964 resultados para five-bottle test
Resumo:
National Highway Traffic Safety Administration, Accident Investigation Division, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Accident Investigation Division, Washington, D.C.
Resumo:
The aim of this work was to test mineral preference in hydrated rats that received a pulse intracerebroventricular (icv(p)) injection of ANG II at a dipsogenic dose (50 ng). The icv(p) ANG II induced a four-fold higher ingestion of 0.15 M NaHCO(3) than of other mineral solutions at palatable concentrations (0.15 M NaCl, 0.05 mM CaCl(2) and 0.01 M KCl) in a five-bottle test with water available in a fifth bottle; water intake was not consistently high in this test. Contrary to what is predicted by the mineralocorticoid/angiotensin II synergy hypothesis, the 0.15 M NaCl intake in the five-bottle test was not enhanced by icvp ANG H preceded by deoxycorticosterone (DOCA) treatment (2.5 mg/day for 3 days); neither was the NaHCO(3) intake. This result contrasted with the vigorous ingestion of both isotonic sodium solutions, but mostly of NaCl, rather than of other fluids, by sodium-depleted (furosemide 10 mg sc + 24 h removal ambient sodium) rats in a sodium appetite test. The results suggest that mineralocorticoid combined to icv(p) ANG II does not simulate the sodium preference shown during sodium appetite. The results also show that a dipsogenic dose of central ANG II induces a reliable ingestion of isotonic sodium bicarbonate in the rat. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Isotonic NaCl is ingested in addition to water by cell-dehydrated rats in two-bottle tests. The objective of the present work was to find out whether mineral intake in the cell-dehydrated rat is specific to NaCl in a five-bottle test. Adult male Sprague Dawley rats had distilled water and four mineral solutions at palatable concentrations (0.01 M KCl, 0.05 mM CaCl2, 0.15 M NaHCO3, 0.15 M NaCl) simultaneously available for consumption. Cell-debydration was produced infusing 1.5 ml of NaCl solution (0.15, 0.25, 0.5, 1.01, 2.0, 4.0 M) intravenously for 10 min and intakes were recorded for the next hour. It was observed a NaCl concentration-dependent increase in 0.01 M KCl intake. The ingestion of the other mineral solutions was not significantly altered compared to infusion of 0.15 M NaCl. The ingestion of KCl was not related to changes in serum potassium concentration. The ingestion of KCl was reduced in half and water was the preferred fluid when the five-bottle test was performed with mineral solutions at isomolar (0.15 M) concentrations. There was no increase in intake of other mineral solution in the isomolar test. No preference was observed for palatable or isomolar solutions during early extracellular dehydration until 4 h after subcutaneous injection of furosemide, in spite of the increase in total volume intake. Therefore, mineral intake induced by cell dehydration is not specific for NaCl solution. The type of mineral solution available influences the choice and KCl. is the preferred solution of the cell-dehydrated rat in the conditions of the present study. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
This study used a homogeneous water-equivalent model of an electronic portal imaging device (EPID), contoured as a structure in a radiotherapy treatment plan, to produce reference dose images for comparison with in vivo EPID dosimetry images. Head and neck treatments were chosen as the focus of this study, due to the heterogeneous anatomies involved and the consequent difficulty of rapidly obtaining reliable reference dose images by other means. A phantom approximating the size and heterogeneity of a typical neck, with a maximum radiological thickness of 8.5 cm, was constructed for use in this study. This phantom was CT scanned and a simple treatment including five square test fields and one off-axis IMRT field was planned. In order to allow the treatment planning system to calculate dose in a model EPID positioned a distance downstream from the phantom to achieve a source-to-detector distance (SDD) of 150 cm, the CT images were padded with air and the phantom’s “body” contour was extended to encompass the EPID contour. Comparison of dose images obtained from treatment planning calculations and experimental irradiations showed good agreement, with more than 90% of points in all fields passing a gamma evaluation, at γ (3%, 3mm )Similar agreement was achieved when the phantom was over-written with air in the treatment plan and removed from the experimental beam, suggesting that water EPID model at 150 cm SDD is capable of providing accurate reference images for comparison with clinical IMRT treatment images, for patient anatomies with radiological thicknesses ranging from 0 up to approximately 9 cm. This methodology therefore has the potential to be used for in vivo dosimetry during treatments to tissues in the neck as well as the oral and nasal cavities, in the head-and-neck region.
