912 resultados para fluidos biológicos
Resumo:
Aunque en las últimas décadas se han producido considerables progresos en el diagnóstico y el tratamiento de la litiasis renal, la compresión de su patogenia no ha ido en paralelo con estos avances. De hecho, a pesar de los grandes esfuerzos en investigación y de un considerable número de teorías, aún se desconoce la secuencia exacta de acontecimientos que llevan a la formación de los cálculos renales. En este trabajo se realiza un estudio de los principales tipos de cálculos renales y sus posibles causas. Se estudia, concretamente, la formación de la hidroxiapatita, un cálculo renal inorgánico relativamente frecuente. Se utiliza, para tal fin, el software comercial Medusa.
Resumo:
Tesis (Maestría en Ciencias con Especialidad en Química Analítica Biomédica) UANL
Resumo:
Sabe-se que a transmissão de infecções hospitalares, via cruzada ou ambiental, é facilitada pela sobrevivência de microrganismos em superfícies secas que pode ser favorecida pela presença de fluídos biológicos. Visando demonstrar o cuidado com substâncias corporais na rotina de limpeza, esse estudo avaliou a influência de alguns fluídos biológicos (sangue, urina e saliva artificial) na sobrevivência de Staphylococcus aureus (ATCC 25923), depositados de modo similar, sobre diferentes superfícies após secagem. O sangue foi capaz de preservar a viabilidade bacteriana por até 72 dias quando depositado sobre piso cerâmico. O tecido em fibra de algodão permitiu maior tempo de sobrevivência em comparação ao tecido sintético. Esses resultados demonstram que a composição do fluído biológico e o tipo de suporte altera o tempo da sobrevivência bacteriana em condições ambientais. Palavras–chave: Staphylococcus aureus; fluidos biológicos; sobrevivência bacteriana
Resumo:
As lesões impalpáveis da mama que muitas das vezes são assintomáticas, podem corresponder à um estágio de progressão de câncer difícil de ser detectado, durante os exames de rotina de palpação da mulher. O único método possível para a descoberta dessas lesões é através dos exames de imagem da mama, de modo geral, através da mamografia, que geralmente ocorre após os 45 anos. Devido a esses fatores, lesões impalpáveis, são frequentemente, descobertas apenas quando o estágio de desenvolvimento da doença já está avançado e as intervenções terapêuticas são menos reparadoras. Com a finalidade de iniciar a caracterização de tumores impalpáveis iniciais, objetivamos analisar o perfil genético (mutação) e epigenético (metilação de região promotora) de regiões do DNA relacionadas ao gene supressor tumoral TP53, provenientes de biópsias de mulheres residentes do Estado do Rio de Janeiro. Neste trabalho, foram investigadas 34 amostras de tecido de tumor de mama, por sequenciamento de DNA, nos exons de 5 a 8 do gene TP53. Nesta região, não foi encontrada nenhuma mutação. Este resultado pode estar relacionado ao tipo inicial de lesão, de acordo com os dados radiológicos das lesões de categorias 3 e 4 da escala BIRADS. Para verificar o estado de metilação da região promotora do gene TP53, analisamos 30 pares de amostras (sangue e tumor) de pacientes com suspeita de câncer de mama, pela técnica MSP-PCR. Nenhuma amostra tumoral apresentou alteração no estado de metilação na região promotora do gene TP53, quando comparada à amostra normal. Um motivo possível para a disparidade de resultados em relação à outros trabalhos pode ter sido a utilização da técnica. A caracterização das lesões impalpáveis apenas foi iniciada neste trabalho, no qual pudemos constatar que a mutação em TP53 pode ser um evento mais tardio. Portanto, a lesão mamária, em suas diferentes formas, continuará a ser o assunto investigado por nosso grupo, ampliando o número de amostras e alcançando melhor conexão da conduta e dos métodos clínicos já existentes, com as novas possibilidades de diagnóstico via marcadores moleculares em tumores e fluidos biológicos
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas
Resumo:
A Diabetes Mellitus (DM) compreende um conjunto de desordens metabólicas comuns caracterizadas por hiperglicemia, que afeta diferentes órgãos do organismo. Ao longo do tempo, ocorrem danos microvasculares no glomérulo renal, retina e nervos periféricos, bem como doença macrovascular nas artérias. A composição da saliva também é afetada pela DM, com consequências na homeostasia oral. No entanto, o proteoma e o peptidoma salivar têm sido pouco explorados na DM tipo 1 e nas suas complicações crónicas. Tendo em conta o crescente interesse na saliva como fluido diagnóstico, o objetivo principal deste trabalho foi avaliar os eventos proteolíticos subjacentes à DM tipo 1 e às suas complicações microvasculares, bem como, caracterizar as alterações induzidas pela DM tipo 1 no proteoma e peptidoma salivar. A DM tipo 1 e particularmente as complicações microvasculares associadas modulam o perfil proteolítico dos fluidos biológicos, com diferenças significativas de atividade observadas na urina e saliva, atribuídas principalmente ao complexo Metaloproteinase da Matriz (MMP)-9/lipocalina associada à gelatinase de neutrófilos, aminopeptidase N, azurocidina e calicreína 1. O aumento da atividade proteolítica observado na saliva total dos diabéticos resultou no aumento da percentagem de péptidos, principalmente de um número acrescido de fragmentos de colagénio do tipo I, refletindo possivelmente um estado inflamatório crónico dos tecidos orais e periodontais. O peptidoma também corrobora uma maior suscetibilidade das proteínas salivares, especificamente, das proteínas ricas em prolina básicas (bPRP) 1, bPRP2 e proteínas ricas em prolina ácidas (aPRP) à proteólise, evidenciando a geração de fragmentos de proteínas associadas à ligação a bactérias. A análise do proteoma salivar baseada em iTRAQ mostrou uma sobre-expressão de L-plastina, fator do adenocarcinoma do pâncreas e das proteínas S100-A8 e S100-A9, enfatizando a importância do sistema imune inato na patogénese da DM tipo 1 e das complicações microvasculares associadas. A análise integrada de todas as proteínas expressas diferencialmente entre os pacientes diabéticos com ou sem complicações microvasculares e indivíduos saudáveis foi realizada com o STRING, onde se observam três conjuntos funcionalmente ligados, um compreende a interação entre o colagénio tipo I, colagénio tipo II e MMP-9, um segundo conjunto envolve a MMP-2 e o colagénio de tipo I e um terceiro conjunto composto por proteínas salivares e inflamatórias. Estes conjuntos estão associados com as vias Kegg de interação recetor-matriz extracelular, de adesão focal e migração transendotelial dos leucócitos. Por outro lado, a análise do proteoma e peptidoma salivar destacou potenciais biomarcadores para o diagnóstico e prognóstico da DM tipo 1 e das suas complicações.
Resumo:
Bioactive glasses and glass-ceramics are a class of third generation biomaterials which elicit a special response on their surface when in contact with biological fluids, leading to strong bonding to living tissues. The purpose of the present study was to develop diopside based alkali-free bioactive glasses in order to achieve good sintering behaviour, high bioactivity, and a dissolution/ degradation rates compatible with the target applications in bone regeneration and tissue engineering. Another aim was to understand the structure-property relationships in the investigated bioactive glasses. In this quest, various glass compositions within the Diopside (CaMgSi2O6) – Fluorapatite (Ca5(PO4)3F) – Tricalcium phosphate (3CaO•P2O5) system have been investigated. All the glasses were prepared by melt-quenching technique and characterized by a wide array of complementary characterization techniques. The glass-ceramics were produced by sintering of glass powders compacts followed by a suitable heat treatment to promote the nucleation and crystallization phenomena. Furthermore, selected parent glass compositions were doped with several functional ions and an attempt to understand their effects on the glass structure, sintering ability and on the in vitro bio-degradation and biomineralization behaviours of the glasses was made. The effects of the same variables on the devitrification (nucleation and crystallization) behaviour of glasses to form bioactive glass-ceramics were also investigated. Some of the glasses exhibited high bio-mineralization rates, expressed by the formation of a surface hydroxyapatite layer within 1–12 h of immersion in a simulated body fluid (SBF) solution. All the glasses showed relatively lower degradation rates in comparison to that of 45S5 Bioglass®. Some of the glasses showed very good in vitro behaviour and the glasses co-doped with zinc and strontium showed an in vitro dose dependent behaviour. The as-designed bioactive glasses and glass–ceramic materials are excellent candidates for applications in bone regeneration and for the fabrication of scaffolds for tissue engineering.
