304 resultados para eletroquímica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a study of electrochemical degradation of the chloramphenicol antibiotic in aqueous medium using a flow-by reactor with DSA® anode. The process efficiency was monitored by chloramphenicol concentration analysis with liquid chromatography (HPLC) during the experiments. Analysis of Total Organic Carbon (TOC) was performed to estimate the degradation degree and Ion Chromatography (IC) was performed to determinate inorganic ions formed during the eletrochemical degradation process. In electrochemical flow-by reactor, 52% of chloramphenicol was degraded, with 12% TOC reduction. IC analysis showed the production of chloride ions (25 mg L-1), nitrate ions (6 mg L-1) and nitrite ions (4.5 mg L-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fruits juices are natural sources of several compounds that present antioxidant action. Together with the fruits, they contribute with almost 40% of the antioxidant capacity in a healthy diet avoiding and preventing diseases deriving from oxidative stress. The present study determined the antioxidant capacity of seven samples of industrialized fruits juices applying CRAC (Ceric Reducing/Antioxidant Capacity) assay, a new electrochemistry assay that evaluates, by means of chronoamperometric measurements, the ability of a sample in reducing species Ce4+ in acid media. At the end of the assay was obtained the following classification: cashew > guava > grape > mango > apple > orange > passion fruit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A química do solo vem estudando o comportamento da fração mineral dos solos tropicais intemperizados, incluindo a eletroquímica, o desenvolvimento de cargas e o fenômeno de adsorção. Por causa do amplo espectro a ser coberto no entendimento do comportamento da fração mineral, somado às dificuldades metodológicas, o estudo da complexa fração orgânica dos solos foi relativamente menos desenvolvido. A atual proposta revisita os primeiros trabalhos referentes à química de solos tropicais, buscando relacioná-los com dados de eletroquímica dos estoques de carbono do solo. O objetivo deste trabalho foi revisar aspectos de eletroquímica de solos, determinar e relacionar os pontos de carga zero, por diferentes métodos, os potenciais da dupla camada elétricae a eletroquímica do húmus de solos modais brasileiros, em uma sequência típica de intemperismo, visando a gerar informações para o seu manejo e conservação. Os métodos de estimativa dos ponto de carga zero dos solos apresentam resultados variados, mas com a mesma tendência entre os solos. Há predomínio de cargas negativas em ambas as camadas dos solos estudados. As cargas negativas dos coloides estão diretamente associadas à disponibilidade de elétrons do húmus e ambas diminuem com o estádio de intemperismo do solo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A eletroquímica e a concentração de matéria orgânica nos horizontes superficiais de Latossolos correlacionam-se estreitamente. No presente trabalho, avaliaram-se as propriedades eletroquímicas do horizonte superficial de sete Latossolos brasileiros após a remoção das substâncias húmicas em meio alcalino. Os solos foram separados em dois grupos, segundo sua mineralogia, caulinítica e oxídica. O extrator NaOH 0,1 mol L-1 solubilizou substâncias húmicas correspondentes a menos de 3 % da MO total, indicando forte adsorção específica do material orgânico à fração mineral. A extração de ácidos húmicos e fúlvicos foi capaz de inverter o sinal de carga da superfície; no entanto, o efeito mais acentuado da retirada das substâncias húmicas solúveis foi a perda da capacidade-tampão das cargas do solo. A capacidade da dupla camada elétrica, uma medida indireta desse poder-tampão, aumentou de 3 a 15 vezes depois da extração das substâncias húmicas alcalino-solúveis. Solos com mineralogia predominantemente oxídica apresentaram maiores valores do ponto de efeito salino nulo, da capacidade da dupla camada elétrica, além da diminuição na capacidade de troca de cátions do que aqueles de natureza caulinítica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical synthesis of a ternary compound obtained by the intercalation of hydrated hexilaminium cations into the layered compound 1T-TiS2 is reported. Two different compounds were detected by cyclovoltammetry and studied by X-ray diffractometry. Models showing the steric arrangement of the hydrated hexilaminium cations into the Van der Waals gaps were proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper some studies concerning the electroreduction of Mo(VI) in sulphuric acid solutions are described. We have shown that at suitable experimental conditions very stable molybdenum oxide films can be electrochemically deposited at glassy carbon electrodes, the reduction of bromate occurring at less negative potentials on the modified surface. Coulometric experiments have shown that bromide is not the only product of the catalytic bromate reduction by the molybdenum film and species like BrO2 may have part in this process. Based on chronoamperometric curves recorded at -0.60 V, analytical curves have been obtained for the reduction of bromate in the 0.1 - 0.8 mM range, a limit of detection of 20 µM for bromate being determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a system for electrochemical hydride generation using flow-injection and atomic absorption spectrometry to determine selenium in biological materials. The electrolytic cell was constructed by assembling two reservoirs, one for the sample and the other for the electrolytic solution separated by a Nafion membrane. Each compartment had a Pt electrode. The sample and electrolyte flow-rates, acidic media, and applied current were adjusted to attain the best analytical performance and ensure the