992 resultados para eyelid opening time


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the dynamics of ocular eyelid movements in newborn infants and preschool-age children.Methods: Fifty newborn infants and 200 preschool children aged 4-6 years were examined. Images of each child, with his or her eyes in the primary eye position looking at an object placed at the child's height, were recorded with a digital videocamera for 3 mins. Complete and incomplete blink rates, opening, closing and complete blink times were calculated.Results: Newborn infants presented a lower number of incomplete movements than preschool children. The complete blink rate was lower in newborn infants (6.2 blinks/min) than in preschool children (8.0 blinks/minute). Eyelid closing, opening and compete blink times were longer in newborn infants than in preschool children at all observation times.Conclusions: Newborn infants had a different pattern of eyelid movement compared with preschool children. Specific characteristics that are found in this group of children particularly, such as immaturity of the neural system and more resistant tear film, may explain these findings in part.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The time response of optical switching properties of Sb thin films under focused laser pulses is investigated. The results show that the response course can be divided into onset, opening, and closing stages. Formulas for their lengths are given. The onset and opening times decrease with increasing pumping light power density. The closing time is about 150 ns. For optical memory, if the power density of the readout and recording lasers changes from 5 x 10(9) to 15 x 10(9) W/m(2), the onset time changes from 2.5 to 0.30 mus, and the opening time is on the nanosecond scale. (C) 2003 Society of Photo-Optical Instrumentation Engineers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Estabelecer o padrão de normalidade do ritmo de piscar em crianças normais em idade pré-escolar. MÉTODOS: Avaliaram-se 200 crianças de 4 a 6 anos, saudáveis, usando tomada de imagens digitais, nos planos frontal e lateral, em estado de vigília, em posição primária do olhar, estando o objeto de observação localizado na altura da pupila. Para a tomada das imagens foi utilizada uma filmadora Sony Lithium, sendo as mesmas gravadas em fitas 8 mm, transferidas para um computador MacIntosh G4 e processadas pelo programa iMovie, estudando-se: o tempo de abertura e o tempo de fechamento palpebral, o tempo de piscar completo e o ritmo de movimentos palpebrais por minuto, durante 3 minutos. Os resultados foram avaliados por estatística descritiva e gráfico de linhas. RESULTADOS: O piscar completo foi mais freqüente que o incompleto. O ritmo do piscar completo aumenta com o aumento da idade. Para o piscar incompleto, os valores foram semelhantes em todas as idades avaliadas. O tempo de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em meninos e meninas. O tempo de fechamento foi mais lento que o tempo de abertura palpebral. CONCLUSÕES: O ritmo de piscar completo aumenta com a idade. Os tempos de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em ambos os sexos, em todas as idades estudadas, sendo o fechamento mais lento que a abertura palpebral.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Spontaneous eye blink activity in the primary eye position and its relationship to age and gender were assessed using digital image processing techniques to quantify blink opening and closing time. Methods: One hundred-and-eighty healthy volunteers (90 males and 90 females), divided into the age groups 0-3, 4-12, 13-20, 21-40, 41-60 and ≥60 years old, were evaluated prospectively. They were videotaped digitally in a standard setting and the images were transferred to a personal computer (Macintosh 400) and processed with the iMovie software. Blink opening and closing time were measured at 30 frames/second. The data were then subjected to statistical analysis. Results: The closing time was significantly longer than the opening time for all ages and both genders. Elderly individuals (≥41 years old) and women had significantly longer closing times. Conclusion: Image processing techniques made possible the observation of differences in spontaneous eye blink opening and closing time in relation to age and gender. Copyright © 2005 Taylor & Francis LLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O projeto foi realizado na Toyota (divisão fabril de Ovar), no ano letivo 2014/2015, teve por base um estágio extracurricular que foi realizado para que desta forma tomasse contacto com uma realidade concreta e absoluta no contexto empresarial. O estágio serviu, principalmente, como uma experiência na compreensão do funcionamento de uma indústria de automóveis. Este projeto desenvolve-se no âmbito do 2ºano do Mestrado de Logística e apresenta os contributos desenvolvidos no departamento de logística para a reorganização da mesma para a produção de um novo modelo automóvel. Atualmente, a Toyota, para os modelos de automóveis que produz, recebe os componentes em CKD (Completed Knocked Down) provenientes do Japão em lotes de cinco unidades. Estes lotes são armazenados no