933 resultados para feedforward path


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a wideband low-distortion sigmadelta analog-to-digital converter (ADC) for Wireless Local Area Network (WLAN) standard. The proposed converter makes use of low-distortion swing suppression SDM architecture which is highly suitable for low oversampling ratios to attain high linearity over a wide bandwidth. The modulator employs a 2-2 cascaded sigma-delta modulator with feedforward path with a single-bit quantizer in the first stage and 4-bit in the second stage. The modulator is designed in TSMC 0.18um CMOS technology and operates at 1.8V supply voltage. Simulation results show that, a peak SNDR of 57dB and a spurious free dynamic range (SFDR) of 66dB is obtained for a 10MHz signal bandwidth, and an oversampling ratio of 8.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The appearance of radix-$2^{2}$ was a milestone in the design of pipelined FFT hardware architectures. Later, radix-$2^{2}$ was extended to radix-$2^{k}$ . However, radix-$2^{k}$ was only proposed for single-path delay feedback (SDF) architectures, but not for feedforward ones, also called multi-path delay commutator (MDC). This paper presents the radix-$2^{k}$ feedforward (MDC) FFT architectures. In feedforward architectures radix-$2^{k}$ can be used for any number of parallel samples which is a power of two. Furthermore, both decimation in frequency (DIF) and decimation in time (DIT) decompositions can be used. In addition to this, the designs can achieve very high throughputs, which makes them suitable for the most demanding applications. Indeed, the proposed radix-$2^{k}$ feedforward architectures require fewer hardware resources than parallel feedback ones, also called multi-path delay feedback (MDF), when several samples in parallel must be processed. As a result, the proposed radix-$2^{k}$ feedforward architectures not only offer an attractive solution for current applications, but also open up a new research line on feedforward structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate the control mechanisms used in adapting to position-dependent forces, subjects performed 150 horizontal reaching movements over 25 cm in the presence of a position-dependent parabolic force field (PF). The PF acted only over the first 10 cm of the movement. On every fifth trial, a virtual mechanical guide (double wall) constrained subjects to move along a straight-line path between the start and target positions. Its purpose was to register lateral force to track formation of an internal model of the force field, and to look for evidence of possible alternative adaptive strategies. The force field produced a force to the right, which initially caused subjects to deviate in that direction. They reacted by producing deviations to the left, into the force field, as early as the second trial. Further adaptation resulted in rapid exponential reduction of kinematic error in the latter portion of the movement, where the greatest perturbation to the handpath was initially observed, whereas there was little modification of the handpath in the region where the PF was active. Significant force directed to counteract the PF was measured on the first guided trial, and was modified during the first half of the learning set. The total force impulse in the region of the PF increased throughout the learning trials, but it always remained less than that produced by the PF. The force profile did not resemble a mirror image of the PF in that it tended to be more trapezoidal than parabolic in shape. As in previous studies of force-field adaptation, we found that changes in muscle activation involved a general increase in the activity of all muscles, which increased arm stiffness, and selectively-greater increases in the activation of muscles which counteracted the PF. With training, activation was exponentially reduced, albeit more slowly than kinematic error. Progressive changes in kinematics and EMG occurred predominantly in the region of the workspace beyond the force field. We suggest that constraints on muscle mechanics limit the ability of the central nervous system to employ an inverse dynamics model to nullify impulse-like forces by generating mirror-image forces. Consequently, subjects adopted a strategy of slightly overcompensating for the first half of the force field, then allowing the force field to push them in the opposite direction. Muscle activity patterns in the region beyond the boundary of the force field were subsequently adjusted because of the relatively-slow response of the second-order mechanics of muscle impedance to the force impulse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast weight has great economic importance in poultry industry, and may be associated with other variables. This work aimed to estimate phenotypic correlations between performance (live body weight at 7 and 28 days, and at slaughter, and depth of the breast muscle measured by ultrasonography), carcass (eviscerated body weight and leg weight) and body composition (heart, liver and abdominal fat weight) traits in a broiler line, and quantify the direct and indirect influence of these traits on breast weight. Path analysis was used by expanding the matrix of partial correlation in coefficients which give the direct influence of one trait on another, regardless the effect of the other traits. The simultaneous maintenance of live body weight at slaughter and eviscerated body weight in the matrix of correlations might be harmful for statistical analysis involving systems of normal equations, like path analysis, due to the observed multicollinearity. The live body weight at slaughter and the depth of the breast muscle as measured by ultrasonography directly affected breast weight and were identified as the most responsible factors for the magnitude of the correlation coefficients obtained between the studied traits and breast weight. Individual pre-selection for these traits could favor an increased breast weight in the future reproducer candidates of this line if the broilers' environmental conditions and housing are maintained, since the live body weight at slaughter and the depth of breast muscle measured by ultrasonography were directly related to breast weight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the current study was to understand how visual information about an ongoing change in obstacle size is used during obstacle avoidance for both lead and trail limbs. Participants were required to walk in a dark room and to step over an obstacle edged with a special tape visible in the dark. The obstacle's dimensions were manipulated one step before obstacle clearance by increasing or decreasing its size. Two increasing and two decreasing obstacle conditions were combined with seven control static conditions. Results showed that information about the obstacle's size was acquired and used to modulate trail limb trajectory, but had no effect on lead limb trajectory. The adaptive step was influenced by the time available to acquire and process visual information. In conclusion, visual information about obstacle size acquired during lead limb crossing was used in a feedforward manner to modulate trail