986 resultados para eyelid closing time


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the dynamics of ocular eyelid movements in newborn infants and preschool-age children.Methods: Fifty newborn infants and 200 preschool children aged 4-6 years were examined. Images of each child, with his or her eyes in the primary eye position looking at an object placed at the child's height, were recorded with a digital videocamera for 3 mins. Complete and incomplete blink rates, opening, closing and complete blink times were calculated.Results: Newborn infants presented a lower number of incomplete movements than preschool children. The complete blink rate was lower in newborn infants (6.2 blinks/min) than in preschool children (8.0 blinks/minute). Eyelid closing, opening and compete blink times were longer in newborn infants than in preschool children at all observation times.Conclusions: Newborn infants had a different pattern of eyelid movement compared with preschool children. Specific characteristics that are found in this group of children particularly, such as immaturity of the neural system and more resistant tear film, may explain these findings in part.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The time response of optical switching properties of Sb thin films under focused laser pulses is investigated. The results show that the response course can be divided into onset, opening, and closing stages. Formulas for their lengths are given. The onset and opening times decrease with increasing pumping light power density. The closing time is about 150 ns. For optical memory, if the power density of the readout and recording lasers changes from 5 x 10(9) to 15 x 10(9) W/m(2), the onset time changes from 2.5 to 0.30 mus, and the opening time is on the nanosecond scale. (C) 2003 Society of Photo-Optical Instrumentation Engineers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Estabelecer o padrão de normalidade do ritmo de piscar em crianças normais em idade pré-escolar. MÉTODOS: Avaliaram-se 200 crianças de 4 a 6 anos, saudáveis, usando tomada de imagens digitais, nos planos frontal e lateral, em estado de vigília, em posição primária do olhar, estando o objeto de observação localizado na altura da pupila. Para a tomada das imagens foi utilizada uma filmadora Sony Lithium, sendo as mesmas gravadas em fitas 8 mm, transferidas para um computador MacIntosh G4 e processadas pelo programa iMovie, estudando-se: o tempo de abertura e o tempo de fechamento palpebral, o tempo de piscar completo e o ritmo de movimentos palpebrais por minuto, durante 3 minutos. Os resultados foram avaliados por estatística descritiva e gráfico de linhas. RESULTADOS: O piscar completo foi mais freqüente que o incompleto. O ritmo do piscar completo aumenta com o aumento da idade. Para o piscar incompleto, os valores foram semelhantes em todas as idades avaliadas. O tempo de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em meninos e meninas. O tempo de fechamento foi mais lento que o tempo de abertura palpebral. CONCLUSÕES: O ritmo de piscar completo aumenta com a idade. Os tempos de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em ambos os sexos, em todas as idades estudadas, sendo o fechamento mais lento que a abertura palpebral.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Spontaneous eye blink activity in the primary eye position and its relationship to age and gender were assessed using digital image processing techniques to quantify blink opening and closing time. Methods: One hundred-and-eighty healthy volunteers (90 males and 90 females), divided into the age groups 0-3, 4-12, 13-20, 21-40, 41-60 and ≥60 years old, were evaluated prospectively. They were videotaped digitally in a standard setting and the images were transferred to a personal computer (Macintosh 400) and processed with the iMovie software. Blink opening and closing time were measured at 30 frames/second. The data were then subjected to statistical analysis. Results: The closing time was significantly longer than the opening time for all ages and both genders. Elderly individuals (≥41 years old) and women had significantly longer closing times. Conclusion: Image processing techniques made possible the observation of differences in spontaneous eye blink opening and closing time in relation to age and gender. Copyright © 2005 Taylor & Francis LLC.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Lapeyre-Triflo FURTIVA valve aims at combining the favorable hemodynamics of bioprosthetic heart valves with the durability of mechanical heart valves (MHVs). The pivoting region of MHVs is hemodynamically of special interest as it may be a region of high shear stresses, combined with areas of flow stagnation. Here, platelets can be activated and may form a thrombus which in the most severe case can compromise leaflet mobility. In this study we set up an experiment to replicate the pulsatile flow in the aortic root and to study the flow in the pivoting region under physiological hemodynamic conditions (CO = 4.5 L/min / CO = 3.0 L/min, f = 60 BPM). It was found that the flow velocity in the pivoting region could reach values close to that of the bulk flow during systole. At the onset of diastole the three valve leaflets closed in a very synchronous manner within an average closing time of 55 ms which is much slower than what has been measured for traditional bileaflet MHVs. Hot spots for elevated viscous shear stresses were found at the flanges of the housing and the tips of the leaflet ears. Systolic VSS was maximal during mid-systole and reached levels of up to 40 Pa.