996 resultados para filtration conditions
Resumo:
We report the singular filtration properties of an ultrafiltration membrane made with mesoporous silica that exhibits cylindrical pores aligned mostly normal to the support. This membrane supported on tubular commercial macroporous alumina supports was prepared by the interfacial growth mechanism between stable silica-surfactant hybrid micelles made of the association of silica oligomers with polyethyleneoxide-based (PEO) surfactants and sodium fluoride, a well-known silica condensation catalyst [Boissière et al., An ultrafiltration membrane made with mesoporous MSU-X silica, Chem. Mater. 15 (2003) 460-463]. It appears that the combined effect of the silica nature of the membrane, whose surface charge can be easily adjusted by changing the pH and the non-connected cylindrical shape of the pores provides a new behavior in the retention properties, as proved by the filtration of polyoxyethylene polymers (PEO) with different molecular weights. Depending on the filtration conditions, a rejection rate of 80% and a steep cut-off at 2000 Da can be obtained or, on the reverse, polymers three times bigger than the pore diameter can diffuse through the membrane. This new filtration mechanism, which opens up new modes of separation modes, is explained in the light of both topology of the porous network and pH-dependent interactions between PEO polymers and silica porous media. © 2004 Elsevier B.V. All rights reserved.
Resumo:
We report preparation and the singular filtration properties of an ultrafiltration membrane made with MSU-type mesoporous silica that exhibits cylindrical pores aligned mostly normal to the support. This membrane supported on tubular commercial macroporous alumina supports was prepared by the interfacial growth mechanism between stable silica-surfactant hybrid micelles made of the association of silica oligomers with polyethyleneoxide-based (PEO) surfactants and sodium fluoride, a well-known silica condensation catalyst. It appears that the combined effect of the silica nature of the membrane, whose surface charge can be easily adjusted by changing the pH and the non-connected cylindrical shape of the pores provides a new behavior in the retention properties, as proved by the filtration of polyoxyethylene polymers (PEO) with different molecular weights. Depending on the filtration conditions, a rejection rate of 80 % and a steep cut-off at 2,000 Da can be obtained or, on the reverse, polymers three times bigger than the pore diameter can diffuse through the membrane. This new filtration mechanism, which opens up new modes of separation modes, is explained in the light of both topology of the porous network and pH-dependent interactions between PEO polymers and silica porous media. © 2005 Elsevier B.V. All rights reserved.
Resumo:
A pilot scale multi-media filtration system was used to evaluate the effectiveness of filtration in removing petroleum hydrocarbons from a source water contaminated with diesel fuel. Source water was artificially prepared by mixing bentonite clay and tap water to produce a turbidity range of 10-15 NTU. Diesel fuel concentrations of 150 ppm or 750 ppm were used to contaminate the source water. The coagulants used included Cat Floc K-10 and Cat Floc T-2. The experimental phase was conducted under direct filtration conditions at constant head and constant rate filtration at 8.0 gpm. Filtration experiments were run until the filter reached its clogging point as noted by a measured peak pressure loss of 10 psi. The experimental variables include type of coagulant, oil concentration and source water. Filtration results were evaluated based on turbidity removal and petroleum hydrocarbon (PHC) removal efficiency as measured by gas chromatography. Experiments indicated that clogging was controlled by the clay loading on the filter and that inadequate destabilization of the contaminated water by the coagulant limited the PHC removal. ^
Resumo:
Tässä työssä tutkittiin suodatukseen vaikuttavien tekijöiden vaikutusta suodatuksessa syntyvän kakun ominaisuuksiin sekä kakun ominaisuuksien vaikutusta syrjäytyspesun tehokkuuteen. Lisäksi määritettiin tärkeimmät suodatusparametrit sekä niiden riippuvuudet suodatusolosuhteista. Toissijaisena tavoitteena oli lisäksi tutkia, miten suodatusolosuhteita ja suodatettavan lietteen ominaisuuksia muuttamalla voidaan vaikuttaa suodatusjakson kestoon. Työn kirjallisuusosassa käsiteltiin aluksi yleisesti kiintoaineen erotusta nesteestä. Tämän jälkeen käsiteltiin yleisimmät suodatustekniikat ja tarkasteltiin yksityiskohtaisemmin painesuodatusta ja varsinkin syntyvän kakun rakenteeseen vaikuttavia tekijöitä. Lopuksi käytiin läpi kakulle suodatuksen jälkeen suoritettavat jälkikäsittelymenetelmät ja selvitettiin varsinkin syrjäytyspesun tehokkuuteen vaikuttavia tekijöitä tarkemmin. Kokeellisessa osassa tehtiin koesuodatuksia lietteellä joka sisälsi hienojakoista pigmenttiä. Koesuodatukset tehtiin kahdella eri kankaalla panostoimisella piston press- laboratoriopainesuodattimella johon oli liitetty tiedonkeruuohjelmisto, joka keräsi tiedostoon paineet suodatuskammiossa, kankaan alapuolella ja työsylinterin syöttölinjassa sekä lisäksi männän korkeuden, lietteen lämpötilan ja suodosvaakalukeman. Lietteiden ominaisuuksia seurattiin analysoimalla niiden kiintoainepitoisuuksia, kloridipitoisuuksia, z-potentiaaleja ja partikkelikokojakau-mia siten että jokaisessa suodatuksessa käytetyn lietteen ominaisuudet olivat tiedossa. Suodatusten jälkeen syntyneistä kakuista määritettiin kiintoaine- sekä joissain tapauksissa myös kloridipitoisuudet. Suodatus- ja puristuspaineiden havaittiin vaikuttavan kakkujen huokoisuuksiin ja ominaisvastuksiin selvästi, joskin muutokset olivat melko pieniä. Vaikutus näkyi selvästi myös suodatusten kestoissa ja muutosten havaittiin olevan merkittävän suuruisia. Myös lietteen pH:n havaittiin vaikuttavan merkitsevästi suodatusten kestoihin ja kakkujen ominaisuuksiin. Pesutuloksen ja kakun ominaisuuksien välille löydettiin riippuvuus heikoksi jääneestä pesutuloksesta huolimatta. Myös koesuodatuksissa käytettyjen kankaiden välillä havaittiin selviä eroavaisuuksia.
Resumo:
Nanofiltration performance was studied with effluents from the pulp and paper industry and with model substances. The effect of filtration conditions and membrane properties on nanofiltration flux, retention, and fouling was investigated. Generally, the aim was to determine the parameters that influence nanofiltration efficiency and study how to carry out nanofiltration without fouling by controlling these parameters. The retentions of the nanofiltration membranes studied were considerably higher than those of tight ultrafiltration membranes, and the permeate fluxes obtained were approximately the same as those of tight ultrafiltration membranes. Generally, about 80% retentions of total carbon and conductivity were obtained during the nanofiltration experiments. Depending on the membrane and the filtration conditions, the retentions of monovalent ions (chloride) were between 80 and 95% in the nanofiltrations. An increase in pH improved retentions considerably and also the flux to some degree. An increase in pressure improved retention, whereas an increase in temperature decreased retention if the membrane retained the solute by the solution diffusion mechanism. In this study, more open membranes fouled more than tighter membranes due to higher concentration polarization and plugging of the membrane material. More irreversible fouling was measured for hydrophobic membranes. Electrostatic repulsion between the membrane and the components in the solution reduced fouling but did not completely prevent it with the hydrophobic membranes. Nanofiltration could be carried out without fouling, at least with the laboratory scale apparatus used here when the flux was below the critical flux. Model substances had a strong form of the critical flux, but the effluents had only a weak form of the critical flux. With the effluents, some fouling always occurred immediately when the filtration was started. However, if the flux was below the critical flux, further fouling was not observed. The flow velocity and pH were probably the most important parameters, along with the membrane properties, that influenced the critical flux. Precleaning of the membranes had only a small effect on the critical flux and retentions, but it improved the permeability of the membranes significantly.
