk properties and processing characteristics. Although it is believed to be a time when problems in processing are most likely to occur (e.g. milk that does not form clots or forms weak gels during cheesemaking), there is little evidence in the literature of detailed changes in milk composition and their impact on product manufacture. In this study, a range of physicochemical properties were analysed in milk collected from five commercial dairy herds before, during and after the spring flush period of 2006. In particular, total and ionic calcium contents of milk were studied in relation to other parameters including rennet clotting, acid gel properties, heat coagulation, alcohol stability, micelle size and zeta potential. Total divalent cations were significantly reduced from 35.4 to 33.4 mmol.L-1 during the study, while ionic calcium was reduced from 1.48 to 1.40 mmol.L-1 over the same period. Many parameters varied significantly between the sample dates. However, there was no evidence to suggest that any of the milk samples would have been unsuitable for processing - e.g. there were no samples that did not form clots with chymosin within a reasonable time or formed especially weak rennet or acid gels. A number of statistically significant correlations were found within the data, including ionic calcium concentration and pH; rennet clotting time (RCT) and micelle diameter; and RCT and ethanol stability. Overall, while there were clear variations in milk composition and properties over this period, there was no evidence to support the view that serious processing problems are likely during the change from dry feed to spring pasture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o efeito do choque térmico e mecânico na produtividade de Lentinula edodes em 140 toras de Eucalyptus saligna, completamente colonizadas pelo fungo, em diferentes tempos de imersão em água e no primeiro fluxo de produção. As toras foram imersas em água resfriada (16ºC) ou à temperatura ambiente (22ºC); os períodos de imersão corresponderam a 6, 10, 14, 18, 22, 26 e 38 horas; o choque mecânico foi acompanhado por três quedas consecutivas da tora, em posição vertical, no chão. A temperatura da água e o tempo de imersão afetaram a produção de L. edodes, resultando em aumentos significativos (2 a 4 vezes) nos tratamentos em que as toras foram submetidas à água resfriada e nos tempos de imersão mais curtos (6 e 10 horas). O choque mecânico não resultou em aumento na produção de basidiomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work considers a problem of interest in several technological applications such as the thermal control of electronic equipment. It is also important to study the heat transfer performance of these components under off-normal conditions, such as during failure of cooling fans. The effect of natural convection on the flow and heat transfer in a cavity with two flush mounted heat sources on the left vertical wall, simulating electronic components, is studied numerically and experimentally. The influence of the power distribution, spacing between the heat sources and cavity aspect ratio have been investigated. An analysis of the average Nusselt number of the two heat sources was performed to investigate the behavior of the heat transfer coefficients. The results obtained numerically and experimentally, after an error analysis, showed a good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was performed to investigate the influence of different routes of perfusion on the distribution of the preservation solutions in the lung parenchyma and upper airways. Methods: Pigs were divided into four groups: control (n = 6), pulmonary artery (PA) (n = 6), simultaneous PA + bronchial artery (BA) (n = 8), and retrograde delivery (n = 6). After preparation and cannulation, cardioplegia solution and Euro- Collins solution (ECS) for lung preservation were given simultaneously. After removal of the heart, the double lung bloc was harvested. Following parameters were assessed: total and regional perfusion (dye-labeled microspheres), tissue water content, PA, aorta, left atrial and left ventricular pressures, cardiac output and lung temperature. Results: Our data show that flow of the ECS in lung parenchyma did not reach control values (9.4 ± 1.0 ml/min per g lung wet weight) regardless of the route of delivery (PA 6.3 ± 1.5, PA + BA 4.8 ± 0.9, retrograde 2.7 ± 0.9 ml/min per g lung wet weight). However, flow in the proximal and distal trachea were significantly increased by PA + BA delivery (0.970 ± 0.4, respectively, 0.380 ± 0.2 ml/min per g) in comparison with PA (0.023 ± 0.007, respectively, 0.024 ± 0.070 ml/min per g), retrograde (0.009 ± 0.003, respectively, 0.021 ± 0.006 ml/min per g) and control experiments (0.125 ± 0.0018, respectively, 0.105 ± 0.012 ml/g per min). Similarly the highest flow rates in the right main bronchus were achieved by PA + BA delivery (1.04 ± 0.4 ml/min per g) in comparison with 0.11 ± 0.03 in control, 0.033 ± 0.008 in PA, and 0.019 ± 0.005 ml/min per g in retrograde group. Flows in the left main bronchus were 0.09 ± 0.02 ml/min per g in control, 0.045 ± 0.012 ml/min per g in PA, and 0.027 ± 0.006 ml/min per g in retrograde group. The flow rates were significantly (P = 0.001) increased by PA + BA delivery of the storage solution (0.97 ± 0.3 ml/min per g). Conclusions: Our data show that the distribution of ECS for lung preservation is significantly improved in airway tissues (trachea and bronchi) if a simultaneous PA + BA delivery is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1st edition, New York, 1953.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.