Resumo:
Bioactive glasses and glass–ceramics are a class of biomaterials which elicit special response on their surface when in contact with biological fluids, leading to strong bonding to living tissue. This particular trait along with good sintering ability and high mechanical strength make them ideal materials for scaffold fabrication. The work presented in this thesis is directed towards understanding the composition-structure-property relationships in potentially bioactive glasses designed in CaOMgOP2O5SiO2F system, in some cases with added Na2O. The main emphasis has been on unearthing the influence of glass composition on molecular structure, sintering ability and bioactivity of phosphosilicate glasses. The parent glass compositions have been designed in the primary crystallization field of the pseudo-ternary system of diopside (CaO•MgO•2SiO2) – fluorapatite (9CaO•3P2O5•CaF2) – wollastonite (CaO•SiO2), followed by studying the impact of compositional variations on the structure-property relationships and sintering ability of these glasses. All the glasses investigated in this work have been synthesized via melt-quenching route and have been characterized for their molecular structure, sintering ability, chemical degradation and bioactivity using wide array of experimental tools and techniques. It has been shown that in all investigated glass compositions the silicate network was mainly dominated by Q2 units while phosphate in all the glasses was found to be coordinated in orthophosphate environment. The glass compositions designed in alkali-free region of diopside – fluorapatite system demonstrated excellent sintering ability and good bioactivity in order to qualify them as potential materials for scaffold fabrication while alkali-rich bioactive glasses not only hinder the densification during sintering but also induce cytotoxicity in vitro, thus, are not ideal candidates for in vitro tissue engineering. One of our bioglass compositions with low sodium content has been tested successfully both in vivo and in preliminary clinical trials. But this work needs to be continued and deepened. The dispersing of fine glass particles in aqueous media or in other suitable solvents, and the study of the most important factors that affect the rheology of the suspensions are essential steps to enable the manufacture of porous structures with tailor-made hierarchical pores by advanced processing techniques such as Robocasting.
Resumo:
According to the World Health Organization, around 8.2 million people die each year with cancer. Most patients do not perform routine diagnoses and the symptoms, in most situations, occur when the patient is already at an advanced stage of the disease, consequently resulting in a high cancer mortality. Currently, prostate cancer is the second leading cause of death among males worldwide. In Portugal, this is the most diagnosed type of cancer and the third that causes more deaths. Taking into account that there is no cure for advanced stages of prostate cancer, the main strategy comprises an early diagnosis to increase the successful rate of the treatment. The prostate specific antigen (PSA) is an important biomarker of prostate cancer that can be detected in biological fluids, including blood, urine and semen. However, the commercial kits available are addressed for blood samples and the commonly used analytical methods for their detection and quantification requires specialized staff, specific equipment and extensive sample processing, resulting in an expensive process. Thus, the aim of this MSc thesis consisted on the development of a simple, efficient and less expensive method for the extraction and concentration of PSA from urine samples using aqueous biphasic systems (ABS) composed of ionic liquids. Initially, the phase diagrams of a set of aqueous biphasic systems composed of an organic salt and ionic liquids were determined. Then, their ability to extract PSA was ascertained. The obtained results reveal that in the tested systems the prostate specific antigen is completely extracted to the ionic-liquid-rich phase in a single step. Subsequently, the applicability of the investigated ABS for the concentration of PSA was addressed, either from aqueous solutions or urine samples. The low concentration of this biomarker in urine (clinically significant below 150 ng/mL) usually hinders its detection by conventional analytical techniques. The obtained results showed that it is possible to extract and concentrate PSA, up to 250 times in a single-step, so that it can be identified and quantified using less expensive techniques.