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Condition monitoring of diesel engines can prevent unpredicted engine failures and the associated consequence. This paper presents an experimental study of the signal characteristics of a 4-cylinder diesel engine under various loading conditions. Acoustic emission, vibration and in-cylinder pressure signals were employed to study the effectiveness of these techniques for condition monitoring and identifying symptoms of incipient failures. An event driven synchronous averaging technique was employed to average the quasi-periodic diesel engine signal in the time domain to eliminate or minimize the effect of engine speed and amplitude variations on the analysis of condition monitoring signal. It was shown that acoustic emission (AE) is a better technique than vibration method for condition monitor of diesel engines due to its ability to produce high quality signals (i.e., excellent signal to noise ratio) in a noisy diesel engine environment. It was found that the peak amplitude of AE RMS signals correlating to the impact-like combustion related events decreases in general due to a more stable mechanical process of the engine as the loading increases. A small shift in the exhaust valve closing time was observed as the engine load increases which indicates a prolong combustion process in the cylinder (to produce more power). On the contrary, peak amplitudes of the AE RMS attributing to fuel injection increase as the loading increases. This can be explained by the increase fuel friction caused by the increase volume flow rate during the injection. Multiple AE pulses during the combustion process were identified in the study, which were generated by the piston rocking motion and the interaction between the piston and the cylinder wall. The piston rocking motion is caused by the non-uniform pressure distribution acting on the piston head as a result of the non-linear combustion process of the engine. The rocking motion ceased when the pressure in the cylinder chamber stabilized.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dynamics of loop formation by linear polymer chains has been a topic of several theoretical and experimental studies. Formation of loops and their opening are key processes in many important biological processes. Loop formation in flexible chains has been extensively studied by many groups. However, in the more realistic case of semiflexible polymers, not much results are available. In a recent study [K. P. Santo and K. L. Sebastian, Phys. Rev. E 73, 031923 (2006)], we investigated opening dynamics of semiflexible loops in the short chain limit and presented results for opening rates as a function of the length of the chain. We presented an approximate model for a semiflexible polymer in the rod limit based on a semiclassical expansion of the bending energy of the chain. The model provided an easy way to describe the dynamics. In this paper, using this model, we investigate the reverse process, i.e., the loop formation dynamics of a semiflexible polymer chain by describing the process as a diffusion-controlled reaction. We make use of the ``closure approximation'' of Wilemski and Fixman [G. Wilemski and M. Fixman, J. Chem. Phys. 60, 878 (1974)], in which a sink function is used to represent the reaction. We perform a detailed multidimensional analysis of the problem and calculate closing times for a semiflexible chain. We show that for short chains, the loop formation time tau decreases with the contour length of the polymer. But for longer chains, it increases with length obeying a power law and so it has a minimum at an intermediate length. In terms of dimensionless variables, the closing time is found to be given by tau similar to L-n exp(const/L), where n=4.5-6. The minimum loop formation time occurs at a length L-m of about 2.2-2.4. These are, indeed, the results that are physically expected, but a multidimensional analysis leading to these results does not seem to exist in the literature so far.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Based on the Wilemski-Fixman approach G. Wilemski, M. Fixman, J. Chem. Phys. 60 (1974) 866], we show that, for a flexible chain in theta solvent, hydrodynamic interaction treated with a pre-averaging approximation makes ring closing faster if the chain is not very short. We also show that the ring closing time for a long chain with hydrodynamic interaction in theta solvent scales with the chain length (N) as N-1.5, in agreement with the previous renormalization group calculation based prediction by Freidman and O'Shaughnessy B. Friedman, B. O'Shaughnessy, Phys. Rev. A 40 (1989) 5950]. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Molecular dynamics simulations of electroporation in POPC and DPPC lipid bilayers have been carried out at different temperatures ranging from 230 K to 350 K for varying electric fields. The dynamics of pore formation, including threshold field, pore initiation time, pore growth rate, and pore closure rate after the field is switched off, was studied in both the gel and liquid crystalline (L-alpha) phases of the bilayers. Using an Arrhenius model of pore initiation kinetics, the activation energy for pore opening was estimated to be 25.6 kJ mol(-1) and 32.6 kJ mol(-1) in the L-alpha phase of POPC and DPPC lipids respectively at a field strength of 0.32 V nm(-1). The activation energy decreases to 24.2 kJ mol(-1) and 23.7 kJ mol(-1) respectively at a higher field strength of 1.1 V nm(-1). At temperatures below the melting point, the activation energy in the gel phase of POPC and DPPC increases to 28.8 kJ mol(-1) and 34.4 kJ mol(-1) respectively at the same field of 1.1 V nm(-1). The pore closing time was found to be higher in the gel than in the L-alpha phase. The pore growth rate increases linearly with temperature and quadratically with field, consistent with viscosity limited growth models.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An extended computational model of the circulatory system has been developed to predict blood flow in the presence of ventricular assist devices (VADs). A novel VAD, placed in the descending aorta, intended to offload the left ventricle (LV) and augment renal perfusion is being studied. For this application, a better understanding of the global hemodynamic response of the VAD, in essence an electrically driven pump, and the cardiovascular system is necessary. To meet this need, a model has been established as a nonlinear, lumped-parameter electrical analog, and simulated results under different states [healthy, congestive heart failure (CHF), and postinsertion of VAD] are presented. The systemic circulation is separated into five compartments and the descending aorta is composed of three components to accurately yield the system response of each section before and after the insertion of the VAD. Delays in valve closing time and blood inertia in the aorta were introduced to deliver a more realistic model. Pump governing equations and optimization are based on fundamental theories of turbomachines and can serve as a practical initial design point for rotary blood pumps. The model's results closely mimic established parameters for the circulatory system and confirm the feasibility of the intra-aortic VAD concept. This computational model can be linked with models of the pump motor to provide a valuable tool for innovative VAD design.