999 resultados para extraocular muscle


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To quantify the risk of new diplopia in inferomedial orbital decompression performed for cosmetic reasons. Methods: Retrospective analysis of 114 patients with Graves orbitopathy who underwent an inferomedial orbital decompression. No patient had diplopia in any of the gaze positions or optic neuropathy. A single coronal slice 9 mm posterior to the lateral orbital rim was employed to quantify the muscular index of the extraocular recti and of the superior complex. A control group of 56 patients imaged for other reasons were also measured. After surgery the oculomotor status of all patients who complained of diplopia and of 51 patients free of diplopia was measured with the prism and cover test in the primary and secondary gaze positions. Results: The rate of new-onset diplopia was 14.0% (16 patients). Eye deviations were confirmed in 14 patients. Of these, 10 had significant strabismus that warranted surgical or prism treatment. Most patients had esotropia associated with small vertical deviations. The size of the medial and inferior recti was significantly associated with the development of diplopia. The estimated odds for the appearance of diplopia in patients with muscle enlargement was 12.76 (medial rectus) and 5.21 (inferior rectus). Small-angle deviations were also detected in 27.4% of patients who did not experience diplopia. Conclusions: Medial and inferior recti enlargement is a strong predictor of new-onset diplopia. A large number of patients who do not report diplopia also present with small-angle deviations. (Ophthal Plast Reconstr Surg 2012;28:204-207)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The myoneural junctions present in the opossum (Didelphis albiventris) extraocular muscles were studied through histochemical and ultrastructural techniques. Three different types of junction were shown: two single types, 'en grappe' and 'en plaque', present in the middle third of the muscle fibers; and one multiple type, more rare and observed in the distal third of the muscle.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To present a technique for filling facial folds by using autologous orbicularis oculi muscle, based on an experimental model. Methods: two studies are presented: (1) an experimental study using 15 albino guinea-pigs from which a strip of the sural triceps muscle was removed and implanted in the subcutaneous tissue of the dorsal area. The animals were sacrificed 7, 30 and 60 days after the implantation, and the material was histologically evaluated. And (2%) an interventional prospective clinical trial carried out on 20 patients referred to blepharoplasty surgery. They received autologous preseptal orbicularis muscle for filling facial folds. The results where evaluated by patients satisfaction and clinical exam. Results: the sural tricep muscle, when implanted in the subcutaneous tissue, resulted in fibrosis. The patients whom received autologous orbicularis muscle implanted for filling facial folds showed that the procedure can be successfully carried out. Conclusions: autologous preseptal orbicularis muscle is a good material for filling facial folds. Cicatricial tissue will be formed on its implantation site, filling the tissue gap that forms the folds on the skin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Results of 3 tests, intravenous edrophonium chloride, EMG, and acetylcholine receptor antibody testing, were compared in patients with generalised and ocular myasthenia gravis. None of the 3 tests was positive in any patient with a diagnosis other than myasthenia. However, equivocal results were obtained with edrophonium and EMG testing in some patients with myasthenia gravis and in patients with other diseases. It is concluded from this survey that antibody and edrophonium testing were equally efficient in detecting generalised myasthenia gravis. Edrophonium testing was superior in ocular myasthenia gravis. Although the yields from each test varied, all 3 tests were needed for the evaluation of some myasthenia gravis patients as each test may provide additional information.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Near work may play an important role in the development of myopia in the younger population. The prevalence of myopia has also been found to be higher in occupations that involve substantial near work tasks, for example in microscopists and textile workers. When nearwork is performed, it typically involves accommodation, convergence and downward gaze. A number of previous studies have examined the effects of accommodation and convergence on changes in the optics and biometrics of the eye in primary gaze. However, little is known about the influence of accommodation on the eye in downward gaze. This thesis is primarily concerned with investigating the changes in the eye during near work in downward gaze under natural viewing conditions. To measure wavefront aberrations in downward gaze under natural viewing conditions, we modified a commercial Shack-Hartmann wavefront sensor by adding a relay lens system to allow on-axis ocular aberration measurements in primary gaze and downward gaze, with binocular fixation. Measurements with the modified wavefront sensor in primary and downward gaze were validated against a conventional aberrometer using both a model eye and in 9 human subjects. We then conducted an experiment to investigate changes in ocular aberrations associated with accommodation in downward gaze over 10 mins in groups of both myopes (n = 14) and emmetropes (n =12) using the modified Shack-Hartmann wavefront sensor. During the distance accommodation task, small but significant changes in refractive power (myopic shift) and higher order aberrations were