Resumo:
According to the World Health Organization, around 8.2 million people die each year with cancer. Most patients do not perform routine diagnoses and the symptoms, in most situations, occur when the patient is already at an advanced stage of the disease, consequently resulting in a high cancer mortality. Currently, prostate cancer is the second leading cause of death among males worldwide. In Portugal, this is the most diagnosed type of cancer and the third that causes more deaths. Taking into account that there is no cure for advanced stages of prostate cancer, the main strategy comprises an early diagnosis to increase the successful rate of the treatment. The prostate specific antigen (PSA) is an important biomarker of prostate cancer that can be detected in biological fluids, including blood, urine and semen. However, the commercial kits available are addressed for blood samples and the commonly used analytical methods for their detection and quantification requires specialized staff, specific equipment and extensive sample processing, resulting in an expensive process. Thus, the aim of this MSc thesis consisted on the development of a simple, efficient and less expensive method for the extraction and concentration of PSA from urine samples using aqueous biphasic systems (ABS) composed of ionic liquids. Initially, the phase diagrams of a set of aqueous biphasic systems composed of an organic salt and ionic liquids were determined. Then, their ability to extract PSA was ascertained. The obtained results reveal that in the tested systems the prostate specific antigen is completely extracted to the ionic-liquid-rich phase in a single step. Subsequently, the applicability of the investigated ABS for the concentration of PSA was addressed, either from aqueous solutions or urine samples. The low concentration of this biomarker in urine (clinically significant below 150 ng/mL) usually hinders its detection by conventional analytical techniques. The obtained results showed that it is possible to extract and concentrate PSA, up to 250 times in a single-step, so that it can be identified and quantified using less expensive techniques.
Resumo:
Este trabalho descreve o desenvolvimento de um material sensor para creatinina por impressão molecular em estrutura polimérica (MIP) e a sua aplicação no desenvolvimento de um dispositivo de natureza potenciométrica para a determinação da molécula alvo em fluidos biológicos. A creatinina é um dos biomarcadores mais utilizados no acompanhamento da doença renal, já que é um bom indicador da taxa de filtração glomerular (TFG). Os materiais biomiméticos desenhados para interação com a creatinina foram obtidos por polimerização radicalar, recorrendo a monómeros de ácido metacríclico ou de vinilpiridina e a um agente de reticulação apropriado. De modo a aferir o efeito da impressão da creatinina na resposta dos materiais MIP à sua presença, foram também preparados e avaliados materiais de controlo, obtidos sem impressão molecular (NIP). O controlo da constituição química destes materiais, incluindo a extração da molécula impressa, foi realizado por Espectroscopia de Raman e de Infravermelho com Transformada de Fourrier. A afinidade de ligação entre estes materiais e a creatinina foi também avaliada com base em estudos cinéticos. Todos os materiais descritos foram integrados em membranas selectivas de elétrodos seletivos de ião, preparadas sem ou com aditivo iónico lipófilo, de carga negativa ou positiva. A avaliação das características gerais de funcionamento destes elétrodos, em meios de composição e pH diferentes, indicaram que as membranas com materiais impressos e aditivo aniónico eram as únicas com utilidade analítica. Os melhores resultados foram obtidos em solução tampão Piperazine-N,N′-bis(2- ethanesulfonic acid), PIPES, de pH 2,8, condição que permitiu obter uma resposta quasi-Nernstiana, a partir de 1,6×10-5 mol L-1. Estes elétrodos demonstraram ainda uma boa selectividade ao apresentaram uma resposta preferencial para a creatinina quando na presença de ureia, carnitina, glucose, ácido ascórbico, albumina, cloreto de cálcio, cloreto de potássio, cloreto de sódio e sulfato de magnésio. Os elétrodos foram ainda aplicados com sucesso na análise de amostras sintéticas de urina, quando os materiais sensores eram baseados em ácido metacrilico, e soro, quando os materiais sensores utilizados eram baseados em vinilpiridina.