Resumo:
Työssä tutkittiin polymeerisen ultrasuodatuskalvon modifiointimahdollisuuksia prosessiolosuhteita muuttamalla. Kalvon modifioimisella pyritään sen suodatusominaisuuksien muuttumiseen, joka voi lisätä kalvon käyttökohteita ja parantaa kalvon soveltuvuutta tiettyjen yhdisteiden suodatukseen. Hydrofiilisiä, tiukkoja polymeerisiä ultrasuodatuskalvoja on kaupallisesti saatavilla vähän, joten työssä tutkittiin niiden valmistusta modifioimalla markkinoilla olevaa, löysempää, hydrofiilistä, polymeeristä ultrasuodatuskalvoa. Ultrasuodatuskalvo modifioitiin paineen, lämpötilan ja emäksen avulla. Modifioinnin aiheuttamat muutokset voidaan jakaa pysyviin, osittain palautuviin tai palautuviin muutoksiin. Kalvon rakenteen muuttuessa pysyvästi voidaan kalvo modifioida ennen suodatuksen aloittamista. Tällöin modifioinnissa käytetyt olosuhteet eivät vaikuta suodatukseen kuten muissa tapauksissa. Modifioinnin vaikutusta kalvoon voidaan analysoida eri menetelmillä. Näitä ovat esimerkiksi elektronimikroskopia ja kalvon vuon tai retention analysointi. Mikroskooppikuvia ei voida ottaa suodatuksen aikana, vaan kalvosta saada tietoa ainoastaan alku- ja lopputilanteissa suodatusolosuhteista poistettuna. Vuon ja retention avulla saadaan reaaliaikaista tietoa modifioidun kalvon suodatuskapasiteetin ja erotuskyvyn muutoksista. Työssä modifioinnin vaikutusta seurattiin vuo- ja retentiomittausten avulla ja kalvon rakenteessa tapahtuvia muutoksia tutkittiin pyyhkäisyelektronimikroskooppikuvien ja mikrometrimittausten avulla. Korkeampaa painetta tai lämpötilaa käytettäessä havaittiin vuon alenevan modifioitaessa enemmän kuin matalammissa paineissa tai lämpötiloissa. Korkeampi puristuslämpötila kasvatti myös retentiota. Modifiointiolosuhteiden ollessa emäksisiä aleni permeabiliteetti neutraaleissa olosuhteissa tehtyä puristusta enemmän. Myös retentio aleni emäksen avulla tehdyssä modifioinnissa. Kalvon rakenteessa tapahtuneiden muutosten palautuminen riippui modifiointilämpötilasta, korkeassa lämpötilassa modifioidussa kalvossa palautumista ei tapahtunut. Modifioinnin aiheuttamat kalvojen paksuuden muutokset tukivat retentio- ja vuomittauksia. Pyyhkäisyelektronimikroskooppikuvista voitiin havaita kalvon huokosrakenteen puristuneen modifioinnin aikana.
