852 resultados para exercise, axial length, intraocular pressure, myopia, refractive error


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate choroidal thickness in young subjects using Enhanced Depth Imaging Spectral Domain Optical Coherence Tomography (EDI SD-OCT) describing volume differences between all the defined areas of the Early Treatment Diabetic Retinopathy Study (ETDRS). Design: Prospective, clinical study. Methods: Seventy-nine eyes of 95 healthy, young (23.8±3.2years), adult volunteers were prospectively enrolled. Manual choroidal segmentation on a 25-raster horizontal scan protocol was performed. The measurements of the nine subfields defined by the ETDRS were evaluated. Results: Mean subfoveal choroidal thickness was 345.67±81.80μm and mean total choroidal volume was 8.99±1.88mm3. Choroidal thickness and volume were higher at the superior and temporal areas compared to inferior and nasal sectors of the same diameter respectively. Strong correlations between subfoveal choroidal thickness and axial length (AL) and myopic refractive error were obtained, r = -0.649, p<0.001 and r = 0.473, p<0.001 respectively. Emmetropic eyes tended to have thicker subfoveal choroidal thickness (381.94±79.88μm versus 307.04±64.91μm) and higher total choroidal volume than myopic eyes (9.80± 1.87mm3 versus 8.14±1.48mm3). The estimation of the variation of the subfoveal choroidal thickness with the AL was-43.84μm/mm. In the myopic group, the variation of the subfoveal choroidal thickness with the myopic refractive error was -10.45μm/D. Conclusions: This study establishes for the first time a normal database for choroidal thickness and volume in young adults. Axial length, and myopic ammetropy are highly associated with choroidal parameters in healthy subjects. EDI SD-OCT exhibited a high degree of intraobserver and interobserver repeatability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To investigate the change that occurs in intraocular pressure (IOP) and ocular pulse amplitude (OPA) with accommodation in young adult myopes and emmetropes. Methods: Fifteen progressing myopic and 17 emmetropic young adult subjects had their IOP and OPA measured using the Pascal dynamic contour tonometer. Measurements were taken initially with accommodation relaxed, and then following 2 min of near fixation (accommodative demand 3 D). Baseline measurements of axial length and corneal thickness were also collected prior to the IOP measures. Results: IOP significantly decreased with accommodation in both the myopic and emmetropic subjects (mean change 1.861.1 mm Hg, p<0.0001). There was no significant difference (p>0.05) between myopes and emmetropes in terms of baseline IOP or the magnitude of change in IOP with accommodation. OPA also decreased significantly with accommodation (mean change for all subjects 0.560.5, p<0.0001). The myopic subjects (baseline OPA 2.060.7 mm Hg) exhibited a significantly lower baseline OPA (p¼0.004) than the emmetropes (baseline OPA 3.261.3 mm Hg),and a significantly lower magnitude of change in OPA with accommodation. Conclusion: IOP decreases significantly with accommodation, and changes similarly in progressing myopic and emmetropic subjects. However, differences found between progressing myopes and emmetropes in the mean OPA levels and the decrease in OPA associated with accommodation suggested some changes in IOP dynamics associated with myopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to investigate the influence of water loading upon intraocular pressure (IOP), ocular pulse amplitude (OPA) and axial length. Twenty one young adult subjects who were classified based on their spherical equivalent refraction as either myopes (n=11), or emmetropes (n=10) participated. Measures of IOP, OPA and ocular biometrics were collected before, and then 10, 15, 25 and 30 minutes following the ingestion of 1000 ml of water. Significant increases in both IOP and OPA were found to occur following water loading (p<0.0001), with peaks in both parameters occurring at 10 minutes after water loading (mean ± SEM increase of 2.24 ± 0.31 mmHg in IOP and 0.46 ± 0.06 mmHg in OPA). Axial length was found to reduce significantly following water loading (p=0.0005), with the largest reduction in axial length evident 10 minutes after water drinking (mean decrease 12 ± 3 µm). A significant time by refractive error group interaction (p=0.048) was found in axial length, indicative of a different pattern of change in eye length following water loading between the myopic and emmetropic populations. The largest difference in axial length change was evident at 10 minutes after water loading with a 17 ± 5 µm reduction in axial length evident in the myopes and only a 6 ± 2 µm reduction in the emmetropes. These findings illustrate significant changes in ocular parameters in young adult subjects following water loading.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To describe the time-course and amplitude of changes to sub-foveal choroidal thickness (SFCT) induced by imposed hyperopic and myopic retinal defocus and to compare the responses in emmetropic and myopic subjects. METHODS: Twelve East Asian subjects (age: 18-34 years; six were emmetropic and six had myopia between -2.00 and -5.00 dioptres (D)) viewed a distant target (video movie at 6 m) for 60 min on two separate occasions while optical coherence tomography (OCT) images of the choroid were taken in both eyes every 5 min to monitor SFCT. On each occasion, one eye was optimally corrected for distance with a contact lens while the other eye wore a contact lens imposing either 2.00 D hyperopic or 2.00 D myopic retinal defocus. RESULTS: Baseline SFCT in myopic eyes (mean ± S.D.): 256 ± 42 μm was significantly less than in emmetropic eyes (423 ± 62 μm; p < 0.01) and was correlated with magnitude of myopia (-39 μm per dioptre of myopia, R(2) = 0.67: p < 0.01). Repeated measures anova (General Linear Model) analysis revealed that in both subject groups, 2.00 D of myopic defocus