limb trajectory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have measured the azimuthal anisotropy of pi(0) production for 1 < p(T) < 18 GeV/c for Au + Au collisions at root s(NN) = 200 GeV. The observed anisotropy shows a gradual decrease for 3 less than or similar to p(T) less than or similar to 7-10 GeV/c, but remains positive beyond 10 GeV/c. The magnitude of this anisotropy is underpredicted, up to at least similar to 10 GeV/c, by current perturbative QCD (PQCD) energy-loss model calculations. An estimate of the increase in anisotropy expected from initial-geometry modification due to gluon saturation effects and fluctuations is insufficient to account for this discrepancy. Calculations that implement a path-length dependence steeper than what is implied by current PQCD energy-loss models show reasonable agreement with the data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This investigation presents a comprehensive characterization of magnetic and transport properties of an interesting superconducting wire, Nb-Ti -Ta, obtained through the solid-state diffusion between Nb-12 at.% Ta alloy and pure Ti. The physical properties obtained from magnetic and transport measurements related to the microstructure unambiguously confirmed a previous proposition that the superconducting currents flow in the center of the diffusion layer, which has a steep composition variation. The determination of the critical field also confirmed that the flux line core size is not constant, and in addition it was possible to determine that, in the center of the layer, the flux line core is smaller than at the borders. A possible core shape design is proposed. Among the wires studied, the one that presented the best critical current density was achieved for a diffusion layer with a composition of about Nb-32% Ti-10% Ta, obtained with a heat treatment at 700 degrees C during 120 h, in agreement with previous studies. It was determined that this wire has the higher upper critical field, indicating that the optimization of the superconducting behavior is related to an intrinsic property of the ternary alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulated annealing (SA) is an optimization technique that can process cost functions with degrees of nonlinearities, discontinuities and stochasticity. It can process arbitrary boundary conditions and constraints imposed on these cost functions. The SA technique is applied to the problem of robot path planning. Three situations are considered here: the path is represented as a polyline; as a Bezier curve; and as a spline interpolated curve. In the proposed SA algorithm, the sensitivity of each continuous parameter is evaluated at each iteration increasing the number of accepted solutions. The sensitivity of each parameter is associated to its probability distribution in the definition of the next candidate. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Causal inference methods - mainly path analysis and structural equation modeling - offer plant physiologists information about cause-and-effect relationships among plant traits. Recently, an unusual approach to causal inference through stepwise variable selection has been proposed and used in various works on plant physiology. The approach should not be considered correct from a biological point of view. Here, it is explained why stepwise variable selection should not be used for causal inference, and shown what strange conclusions can be drawn based upon the former analysis when one aims to interpret cause-and-effect relationships among plant traits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a new approach for designing planar gradient coils is outlined for the use in an existing MRI apparatus. A technique that allows for gradient field corrections inside the diameter-sensitive volume is deliberated. These corrections are brought about by making changes to the wire paths that constitute the coil windings, and hence, is called the path correction method. The existing well-known target held method is used to gauge the performance of a typical gradient coil. The gradient coil design methodology is demonstrated for planar openable gradient coils that can be inserted into an existing MRI apparatus. The path corrected gradient coil is compared to the coil obtained using the target field method. It is shown that using a wire path correction with optimized variables, winding patterns that can deliver high magnetic gradient field strengths and large imaging regions can be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the structure of the spine is inherently unstable, muscle activation is essential for the maintenance of trunk posture and intervertebral control when the limbs are moved. To investigate how the central nervous system deals with this situation the temporal components of the response of the muscles of the trunk were evaluated during rapid limb movement performed in response to a visual stimulus. Fine-wire electromyography (EMG) electrodes were inserted into transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) of 15 subjects under the guidance of real-time ultrasound imaging. Surface electrodes were placed over rectus abdominis (RA), lumbar multifidus (MF) and the three parts of deltoid. In a standing position, ten repetitions of shoulder flexion, abduction and extension were performed by the subjects as fast as possible in response to a visual stimulus. The onset of TrA EMG occurred in advance of deltoid irrespective of the movement direction. The time to onset of EMC activity of OI, OE, RA and MF varied with the movement direction, being activated earliest when the prime action of the muscle opposed the reactive forces associated with the specific limb movement. It is postulated that the non-direction-specific contraction of TrA may be related to the control of trunk. stability independent of the requirement for direction-specific control of the centre of gravity in relation to the base of support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in trunk muscle recruitment have been identified in people with low-back pain (LBP). These differences may be due to changes in the planning of the motor response or due to delayed transmission of the descending motor command in the nervous system. These two possibilities were investigated by comparison of the effect of task complexity on the feedforward postural response of the trunk muscles associated with rapid arm movement in people with and without LBP. Task complexity was increased by variation of the expectation for a command to either abduct or flex the upper limb. The onsets of electromyographic activity (EMG) of the abdominal and deltoid muscles were measured. In control subjects, while the reaction time of deltoid and the superficial abdominal muscles increased with task complexity, the reaction time of transversus abdominis (TrA) was constant. However, in subjects with LBP, the reaction time of TrA increased along with the other muscles as task complexity was increased. While inhibition of the descending motor command cannot be excluded, it is more likely that the change in recruitment M of TrA represents a more complex change in organisation of the postural response.