18 resultados para flapless
Resumo:
Aim To compare the remodeling of the alveolar process at implants installed immediately into extraction sockets by applying a flap or a ""flapless"" surgical approach in a dog model. Material and methods Implants were installed immediately into the distal alveoli of the second mandibular premolars of six Labrador dogs. In one side of the mandible, a full-thickness mucoperiosteal flap was elevated (control site), while contra-laterally, the mucosa was gently dislocated, but not elevated (test site) to disclose the alveolar crest. After 4 months of healing, the animals were sacrificed, ground sections were obtained and a histomorphometric analysis was performed. Results After 4 months of healing, all implants were integrated (n=6). Both at the test and at the control sites, bone resorption occurred with similar outcomes. The buccal bony crest resorption was 1.7 and 1.5 mm at the control and the test sites, respectively. Conclusions ""Flapless"" implant placement into extraction sockets did not result in the prevention of alveolar bone resorption and did not affect the dimensional changes of the alveolar process following tooth extraction when compared with the usual placement of implants raising mucoperiosteal flaps. To cite this article:Caneva M, Botticelli D, Salata LA, Souza SLS, Bressan E, Lang NP. Flap vs. ""flapless"" surgical approach at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 21, 2010; 1314-1319.doi: 10.1111/j.1600-0501.2009.01959.x.
Resumo:
AimTo compare the remodeling of the alveolar process at implants installed immediately into extraction sockets by applying a flap or a "flapless" surgical approach in a dog model.Material and methodsImplants were installed immediately into the distal alveoli of the second mandibular premolars of six Labrador dogs. In one side of the mandible, a full-thickness mucoperiosteal flap was elevated (control site), while contra-laterally, the mucosa was gently dislocated, but not elevated (test site) to disclose the alveolar crest. After 4 months of healing, the animals were sacrificed, ground sections were obtained and a histomorphometric analysis was performed.ResultsAfter 4 months of healing, all implants were integrated (n=6). Both at the test and at the control sites, bone resorption occurred with similar outcomes. The buccal bony crest resorption was 1.7 and 1.5 mm at the control and the test sites, respectively.Conclusions"Flapless" implant placement into extraction sockets did not result in the prevention of alveolar bone resorption and did not affect the dimensional changes of the alveolar process following tooth extraction when compared with the usual placement of implants raising mucoperiosteal flaps.To cite this article:Caneva M, Botticelli D, Salata LA, Souza SLS, Bressan E, Lang NP. Flap vs. "flapless" surgical approach at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 21, 2010; 1314-1319.doi: 10.1111/j.1600-0501.2009.01959.x.
Resumo:
Background: This article describes a clinical report with a new system for guided surgical treatment and immediate load prosthesis in the flapless surgical technique. Case report: Based on a computed tomography (CT) of a 64 - year-old edentulous patient, the cross sections were reformatted and used to construct a virtual planning of the implants and a guide template in Dental Slice. Six dental implants were placed in the maxilla and mandible using a Slice Guide System. Following a 30-month in maxilla and 24-month in mandible healing period, the clinical and radiographic evaluation and computed tomography (CT) showed good clinical stability. The Slice Guide System proved satisfactory for the Flapless Surgical Technique in dental implants.
Resumo:
Aim: Clinical data are scarce on flapless-guided surgery in the mandible using the all-on-four concept. In addition, limited documentation exists on the latter under immediate loading conditions with a pre-fabricated implant bridge. The aim was to provide detailed documentation focusing on clinical and radiographic outcome and complications. Material and methods: Sixteen systemically healthy non-smoking patients (10 women, 6 men, average age 59 years) with sufficient bone volume in the mandible were operated via flapless-guided surgery using the all-on-four concept. Clinical and radiographic data and complications were registered at 3, 6 and 12 months. Results: The overall implant survival rate was 90% with a trend for higher failure of short implants (P = 0.098). The mean bone level after 12 months of function was 0.83 mm with a maximum of 1.07 mm. Technical complications were common (15/16 patients). These mainly related to a misfit between the pre-fabricated prosthesis and abutment(s) (13/16 patients). Conclusion: If immediate loading of implants is pursued fabrication of the implant bridge should be based on actual impression of the implants at the time of surgery and not on their virtual position. © 2011 John Wiley & Sons A/S.