armazém, de onde só saem quando for dada ordem para serem produzidos. Cada lote tem várias caixas, que são colocadas à vez numa zona comum de abertura. São retidos os componentes das caixas CKD e colocados nos transportadores próprios dos postos correspondentes (supermercado de linha). Isto significa que sempre que é solicitado uma viatura de um determinado lote, são obrigados a produzir as cinco unidades. Isto significa que as restantes unidades do lote terão que ficar em parque aberto a aguardar venda futura, para além de ter um stock desnecessário, estas unidades ficam vulneráveis e sofrem desgaste, pois estão expostas à intempérie, causando graves problemas de qualidade e respetivos custos associados. Recentemente, foi decidida a produção do modelo Land Cruiser 70 na unidade industrial de Ovar, Portugal, o que obrigou a uma reorganização da produção e processos logísticos para a sua produção. Os objetivos que a empresa pretende com a entrada de um novo projeto Land Cruiser 70, são os seguintes: Alterar o sistema de abastecimento, implementando o abastecimento unitário em toda a fábrica para o novo modelo, garantindo o “one by one production”; Definir o funcionamento do processo logístico desde a chegada dos componentes até ficarem disponíveis no supermercado de linha. Para isso será necessário dimensionar armazém e zona de abertura, definir layouts e quantidade de stocks, bem como definir sistemas de comunicação entre abertura e supermercado; Verificar as peças que vão fazer parte do chassi por posto e contabilizar os dolly´s1 necessários; Fazer o layout de abastecimento da linha do chassi; Calcular o tempo de abertura, de abastecimento e de picking do chassi e de triming. Este projeto tem em conta a política de melhoria contínua de forma a conseguir satisfazer o cliente (ser eficaz) utilizando cada vez menos recursos quer físicos quer humanos (ser eficiente, detetar e eliminar os desperdícios). O presente projeto foi inserido na equipa de melhoria contínua da logística, maioritariamente no chassi. Em termos globais, os objetivos propostos neste estágio foram atingidos com êxito.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les neurones des couches superficielles du collicule supérieur et du cortex visuel primaire du rat adulte sont sensibles à de basses fréquences spatiales de haut contraste défilant à des vitesses élevées. Entre les jours post-nataux 27-30 et l’âge adulte, les fréquences temporelles optimales des neurones du cortex visuel primaire augmentent, tandis que leurs seuils de contraste diminuent. Cependant, les fréquences spatiales optimales, les valeurs de résolution spatiale et les bandes passantes spatiales de ces neurones sont, dès l’ouverture des paupières, similaires à celles observées chez le rat adulte. Ces profils de réponse neuronale suggèrent que les projections rétino-colliculaires et rétino-géniculo-corticales sont essentiellement issues de neurones ganglionnaires rétinofuges magnocellulaires et koniocellulaires. Les neurones du cortex visuel primaire du rat ayant subi des convulsions hyperthermiques présentent, dès l’ouverture des paupières, de basses fréquences spatiales optimales, de larges bandes passantes directionnelles et temporelles ainsi que des seuils de contraste élevés par rapport aux neurones du rat normal. À l’âge adulte, de basses fréquences temporelles optimales et de larges bandes passantes spatiales sont également observées chez le rat ayant subi des convulsions hyperthermiques. L’altération des profils de réponse des neurones du cortex visuel primaire du rat ayant subi de convulsions hyperthermiques suggère un déséquilibre entre les mécanismes neuronaux excitateurs et inhibiteurs de cette aire corticale. Ces résultats suggèrent également qu’un épisode unique de convulsions fébriles infantiles suffit à altérer le développement des propriétés spatio-temporelles des champs récepteurs des neurones du cortex visuel primaire.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose – To evaluate the control strategy for a hybrid natural ventilation wind catchers and air-conditioning system and to assess the contribution of wind catchers to indoor air environments and energy savings if any. Design/methodology/approach – Most of the modeling techniques for assessing wind catchers performance are theoretical. Post-occupancy evaluation studies of buildings will provide an insight into the operation of these building components and help to inform facilities managers. A case study for POE was presented in this paper. Findings – The monitoring of the summer and winter month operations showed that the indoor air quality parameters were kept within the design target range. The design control strategy failed to record data regarding the operation, opening time and position of wind catchers system. Though the implemented control strategy was working effectively in monitoring the operation of mechanical ventilation systems, i.e. AHU, did not integrate the wind catchers with the mechanical ventilation system. Research limitations/implications – Owing to short-falls in the control strategy implemented in this project, it was found difficult to quantify and verify the contribution of the wind catchers to