observed in downward gaze compared to primary gaze. Accommodation caused greater changes in higher order aberrations (in particular coma and spherical aberration) in downward gaze than primary gaze, and there was evidence that the changes in certain aberrations with accommodation over time were different in downward gaze compared to primary gaze. There were no obvious systematic differences in higher order aberrations between refractive error groups during accommodation or downward gaze for fixed pupils. However, myopes exhibited a significantly greater change in higher order aberrations (in particular spherical aberration) than emmetropes for natural pupils after 10 mins of a near task (5 D accommodation) in downward gaze. These findings indicated that ocular aberrations change from primary to downward gaze, particularly with accommodation. To understand the mechanism underlying these changes in greater detail, we then extended this work to examine the characteristics of the corneal optics, internal optics, anterior biometrics and axial length of the eye during a near task, in downward gaze, over 10 mins. Twenty young adult subjects (10 emmetropes and 10 myopes) participated in this study. To measure corneal topography and ocular biometrics in downward gaze, a rotating Scheimpflug camera and an optical biometer were inclined on a custom built, height and tilt adjustable table. We found that both corneal optics and internal optics change with downward gaze, resulting in a myopic shift (~0.10 D) in the spherical power of the eye. The changes in corneal optics appear to be due to eyelid pressure on the anterior surface of the cornea, whereas the changes in the internal optics (an increase in axial length and a decrease in anterior chamber depth) may be associated with movement of the crystalline lens, under the action of gravity, and the influence of altered biomechanical forces from the extraocular muscles on the globe with downward gaze. Changes in axial length with accommodation were significantly greater in downward gaze than primary gaze (p < 0.05), indicating an increased effect of the mechanical forces from the ciliary muscle and extraocular muscles. A subsequent study was conducted to investigate the changes in anterior biometrics, axial length and choroidal thickness in nine cardinal gaze directions under the actions of the extraocular muscles. Ocular biometry measurements were obtained from 30 young adults (10 emmetropes, 10 low myopes and 10 moderate myopes) through a rotating prism with 15° deviation, along the foveal axis, using a non-contact optical biometer in each of nine different cardinal directions of gaze, over 5 mins. There was a significant influence of gaze angle and time on axial length (both p < 0.001), with the greatest axial elongation (+18 ± 8 μm) occurring with infero-nasal gaze (p < 0.001) and a slight decrease in axial length in superior gaze (−12 ± 17 μm) compared with primary gaze (p < 0.001). There was a significant correlation between refractive error (spherical equivalent refraction) and the mean change in axial length in the infero-nasal gaze direction (Pearson's R2 = 0.71, p < 0.001). To further investigate the relative effect of gravity and extraocular muscle force on the axial length, we measured axial length in 15° and 25° downward gaze with the biometer inclined on a tilting table that allowed gaze shifts to occur with either full head turn but no eye turn (reflects the effect of gravity), or full eye turn with no head turn (reflects the effect of extraocular muscle forces). We observed a significant axial elongation in 15° and 25° downward gaze in the full eye turn condition. However, axial length did not change significantly in downward gaze over 5 mins (p > 0.05) in the full head turn condition. The elongation of the axial length in downward gaze appears to be due to the influence of the extraocular muscles, since the effect was not present when head turn was used instead of eye turn. The findings of these experiments collectively show the dynamic characteristics of the optics and biometrics of the eye in downward gaze during a near task, over time. These were small but significant differences between myopic and emmetropic eyes in both the optical and biomechanical changes associated with shifts of gaze direction. These differences between myopes and emmetropes could arise as a consequence of excessive eye growth associated with myopia. However the potentially additive effects of repeated or long lasting near work activities employing infero-nasal gaze could also act to promote elongation of the eye due to optical and/or biomechanical stimuli.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the changes occurring in the axial length, choroidal thickness and anterior biometrics of the eye during a 10 minute near task performed in downward gaze. Methods: Twenty young adult subjects (10 emmetropes and 10 myopes) participated in this study. To measure ocular biometrics in downward gaze, an optical biometer was inclined on a custom built, height and tilt adjustable table. Baseline measures were collected after each subject performed a distance primary gaze control task for 10 mins, to provide wash-out period for prior visual tasks before each of three different accommodation/gaze conditions. These other three conditions included a near task (2.5 D) in primary gaze, and a near (2.5 D) and a far (0 D) accommodative task in downward gaze (25°), all for 10 mins duration. Immediately after, and then 5 and 10 mins from the commencement of each trial, measurements of ocular biometrics (e.g. anterior biometrics, axial length, choroidal thickness and retinal thickness) were obtained. Results: Axial length increased with accommodation and was significantly greater for downward gaze with accommodation (mean change ± SD 23 ± 13 µm at 10 mins) compared to primary gaze with accommodation (mean change 8 ± 15 µm at 10 mins) (p < 0.05). A small amount of choroidal thinning was also found during accommodation that was statistically significant in downward gaze (13 ± 14 µm at 10 mins, p < 0.05). Accommodation in downward gaze also caused greater changes in anterior chamber depth and lens thickness compared to accommodation in primary gaze. Conclusion: Axial length, choroidal thickness and anterior eye biometrics change significantly during accommodation in downward gaze as a function of time. These changes appear to be due to the combined influence of biomechanical factors (i.e. extraocular muscle forces, ciliary muscle contraction) associated with near tasks in downward gaze.