Resumo:
Cooling crystallization is one of the most important purification and separation techniques in the chemical and pharmaceutical industry. The product of the cooling crystallization process is always a suspension that contains both the mother liquor and the product crystals, and therefore the first process step following crystallization is usually solid-liquid separation. The properties of the produced crystals, such as their size and shape, can be affected by modifying the conditions during the crystallization process. The filtration characteristics of solid/liquid suspensions, on the other hand, are strongly influenced by the particle properties, as well as the properties of the liquid phase. It is thus obvious that the effect of the changes made to the crystallization parameters can also be seen in the course of the filtration process. Although the relationship between crystallization and filtration is widely recognized, the number of publications where these unit operations have been considered in the same context seems to be surprisingly small. This thesis explores the influence of different crystallization parameters in an unseeded batch cooling crystallization process on the external appearance of the product crystals and on the pressure filtration characteristics of the obtained product suspensions. Crystallization experiments are performed by crystallizing sulphathiazole (C9H9N3O2S2), which is a wellknown antibiotic agent, from different mixtures of water and n-propanol in an unseeded batch crystallizer. The different crystallization parameters that are studied are the composition of the solvent, the cooling rate during the crystallization experiments carried out by using a constant cooling rate throughout the whole batch, the cooling profile, as well as the mixing intensity during the batch. The obtained crystals are characterized by using an automated image analyzer and the crystals are separated from the solvent through constant pressure batch filtration experiments. Separation characteristics of the suspensions are described by means of average specific cake resistance and average filter cake porosity, and the compressibilities of the cakes are also determined. The results show that fairly large differences can be observed between the size and shape of the crystals, and it is also shown experimentally that the changes in the crystal size and shape have a direct impact on the pressure filtration characteristics of the crystal suspensions. The experimental results are utilized to create a procedure that can be used for estimating the filtration characteristics of solid-liquid suspensions according to the particle size and shape data obtained by image analysis. Multilinear partial least squares regression (N-PLS) models are created between the filtration parameters and the particle size and shape data, and the results presented in this thesis show that relatively obvious correlations can be detected with the obtained models.
Resumo:
The EM3E Master is an Education Programme supported by the European Commission, the European Membrane Society (EMS), the European Membrane House (EMH), and a large international network of industrial companies, research centres and universities
Resumo:
BACKGROUND: Creatinine clearance is the most common method used to assess glomerular filtration rate (GFR). In children, GFR can also be estimated without urine collection, using the formula GFR (mL/min x 1.73 m2) = K x height [cm]/Pcr [mumol/L]), where Pcr represents the plasma creatinine concentration. K is usually calculated using creatinine clearance (Ccr) as an index of GFR. The aim of the present study was to evaluate the reliability of the formula, using the standard UV/P inulin clearance to calculate K. METHODS: Clearance data obtained in 200 patients (1 month to 23 years) during the years 1988-1994 were used to calculate the factor K as a function of age. Forty-four additional patients were studied prospectively in conditions of either hydropenia or water diuresis in order to evaluate the possible variation of K as a function of urine flow rate. RESULTS: When GFR was estimated by the standard inulin clearance, the calculated values of K was 39 (infants less than 6 months), 44 (1-2 years) and 47 (2-12 years). The correlation between the values of GFR, as estimated by the formula, and the values measured by the standard clearance of inulin was highly significant; the scatter of individual values was however substantial. When K was calculated using Ccr, the formula overestimated Cin at all urine flow rates. When calculated from Ccr, K varied as a function of urine flow rate (K = 50 at urine flow rates of 3.5 and K = 64 at urine flow rates of 8.5 mL/min x 1.73 m2). When calculated from Cin, in the same conditions, K remained constant with a value of 50. CONCLUSIONS: The formula GFR = K x H/Pcr can be used to estimate GFR. The scatter of values precludes however the use of the formula to estimate GFR in pathophysiological studies. The formula should only be used when K is calculated from Cin, and the plasma creatinine concentration is measured in well defined conditions of hydration.