Resumo:
Background: Excessive gingival display (EGD) has a negative impact on a pleasant smile. Minimally invasive therapeutic modalities have become the standard treatment in many dentistry fields. Therefore, the aim of this study is to compare the clinical outcomes of open-flap (OF) and minimally invasive flapless (FL) esthetic crown lengthening (ECL) for the treatment of EGD.Methods: A split-mouth randomized controlled trial was conducted in 28 patients presenting with EGD. Contralateral quadrants received ECL using OF or FL techniques. Clinical parameters were evaluated at baseline and 3, 6, and 12 months post-surgery. The local levels of receptor activator of nuclear factor-kappa B ligand (RANKL) and osteoprotegerin (OPG) were assessed by enzyme-linked immunosorbent assay at baseline and 3 months. Patients' perceptions regarding morbidity and esthetic appearance were also evaluated. Periodontal tissue dimensions were obtained by computed tomography at baseline and correlated with the changes in the gingival margin (GM).Results: Patients reported low morbidity and high satisfaction with esthetic appearance for both procedures (P > 0.05). RANKL and OPG concentrations were increased in the OF group at 3 months (P < 0.05). Probing depths were reduced for both groups at all time points, compared with baseline (P < 0.05). There were no differences between groups for GM reduction at any time point (P > 0.05).Conclusions: FL and OF surgeries produced stable and similar clinical results up to 12 months. FL ECL may be a predictable alternative approach for the treatment of EGD.
Resumo:
The oral rehabilitation with osseointegrated implants is a well-documented treatment with high rate of success. Nevertheless, demands related to treatment time and surgical technique began to appear. In this context, the procedure of immediate loading in which the dental prosthesis is placed right after implant surgery has become a constant practice. Although immediate loading has been an important advance, minimally invasive procedures, such as implant placement without raising a mucoperiosteal flap (flapless) are increasingly being performed. Association of immediate loading with the flapless technique improves acceptance by patients and professionals, because no suturing is required. Moreover, it reduces swelling, bleeding during and after surgery, postoperative pain, surgery time, discomfort and hematoma, as well as the need for postoperative medication. These characteristics ease the stages of rehabilitation soon after implant placement, cooperating with prosthodontist's work. Thus, the proposal of this study is to present a clinical case of oral rehabilitation with osseointegrated implants and fixed prosthesis in both arches, in which the flapless technique was applied, followed by immediate loading. It will discuss the diagnosis, prosthetic planning, surgical/prosthodontic procedures and follow-up for 20 months.
Resumo:
Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.
Resumo:
Background: Resonance frequency analysis (RFA) is a noninvasive technique for the quantitative assessment of implant stability. Information on the implant stability quotient (ISQ) of transmucosally inserted implants is limited. Purpose: The aim of this investigation was to compare the ISQ of conventionally inserted implants by raising a muco-periostal flap with implants inserted using a flapless procedure. Materials and Methods: Forty elderly patients with complete edentulous maxilla were consecutively admitted for treatment with implant-supported prostheses. A computer tomography was obtained for the computer-assisted implant planning. One hundred ten implants were placed conventionally in 23 patients (flap-group) and 85 implants in 17 patients by means of the flapless method (flapless-group) using a stereolithographic template. RFA measurements were performed after implant placement (baseline) and after a healing time of 12 weeks (reentry). Results: All implants exhibited clinically and radiographically successful osseointegration. Bone level did not change significantly neither for genders nor type of surgical protocol. Mean ISQ values of the flapless-group were significantly higher at baseline (p < .001) and at reentry (p < .001) compared with the flap-group. The ISQ values were significantly lower at reentry compared with baseline for the flap-group (p = .028) but not for the flapless-group. This group showed a moderate, but insignificant increase. RFA measurements of males resulted in ISQ values that were thoroughly higher as compared with females at both time-points in both groups. Correlation between RFA and bone level was not found. Conclusions: The flapless procedure showed favorable conditions with regard to implant stability and crestal bone level. Some changes of the ISQ values that represent primary (mechanical) and secondary (bone remodeling) implant stability were observed in slight favor of the flapless method and male patients. In properly planned and well-selected cases, the minimal invasive transmucosal technique using a drill-guide is a safe procedure.
Resumo:
The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.