membrane lifetime. The atomisation system used a T quartz tube in an air-LPG flame. The composition of the flame, the observation height, and the argon flow rate used to carry the hydrides were critically investigated. The system allowed to perform thirty determinations per hour with a detection limit of 10 mug L-1 of Se. Relative standard deviations were in general lower than 1.5% for a solution containing 20.0 and 34.0 mug L-1 of Se in a typical sample digest. Accuracy was assessed analysing the certified materials: rice flour (NIST-1568) from National Institute of Standard and Technology and dried fish (MA-A-2), whole animal blood (A-2/1974) from the International Atomic Energy Agency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among in situ techniques, the electrochemical quartz crystal microbalance (EQCM) is a powerful tool for the study of electrochemical reactions that produce mass changes in the electrode/solution interface. This review present some systems in which the EQCM combined with classical electrochemical techniques, gives relevant information for understanding the charge transport process at a molecular level. The aim of this review is to do a brief description of experimental arrangements, with emphasis on some special cares that must be considered by the users. Secondly, some chosen electrochemical systems where the technique was successfully applied are discussed. Finally, a brief analysis of electroacoustic impedance experiments was done in order to show when the Sauerbrey equation can be used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow cell assembled on the original geometry of a graphite tube to achieve permanent chemical modifier is proposed. The graphite tube operates as the working electrode. A stainless steel tube, positioned downstream from the working electrode, was used as the auxiliary electrode. The potential value applied on the graphite electrode was measured against a micro reference electrode (Ag/AgCl) inserted into the auxiliary electrode. Palladium solutions in acetate buffer (100 mmol L-1, pH = 4.8), flowing at 0.5 mL min-1 for 60 min was used to perform the electrochemical modification. A mercury solution (1 ng) was used to evaluate the performance of the permanent palladium modifier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption of H and S2- species on Pd (100) has been studied with ab initio, density-functional calculations and electrochemical methods. A cluster of five Pd atoms with a frozen geometry described the surface. The computational calculations were performed through the GAUSSIAN94 program, and the basis functions adapted to a pseudo-potential obtained by using the Generator Coordinate Method adapted to the this program. Using the cyclic voltammetry technique through a Model 283 Potentiostat/Galvanostat E.G.&G-PAR obtained the electrochemical results. The calculated chemisorption geometry has a Pd-H distance of 1.55Å, and the potential energy surface was calculated using the Becke3P86//(GCM/DFT/SBK) methodology. The adsorption of S2- ions on Pd surface obtained both through comparison between the experimental and theoretical results, at MP2 level, suggest a S2- absorption into the metallic cluster. The produced Pd-(S2-) system was show to be very stable under the employed experimental conditions. The paper has shows the powerful aid of computational methods to interpret adsorption experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This text describes the development of Electrochemistry and Electroanalytical Chemistry in Brazil from the pioneers at the IQ/USP in the 70's to the present day status. It explains how the members of the scientific community organized themselves before the establishment in 1993 of a specific division within the Brazilian Chemical Society (SBQ) through bi-ennial meetings (Brazilian Symposium of Electrochemistry and Electroanalytical Chemistry - SIBEE). Those SIBEE meetings, in a present number of 12, are described individually giving some emphasis on their organizers, the invited speakers and the statistics and overall structure of the event. The activities of the Electrochemistry and Electroanalytical Chemistry Division of the SBQ from 1993 are also briefly discussed as well as some considerations are made on the present and future of these fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review focuses the development of electrochemical detection systems coupled to capillary electrophoresis. Conductometric, amperometric, voltametric, and potentiometric modes of detection are reviewed. The positioning of the electrodes, interferences of high electric field, and the materials employed in the fabrication and modification of the electrodes are discussed. The advantages of the use of electrochemical detection with capillary electrophoresis, regarding to the sensitivity and selectivity, is exemplified with a large number of applications. Also, the use of electrochemical detection systems in microchip technology is addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimization of ferrate(VI) ion generation has been studied due to its favorable characteristics for application in several fields, including environmental quality control. The paper presents the best conditions for electrolytic generation of ferrate(VI) in alkaline media. An appropriate electrolyte was NaOH, 10 mol/L. Circulation of the electrolyte solution was important to avoid acidification close to the anode surface. An anode pre-cleaning with 10% HCl was more efficient than a cathodic pre-polarization. Among the distinct anode materials tested, pig iron showed the best performance, allowing up to 20 g/L of Na2FeO4, in 10 mol/L NaOH solution to be obtained, after 7 h of reactor operation, which is a concentration higher than those found in literature for alternative processes.