91 resultados para firefighters


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to aqueous film forming foam (AFFF) was evaluated in 149 firefighters working at AFFF training facilities in Australia by analysis of PFOS and related compounds in serum. A questionnaire was designed to capture information about basic demographic factors, lifestyle factors and potential occupational exposure (such as work history and self-reported skin contact with foam). The results showed that a number of factors were associated with PFAA serum concentrations. Blood donation was found to be linked to low PFAA levels, and the concentrations of PFOS and PFHxS were found to be positively associated with years of jobs with AFFF contact. The highest levels of PFOS and PFHxS were one order of magnitude higher compared to the general population in Australia and Canada. Study participants who had worked ten years or less had levels of PFOS that were similar to or only slightly above those of the general population. This coincides with the phase out of 3M AFFF from all training facilities in 2003, and suggests that the exposures to PFOS and PFHxS in AFFF have declined in recent years. Self-reporting of skin contact and frequency of contact were used as an index of exposure. Using this index, there was no relationship between PFOS levels and skin exposure. This index of exposure is limited as it relies on self-report and it only considers skin exposure to AFFF, and does not capture other routes of potential exposure. Possible associations between serum PFAA concentrations and five biochemical outcomes were assessed. The outcomes were serum cholesterol, triglycerides, high-density lipoproteins, low density lipoproteins, and uric acid. No statistical associations between any of these endpoints and serum PFAA concentrations were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A real-time cooperative localization system, utilizing dual foot-mounted low-cost inertial sensors and RF-based inter-agent ranging, has been developed. Scenario-based tests have been performed, using fully-equipped firefighters mimicking a search operation in a partly smoke-filled environment, to evaluate the performance of the TOR (Tactical lOcatoR) system. The performed tests included realistic firefighter movements and inter-agent distances, factors that are crucial in order to provide realistic evaluations of the expected performance in real-world operations. The tests indicate that the TOR system may be able to provide a position accuracy of approximately two to three meters during realistic firefighter operations, with only two smoke diving firefighters and one supervising firefighter within range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variation in hiring procedures occurs within fire service human resource departments. In this study, City 1 and City 2 applicants were required to pass their biophysical assessments prior to being hired as firefighters at the beginning and end of the screening process, respectively. City 1 applicants demonstrated significantly lower resting heart rate (RHR), resting diastolic blood pressure (RDBP), body fat% (BF) and higher z-scores for BF, trunk flexibility (TF) and overall clinical assessment (p<0.05). Regression analysis found that age and conducting the biophysical assessment at the end of the screening process explained poorer biophysical assessment results in BF% (R2=21%), BF z-score (R2=22%), TF z-score (R2=10%) and overall clinical assessment z-score (R2=7%). Each of RHR (OR=1.06, CI=1.01-1.10), RDBP (OR=1.05, CI=1.00-1.11) and BF% (OR=1.20, CI=1.07-1.37) increased the odds of being a City 2 firefighter (p<0.05). Biophysical screening at the end of the hiring process may result in the hiring of a less healthy firefighter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the risks of occupational noise induced hearing loss in firefighters. OSHA and National Institute for Occupational Safety and Health (NIOSH) guidelines are described and noise data collected from the Blue Island (Illinois) Fire Department is analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since fighting fires can pose a great risk to the lives of firefighters, it is important to understand how they perceive risks in dynamic wildfire situations. The aim of the current study was to determine whether career and volunteer firefighters differ in their perception of the risk of a going vs. contained fire and whether descriptions of a fire as either going or contained affected perceptions of risk. It was expected that career firefighters would rate a contained fire as significantly riskier than would volunteer firefighters. The sample consisted of 55 career and 84 volunteer CFA Victorian firefighters (134 males and 5 females). An ambiguous wildfire scenario was presented and described as either going or contained and risk ratings were recorded. Two-way ANOVA results showed that career firefighters rated a