the internal conditions and, hence, energy savings. Practical implications – Controlling the operation of the wind catchers via the AHU will lead to isolation of the wind catchers in the event of malfunctioning of the AHU. Wind catchers will contribute to the ventilation of space, particularly in the summer months. Originality/value – This paper demonstrates the value of POE as indispensable tool for FM professionals. It further provides insight into the application of natural ventilation systems in building for healthier indoor environments at lower energy cost. The design of the control strategy for natural ventilation and air-conditioning should be considered at the design stage involving the FM personnel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Backgrounds and Objectives: Both continuous venous anesthesia with propofol and inhalational anesthesia with sevoflurane propitiate fast arousal with few side effects. The aim of this study was to compare the arousal and post anesthestic recovery times in patients submitted to these two agents. Methods: Forty three patient aged 18 to 50 years, physical status I or II, submitted to gynecological laparoscopy were distributed in two groups: G1 - propofol in continuous infusion of 115 μg.kg -1.min -1 and G2 sevoflurane. All the patients were pre-medicated with 7.5 mg midazolam, sufentanil 0.5 μg.kg -1, propofol 2 mg.kg -1, atracurium 0.5 mg.kg -1, N 2O in 50% of oxygen in a no-rebreathing system. The depth of the anesthesia and arousal time were assessed by the Bispectral index (BIS). The time between end of anesthesia and eye opening, time for command response and time for orientation were also evaluated. Results: The times recorded in minutes were: G1 - eye opening 8.2 ± 2.9, command response 8.6 ± 3.1, orientation 9.8 ± 3.4, recovery 31.6 ± 3.8; G2 - eye opening 4.5 ± 3, command response 4.9 ± 3.4, orientation 6.2 ± 3.4, recovery 66 ± 8. Except the recovery time, all the values were larger in G1. Conclusions: Both intravenous propofol or inhalational sevoflurane were considered excellent anesthetic techniques as to recovery time and recovery room discharge. Sevoflurane provided an earlier arousal with a longer recovery room stay as compared to propofol.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Progressive supranuclear palsy is a rare, degenerative brain disorder and the second most common syndrome in which the patient exhibits 'parkinsonism', that is, a variety of symptoms involving problems with movement. General symptoms include difficulties with gait and balance; the patient walking clumsily and often falling backwards. The syndrome can be difficult to diagnose and visual signs and symptoms can help to separate it from closely related movement disorders such as Parkinson's disease, multiple system atrophy, dementia with Lewy bodies and corticobasal degeneration. A combination of the presence of vertical supranuclear gaze palsy, fixation instability, lid retraction, blepharospasm and apraxia of eyelid opening and closing may be useful visual signs in the identification of progressive supranuclear palsy. As primary eye-care practitioners, optometrists should be able to identify the visual problems of patients with this disorder and be expected to work with patients and their carers to manage their visual welfare.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Differential clinical diagnosis of the parkinsonian syndromes, viz., Parkinson’s disease (PD), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB), and multiple system atrophy (MSA) can be difficult. Eye movement problems, however, are a chronic complication of many of these disorders and may be a useful aid to diagnosis. Hence, the presence in PSP of vertical supranuclear gaze palsy, fixation instability, lid retraction, blepharospasm, and apraxia of eyelid opening and closing is useful in separating PD from PSP. Moreover, atypical features of PSP include slowing of upward saccades, moderate slowing of downward saccades, the presence of a full range of voluntary vertical eye movements, a curved trajectory of oblique saccades, and absence of square-wave jerks. Downgaze palsy is probably the most useful diagnostic clinical symptom of PSP. By contrast, DLB patients are specifically impaired in both reflexive and saccadic execution and in the performance of more complex saccadic eye movement tasks. Problems in convergence in DLB are also followed by akinesia and rigidity. Abnormal ocular fixation may occur in a significant proportion of MSA patients along with excessive square-wave jerks, a mild supranuclear gaze palsy, a gaze-evoked nystagmus, a positioning down-beat nystagmus, mild-moderate saccadic hypometria, impaired smooth pursuit movements, and reduced vestibulo-ocular reflex (VOR) suppression. There may be considerable overlap between the eye movement problems characteristic of the various parkinsonian disorders, but taken together with other signs and symptoms, can be a useful aid in differential diagnosis, especially in the separation of PD and PSP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Spanish, french and portuguese versions available

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.