Resumo:
Aim: To validate the platform switching concept at oral implants with respect to the preservation of the alveolar crestal bone levels in an animal model. Material & methods: Five minipigs received three implants each with a 0.25mm implant/ abutment mismatch and were placed flush (T(0)), 1 mm below (T(1)) and 1 mm above (T(+1)) the alveolar bony crest, and as a control, one conventionally restored implant placed at the bone level. The implants were randomly inserted flapless into the mandible. Four months after implant insertion, the animals were sacrificed, and undecalcified block sections were obtained and used for histological analyses. Results: The mean values for peri- implant bone resorption were 1.09 +/- 0.59mm (Control), 0.51 (+/- 0.27 mm, T(0)), 0.50 (+/- 0.46 mm, T(1)) and 1.30 (+/- 0.21 mm, T (+1)), respectively. Statistically significant differences (P< 0.05) were found among the test (T(0), T(-1)) and the control sites. Control implants presented an average biologic width length of 3.20mm (+/- 0.33), with a connective tissue adaptation compartment of 1.29mm (+/- 0.53) and an epithelial attachment of 1.91 mm (+/- 0.71). T(0), T(1) and T(+1) implants presented with a mean biologic width of 1.97mm (+/- 1.20), 2.70 mm (+/- 1.36) and 2.84mm (+/- 0.90), respectively, with a connective tissue adaptation compartment of 1.21mm (+/- 0.97), 1.21 mm (+/- 0.65) and 1.50 mm (+/- 0.70) and an epithelial attachment of 0.84 mm (+/- 0.93), 1.66 mm (+/- 0.88) and 1.35 mm (+/- 0.44), respectively. Differences between the configurations were mainly associated with the length of the epithelial attachment. The epithelial attachment was significantly longer in the C sites than in T(0) (P = 0.014). However, no other differences between configurations were detected. Conclusion: If the implants are positioned at the level of the alveolar bony crest, the platform switching concept may have a minor impact on the length of the epithelial attachment (0.84 vs. 1.91 mm), while the connective tissue adaptation compartment remains relatively unaffected. Moreover, platform switching resulted in less resorption of the alveolar crest (0.58 mm).
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Resumo:
Introduction: The demand for optimal esthetics has increased with the advance of the implant dentistry and with the desire for easier, safer and faster technique allowing predictable outcomes. Thus, the aim of this case report was to describe a combined approach for the treatment of a periodontally compromised tooth by means of atraumatic tooth extraction, immediate flapless implant placement, autogenous block and particulate bone graft followed by connective tissue graft and immediate provisionalization of the crown in the same operatory time. Case Report: A 27-year-old woman underwent the proposed surgical procedures for the treatment of her compromised maxillary right first premolar. The tooth was removed atraumatically with a periotome without incision. A dental implant was inserted 3 mm apical to the cement-enamel junction of the adjacent teeth enabling the ideal tridimensional implant position. An osteotomy was performed in the maxillary tuber for block bone graft harvesting that allowed the reconstruction of the alveolar buccal plate. Thereafter, an autogenous connective tissue graft was placed to increase both the horizontal and vertical dimensions of the alveolar socket reaching the patient functional and esthetic expectations. Conclusion: This treatment protocol was efficient to create a harmonious gingival architecture with sufficient width and thickness, maintaining the stability of the alveolar bone crest yielding excellent aesthetic results after 2-years of follow-up. We suggest that this approach can be considered a viable alternative for the treatment of periodontally compromised tooth in the maxillary esthetic area enhancing patient comfort and satisfaction.
Resumo:
ObjectiveThe aim of this clinical report was to reestablish the buccal bone wall after immediate implant placement. The socket defect was corrected with autogenous bone, and a connective tissue graft was removed from the maxillary tuberosity to increase the thickness, height, and width of the buccal bone and gingival tissue followed by immediate provisionalization of the crown during the same operation.Clinical ConsiderationsA 66-year-old patient presented with a hopeless maxillary left central incisor with loss of the buccal bone wall. Atraumatic, flapless extraction was performed, and an immediate implant was placed in the extraction socket followed by preparation of an immediate provisional restoration. Subsequently, immediate reconstruction of the buccal bone plate was performed, using the tuberosity as the donor site, to obtain block bone and connective tissue grafts, as well as particulate bone. Finally, immediate provisionalization of the crown followed by simple sutures was performed. Cone-beam computed tomography and periapical radiographs were taken before and after surgery. After 4 months, the final prosthetic crown was made. After a 2-year follow-up, a satisfactory aesthetic result was achieved with lower treatment time and morbidity.ConclusionThis case demonstrates the effective use of immediate reconstruction of the buccal bone wall for the treatment of a hopeless tooth in the maxillary aesthetic area. This procedure efficiently promoted harmonious gingival and bone architecture, recovered lost anatomical structures with sufficient width and thickness, and maintained the stability of the alveolar bone crest in a single procedure.Clinical SignificanceIf appropriate clinical conditions exist, immediate dentoalveolar restoration may be the most conservative means of reconstructing the buccal bone wall after immediate implant placement followed by immediate provisionalization with predictable healing and lower treatment time.
Resumo:
Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.