147 resultados para façade
Resumo:
The study of new abundant coral crops and a systematic revision of the historic collections allow us to extend significantly the data about the Upper Oligocene and Miocene Scleractinia of the French atlantic basins. The SW and W-NW France faunas have been considered, and complete lists of the different defined taxa are presented. The generallines of the evolution of this group are specified, and linked to the paleoclimatic and paleobiogeographic changes.
Resumo:
The study of new abundant coral crops and a systematic revision of the historie collections allow us to extend significantly the data about the Upper Oligocene and Miocene Scleractinia of the French atlantic basins. The SW and W-NW France faunas have been considered, and complete lists of the different defined taxa are presented. The general lines of the evolution of this group are specified, and linked to the paleoclimatic and paleobiogeographic changes.
Resumo:
Nowadays natural ventilation has gained prominence because its correct use can reduce energy consumption for cooling systems and improve thermal comfort among users. In this paper, we report on the modelling initiative, based on the wind tunnel tests that were carried out for the determination of the influence of natural ventilation in buildings. Indeed, the renewal of air in a closed environment without using an air conditioning system with mechanical elements can lead to energy savings and, in addition, provide air quality.The wind tunnel tests were carried out by varying the positioning of six ventilation modules in the façade system configuration. The modules were positioned below the window-sill (ventilated window-sill) as well as separately above and below the façade. The wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. The results supported the positioning of the six ventilation modules below the window-sill, forming a â ventilated window-sillâ as the most effective natural ventilation solution.
Resumo:
Wind tunnel tests are a reliable tool to determine the effect of natural ventilation on buildings. This paper presents results of wind tunnel tests conducted to evaluate the influence of ventilation modules positioning on a façade system. Modules positioning was modified, resulting in different façade configurations. The tests were carried out with the use of a model, varying the position of the ventilation modules in the façade configuration. The cases tested were six ventilation modules positioned below the window-sill (ventilated window-sill), and three ventilation modules positioned above and below the façade. The façade system proposed was movable and interchangeable so that the same basic model could be used to test the possibilities for ventilation. Wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. Singleâ sided and Cross ventilation were considered for wind speed measurements. Results show the use of six ventilation modules positioned below the window-sill, forming "a ventilated window-sill" is the best solution in terms of natural ventilation.
Resumo:
This paper reports on a new façade system that uses passive solutions in the search for energy efficiency. The differentials are the versatility and flexibility of the modules, which are important advantages of the system. The thermal performance of Trombe walls and glazings and the daylighting performance of glazing were the key aspects analyzed in the results. Computational simulations were accomplished for the thermal performance of different arrangements of the modules with DesignBuilder software. The glazing daylighting performance was studied by means of Ecotect and Desktop Radiance programs and compared with the transmittance curves of glazings. Occupancy profile and internal gains were fixed according to the Portuguese reality for both studies. The main characteristics considered in this research were the use of two double glazings, four different climates in Portugal and one and two Trombe walls in the façade. The results show an important reduction in the energy consumption with the use of Trombe walls and double self-cleaning glazing in the façade, which also presented better daylighting performance.
Resumo:
Les auteurs décrivent la femelle de Lutzomyia zeledoni Young et Murillo, 1984 du Groupe Vespertilionis Theodor, 1965. Cette espèce a été capturée en milieu péridomestique en compagnie de Lutzomyia longpalpis Lutz et Neiva, 1912 répertorié pour la première fois du Nicaragua. Il est mis l'accent sur l'importance épidémiologique de cette dernière espèce récoltée en abondance dans plusieurs stations de la façade pacifique.
Resumo:
Référence bibliographique : Rol, 55103
Resumo:
Référence bibliographique : Rol, 55106
Resumo:
Référence bibliographique : Rol, 55111
Resumo:
Référence bibliographique : Rol, 54798
Resumo:
Référence bibliographique : Rol, 54797
Resumo:
Référence bibliographique : Rol, 54796
Resumo:
Référence bibliographique : Rol, 57128