937 resultados para false positive result


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The definitive diagnosis of visceral. leishmaniasis (VL) requires invasive procedures with demonstration of amastigotes in tissue or promastigotes in culture. Unfortunately, these approaches require laboratory materials not available in poor countries where the disease is endemic. The correct diagnosis of VL is important, and made more difficult by the fact that several common tropical diseases such as malaria, disseminated tuberculosis, and enteric fever share the same clinical presentation. Serological tests have been developed to replace parasitological diagnosis in the field. A commercially available K39-based strip test for VL has been developed for this purpose. The endemic area of leishmaniasis in Brazil overlaps the endemic area of Chagas disease, a disease that can cause false-positive serological test results. The aim of this study was to evaluate the incidence of false-positive exams using a rapid test for VL in patients with Chagas disease. Methods: A rapid test based on the recombinant K39 antigen of Leishmania was used in: (1) 30 patients with confirmed Chagas disease, (2) 30 patients with a serological diagnosis of Chagas disease by ELISA, indirect immunofluorescence, indirect hemagglutination, and chemiluminescence, (3) 30 healthy patients from a non-endemic area as the control group, (4) 30 patients with confirmed VL, and (5) 20 patients with proved cutaneous leishmaniasis. Results: The sensitivity and specificity of the rapid strip test were 100% when compared with healthy volunteers and those with confirmed Chagas disease. One false-positive result occurred in the group with Chagas disease diagnosed by serological tests (specificity of 96%). Conclusion: The rapid test based on recombinant K39 is a useful diagnostic assay, and a false-positive result rarely occurs in patients with a serological diagnosis of Chagas disease. (C) 2008 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a short-term longitudinal design, and consistent with a stress and coping perspective, this study examined the main and stress-buffering effects of social support and coping on emotional well-being following a 'false positive' breast cancer screening result. Immediately prior to obtaining results of follow-up assessment, 178 women completed measures of emotional well-being, stress appraisal, coping strategies and social support. Six weeks later, 85 women found to be cancer free completed a measure of well-being. Hierarchical regression analyses were used to examine the effects of social support and coping on well-being after controlling for initial well-being and stress appraisal. Consistent with predictions, avoidant coping was associated with higher levels of emotional well-being and social support was found to have a stress buffering effect on well-being. Active-cognitive coping strategies had a stress-buffering effect on well-being. Findings suggest that social support and coping do influence emotional well-being following recall for follow-up assessment of a 'false positive' breast cancer screening result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to assess the potential risk of anti-HBc-positive blood donors for post-transfusional hepatitis and to investigate whether other HBV serological markers are capable of identifying the presence of the virus, 1000 first-time blood donors were enrolled between June and July 1997. These donors were screened using routine Brazilian blood center tests (HIV 1 and 2, HTLV 1 and 2, Chagas disease, Syphilis, HCV, HBsAg, anti-HBc and ALT ). The 120 (12%) found to be anti-HBc-positive underwent further tests: HBe, anti-HBe, anti-HBs and HBV-DNA by PCR. Ten cases were HBsAg positive and all were HBV-DNA positive by PCR. Three HBsAg-negative donors were HBV-DNA-positive. Two HBV-DNA-positive donors were also anti-HBs-positive. All the HBV-positive donors had at least one HBV marker other than anti-HBc. Anti-HBc is an important cause of blood rejection. Testing for HBsAg alone is not fully protective and anti-HBc remains necessary as a screening test. The presence of anti-HBs is not always indicative of absence of the virus. The addition of other HBV serological markers could represent an alternative in predicting the presence of the virus when compared with PCR. It is recommended that other studies should be carried out to confirm this finding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The unresolved issue of false-positive D-dimer results in the diagnostic workup of pulmonary embolism Pulmonary embolism (PE) remains a difficult diagnosis as it lacks specific symptoms and clinical signs. After the determination of the pretest PE probability by a validated clinical score, D-dimers (DD) is the initial blood test in the majority of patients whose probability is low or intermediate. The low specificity of DD results in a high number of false-positives that then require thoracic angio-CT. A new clinical decision rule, called the Pulmonary Embolism Rule-out criteria (PERC), identifies patients at such low risk that PE can be safely ruled-out without a DD test. Its safety has been confirmed in US emergency departments, but retrospective European studies showed that it would lead to 5-7% of undiagnosed PE. Alternative strategies are needed to reduce the proportion of false-positive DD results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32?33 (97%) cancerous biopsies and rejected 17?20 (85%) noncancerous lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32/33 (97%) cancerous biopsies and rejected 17/20 (85%) noncancerous lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of a hearing screening program, particularly focusing on hit and false positive rates in the NICU and WBN at a top-rated birthing hospital in Saint Louis, MO. Additionally, the study examined how these rates may be influenced by risk factors for hearing loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have indicated that research practices in psychology may be susceptible to factors that increase false-positive rates, raising concerns about the possible prevalence of false-positive findings. The present article discusses several practices that may run counter to the inflation of false-positive rates. Taking these practices into account would lead to a more balanced view on the false-positive issue. Specifically, we argue that an inflation of false-positive rates would diminish, sometimes to a substantial degree, when researchers (a) have explicit a priori theoretical hypotheses, (b) include multiple replication studies in a single paper, and (c) collect additional data based on observed results. We report findings from simulation studies and statistical evidence that support these arguments. Being aware of these preventive factors allows researchers not to overestimate the pervasiveness of false-positives in psychology and to gauge the susceptibility of a paper to possible false-positives in practical and fair ways.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET) was a prospective, randomized, double-blinded, placebo-controlled, phase II trial of alteplase between 3 and 6 hours after stroke onset. The primary outcome of infarct growth attenuation on MRI with alteplase in mismatch patients was negative when mismatch volumes were assessed volumetrically, without coregistration, which underestimates mismatch volumes. We hypothesized that assessing the extent of mismatch by coregistration of perfusion and diffusion MRI maps may more accurately allow the effects of alteplase vs placebo to be evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The association of simian virus 40 (SV40) with malignant pleural mesothelioma is currently under debate. In some malignancies of viral aetiology, viral DNA can be detected in the patients' serum or plasma. To characterize the prevalence of SV40 in Swiss mesothelioma patients, we optimized a real-time PCR for quantitative detection of SV40 DNA in plasma, and used a monoclonal antibody for immunohistochemical detection of SV40 in mesothelioma tissue microarrays. Real-time PCR was linear over five orders of magnitude, and sensitive to a single gene copy. Repeat PCR determinations showed excellent reproducibility. However, SV40 status varied for independent DNA isolates of single samples. We noted that SV40 detection rates by PCR were drastically reduced by the implementation of strict room compartmentalization and decontamination procedures. Therefore, we systematically addressed common sources of contamination and found no cross-reactivity with DNA of other polyomaviruses. Contamination during PCR was rare and plasmid contamination was infrequent. SV40 DNA was reproducibly detected in only 4 of 78 (5.1%) plasma samples. SV40 DNA levels were low and not consistently observed in paired plasma and tumour samples from the same patient. Immunohistochemical analysis revealed a weak but reproducible SV40 staining in 16 of 341 (4.7%) mesotheliomas. Our data support the occurrence of non-reproducible SV40 PCR amplifications and underscore the importance of proper sample handling and analysis. SV40 DNA and protein were found at low prevalence (5%) in plasma and tumour tissue, respectively. This suggests that SV40 does not appear to play a major role in the development of mesothelioma.