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the changes in axial length with the combined effect of accommodation and angle of gaze (convergence and downward gaze) over 5 minutes in groups of myopes and emmetropes. Methods: A total of 31 subjects (nine emmetropes, 10 low myopes, and 12 moderate to high myopes) aged from 18 to 31 years were recruited. To measure ocular biometrics in inferonasal gaze with accommodation, an optical biometer (Lenstar LS900) was inclined on a tilt and height adjustable stage, with the subject’s chinrest mounted on a rotary stage to induce various levels of convergence by rotation of the subject’s head in primary or downward gaze. Initially, the subjects performed a distance viewing task in primary gaze for 10 minutes to provide a ‘wash-out’ period for prior visual tasks, and then the subject’s axial length and ocular biometrics were measured in nine different combinations of gaze/accommodation over 5 minutes. These nine sessions for all gaze measurements (i.e. three levels of accommodation 9 three levels of convergence) were completed across 3 days of testing (one accommodation condition on each day).The nine combinations of gaze/accommodation were based on those required to view the centre, right and left edges of a distant TV at 6 m in primary gaze, an intermediate task (i.e. computer at 50 cm in 10° downward gaze) and a near task (i.e. reading A4 page at 20 cm in 20° downward gaze). Subjects were wearing a custom built three-axes head tracker throughout the experiment that monitored subjects’ relative head movements (roll, pitch and yaw) during measurements. Results: A significant increase in axial length occurred with the combined effect of accommodation, convergence and downward gaze (repeated measures ANOVA, p < 0.001), with the greatest axial elongation during the near task in downward gaze with convergence (i.e. downward 20°/inward 33°, with 5 D accommodation) (mean change 33 ± 13 lm, after 5 minutes task) followed by the intermediate task (i.e. downward 10°/inward 25°, with 2 D accommodation) (mean change 14 ± 11 lm, after 5 minutes task).Changes in axial length for the distance task (i.e. primary gaze/9° convergence, with 0.16 D accommodation) were not statistically significant (mean change 4 ± 8 lm, after 5 minutes task, p > 0.05). Moderate to high myopes had a greater change in the axial length (mean change 40 ± 11 lm after 5 minutes of near task) than that of emmetropes (mean change 29 ± 15 lm after 5 minutes of near task) and low myopes (mean change 29 ± 16 lm after 5 minutes of near task) associated with time (p = 0.02) and accommodation by time (p = 0.03). Conclusions: The combination of accommodation, convergence and downward angle has a significant short term effect on axial length over time. The near task in downward gaze with convergence caused a greater change in axial length than the intermediate and distant visual tasks. The greater axial elongation measured in the infero-nasal direction with accommodation is most likely associated with a combination of biomechanical factors such as, extraocular muscle forces and ciliary muscle contraction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the first section of this thesis, two-dimensional properties of the human eye movement control system were studied. The vertical - horizontal interaction was investigated by using a two-dimensional target motion consisting of a sinusoid in one of the directions vertical or horizontal, and low-pass filtered Gaussian random motion of variable bandwidth (and hence information content) in the orthogonal direction. It was found that the random motion reduced the efficiency of the sinusoidal tracking. However, the sinusoidal tracking was only slightly dependent on the bandwidth of the random motion. Thus the system should be thought of as consisting of two independent channels with a small amount of mutual cross-talk.

These target motions were then rotated to discover whether or not the system is capable of recognizing the two-component nature of the target motion. That is, the sinusoid was presented along an oblique line (neither vertical nor horizontal) with the random motion orthogonal to it. The system did not simply track the vertical and horizontal components of motion, but rotated its frame of reference so that its two tracking channels coincided with the directions of the two target motion components. This recognition occurred even when the two orthogonal motions were both random, but with different bandwidths.

In the second section, time delays, prediction and power spectra were examined. Time delays were calculated in response to various periodic signals, various bandwidths of narrow-band Gaussian random motions and sinusoids. It was demonstrated that prediction occurred only when the target motion was periodic, and only if the harmonic content was such that the signal was sufficiently narrow-band. It appears as if general periodic motions are split into predictive and non-predictive components.