Resumo:
Age-related macular degeneration (AMD) affects the central vision and subsequently may lead to visual loss in people over 60 years of age. There is no permanent cure for AMD, but early detection and successive treatment may improve the visual acuity. AMD is mainly classified into dry and wet type; however, dry AMD is more common in aging population. AMD is characterized by drusen, yellow pigmentation, and neovascularization. These lesions are examined through visual inspection of retinal fundus images by ophthalmologists. It is laborious, time-consuming, and resource-intensive. Hence, in this study, we have proposed an automated AMD detection system using discrete wavelet transform (DWT) and feature ranking strategies. The first four-order statistical moments (mean, variance, skewness, and kurtosis), energy, entropy, and Gini index-based features are extracted from DWT coefficients. We have used five (t test, Kullback–Lieber Divergence (KLD), Chernoff Bound and Bhattacharyya Distance, receiver operating characteristics curve-based, and Wilcoxon) feature ranking strategies to identify optimal feature set. A set of supervised classifiers namely support vector machine (SVM), decision tree, k -nearest neighbor ( k -NN), Naive Bayes, and probabilistic neural network were used to evaluate the highest performance measure using minimum number of features in classifying normal and dry AMD classes. The proposed framework obtained an average accuracy of 93.70 %, sensitivity of 91.11 %, and specificity of 96.30 % using KLD ranking and SVM classifier. We have also formulated an AMD Risk Index using selected features to classify the normal and dry AMD classes using one number. The proposed system can be used to assist the clinicians and also for mass AMD screening programs.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
BACKGROUND: The number of nonagenarians and centenarians is rising dramatically, and many of them live in nursing homes. Very little is known about psychiatric symptoms and cognitive abilities other than memory in this population. This exploratory study focuses on anosognosia and its relationship with common psychiatric and cognitive symptoms. METHODS: Fifty-eight subjects aged 90 years or older were recruited from geriatric nursing homes and divided into five groups according to Mini-Mental State Examination scores. Assessment included the five-word test, executive clock-drawing task, lexical and categorical fluencies, Anosognosia Questionnaire-Dementia, Neuropsychiatric Inventory, and Charlson Comorbidity Index. RESULTS: Subjects had moderate cognitive impairment, with mean ± SD Mini-Mental State Examination being 15.41 ± 7.04. Anosognosia increased with cognitive impairment and was associated with all cognitive domains, as well as with apathy and agitation. Subjects with mild global cognitive decline seemed less anosognosic than subjects with the least or no impairment. Neither anosognosia nor psychopathological features were related to physical conditions. CONCLUSIONS: Anosognosia in oldest-old nursing home residents was mostly mild. It was associated with both cognitive and psychopathological changes, but whether anosognosia is causal to the observed psychopathological features requires further investigation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Male adult rats that received an intragastric load of 2 ml of 12% NaCl (n = 13) ingested both water (4.0 +/- 0.2 ml/2 h) and 0.9% NaCl (3.7 +/- 1.0 ml/2 h) when compared with rats that received intragastric load of 2 ml ofwater(water: 0.1 +/- 0.1; 0.9% NaCl: 0.5 +/- 0.3 ml/2 h, n = 12) in a two-bottle test. Intragastric sodium load increased plasma sodium concentration and osmolality by 5% and reduced plasma renin activity by half compared to rats that received intragastric load of water. Intravenous infusion of 1.5 ml/10 min of 10% NaCl (n = 16) also induced ingestion of water (6.2 +/- 0.8 ml/2 h) and 0.9% NaCl (2.9 +/- 0.8 ml/2 h) compared with intravenous infusion of 1.5 ml/10 min of 0.9% NaCl (water: 0.9 +/- 0.4; 0.9% NaCl: 0.5 +/- 0.2 ml/2 h, n = 14). Therefore, a sodium load that raises natremia and plasma osmolality, and therefore induces cell dehydration, results in both 0.9% NaCl and water ingestion when the rats have a two-bottle choice. (C) 2002 Elsevier B.V. All rights reserved.
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Allgemein erlaubt adaptive Gitterverfeinerung eine Steigerung der Effizienz numerischer Simulationen ohne dabei die Genauigkeit des Ergebnisses signifikant zu verschlechtern. Es ist jedoch noch nicht erforscht, in welchen Bereichen des Rechengebietes die räumliche Auflösung tatsächlich vergröbert werden kann, ohne die Genauigkeit des Ergebnisses signifikant zu beeinflussen. Diese Frage wird hier für ein konkretes Beispiel von trockener atmosphärischer Konvektion untersucht, nämlich der Simulation von warmen Luftblasen. Zu diesem Zweck wird ein neuartiges numerisches Modell entwickelt, das auf diese spezielle Anwendung ausgerichtet ist. Die kompressiblen Euler-Gleichungen werden mit einer unstetigen Galerkin Methode gelöst. Die Zeitintegration geschieht mit einer semi-implizite Methode und die dynamische Adaptivität verwendet raumfüllende Kurven mit Hilfe der Funktionsbibliothek AMATOS. Das numerische Modell wird validiert mit Hilfe einer Konvergenzstudie und fünf Standard-Testfällen. Eine Methode zum Vergleich der Genauigkeit von Simulationen mit verschiedenen Verfeinerungsgebieten wird eingeführt, die ohne das Vorhandensein einer exakten Lösung auskommt. Im Wesentlichen geschieht dies durch den Vergleich von Eigenschaften der Lösung, die stark von der verwendeten räumlichen Auflösung abhängen. Im Fall einer aufsteigenden Warmluftblase ist der zusätzliche numerische Fehler durch die Verwendung der Adaptivität kleiner als 1% des gesamten numerischen Fehlers, wenn die adaptive Simulation mehr als 50% der Elemente einer uniformen hoch-aufgelösten Simulation verwendet. Entsprechend ist die adaptive Simulation fast doppelt so schnell wie die uniforme Simulation.