Resumo:
Woven monofilament, multifilament, and spun yarn filter media have long been the standard media in liquid filtration equipment. While the energy for a solid-liquid separation process is determined by the engineering work, it is the interface between the slurry and the equipment - the filter media - that greatly affects the performance characteristics of the unit operation. Those skilled in the art are well aware that a poorly designed filter medium may endanger the whole operation, whereas well-performing filter media can make the operation smooth and economical. As the mineral and pulp producers seek to produce ever finer and more refined fractions of their products, it is becoming increasingly important to be able to dewater slurries with average particle sizes around 1 ¿m using conventional, high-capacity filtration equipment. Furthermore, the surface properties of the media must not allow sticky and adhesive particles to adhere to the media. The aim of this thesis was to test how the dirt-repellency, electrical resistance and highpressure filtration performance of selected woven filter media can be improved by modifying the fabric or yarn with coating, chemical treatment and calendering. The results achieved by chemical surface treatments clearly show that the woven media surface properties can be modified to achieve lower electrical resistance and improved dirt-repellency. The main challenge with the chemical treatments is the abrasion resistance and, while the experimental results indicate that the treatment is sufficiently permanent to resist standard weathering conditions, they may still prove to be inadequately strong in terms of actual use.From the pressure filtration studies in this work, it seems obvious that the conventional woven multifilament fabrics still perform surprisingly well against the coated media in terms of filtrate clarity and cake build-up. Especially in cases where the feed slurry concentration was low and the pressures moderate, the conventional media seemed to outperform the coated media. In the cases where thefeed slurry concentration was high, the tightly woven media performed well against the monofilament reference fabrics, but seemed to do worse than some of the coated media. This result is somewhat surprising in that the high initial specific resistance of the coated media would suggest that the media will blind more easily than the plain woven media. The results indicate, however, that it is actually the woven media that gradually clogs during the coarse of filtration. In conclusion, it seems obvious that there is a pressure limit above which the woven media looses its capacity to keep the solid particles from penetrating the structure. This finding suggests that for extreme pressures the only foreseeable solution is the coated fabrics supported by a strong enough woven fabric to hold thestructure together. Having said that, the high pressure filtration process seems to follow somewhat different laws than the more conventional processes. Based on the results, it may well be that the role of the cloth is most of all to support the cake, and the main performance-determining factor is a long life time. Measuring the pore size distribution with a commercially available porometer gives a fairly accurate picture of the pore size distribution of a fabric, but failsto give insight into which of the pore sizes is the most important in determining the flow through the fabric. Historically air, and sometimes water, permeability measures have been the standard in evaluating media filtration performance including particle retention. Permeability, however, is a function of a multitudeof variables and does not directly allow the estimation of the effective pore size. In this study a new method for estimating the effective pore size and open pore area in a densely woven multifilament fabric was developed. The method combines a simplified equation of the electrical resistance of fabric with the Hagen-Poiseuille flow equation to estimate the effective pore size of a fabric and the total open area of pores. The results are validated by comparison to the measured values of the largest pore size (Bubble point) and the average pore size. The results show good correlation with measured values. However, the measured and estimated values tend to diverge in high weft density fabrics. This phenomenon is thought to be a result of a more tortuous flow path of denser fabrics, and could most probably be cured by using another value for the tortuosity factor.
Resumo:
In this thesis the membrane filtration equipment for plate type ceramic membranes was developed based on filtration results achieved with different kinds of wastewaters. The experiments were mainly made with pulp and board mill wastewaters, but some experiments were also made with a bore well water and a stone cutting mine wastewater. The ceramicmembranes used were alpha-alumina membranes with a pore size of 100 nm. Some ofthe membranes were coated with a gamma-alumina layer to reduce the membrane pore size to 10 nm, and some of them were modified with different metal oxides in order to change the surface properties of the membranes. The effects of operationparameters, such as cross-flow velocity, filtration pressure and backflushing on filtration performance were studied. The measured parameters were the permeateflux, the quality of the permeate, as well as the fouling tendency of the membrane. A dynamic membrane or a cake layer forming on top of the membrane was observed to decrease the flux and increase separa-tion of certain substances, especially at low cross-flow velocities. When the cross-flow velocities were increased the membrane properties became more important. Backflushing could also be used to decrease the thickness of the cake layer and thus it improved the permeate flux. However, backflushing can lead to a reduction of retentions in cases where the cake layer is improving them. The wastewater quality was important for the thickness of the dynamic membrane and the membrane pore size influenced the permeate flux. In general, the optimization of operation conditions is very important for the successful operation of a membrane filtration system. The filtration equipment with a reasonable range of operational conditions is necessary, especiallywhen different kinds of wastewaters are treated. This should be taken into account already in the development stage of a filtration equipment.