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Understanding how the timing of motor output is coupled to sensory temporal information is largely based on synchronisation of movements through small motion gaps (finger taps) to mostly empty sensory intervals (discrete beats). This study investigated synchronisation of movements between target barriers over larger motion gaps when closing time gaps of intervals were presented as either continuous, dynamic sounds, or discrete beats. Results showed that although synchronisation errors were smaller for discrete sounds, the variability of errors was lower for continuous sounds. Furthermore, finger movement between targets was found to be more sinusoidal when continuous sensory information was presented during intervals compared to discrete. When movements were made over larger amplitudes, synchronisation errors tended to be more positive and movements between barriers more sinusoidal, than for movements over shorter amplitudes. These results show that the temporal control of movement is not independent from the form of the sensory information that specifies time gaps or the magnitude of the movement required for synchronisation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In Sweden the number of rural food shops has decreased for more than 50 years. Often the closing of a village shop is supposed to affect the migration patterns in the area it has been serving. However, according to this study, neither in- nor out-migration in the area affected by the closing is affected. The deficits of migration usual in those areas are established at least 10-12 years before the closing year. Thus, the typical closing takes place subsequent to a long term population decline. On the other hand, localities hosting a shop that survived during the study period 1990-2004 have a bigger total population and show tendencies towards decreasing deficit of migration at any potential closing year. These statistical results are supported by interviews carried out in three villages where the last shop has closed. They indicate that the shop has already lost its importance as supplier when it closes. By then the village shop is primarily used as complement to nearby towns or shopping centres. Each of the two studies accounted for here point at a relative un-importance of the village shop as a service point at the closing time. However, as it often offer the last public space in the village the village shop serves a key function as a meeting point for some households. When the shop has closed, the village holds private homes only. That is a situation increasing loneliness to some inhabitants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aims to analyze data from a Natural Electric Potential landfill type ditch located in Cordeirópolis (SP). The procedure measures initially involved the assembly and installation of an apparatus cables, sensors and drain geophysical measurements and flow rate of biogas in a ditch later filled by solid waste. Biogas is a product of degradation of organic matter in waste by the action of microorganisms in an anaerobic environment. Its features high methane content in the gas potentially usable as fuel in energy generation systems or steam. The study area is characterized by clayey soil composition change from the diabase sill correlated to the event Serra Geral Formation siltstones overlapping Tatuí with groundwater level site around 50m. The cables were installed vertically in parallel with drain gas manifold, which allowed the collection of data by the technique geophysical logging every 15 days over a period of eight months. For data analysis we used four parameters in the study, the closing time of the ditch, natural electric potential, the flow velocity of biogas and rain. With the tabulated data plots were constructed for each collection day showing values in the range of the cable is in contact with waste (200 cm - 400 cm) and range of the cable in contact with the soil (600 cm - 800 cm). Subsequently graphs were generated with the period of eight months to analyze the data tabulated. A statistical correlation data, which show the influence of rainfall on the production of biogas. The results were satisfactory and demonstrated the feasibility of the research method in studies for the feasibility analysis for the capture of biogas energy

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Gracias Laboratory at Johns Hopkins University has developed microgrippers which utilize chemically-actuated joints to be used in micro-surgery. These grippers, however, take up to thirty minutes to close fully when activated biochemicals in the human body. This is very problematic and could limit the use of the devices in surgery. It is the goal of this research to develop a gripper that uses theGracias Laboratory's existing joints in conjunction with mechanical components to decrease the closing time. The purpose of including the mechanical components is to induce a state of instability at which time a small perturbation would cause the joint to close fully.The main concept of the research was to use the lateral buckling of a triangular gripper geometry and use a toggle mechanism to decrease the closure time of the device. This would create a snap-action device mimicking the quick closure of a Venus flytrap. All developed geometries were tested using finite element analysis to determine ifloading conditions produced the desired buckled shape. This research examines lateral buckling on the micro-scale and the possibility ofusing this phenomenon in a micro-gripper. Although a final geometry with the required deformed shaped was not found, this document contains suggestions for future geometries that may produce the correct deformed shape. It was determined through this work that in order to obtain the desired deformed shape, polymeric sections need to be added to the geometry. This simplifies the analysis and allows the triangular structure to buckle in the appropriate way due to the added joints. Future work for this project will be completed by undergraduate students at Bucknell University. Fabrication and testing of devices will be done at Johns Hopkins University in the Gracias Laboratory.