Resumo:
As leishmanioses caracterizam-se por um espectro de doenças distribuídas endemicamente em regiões tropicais e subtropicais do mundo. A obtenção de material biológico para análise diagnóstica apresenta cuidados cruciais ao paciente, por se tratar de um processo invasivo, passível de inflamação, e podendo haver reativação da doença, em alguns casos. Diante do avanço das técnicas moleculares e da utilização de alguns fluidos biológicos para o diagnóstico da Leishmaniose Tegumentar Americana (LTA), cogitou-se a possibilidade da identificação de DNA de Leishmania spp. em saliva através do método de coleta de swab, sendo contribuinte para o avanço no diagnóstico laboratorial. Assim, o propósito do estudo foi a identificação de DNA de Leishmania spp. a partir do diagnóstico molecular. Foram incluídos no estudo os pacientes que apresentaram lesões ativas, diagnósticos clínicos para LTA, antecedentes epidemiológicos compatíveis e não possuíam lesões cutâneo mucosas. O diagnóstico laboratorial envolveu a abordagem parasitológica através da pesquisa direta do parasito em amostras escarificadas de lesões, enquanto que o molecular compreendeu a extração do DNA das amostras de biópsia e swab salivar, seguidas da reação de PCR convencional (cPCR) e PCR em tempo real (qPCR). Foram investigados 40 pacientes com LTA havendo ocorrência de DNA do parasito em 10 amostras de saliva com cPCR, e 36 amostras utilizando qPCR. Em 28 amostras de biópsias também foi possível a detecção do DNA de Leishmania spp. e em 35 amostras de escarificado de lesão foram encontradas formas amastigotas do parasito, através de pesquisa direta. Na comparação entre os métodos propostos, a biópsia apresentou uma média de 50 por cento de compatibilidade em relação a cPCR e 67,5 por cento para a qPCR. A análise comparativa observou entre o diagnóstico parasitológico e os diagnósticos moleculares uma concordância de 32,5 por cento (14/40) em relação a cPCR, enquanto que a qPCR obteve 75,5 por cento (31/40) de concordância. Considerando a sensibilidade das técnicas de PCR utilizadas e o procedimento de coleta, através de swab advindo de fluidos salivares, os resultados demonstram a viabilidade do método de coleta de Leishmania spp. como uma nova abordagem diagnóstica auxiliar para a LTA, com benefícios à saúde do paciente
Resumo:
Com a realização deste trabalho, pretendeu-se traçar o perfil padrão da composição volátil típico de fluidos biológicos (urina) de indivíduos sem patologia oncológica (grupo de controlo) comparando-os com os de pacientes (grupo com patologia oncológica). As amostras de urina de ambos os grupos foram analisadas por microextracção em fase sólida em modo de headspace acoplada à espectrometria de massa (HS-SPME-GC/qMS). Com o intuito de aumentar a eficiência de extracção da SPME, foram optimizados alguns parâmetros com influência no processo extractivo, nomeadamente o tipo de fibra, o tempo e a temperatura de extracção. Assim sendo, foram testadas e comparadas seis fibras comercialmente disponíveis, polidimetilsiloxano (PDMS, 100 m), poliacrilato (PA, 85 m), carboxeno-polidimetilsiloxano (CAR/PDMS, 75 m), carbowax-divinilbenzeno (CW/DVB, 65 m), divinilbenzeno-carboxen-polidimetilsiloxano (DVB/CAR/PDMS, 50/30 m) e polidimetilsiloxano-divinilbenzeno (PDMS/DVB, 65 m). A influência do tempo (30, 45, 60 e 75 min) e temperatura (30, 50 e 60 ºC) de extracção foram optimizados de modo a obter uma melhor eficiência de extracção dos compostos voláteis presentes nas amostras de urina. Os melhores resultados foram obtidos usando a fibra carboxeno-polidimetilsiloxano (CAR/PDMS, 75 m), com uma velocidade de agitação de 800 rpm durante 75 min a uma temperatura de 50 ºC. Para os dois grupos em estudo, foram identificados 80 compostos voláteis pertencentes a diversas famílias químicas, nomeadamente, aldeídos, cetonas, derivados benzénicos, compostos terpénicos, ácidos orgânicos, compostos furânicos, compostos sulfurados, fenóis voláteis, ésteres, álcoois superiores e derivados do naftaleno. Os compostos maioritários pertencentes aos grupos analisados foram a 4-heptanona, a 2-pentanona, a acetona, a 2-butanona, o 1(2- furanil)etanona, o 3-metil-3-fenil-2-propenal, o 3,4-dimetilbenzaldeído, o decanal, o dissulfureto de dimetilo, o metanotiol, o 2-metoxitiofeno, o 4-metil-fenol, o p-tert-butil-fenol, o 2,4-bis(1,1- dimetiletil)fenol, o fenol, o m-cimeno, o p-cimeno, o tolueno, o 1-etil-3,5-diisopropilbenzeno, o 2,6-dimetil-7-octen-2-ol, a D-carvona, o vitispirano I e o vitispirano II. O teste One-Way ANOVA foi aplicado aos resultados com o intuito de verificar se existiam diferenças significativas entre os grupos avaliados (Controlo e Oncológico), sendo o dissulfureto de dimetilo, o 2-metoxitiofeno, e o p-cimeno estatisticamente significativos. A aplicação da análise multivariável às amostras de urina das diferentes patologias permitiu diferenciá-las no qual se obteve 81,02% da variância total.A aplicação da análise multivariável às amostras de urina das diferentes patologias permitiu diferenciá-las no qual se obteve 81,02% da variância total. A patologia de Hodgkin é influenciada pelas variáveis heptanal e o 2-metil-3-fenil-2-propenal. O Controlo é afectado essencialmente pelas variáveis p-cimeno, 1,4,5-trimetilnaftaleno e o dissulfureto de dimetilo. O Cólon é influenciado pelo 4-metilfenol, anisole e 1,2-dihidro-1,1,6-trimetil-naftaleno. O 1-octanol e a 3-heptanona influenciam, essencialmente as patologias da Mama e Leucemia.