going fire as equally risky as a contained fire. On the other hand, volunteer firefighters perceived a fire described as contained to be significantly less risky than a fire described as going, despite the fact that the same fireground conditions were described in both cases. It was concluded that a framing effect had occurred and that career firefighters demonstrated a higher level of situation awareness than volunteer firefighters due to their heightened levels of risk perception when exposed to contained wildfire scenarios. A practical implication of the current research is that those conducting firefighting briefings need to be aware of possible framing effects in the way information is presented to firefighters and need to ensure that all briefings make risks cognitively salient to firefighters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study examined firefighters' ability to consume a prescribed fluid volume (1200 ml · h-1) during a wildland fire suppression shift and compare the effect of this additional fluid prescription with self-paced drinking on firefighters' hydration status and plasma sodium concentration post shift and their heart rate, core temperature and physical activity during their shift. Thirty-four firefighters were evenly divided into two drinking groups: self paced and prescribed. Prescribed drinkers did not meet the required 1200 ml·h-1 intake, yet they consumed twice the fluid drank by the self-paced group. No differences were noted between groups in plasma sodium levels or hydration status before or after their shift. Prescribed fluid consumption resulted in significantly lower core temperature between two and six hours into the shift. This did not coincide with lower cardiovascular strain, greater physical activity when compared to the self-paced drinking group. Additional fluid consumption (above self-paced intake) did not improve firefighter activity or physiological function (though it may buffer rising core temperature). It seems that wildland firefighters, at least in mild to warm weather conditions, can self-regulate their fluid consumption and work behaviour to leave the fireground hydrated at the conclusion of their shift.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study combined, for the first time, video footage of individual firefighters wearing heart rate monitors and personal GPS units to quantify the frequency, duration and intensity of tasks performed by Australian rural fire crews when. suppressing bushfires. Across the four fireground 'shifts', the firefighters performed 34 distinct fireground tasks. Per shift, the task frequency ranged from once (raking fireline in teams, carrying a quick fill pump) to 103 times {lateral repositioning of a 38-mm charged firehose) .. The tasks lasted between 4 ± 2 s (bowling out 3-8-mm firehose) and 461 ± 387 s (raking fireline in teams). The task intensity~ as measured by average heart rate ranged between 97 ± 16 beats·min-1 (55.7 ± 8.7. %HRmax) and 157 ± 15 beats·min-1 (86.2 ± 10.8 %HRmax)· The tasks were performed a speeds that ranged from 0.12 ± 0.08 m·s-1 (manual hose retraction of 38-mm charged firehose) to 0.79 ± 0.40 m·s-1 (carrying a 38-mm coiled hose). Tasks found to be simultaneously frequent, long and intense (or two of these three) are likely to form the basis for job-specific testing of Australian rural firefighters suppressing bushfires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Every year, Australian firefighters protect our nation from the devastation of bushfire. Understanding the impact of consecutive long shifts in hot, smoky conditions is essential for making decisions during campaign fires. At present, the evidence-base for such decisions is limited to laboratory studies with little relevance to bushfire suppression or field research where the impact of environmental and workload stressors cannot be measured. To counter these limitations, we have developed a three-day simulation that mimics the work and environment of campaign bushfire suppression. Construction of the simulation involved three stages; 1) data collection and analysis; 2) design and development; and 3) trial and refinement. The frequency, intensity, duration and type of physical work performed on the fireground is well documented and a modified applied cognitive task analysis, using experienced firefighters was used as a framework to describe in detail the non-physical aspects of the work. The design and development of the simulation incorporated the physical and non-physical aspects of the work into simulated tasks. Finally, experienced firefighters participated in trials of the simulation and reviewed digital recordings to ensure that the simulation accurately represented campaign bushfire suppression work. The outcome of this project is a valid, realistic, and reliable simulation of the physiological, physical and cognitive aspects of a volunteer firefighter on a three-day bushfire deployment.