157 resultados para eyelid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The cornea is known to be susceptible to forces exerted by eyelids. There have been previous attempts to quantify eyelid pressure but the reliability of the results is unclear. The purpose of this study was to develop a technique using piezoresistive pressure sensors to measure upper eyelid pressure on the cornea. Methods: The technique was based on the use of thin (0.18 mm) tactile piezoresistive pressure sensors, which generate a signal related to the applied pressure. A range of factors that influence the response of this pressure sensor were investigated along with the optimal method of placing the sensor in the eye. Results: Curvature of the pressure sensor was found to impart force, so the sensor needed to remain flat during measurements. A large rigid contact lens was designed to have a flat region to which the sensor was attached. To stabilise the contact lens during measurement, an apparatus was designed to hold and position the sensor and contact lens combination on the eye. A calibration system was designed to apply even pressure to the sensor when attached to the contact lens, so the raw digital output could be converted to actual pressure units. Conclusions: Several novel procedures were developed to use tactile sensors to measure eyelid pressure. The quantification of eyelid pressure has a number of applications including eyelid reconstructive surgery and the design of soft and rigid contact lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the effect of hyaluronidase on eye and eyelid movements when used as an adjunct in sub-Tenon's anaesthesia. Methods: A total of 60 patients who had sub-Tenon's anaesthesia prior to phacoemulsification surgery were divided into two equal groups in a double-masked randomised controlled fashion. Of these, Group A had 4 ml lignocaine 2%, while Group B had 4ml lignocaine 2% with the addition of sodium hyaluronidase 75 IU/ml. Ocular motility, levator, and orbicularis oculi function were measured in all patients at 5 and 8 min. Levator function was scored from 0 (no function) to 3 (complete function) while orbicularis function was scored from 0 to 2. The score for ocular motility was the sum in four positions of gaze, each position scoring from 0 to 2. Results were compared using a nonparametric test. Results Group B achieved significantly better ocular and lid akinesia than Group A both at 5 and 8 min with P < 0.01. The median scores for levator function at 5 and 8 min were 2 for Group A and 0 for Group B. For orbicularis function, the median scores at both time intervals were 2 for Group A and 1 for Group B. For ocular motility, the median score for Group A at 5 min was 3 and at 8 min was 2.5; for Group B at 5 min was 0.5 and at 8 min was 0. Conclusions: The addition of hyaluronidase in sub-Tenon's anaesthesia has a significant effect in improving ocular and lid (levator and orbicularis) akinesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calyptommatus and Nothobachia genera of gymnophthalmid lizards are restricted to sandy open habitats on Sao Francisco River margins, northeastern Brazil. Phylogenetic relationships and geographic distribution of the four recognized species of Calyptommatus were analyzed from partial mitochondrial cyt b, 12S, and 16S rRNA genes sequencing, taking allopatric populations of the monotypic Nothobachia ablephara as the outgroup. In Calyptommatus a basal split separated C. sinebrachiatus, a species restricted to the eastern bank of the river, from the three other species. In this clade, C. confusionibus, found on western margin, was recovered as the sister group of the two other species, C. leiolepis and C. nicterus, from opposite margins. According to approximate date estimations, C. sinebrachiatus would have separated from the other congeneric species by 4.4-6.5 my, and C. nicterus, also from eastern bank, would be diverging by 1.8-2.6 my from C. leiolepis, the sister species on the opposite margin. C. confusionibus and C. leiolepis, both from western sandy areas, would be differentiating by 2.8-5.0 my. Divergence times of about 3.0-4.0 my were estimated for allopatric populations of Nothobachia restricted to western margin. Significant differences in 16S rRNA secondary structure relatively to other vertebrates are reported. Distinct evolutionary patterns are proposed for different taxa in those sandy areas, probably related to historical changes in the course of Sao Francisco River. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a patient with a phenotype characterized by mandibulofacial dysostosis with severe lower eyelid coloboma, cleft palate, abnormal ears, alopecia, delayed eruption and crowded teeth, and sensorioneural hearing loss. The karyotype and the screening for mutations in the coding region of TCOF1 gene were normal. The clinical signs of our case overlap the new mandibulofacial dysostosis described by Stevenson et al. [2007] and the case with Johnson-McMillin syndrome described by Cushman et al. [2005]. The similar clinical signs, mainly, the severe facial involvement observed in these cases suggest that they can represent a new distinct form of mandibulofacial dysostosis or the end of the spectrum of Johnson McMillin syndrome. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe spontaneous blink kinematics in Graves' upper eyelid retraction (UER).Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves' UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software.Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves' patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls.Conclusions: Patients with Graves' UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analisaram-se, à microscopia óptica, 28 glândulas da terceira pálpebra de cães, que morreram com cinomose. O diagnóstico de ceratoconjuntivite seca baseou-se nas alterações da superfície ocular e no teste da lágrima de Schirmer. À histologia, visibilizaram-se atrofia tubuloacina, espessamento do tecido conjuntivo e exudação inflamatória de leve a intensa com presença de plasmócitos, de histiócitos e por hipertrofia compensatória de algumas glândulas. O lume das glândulas encontrava-se hipertrofiado contendo células epiteliais descamadas, polimorfonucleares e hemácias, além de muco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small lesions located in the skin might be treated using the laser system. The purpose of this is to report the therapy of benign eyelid tumors using argon laser. Forty-four benign eyelid tumors were treated using argon blue-green laser with spot size of 500 μm, power from 1000 to 1200 mW and 0.3 second exposure time. The eyelid tumors were located mainly in the upper eyelid (65.9%) and the skin tag was the most frequent treated lesion (43.2%). The average number of laser shots to treat the lesions was 165. There was not observed any complication and all patients were satisfied with the results. The authors are considering the argon laser a benefit therapeutic method to treat benign tumors located in the eyelids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To detect the occurrence and expression of the suppressor gene p53 and of the oncogene c-Myc in eyelid tumors of dogs using the PCR, RT-PCR, PCR-ELISA and RT-PCR-ELISA techniques. These genes have not been described in dog eyelid tumors before. Methods: Nine samples of eyelid or third eyelid epithelial tumors were obtained from the archives of the Department of Veterinary Pathology. Tumor diagnosis was confirmed by evaluation of hematoxylin-eosin stained sections, and immunohistochemistry for cytokeratin AE1/AE3 and vimentin V9. A canine mammary tumor was used for positive control. Agarose gel electrophoresis, PCR-ELISA and RT-PCR-ELISA were used to detect p53 and c-Myc genes. Results: The occurrence of p53 was detected in most of the eyelid tumors and third eyelid tumors studied (88.8%, n = 8) and was expressed in 75% of the positive samples, as indicated by ELISA. The c-Myc gene was found in 77.7% (n = 7) of the samples and was expressed in eight samples. Conclusions: Eyelid and third eyelid tumors of dogs express both the p53 and the c-Myc genes as shown by PCR and RT-PCR. However, PCR ELISA and RT-PCR ELISA were more efficient in assessing occurrence and expression of these genes because they identified amplified products that were not detected by agarose gel electrophoresis. © 2010 American College of Veterinary Ophthalmologists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Assess the occurrence of secondary brow ptosis after upper lid blepharoplasty. Methods: Forty-five individuals (n90 brows) submitted to upper lid blepharoplasty, were assessed by means of a comparative analysis using pre- and post-operatively digital photographs, in the primary position of the eye. The images were processed using ImageJ software, transferred to a computer, to an electronic Microsoft Excel 2002® worksheet. Angular measurements were used, taking the lateral canthal angle of the brow, the most medial point of the brow, the medial canthal angle and the lateral canthal angle of the lid as anatomical reference points. When the outer angles were reduced or the inner angles increased after surgery this was considered a brow ptosis. Individuals who had undergone lid surgery associated with the eyebrow, previous eyebrow surgery and those with eyelid ptosis were excluded. The difference between the pre-operative and post-operative measurements were analyzed statistically using the Student's t-test for paired samples and the angular variation was compared with their corresponding contralateral sample using Wilcoxon's non-parametric test. Results: The measurements obtained after the blepharoplasty show significant variations from those before the surgery, indicating that the correction of redundant tissues in the brow accentuates the tendency of the eyebrow to move down. The alterations are more important in the lateral portion of the eyebrow and they occur bilaterally. Conclusion: The assessment of angular measurements obtained pre- and post-operatively showed that there are secondary changes in the position of the eyebrow as a result of upper eyelid blepharoplasty. © 2012 Informa Healthcare USA, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We quantified the main sequence of spontaneous blinks in normal subjects and Graves' disease patients with upper eyelid retraction using a nonlinear and two linear models, and examined the variability of the main sequence estimated with standard linear regression for 10-minute periods of time. Methods. A total of 20 normal subjects and 12 patients had their spontaneous blinking measured with the magnetic search coil technique when watching a video during one hour. The main sequence was estimated with a power-law function, and with standard and trough the origin linear regressions. Repeated measurements ANOVA was used to test the mean sequence stability of 10-minute bins measured with standard linear regression. Results. In 95% of the sample the correlation coefficients of the main sequence ranged from 0.60 to 0.94. Homoscedasticity of the peak velocity was not verified in 20% of the subjects and 25% of the patients. The power-law function provided the best main sequence fitting for subjects and patients. The mean sequence of 10-minute bins measured with standard linear regression did not differ from the one-hour period value. For the entire period of observation and the slope obtained by standard linear regression, the main sequence of the patients was reduced significantly compared to the normal subjects. Conclusions. Standard linear regression is a valid and stable approximation for estimating the main sequence of spontaneous blinking. However, the basic assumptions of the linear regression model should be examined on an individual basis. The maximum velocity of large blinks is slower in Graves' disease patients than in normal subjects. © 2013 The Association for Research in Vision and Ophthalmology, Inc.