Resumo:
Com este trabalho pretendeu-se estabelecer o perfil metabolómico volátil de amostras de fluidos biológicos, nomeadamente saliva e urina, de pacientes com cancro da mama e do pulmão e de indivíduos saudáveis (grupo controlo), utilizando a Microextração em Fase Sólida em modo headspace (HS-SPME) seguida de Cromatografia Gasosa acoplada à Espectrometria de Massa (GC-MS). Efetuou-se a comparação entre os perfis voláteis dos grupos estudados com o objetivo de identificar metabolitos que possam ser considerados como potenciais biomarcadores dos tipos de cancro em estudo. De modo a otimizar a metodologia extrativa, HS-SPME, foram avaliados os diferentes parâmetros experimentais com influência no processo extrativo. Os melhores resultados foram obtidos com a fibra CAR/PDMS, usando um volume de 2 mL de saliva acidificada, 10% NaCl (m/v) e 45 minutos de extração a uma temperatura de 37±1°C. Para a urina foi utilizada a mesma fibra, 4 mL de urina acidificada, 20% NaCl (m/v) e 60 minutos de extração a 50±1°C. Nas amostras de saliva e urina, foram identificados 243 e 500 metabolitos voláteis respetivamente, sendo estes pertencentes a diferentes famílias químicas. Posteriormente, utilizou-se a análise discriminante por mínimos quadrados parciais (PLS-DA) que permitiu observar uma boa separação entre os grupos controlo e oncológicos. Nas amostras salivares o grupo de pacientes com cancro da mama foi maioritariamente caracterizado pelo metabolito ácido benzeno carboxílico e o grupo de pacientes com cancro do pulmão pelo ácido hexanóico. Na urina o grupo de pacientes com cancro da mama foi maioritariamente caracterizado pelo metabolito 1-[2-(Isobutiriloxi)-1-metiletil]-2,2-dimetilpropil 2-metilpropanoato e o grupo de pacientes com cancro do pulmão pelo o-cimeno. Além da metodologia PLS-DA foi realizada a validação cruzada de monte carlo (MCCV) tendo-se obtido uma elevada taxa de classificação, sensibilidade e especificidade o que demonstra a robustez dos dados obtidos.
Resumo:
In this work, the quantitative analysis of glucose, triglycerides and cholesterol (total and HDL) in both rat and human blood plasma was performed without any kind of pretreatment of samples, by using near infrared spectroscopy (NIR) combined with multivariate methods. For this purpose, different techniques and algorithms used to pre-process data, to select variables and to build multivariate regression models were compared between each other, such as partial least squares regression (PLS), non linear regression by artificial neural networks, interval partial least squares regression (iPLS), genetic algorithm (GA), successive projections algorithm (SPA), amongst others. Related to the determinations of rat blood plasma samples, the variables selection algorithms showed satisfactory results both for the correlation coefficients (R²) and for the values of root mean square error of prediction (RMSEP) for the three analytes, especially for triglycerides and cholesterol-HDL. The RMSEP values for glucose, triglycerides and cholesterol-HDL obtained through the best PLS model were 6.08, 16.07 e 2.03 mg dL-1, respectively. In the other case, for the determinations in human blood plasma, the predictions obtained by the PLS models provided unsatisfactory results with non linear tendency and presence of bias. Then, the ANN regression was applied as an alternative to PLS, considering its ability of modeling data from non linear systems. The root mean square error of monitoring (RMSEM) for glucose, triglycerides and total cholesterol, for the best ANN models, were 13.20, 10.31 e 12.35 mg dL-1, respectively. Statistical tests (F and t) suggest that NIR spectroscopy combined with multivariate regression methods (PLS and ANN) are capable to quantify the analytes (glucose, triglycerides and cholesterol) even when they are present in highly complex biological fluids, such as blood plasma