caused a rapid increase in SFCT in the defocussed eye (significant by 10 min, increasing to approximately 20 μm within 60 min: p < 0.01), with little change in the control eye. In contrast, 2.00 D of hyperopic defocus caused a decrease in SFCT in the experimental eye (significant by 20-35 min. SFCT decreased by approximately 20 μm within 60 min: p < 0.01) with little change in the control eye. CONCLUSIONS: Small but significant changes in SFCT (5-8%) were caused by retinal defocus. SFCT increased within 10 min of exposure to 2.00 D of monocular myopic defocus, but decreased more slowly in response to 2.00 D of monocular hyperopic defocus. In our relatively small sample we could detect no difference in the magnitude of changes to SFCT caused by defocus in myopic eyes compared to emmetropic eyes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. The purpose of the study was to investigate the changes in axial length occurring with shifts in gaze direction. Methods. Axial length measurements were obtained from the left eye of 30 young adults (10 emmetropes, 10 low myopes, and 10 moderate myopes) through a rotating prism with 15° deviation, along the foveal axis, using a noncontact optical biometer in each of the nine different cardinal directions of gaze over 5 minutes. The subject's fellow eye fixated on an external distance (6 m) target to control accommodation, also with 15° deviation. Axial length measurements were also performed in 15° and 25° downward gaze with the biometer inclined on a tilting table, allowing gaze shifts to be achieved with either full head turn but no eye turn, or full eye turn with no head turn. Results. There was a significant influence of gaze angle and time on axial length (both P < 0.001), with the greatest axial elongation (+18 ± 8 μm) occurring with inferonasal gaze (P < 0.001) and a slight decrease in axial length in superior gaze (−12 ± 17 μm) compared with primary gaze (P < 0.001). In downward gaze, a significant axial elongation occurred when eye turn was used (P < 0.001), but not when head turn was used to shift gaze (P > 0.05). Conclusions. The angle of gaze has a small but significant short-term effect on axial length, with greatest elongation occurring in inferonasal gaze. The elongation of the eye appears to be due to the influence of the extraocular muscles, in particular the oblique muscles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the association between corneal hysteresis and axial length/refractive error among rural Chinese secondary school children. DESIGN: Cross-sectional cohort study. METHODS: Refractive error (cycloplegic auto-refraction with subjective refinement), central corneal thickness (CCT) and axial length (ultrasonic measurement), intraocular pressure (IOP), and corneal hysteresis (Reichert Ocular Response Analyzer) were measured on a rural school-based cohort of children. RESULTS: Among 1,233 examined children, the mean age was 14.7 +/- 0.8 years and 699 (56.7%) were girls. The mean spherical equivalent (n = 1,232) was -2.2 +/- 1.6 diopters (D), axial length (n = 643) was 23.7 +/- 1.1 mm, corneal hysteresis (n = 1,153) was 10.7 +/- 1.6 mm Hg, IOP (n = 1,153) was 17.0 +/- 3.4 mm Hg, and CCT (n = 1,226) was 553 +/- 33 microns. In linear regression models, longer axial length was significantly (P < .001 for both) associated with lower corneal hysteresis and higher IOP. Hysteresis in this population was significantly (P < .001) lower than has previously been reported for normal White children (n = 42, 12.3 +/- 1.3 mm Hg), when adjusting for age and gender. This difference did not appear to depend on differences in axial length between the populations, as it persists when only Chinese children with normal uncorrected vision are included. CONCLUSIONS: Prospective studies will be needed to determine if low hysteresis places eyes at risk for axial elongation secondary or if primary elongation results in lower hysteresis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods: This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results: Mean (±SD) CH and CRF were 12.12 (±1.71) and 12.30 (±1.89) mm Hg, respectively. Mean (±SD) CCT was 542.68 (±37.20) μm and mean (±SD) spherical equivalent was +0.14 (±3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions: The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To describe the distribution of central corneal thickness (CCT), intraocular pressure (IOP), and their determinants and association with glaucoma in Chinese adults.DESIGN: Population-based cross-sectional study.METHODS: Chinese adults aged 50 years and older were identified using cluster random sampling in Liwan District, Guangzhou. CCT (both optical [OCCT] and ultrasound [UCCT]), intraocular pressure (by Tonopen, IOP), refractive error (by autorefractor, RE), radius of corneal curvature (RCC), axial length (AL), and body mass index (BMI) were measured, and history of hypertension and diabetes (DM) was collected by questionnaire. Right eye data were analyzed.RESULTS: The mean values of OCCT, UCCT, and IOP were 512 ± 29.0 μm, 542 ± 31.4 μm, and 15.2 ± 3.1 mm Hg, respectively. In multiple regression models, CCT declined with age (P < .001) and increased with greater RCC (P < .001) and DM (P = .037). IOP was positively associated with greater CCT (P < .001), BMI (P < .001), and hypertension (P < .001). All 25 persons with open-angle glaucoma had IOP <21 mm Hg. CCT did not differ significantly between persons with and without open- or closed-angle glaucoma. Among 65 persons with ocular hypertension (IOP >97.5th percentile), CCT (555 ± 29 μm) was significantly (P = .01) higher than for normal persons.CONCLUSIONS: The distributions of CCT and IOP in this study are similar to that for other Chinese populations, though IOP was lower than for European populations, possibly due to lower BMI and blood pressure. Glaucoma with IOP <21 mm Hg is common in this population. We found no association between glaucoma and CCT, though power (0.3) for this analysis was low.