Resumo:
Streaming potential measurements for the surface charge characterisation of different filter media types and materials were used. The equipment was developed further so that measurements could be taken along the surfaces, and so that tubular membranes could also be measured. The streaming potential proved to be a very useful tool in the charge analysis of both clean and fouled filter media. Adsorption and fouling could be studied, as could flux, as functions of time. A module to determine the membrane potential was also constructed. The results collected from the experiments conducted with these devices were used in the study of the theory of streaming potential as an electrokinetic phenomenon. Several correction factors, which are derived to take into account the surface conductance and the electrokinetic flow in very narrow capillaries, were tested in practice. The surface materials were studied using FTIR and the results compared with those from the streaming potentials. FTIR analysis was also found to be a useful tool in the characterisation of filters, as well as in the fouling studies. Upon examination of the recorded spectra from different depths in a sample it was possible to determine the adsorption sites. The influence of an external electric field on the cross flow microflltration of a binary protein system was investigated using a membrane electroflltration apparatus. The results showed that a significant improvement could be achieved in membrane filtration by using the measured electrochemical properties to help adjust the process conditions.
Resumo:
Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions
Resumo:
In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.
Resumo:
Enzymatic hydrolysis of lignocellulosic polymers is likely to become one of the key technologies enabling industrial production of liquid biofuels and chemicals from lignocellulosic biomass. Certain types of enzymes are able to hydrolyze cellulose and hemicellulose polymers to shorter units and finally to sugar monomers. These monomeric sugars are environmentally acceptable carbon sources for the production of liquid biofuels, such as bioethanol, and other chemicals, such as organic acids. Liquid biofuels in particular have been shown to contribute to the reduction of net emissions of greenhouse gases. The solid residue of enzymatic hydrolysis is composed mainly of lignin and partially degraded fibers, while the liquid phase contains the produced sugars. It is usually necessary to separate these two phases at some point after the hydrolysis stage. Pressure filtration is an efficient technique for this separation. Solid-liquid separation of biomass suspensions is difficult, because biomass solids are able to retain high amounts of water, which cannot be readily liberated by mechanical separation techniques. Most importantly, the filter cakes formed from biomaterials are compressible, which ultimately means that the separation may not be much improved by increasing the filtration pressure. The use of filter aids can therefore facilitate the filtration significantly. On the other hand, the upstream process conditions have a major influence on the filtration process. This thesis investigates how enzymatic hydrolysis and related process conditions affect the filtration properties of a cardboard suspension. The experimental work consists of pressure filtration and characterization of hydrolysates. The study provides novel information about both issues, as the relationship between enzymatic hydrolysis conditions and subsequent filtration properties has so far not been considered in academic studies. The results of the work reveal that the final degree of hydrolysis is an important factor in the filtration stage. High hydrolysis yield generally increases the average specific cake resistance. Mixing during the hydrolysis stage resulted in undefined changes in the physical properties of the solid residue, causing a high filtration resistance when the mixing intensity was high. Theoretical processing of the mixing data led to an interesting observation: the average specific cake resistance was observed to be linearly proportional to the mixer shear stress. Another finding worth attention is that the size distributions of the solids did not change very dramatically during enzymatic hydrolysis. There was an observable size reduction during the first couple of hours, but after that the size reduction was minimal. Similarly, the size distribution of the suspended solids remained almost constant when the hydrolyzed suspension was subjected to intensive mixing. It was also found that the average specific cake resistance was successfully reduced by the use of filter aids. This reduction depended on the method of how the filter aids were applied. In order to obtain high filtration capacity, it is recommended to use the body feed mode, i.e. to mix the filter aid with the slurry prior to filtration. Regarding the quality of the filtrate, precoat filtration was observed to produce a clear filtrate with negligible suspended solids content, while the body feed filtrates were turbid, irrespective of which type of filter aid was used.