For unpredictable motions, the relationship between the time delay and the average speed of the retinal image was linear. Based on this I proposed a model explaining the time delays for both random and periodic motions. My experiments did not prove that the system is sampled data, or that it is continuous. However, the model can be interpreted as representative of a sample data system whose sample interval is a function of the target motion.

It was shown that increasing the bandwidth of the low-pass filtered Gaussian random motion resulted in an increase of the eye movement bandwidth. Some properties of the eyeball-muscle dynamics and the extraocular muscle "active state tension" were derived.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The investigation was centered on the morphological features of the conjunctiva-cornea transition (limbus) of the rabbit eye and the proliferative behavior of its epithelium. The eyes were processed for examination with light and electron microscopy, as well as for autoradiography after intravitreal injection of [H-3]thymidine ([H-3]TdR). At the sites of extraocular muscle insertion, the vascularization of the stroma extended to the peripheral cornea, and the limbal epithelium was thin with its basal stratum made up by clear cuboidal cells. In between the muscle insertions, the cuboidal clear cells, as well as the stroma blood vessels; were scarce. At the light microscope level, the basement membrane was distinct in the cornea but not in the limbus or the conjunctiva. Autoradiographs demonstrated that, at the limbus, the basal cells migrated very quickly to the suprabasal region and remained there up to the 28-day interval. Labeled cells were identified in all epithelial layers of the cornea, including the basal one, at 21 and 28 days but not in the limbal basal clear cells. The rate of renewal of conjunctival epithelium was similar to that observed for the transition with scarce clear cells. The high-resolution autoradiographs demonstrated that the basal cuboidal clear limbal cells exhibit a quick renewal and that they are not label-retaining cells. These latter ones were detected all over the corneal epithelium and in the suprabasal layers of the limbus up to 28 days, in physiological conditions, without the need of stimulation by damage to the corneal epithelium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Impacted knife injuries in the maxillofacial region are rare and infrequently reported. In cases of injury involving orbit or eye, these reports are even rarer. Discussion: Damage to the orbital contents may result in a rupture of the globe, extraocular muscle injury, lacrimal gland damage, and others. Orbital foreign bodies are not only difficult to detect, and clinical features vary according to its size, characteristics, shape, penetrating method, and site. In this report, a case of abducens nerve palsy after orbitoethmoidal knife injury is presented. © 2010 Springer-Verlag.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The extraocular muscle fibres of the South-American opossum were determined according to their metabolic profiles using NADH-diaforase, and myofibrilar ATPase after pre-incubation in both acid (pH 4.3) and alkaline (pH 10.4) media. Three muscles were selected to study the arrangement of the fibres (obliquous dorsalis, rectus dorsalis and rectus lateralis muscles). It was demonstrated that they are organized in two layers: the orbital layer composed by small diameter fibres and the global layer with three-times thicker fibres than the former. The global layer has three fibre types: white, red and intermediate; while the orbital layer presents two fibre types, which react differently to the ATPase.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ability of orbital apex crowding volume measurements calculated with multidetector-computed tomography to detect dysthyroid optic neuropathy. METHODS: Ninety-three patients with Graves' orbitopathy were studied prospectively. All of the patients underwent a complete neuro-ophthalmic examination and computed tomography scanning. Volumetric measurements were calculated from axial and coronal contiguous sections using a dedicated workstation. Orbital fat and muscle volume were estimated on the basis of their attenuation values (in Hounsfield units) using measurements from the anterior orbital rim to the optic foramen. Two indexes of orbital muscle crowding were calculated: i) the volumetric crowding index, which is the ratio between soft tissue (mainly extraocular muscles) and orbital fat volume and is based on axial scans of the entire orbit; and ii) the volumetric orbital apex crowding index, which is the ratio between the extraocular muscles and orbital fat volume and is based on coronal scans of the orbital apex. Two groups of orbits (with and without dysthyroid optic neuropathy) were compared. RESULTS: One hundred and two orbits of 61 patients with Graves' orbitopathy met the inclusion criteria and were analyzed. Forty-one orbits were diagnosed with Graves' orbitopathy, and 61 orbits did not have optic neuropathy. The two groups of orbits differed significantly with regard to both of the volumetric indexes (p<0.001). Although both indexes had good discrimination ability, the volumetric orbital apex crowding index yielded the best results with 92% sensitivity, 86% specificity, 81%/94% positive/negative predictive value and 88% accuracy at a cutoff of 4.14. CONCLUSION: This study found that the orbital volumetric crowding index was a more effective predictor of dysthyroid optic neuropathy than previously described computed tomography indexes were.