869 resultados para epoc® blood analysis system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microvessel density (MVD) is a widely used surrogate measure of angiogenesis in pathological specimens and tumour models. Measurement of MVD can be achieved by several methods. Automation of counting methods aims to increase the speed, reliability and reproducibility of these techniques. The image analysis system described here enables MVD measurement to be carried out with minimal expense in any reasonably equipped pathology department or laboratory. It is demonstrated that the system translates easily between tumour types which are suitably stained with minimal calibration. The aim of this paper is to offer this technique to a wider field of researchers in angiogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ubiquitous Computing is an emerging paradigm which facilitates user to access preferred services, wherever they are, whenever they want, and the way they need, with zero administration. While moving from one place to another the user does not need to specify and configure their surrounding environment, the system initiates necessary adaptation by itself to cope up with the changing environment. In this paper we propose a system to provide context-aware ubiquitous multimedia services, without user’s intervention. We analyze the context of the user based on weights, identify the UMMS (Ubiquitous Multimedia Service) based on the collected context information and user profile, search for the optimal server to provide the required service, then adapts the service according to user’s local environment and preferences, etc. The experiment conducted several times with different context parameters, their weights and various preferences for a user. The results are quite encouraging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrooxidation polymerization of phenothiazine derivatives, including azure A and toluidine blue 0, has been studied at screen-printed carbon electrodes in neutral phosphate buffer. Both compounds yield strongly adsorbed electroactive polymer with reversible behavior and formal potentials closed to 0.04 V at pH 6.9. The modified electrodes exhibited good stability and electrocatalysis for NADH oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 500 mV lower than that of the bare electrodes. Further, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5-100 muM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrooxidation polymerization of azure B on screen-printed carbon electrodes in neutral phosphate buffer was studied. The poly(azure B) modified electrodes exhibited excellent electrocatalysis and stability for dihydronicotinamide adenine dinucleotide (NADH) oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 400 mV lower than that at the bare electrodes. Different techniques, including cyclic voltammetry, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy have been employed to characterize the poly (azure B) film. Furthermore, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5 muM to 100 muM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A poly(thionine) modified screen-printed carbon electrode has been prepared by an electrooxidative polymerization of thionine in neutral phosphate buffer. The modified electrodes are found to give stable and reproducible electrocatlytic responses to NADH and exhibit good stability. Several techniques, including cyclic voltammetry, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM), have been employed to characterize the poly(thionine) film. Further, the modified screen-printed carbon electrode was found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 5-100 muM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection electrochemiluminescent method for L-cysteine determination has been developed based on its enhancement of the electrochemiluminecence of luminol at a glassy carbon electrode. This method is simple and sensitive for cysteine determination. Under the selected experimental parameters, the linear range for cysteine concentration was 1.0 x 10(-6) - 5.0 x 10(-5) mol/l, and the detection limit was 0.67 mumol/l (SIN = 3). The relative standard deviation for 11 measurements of 1.0 x 10(-5) mol/l cysteine was 4.5%. The proposed method has been applied to. the detection of cysteine in pharmaceutical injections with satisfactory results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We introduce "BU-MIA," a Medical Image Analysis system that integrates various advanced chest image analysis methods for detection, estimation, segmentation, and registration. BU-MIA evaluates repeated computed tomography (CT) scans of the same patient to facilitate identification and evaluation of pulmonary nodules for interval growth. It provides a user-friendly graphical user interface with a number of interaction tools for development, evaluation, and validation of chest image analysis methods. The structures that BU-MIA processes include the thorax, lungs, and trachea, pulmonary structures, such as lobes, fissures, nodules, and vessels, and bones, such as sternum, vertebrae, and ribs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increasingly, distributed systems are being used to host all manner of applications. While these platforms provide a relatively cheap and effective means of executing applications, so far there has been little work in developing tools and utilities that can help application developers understand problems with the supporting software, or the executing applications. To fully understand why an application executing on a distributed system is not behaving as would be expected it is important that not only the application, but also the underlying middleware, and the operating system are analysed too, otherwise issues could be missed and certainly overall performance profiling and fault diagnoses would be harder to understand. We believe that one approach to profiling and the analysis of distributed systems and the associated applications is via the plethora of log files generated at runtime. In this paper we report on a system (Slogger), that utilises various emerging Semantic Web technologies to gather the heterogeneous log files generated by the various layers in a distributed system and unify them in common data store. Once unified, the log data can be queried and visualised in order to highlight potential problems or issues that may be occurring in the supporting software or the application itself.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os cães possuem cinco grupos sangüíneos bem estabelecidos, compostos por sete determinantes antigênicos eritrocitários, os quais são denominados de dog erythrocyte antigen (DEA). O grupo DEA 1 (subgrupos 1.1, 1.2 e 1.3) tem sido considerado o mais importante no que se refere às transfusões de sangue. Isto ocorre porque esse grupo possui um alto potencial para estimulação antigênica e, dessa forma, pode estimular a produção de anticorpos se um receptor DEA 1 negativo receber uma transfusão de sangue DEA 1 positivo, levando a uma reação transfusional hemolítica em uma segunda transfusão com hemácias do tipo DEA 1. A freqüência de aparecimento do grupo DEA 1 é bem conhecida em outros países, porém, até então, não havia informações disponíveis sobre o referido grupo no Brasil. No presente estudo, objetivou-se avaliar a prevalência do grupo sangüíneo DEA 1 (subgrupos 1.1 e 1.2) em cães criados no Brasil. Para tanto, 150 cães de raças, sexos e idades diferentes, triados junto ao Hospital Veterinário da FCAV/UNESP, Campus de Jaboticabal, foram submetidos a tipagem sangüínea para o grupo DEA 1 (subgrupos 1.1 e 1.2) canino, utilizando-se reagentes adquiridos comercialmente junto ao Laboratório de Imunoematologia e Sorologia da Universidade de Michigan (EUA). Os resultados obtidos neste ensaio revelaram que a prevalência geral para o grupo DEA 1 é de 91,3%, consideradas as condições e características da população estudada, compreendendo 51,3% de cães do tipo DEA 1.1, 40% de cães do tipo DEA 1.2, e os 8,7% restantes sendo negativos para o referido grupo. A partir das prevalências encontradas, calculou-se que a probabilidade de um cão DEA 1 negativo receber sangue DEA 1.1, em uma primeira transfusão feita ao acaso, é de aproximadamente 4,5%. Sendo assim, este índice reflete um risco potencial para a sensibilização de um receptor DEA 1 negativo, o que deflagraria a produção de anticorpos. Posteriormente, se este mesmo paciente recebesse uma segunda transfusão de sangue, feita ao acaso, a probabilidade de receber hemácias do tipo DEA 1.1 seria de aproximadamente 2,3%, o que representaria o risco potencial de ocorrência de uma reação transfusional hemolítica aguda. Por outro lado, a probabilidade de este cão receber sangue do tipo DEA 1.2 seria cerca de 1,8%, o que levaria a uma reação transfusional menos grave, porém potencialmente prejudicial. No presente estudo, observou-se que o risco potencial para uma reação transfusional é mínimo, quando se trata de um cão mestiço.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)